(NPSHA )Available net suction head = Static suction head + Surface pressure - Friction - Vapor pressure
From Charts friction head for 36'' & 20'' suction pipes = 0.105 ft
From Tables Vapor pressure (assume water with s.g = 1) @ 225 F = 18.85 PSI
(NPSHA )= (15+14.7)*2.31-0.105-(18.85*2.31) = 24.9 ft
Vapor pressure
From data sheet
(NPSHA )= (15+14.7)*2.31-0.105-(15.3*2.31)
(NPSHA )= 33.159 FT
At 12 Dec. 2008 suction sump temperature was 230 F Vapor pressure = 20.74PSI
(NPSHA )= 20.59 FT
FROM AQUATEC DATA SHEET (NPSHA )= 34 FT (INCLUDES 3 FT MARGIN)
(NPSHR)= 34.5 FT
The Unit is
Cavitated
Recommendations:
1- Increse evaporator liquid level 13 ft above recent evaporator level (60%)
with the same sump temperature 230 F
2- Increse evaporator liquid level 8 ft above recent evaporator level (60%)
At the fluid temperature = 225 F
3- Change pump design , for example install impeller inducer to increse (NPSHA)