You are on page 1of 6
FENWAL CONTROLS 400 Main St Ashland, MA 01721 Phone: 608-881-2000 Customer Customer, Order POF Sales Ordert Date y2asBEC 705279 FO 02/25/22 Ship To: 79005134 ASIA TECHNOLOGY, ONIT 5 dif FREE TRADE CENTER 49 TSUN YIP ST KWUN TONG KWUN TONG HONG KONG Shipping Instructions: PACKING SLIP Payment Shipment Rime "Bate Net60 Days 05108722 Freight Forwarder: Promise Request Date. Date 05708122 03125722 Lines fem, Item Description 3.900 17343-124.325 DETECTOR-OVERHEAT [ASIA TECH IND PACK. RoHS Compliant ‘These tems are controled by the U.S. government and ou K01.1.17949-124-825 Shipment thorized for export only to the country of Method 70003514 FED EX Page: 1 of 1 Seipment Freight Terms, OLY 013 - Inst Bill To: 770005134 ASIA TECHNOLOGY UNITS SIF FREE TRADE CENTER AS TSUN YIP ST KINUN TONG. KWUN TONG HONG KONG. Customer Service Representative: Esther Travers-Controls Esther Travers-Controls ty Shipped iy on Back Order 2 Llimate destination for use by the ultmats consignee ot Thgse ems are contol ve US et esd ranaere, or erie posed of (0 any aher COUNTY 1 3 eo eS timate conaignes o° end-user(s). ether i Sovemment oF as olneruise authorized bv i thelr oi ina form or afer belng Incorparat U'S law and reauiations. ae ol otner Reme, without frst odtaring approval from the US, NWAL F CONTROLS Page: tof t CERTIFICATE OF COMPLIANCE Purchase Order No. 12438/EC, Consignee 70005134 ASIA TECHNOLOGY UNIT 5 9/F FREE TRADE CENTER 49 TSUN YIP ST KWUN TONG KWUN TONG HONG KONG tom # Number Lit tem Description DETECTOR-OVERHEAT RoHS Compliant Reach Compliant 1000 17343-12425 Certificate No. 1059298, Date Issued Sales Order No. 05105122 705279 FO Shipper 400 Main St Ashland, MA 01721 Web Address: Kidde-Fenwal.com CSR Email. Esther, Travers@carrier.com vom ty Shipped EA 2 K01.1.17349-124.325 o2.17343-124-825,0174 4: itis hereby certified thatthe articles supplied in the above shipment onthe above order number, to the indicated contract, purchase order, drain conformance with the applicable requirements, specifications and drawings are in conformance wit ar ine materiale, assembles, fries, and processes used inthe arcs above est all specifications indicated per data sheets, inspections. co na lo and qualiy standards. The product has been inspected, functionally tested ang has passed all final inspection alis an ISO 9001:2015 registered company as coriied by BSI Registration no, FS Tease 3 Kidde Fo ied tha he artes named above with description “RoHS Compliant (or compan ‘with named annex exceptions) and cid on he above Kidde-Fenwal order number, to the indicated contact and purcnate oreor e ‘Conforming to the applicable requirements So oe er VGSIEU OF THe EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 8 JUNE 2011 on the restriction of the use of coe cus substances in electrical ad electric equipment onthe date this form is completes CERTIFIED BY soa) poof ee f CERTIFIED BY: Print Name: Seun Oluwole Quality rep _ CColC Form Revision: June 7, 2021 by Quality Department G Kidde Fenwal D-185 In Process and Final Inspection Record Reference Procedures: 58-12, Fist Piece, In Process, Last Pi Inspection, and “30-71, n Process and Final Inspecton and GCA Auci ‘ome Dest: E14 Craving Rev: 7348-124 AP WOR: 946513 __ Total WO Qty #: 2 Page « Pata: 17349-12692 Destin: DETECTOROVERHEAT Wo Print Date: 42772022 Attention: Confirm that materials match 8.0.M., latest revision of instructions are in use and all gages are calibrated. aay eat ae ontaet your load and supervisor. eee eee Test Spec 0! Descition ‘Aicwes T Awes | Sanpe | Pass’ [Qpeaior | cate | -vorr | Eaurmentwmame | aca | Date ene aoe ae d dq 9015/3 |= O 22. mikey Col Ta IPA od Wgse tga ett TOM B77 Wako a) Final Temp ehedk TPA 704 Liege 2 a Hapot T [Pe (69 |asor y % Ray Vee 1730 agKe i to etel iv, is fo |5/4/a2, ink samp 2 A yp GE 7 | es PQint ~ A [ox le v Trsus& L25- “Fa Val aco aac | nace | ae v F=ViSUAL INSPECTION hades: COMPONENTS” algned&seainepropary tighion FINISH dean, uniform, MATERIAL -no Burs, nosh e2ges, ABELS clear eabie All products require 100% final test & inspection, unless otherwise specified Build aty acceptance summary Total Pass pa ‘nen required use the sampling plan Below fori roca inspscten Comments: Total Fall a Buiday | Sample 228 3 50 5 S10. or.160 151200 Date Code BETS EOE) Tau 3200 3201 10,008 TH01- 35,09 aL 40; 600 QG-03-F01 D185 |-P and Final Insp'n Record Form Rev:21 July 2021 : Record Retention for complete Forms defined in Procedure 39-53 Code 03 Thermoswitch Test Data Customer Name Customer PIN. Fenwal PIN. Work ASIA ASIA 17343-124 17343-124 Order 946513, 046513 Set Temp ) 325 325 Tol Plus Minus Number (FY 8 8 Tol Fy 8 8 42511 42512 Time Stamp System Block ‘Make Number Number Temp 20220502185425 4 20220502185449 4 1 2 326.67 324.05 5/2/2022 3:28:18 PM Max Max Test MM MB Status 065 277 PASS 024 2.41 PASS Kido-Fonwal, ne UTC Building & Indust Systems 400 Main Steet Ashland, Ma 01721 ATTESTATION of CONFORMITY This is to dectare that the following components are designed and manufactured in accordance with Annex II of Directive 2014/34/EU. ‘The manufacturer attests on their own responsibility that the apparatus has been constructed in accordance with the principles of good engineering in safety matters and that any routine verification and. test required by clause 27 of EN 60079-0:2012 have been performed. Manufacturer: Test Faci Kidde-Fenwal, Inc. Intertek Testing & Certification Ltd 400 Main Street Intertek House, Cleeve Road Ashland, MA 01721 Leatherhead, Surrey, KT22 758 USA United Kingdom Product Description: Heat Activated Detector made from welded stainless steel that forms a hermetic seal around the switch contacts. © is cxnouese Model 17343-124 Heat Detector. Temperature Ranges: ‘325°F (163°C), 425°F (218°C) 00°F (316°C), 725°F (385°C) Certificate No. ITSO3ATEX41211U Attestation is based on Compliance with the following Standards EN 60079-0:2012: Explosive Atmospheres Part 0 - General requirements EN .60079-15:2010. Explosive Atmospheres Part 15 - Equipment Protection by Type of Protection “n" Authorizing Agent: Paul Fun Paul Finn, Fenwal Controls, Certification/Applications Engineer Issuance Date: 25 October 2016. Document Part Number 06:257564-001 Rev AA 17343-124 Installation Instructions For Fire/Overheat Detector DESCRIPTION ‘The Fire/Ovetheat Detector, shown in Figure 1, monitors for fre ‘and overheat conditions. Itcan be used in areas where there are usually very high temperatures. “The detector is made from welded stainless steel and is completely sealed, Itis not repairable and cannot be disassembled. The detector is set to a specified alarm temperature when itis made atthe factory and the temperature cannot be adjusted. “The detector electrically connects to its related equipment through two terminal posts with threads inside. Stainless steel screws attach the wiring from the related equipment to the two terminals. The detector mechanically attaches to the monitored ‘rea by the 3/4-14 National Pipe Thread (NPT) area location on the head of the detector. & part of the head contains 1-1/8 in. hex that has data about the detector recorded on the hex’s Rat surfaces with an electro-etch device. See Figure 1 and 2 below. Figure 1.Fire/Overheat Detector Figure 2, Detector Internal View SCHEDULE OF LIMITATIONS FOR EX COMPONENTS: “The detector must be mounted in a suitably TEC Ex certified enclosure that complies with the appropriate requirements for zone 2 applications. ‘Maximum surface temperature is dependent on ambient temperatures and must be determined in the final assembly installation. The temperature rise ofthe outside ofthe shell does rot exceed 2°C above ambient when carrying the rated 0.58 + 10%. CONTROLS 06-237241-002 November 2021 “The minimum data shown on a detector Is a5 follows: > Manufacturer's name and address: Fenwal Controls 400 Main Street, Ashland MA 01721 USA + Part Number: 17343-124-XXKF (where the 200 5 the set-point in degrees Fahrenhelt) + Date Code: KXVY (where 10¢=year, YY=week) + Rating: OSA, 125 VDC = Marking: ‘Korean Cart, # 14-KB4B0-07490 Ex AC HC TS 7 TIGEACHC TC asec = Tas +4405°C TTSOBATEX#I211U ExnC HC Ge SA5%C 5 Ta 5 2440.5°C TEC EXETL 12.0008 ‘Cas 1, Divison 1, Groups BCD sa: 159064 UL: €139563 UL Installation Requirements: ‘The unit must be attached to a UL Listed outlet box for use in at least the same Classes and Groups as marked on the nameplate, having a threaded opening with No. 3/4-14 NPT threads for mounting, The outlet box shall have a maximum internal volume OF 10 cubic inches and conduit opening(s) designed to accept Conduit not larger 3/4 inch. The unit shal be threaded to the 3/ 2:14 NPT thread at least five ful threads engagement.” Joint Between Hub and Enclosure - Threaded metal-to-metal joint ‘Minimum five full thread engagement CSA Installation Requirements: ‘To be Certified, the overheat detector must be assembled to 2 SA Certified junction box. The overall Hazardous Location Designation is governed by the Hazardous Location Rating of the junction box and not exceeding Cass I, Division 1 Group B ratings.

You might also like