Tensile Test report

Customer : Komar Pre-load : 0,3 MPa


Test standard : DIN EN ISO 527-1 Speed, tensile modulus : 1 mm/min
Material : HDPE + Bonggol Jagung 15% Test speed : 200 mm/min
Machine data : Zwick Z020 Grip to grip separation at the start position : 115,00 mm
Gage length, standard travel : 50 mm

Test results:
Force Et m m b b b h Travel Gage length, standard travel
Legend No. N MPa MPa % MPa % mm mm mm mm
1 479,83 242 12,4 27 12,4 27 9,98 3,89 36,13 50
2 512,28 268 13,3 28 13,3 28 9,94 3,87 39,55
3 499,02 275 13,2 27 13,2 27 9,92 3,8 36,99

Series graph:
20

15
Stress in MPa

10

0
0 50 100 150 200
Strain in %

Statistics:
Series Travel µ Force Et m m b b b h
n=3 mm N MPa MPa % MPa % mm mm
x 37,56 - 497,04 261 13,0 27 13,0 27 9,947 3,853
s 1,78 - 16,31 17,4 0,531 0,95 0,531 0,95 0,03055 0,04726
 [%] 4,74 - 3,28 6,66 4,10 3,48 4,10 3,48 0,31 1,23

3 Tensile HDPE + Bonggol Jagung 15%.zs2 Page 1/1