Bracing calculation

Width of the building 19.82 m 19.82 m


Height of Building 7.5 m 7.5 m
Bay Spacing 7.6 m 7.6 m
Wind Force 0.875 kN/m^2 0.875 kN/m^2
End Zone Width 1.982 m 1.982 m
Co-efficent for end zone 1.2 1.2
co-efficent for the interior zome 0.8 0.8
Width of End Zone 1.982 1.982
Area for End Zone 15.06142 15.06142
Area for Interior Zone 64.17399 64.17399

Total force on Bracing 60.74 kN 60.74 kN


Force on each side wall 30.37 kN 30.37 kN

No of Brace Bay 2 2
Force on Each Brace Bay 15.18407 kN 15.18407 kN

Force on base plate 14.98428 kN vertical 14.98428 kN

INTERMEDIATE 30.36814
29.96856
39.64 m 10 m 9.782 m
7.5 m 9 m 9 m
7.6 m 7.6 m 7.6 m
0.875 0.875 kN/m^2 0.875 kN/m^2
3 m 1 m 0.9782 m
1.2 1.2 1.2
0.8 0.8 0.8
3 1 0.9782
22.95 9.05 8.851644
145.3416 37.2 36.36345

125.84 kN 35.54 kN 34.75 kN


62.92 kN 17.77 kN 17.37 kN

2 1 2
31.45916 kN 17.77125 kN 8.68716 kN

vertical 31.04522 kN vertical 21.0449 kN vertical 10.28743 kN

INTERMEDIATE 26.45841
31.33233