Laboratory

Fume Hoods & Enclosures

• Protector ClassMate Laboratory Hoods


® ®
• Basic ™ Laboratory Hoods
• Fiberglass 30 Laboratory Hoods • Protector XVS ™ Ventilation Stations
®

• Protector Demonstration Hoods


®
• Canopy Hoods
Protector ClassMate Laboratory Hoods
® ®

Features & Benefits

The patented* Protector ClassMate Laboratory Hoods are students using the hood. The clear back does not obstruct visibility
designed to meet the needs of instructional laboratories. Clear when hoods are placed back-to-back in an island configuration.
back and sides and taller front viewing window provide enhanced Protector ClassMate Hoods are offered in 4', 5' and 6' widths.
visibility for conducting chemistry demonstrations or observing Models with combination sashes are also available.

Durable and attractive By-pass airflow design Performance tested to Front panel may be easily Streamlined corner posts
frame is glacier white ensures relatively stable face ASHRAE 110. removed for lamp replace- provide maximum visibility
powder-coated steel velocities. ment and access to electrical and working area.
and aluminum. supply connections.
Static viewing panel above
Energy-efficient, rapid-start the sash frame creates a
fluorescent lighting is located 39" viewing height, permit-
behind a laminated safety ting the hood to be mounted
glass shield and outside the in a low or high position to
hood interior for corrosion- accommodate persons of dif-
resistance and easy replace- ferent heights and still maintain
ment. Contact Labconco the same visual accessibility.
for ordering information on
Anti-racking vertical-rising
explosion-proof lighting.
sash for smooth operation
may be raised from closed to
Ergonomic 5° angled sash 29" fully open height from the
and panel allow closer, more work surface for loading and
comfortable viewing, without cleaning. A sash stop limits
glare. the working height to 18" to
help conserve energy. Exhaust
volume and blower sizing are
Clear, tempered safety glass based on the 18" height. When
sash, viewing panel, sides, raised, the sash does not
back and baffle provide extend above the fume hood.
maximum visibility. All glass
components except vertical- Combination horizontal
rising sashes are removable sliding/vertical-rising sashes
for cleaning. Laminated safety are provided on
glass and solid composite some models.
sides and back are also avail- Two sets of inte-
able. Contact Labconco for gral sash stops
ordering information. prevent raising
the vertical sash
Color-coded service fixtures above the half-
for gas, air, water, vacuum open (15") and fully-closed
and other services have positions unless manually
remote controls for use defeated by the operator.
regardless of sash position.
Four service fixtures are pre- Pre-wired electrical compo-
plumbed on fixtured models. nents. Fluorescent lights and
Each hood is factory prepared switches are factory-wired
for up to 8 service fixtures to the hood’s junction boxes.
(four controlled from the front Two electrical duplex recep-
of the hood and four from the tacles are factory-wired on
base cabinet). fixtured models.

Tissue screen located


Baffle directs airflow to Low profile trough below Interior cover plates allow Ergonomic air foil allows directly below the exhaust
the rear of the interior to air foil contains spills. The easy accessibility to plumbing air to sweep the work surface outlet prevents debris from
provide efficient airflow. For trough is the same depth as from the front and inside of for maximum containment. potentially damaging the
cleaning, the entire baffle may the work surface (1.25") and the hood. Clean-Sweep** airflow remote blower.
be removed or upper baffle requires no cabinet overhang. openings pull inflow air from
tilted up and the lower baffle The air foil pivots up for under the air foil so that clean Large interior working
ETL-listed. Hoods carry the
tilted down. cleaning. air continually flows over the depth of 26" and height
ETL mark signifying that they
air foil creating a constant of 48" provide ample space
conform to UL 61010-1 and
barrier of protection from to conduct experiments.
1805 and CAN/CSA C22.2
contaminants.
No. 61010-1.

* U.S. Design Patent No. 472,645


Exclusive Feature ** U.S. Patent No. 6,461,233

2
Protector ClassMate Laboratory Hoods
® ®

behind the front panel.


All models conform to
the following regulations
and standards:
• CFR 29, Part 1910
• SEFA 1-2010
• NFPA 45-2011
• ASHRAE 110-1995
• ANSI Z9.5-2011
• UL 61010-1
• CAN/CSA C22.2 No. 61010.1
• UL 1805
• SEFA 8-2010, Cabinet Surface Finish Tests
Models S15388, S15390,
5' Protector ClassMate Combination Sash S15392, 6971401, 6971501 and
Laboratory Hood 6971501 is shown with
SpillStopper Work Surface S15397, Protector 6971601 feature:
Solvent Storage Cabinet 9902200 and Protector
Acid Storage Cabinet 9901200. Blower,
• Four pre-plumbed service fixtures with
ductwork, work surface and base cabinets forged brass valves; three with 0.25"
must be ordered separately.
copper tubing for use with cold water,
Requires air and vacuum, and one with 0.25"
Ductwork brass tubing for use with gas. Inlet
and
Blower tubing is not provided.
4' Protector ClassMate Laboratory Hood S15388 is shown with SpillStopper • Two pre-wired 115 volt, 15 amp
Work Surface S15393 and Protector Acid Storage Cabinet 9901000. Blower,
ductwork, work surface and base cabinet must be ordered separately. electrical duplex receptacles.

39" high visibility. Models 6971401, 6971501


All models feature:
and 6971601 also feature:
• Sash stop at 18" height from work
• Patented* design. • Left-side mounted cold water rigid
surface (60% open). Fully open sash is
• Glacier white powder-coated steel and gooseneck faucet in place of standard
29" from work surface.
aluminum frame. service fixture.
• Ergonomic air foil with aerodynamic Models series 69714, 69715 and • Pre-wired digital airflow monitor.
Clean-Sweep** airflow openings. 69716 also feature:
• Combination horizontal-sliding/ Required accessories not included:
• Low profile, ADA-compliant spill trough
vertical-rising sashes that allow the • Remote Blower.
that requires no cabinet overhang.
operator to use the hood with sashes • Ductwork.
• Clear, 1/4" thick, tempered safety glass
half open either horizontally or vertically. • Work Surface. See page 5.
sides, back and removable baffle.
Sash stops at fully closed and 15" height • Base Cabinet.
• Pre-wired fluorescent lighting, light
from work surface (50% open). Sash Optional accessories for on-site
switch and blower switch for 115 volt,
stops at the 50% open (15") and fully- installation include:
60 Hz, 15 amp operation.
closed positions along with a sash
• Tissue screen located directly below • Distillation Grid Kits.
pocket that blocks the upper by-pass
exhaust outlet. • Guardian Airflow Monitors.
and reduces amount of air exhausted.
• Removable front panel and interior • Rear Finish Panel Kits.
• Highly visible yellow air foil with
cover plates for access to plumbing and recessed sash track. • Service Fixtures.
electrical wiring.
• 5° angled, tempered safety glass,
• Powder-coated steel 8.6" ID exhaust Contact Labconco at 800-821-5525 or
1/4" thick sash and stationary viewing 816-333-8811 for blower sizing assistance
connection. panel** to provide viewing height of and ordering information on accessories not
Models S15387, S15388, 39" for visual accessibility regardless included in this brochure.
S15389, S15390, S15391 and of mounting height.
S15392 also feature: • Powder-coated steel sash pocket
• By-pass airflow design.
• 5° angled, tempered safety glass
viewing window and 3/16" thick sash * U.S. Design Patent No. 472,645
with anti-racking shaft and powder-
coated aluminum frames that provides Exclusive Feature
Heights of switches, electrical receptacles and service
fixtures meet requirements of ADA.
3
Ordering Information & Dimensional Data
Protector ® ClassMate ® Laboratory Hoods

Total Exhaust CFM and Static Pressure Total Exhaust CFM and Static Pressure at 50%
at 18" sash opening height (60% open)* sash opening height horizontally or vertically
Catalog Number 100 fpm S.P. 80 fpm S.P. 60 fpm S.P. Catalog Number 100 fpm S.P. 80 fpm S.P. 60 fpm S.P.

S15387, S15388 570 0.24" 460 0.16" 340 0.09" 6971400, 6971401 470 0.16" 380 0.11" 280 0.06"
S15389, S15390 730 0.39" 590 0.26" 440 0.14" 6971500, 6971501 550 0.22" 440 0.14" 330 0.08"
S15391, S15392 890 0.51" 710 0.33" 540 0.19" 6971600, 6971601 680 0.30" 550 0.20" 410 0.11"
*Contact Labconco for other sash opening height data.

Nominal Catalog Fluorescent Service Electrical Digital Shipping


Width Number Lamps Fixtures Duplexes Monitor Weight lbs./kg

4 Feet S15387 2 ea. 30 watt None None No 400/181


4 Feet S15388 2 ea. 30 watt 4 2 No 400/181
4 Feet 6971400 2 ea. 30 watt None None No 485/220
4 Feet 6971401 2 ea. 30 watt 4* 2 Yes 485/220
5 Feet S15389 2 ea. 40 watt None None No 460/209
5 Feet S15390 2 ea. 40 watt 4 2 No 460/209
5 Feet 6971500 2 ea. 40 watt None None No 570/259
5 Feet 6971501 2 ea. 40 watt 4* 2 Yes 570/259
6 Feet S15391 2 ea. 40 watt None None No 550/249
6 Feet S15392 2 ea. 40 watt 4 2 No 550/249
6 Feet 6971600 2 ea. 40 watt None None No 680/308
6 Feet 6971601 2 ea. 40 watt 4* 2 Yes 680/308
*Includes one rigid gooseneck faucet for cold water.
8.6" (21.9 cm) ID 8.6" ID
Exhaust Collar Electrical
1.25" (3.2 cm) Exhaust Collar 1.25"
B with Tissue Screen B Junction Boxes
8.6" (21.9 cm) ID 0.5" (1.3 cm) Electrical withA*
Tissue Screen
8.6" (21.9 cm) ID
B* 0.5" C*
Under Cover
D* E*
Exhaust Collar Junction Boxes
1.25" (3.2 cm) Under Cover Exhaust Collar 1.25" (3.2 cm)
7.5" B with Tissue Screen 2.0" Electrical S15387,
B S15388 48.0 (121.9)
with Tissue Screen 24.0 (61.0) 45.0
2.0" REF(114.3) N/A 25.75 (65.4)
(19.2 cm) 0.5" (1.3 cm) 7.5" Boxes
(5.1 cm)Junction 0.5" (1.3 cm) Electrical
REF Under Cover Junction Boxes
7.5" 2.0"7.5" 6971400, 6971401 48.0 (121.9) 24.0 (61.0) Under
2.0" 45.0 Cover
Plumbing
(114.3) N/A 26.25 (66.7)
Plumbing(19.2 cm) (5.1Plumbing
Plumbing
(19.2 cm)
cm) (5.1 cm) Inlet
Inlet Lines REFInlet
Inlet Lines REF 57.0 Lines (144.8)
S15389, S15390 60.0 (152.4) 30.0 (76.2) N/A 25.75 (65.4)
Plumbing 23.75" REF Lines 23.75" REF
Plumbing Plumbing Plumbing
Inlet Lines 6971500, 6971501 60.0 (152.4) 30.0 (76.2) Inlet57.0
Inlet Lines Inlet Lines Lines (144.8) 26.0 (66.0) 26.25 (66.7)
23.75" REF 23.75" REF
S15391, S15392 72.0 (182.9) 36.0 (91.4) 69.0 (175.3) N/A 25.75 (65.4)
FRONT FRONT
6971600, 6971601 72.0 (182.9) 36.0 (91.4) 69.0 (175.3) 32.0 (81.3) 26.25 (66.7)
TOP (AllFRONTModels) FRONT
27.7"
*Inches (70.2 cm)
(centimeters) Fluorescent
A
Lights
27.7" (70.2 cm) 7.0" Fluorescent 27.7" cm)
27.7" (70.2
A A(17.8 cm) Fluorescent
Fluorescent
A Lights Lights
Lights
7.0" 7.0"
(17.8 cm) Digital 7.0"
(17.8 cm)
12.5" Airflow
(31.8 cm) Monitor
10.0" (25.4 cm) Viewing Panel 48.0" (on fixtured
(121.9 cm) 12.5" 59.0" models) 12.5"
115 Volt, 20 Amp Gooseneck Faucet60.25" Interior (31.8 cm) (149.9 cm) (31.8 cm)
10.0" (25.4 cm) 29.0"
Viewing Panelcm) (on fixtured models) (153.0 cm) 10.0"10.0" 48.0"
Height
(25.4 cm) Viewing Panel 48.0"
Duplex Electrical (73.7
Sash Opening
(25.4(121.9 cm) Panel 44.5" 59.0"
cm) Viewing
(121.9 cm) 59.0"
Receptacle 60.25" Interior (113.0 cm) cm)
(149.9 48.0" Interior 59.0"cm)
115 Volt, 20 Amp 115 Volt, 20 Amp Sash to 60.25"
60.25" Interior (149.9
(one on Electrical
each side 29.0" (73.7 cm) 115 Volt, 20 Amp(153.0 cm) HeightBaffle 39.0" (99.1 cm)
44.5" (153.0 cm)
Duplex 39.0" (99.1 cm) Duplex Electrical 29.0" (73.7 cm) Viewing Height Height Height 44.5"
on fixtured models) Sash Opening
18.0" (45.7 cm) Duplex Electrical 25.75"
SashtoOpening D (113.0 cm)
Receptacle Viewing Height Receptacle
Receptacle Sash (113.0 cm)
Sash Stop Height to Work Surface (65.4 cm) Sashtoto
Sash
(one on each side C (one(one on each
on each side side Baffle Baffle
Service fixture 39.0" (99.1 cm) 25.75" 39.0" (99.1 cm) Baffle
on (two
fixtured models) 18.0" (45.7 cm) Viewing Height on fixtured models) 18.0" (45.7 cm) 25.75"
on each side Sash Stop Height on fixtured models) cm)(38.1 cm) Viewing Height
(65.415.0"
to Work Surface Sash Stop Height Sash Stop Height to Work Surface
26.25"cm)
(65.4
on fixtured
Service models)
fixture C C
Service fixture
Service Fixture C 2.0" (5.1 cm)
(two on each side FRONT (two(two on each
on each sideside 1.25" (3.2 cm) Trough
Plumbing
on fixtured models) on fixtured
on fixtured models)
models) 2.0" (5.1 cm) Inlet Linescm)
2.0"Shown)
(5.1 2.0"
    FRONT
23.75"
1.25" (3.2(60.3
2.0"32.25"
(5.1 cm)
cm)(4' Single Sash Not
cm) Trough
FRONT
(81.9 cm) Plumbing 1.25" 1.25" Trough
(3.2 cm) Trough 2.0" (5.1 cm)
Plumbing
Plumbing
FRONTInlet Lines 2.0"(5.1 cm)
2.0" Inlet
Inlet Lines
FRONT 23.75" (60.3 cm)
SIDE
32.25" (81.9 cm)
FRONT 23.75"23.75"
(60.3 cm)
Lines
32.25"32.25"
(81.9 cm)
(Models S15387, S15388, S15389, (Model
SIDE
series 69714,
SIDE
S15390, S15391 and S15392) 69715 and 69716) SIDE
SIDE

(All Models)

Contact Labconco at 800-821-5525 or 816-333-8811 for detailed AutoCAD drawings.

4
Accessories
Protector ClassMate ® Laboratory Hoods
®

Rear Finish Panel Kits


The panel hides the hood’s interior components. Recommended when
hood is mounted on a casework island (and exposed on the back), each
kit includes a glacier white powder-coated steel panel to provide a finished
appearance for the rear of the hood.

Nominal Dimensions Shipping Wt.


Catalog # Width (w x h) lbs./kg
6987300 4 Feet 43" x 9.5" 20/9
SpillStopper ™ Work Surfaces 6987301 5 Feet 55" x 9.5" 25/12
Molded from a special formulation of corrosion-resistant epoxy 6987302 6 Feet 67" x 9.5" 30/14
resins. Dished and contoured to conform to the interior liner of
Protector ClassMate Laboratory Hoods. May be ordered with an oval
cupsink cutout in the right or left rear. Cupsink is sold separately.
See below. See page 24 for deck-mounted accessories, which require Distillation Grid Kits
custom cutouts. Kits include stainless steel rods,
connectors, instruction sheet and
Catalog # Description Shipping Wt. drill template.
lbs./kg
S15393 4' w x 25.9" d, no cutouts 110/50
S15394 4' w x 25.9" d, cupsink cutout, left rear 110/50
S15395 4' w x 25.9" d, cupsink cutout, right rear 110/50
S15396 4' w x 25.9" d, cupsink cutouts, left and right rear 110/50 Nominal Shipping Wt.
S15397 5' w x 25.9" d, no cutouts 150/68 Catalog # Width lbs./kg
S15398 5' w x 25.9" d, cupsink cutout, left rear 150/68
6973300 4 Feet 15/7
S15399 5' w x 25.9" d, cupsink cutout, right rear 150/68
6973301 5 Feet 20/9
S15400 5' w x 25.9" d, cupsink cutouts, left and right rear 150/68
S15401 6' w x 25.9" d, no cutouts 205/93 6973302 6 Feet 25/11
5.1" 2.5" (6.4 cm)
S15402 6' w x 25.9" d, cupsink cutout,(12.9
left cm)
rear 205/93
S15403 6' w x 25.9" d, cupsink cutout, right rear 205/93
S15404 6' w x 25.9" d, cupsink cutouts, left and right rear 6.6" (16.8 cm)
205/93
9743203 Guardian™ 335 Digital Airflow Monitor Kit
For use on Protector ClassMate Laboratory Hoods only.
25.9"
Dimensional Data 20.4" (65.7Monitors
cm) and alerts the operator to low airflow condi-
(51.8 cm) tions. Includes face plate with circuit board, electrical
5.1" 2.5" (6.4 cm)
(12.9 cm) 5.1" 2.5" (6.4 cm) 1.0" power pack, vinyl tubing, side wall flow tube adapter
(12.9 cm) (2.5 cm)
and wiring instructions. From the monitor’s face plate,
3.0" (7.6 cm)
6.6" (16.8 cm) the user can easily select and calibrate a setpoint
6.6" (16.8 cm) 0.5"
(1.3 cm) 2.25" between 50 and 250 fpm using a velocity meter. An
1.25" (3.2 cm) (5.7 cm)
Left Rear 2.25"
Right(5.7
Rearcm) LCD displays actual face velocity. If the hood’s face
25.9"
20.4" Oval Cupsink Cutout Options (65.7 cm) 25.9" velocity falls below the programmable setpoint, an audible alarm sounds
(51.8 cm) 20.4" (65.7 cm)
(51.8 cm) 3.0" x 6.0 (7.6 x 15.2 cm)" and the LOW indicator glows red. The TEST RESET switch, when
1.0" pressed, mutes the audible alarm. The EMERG. PURGE switch, when
(2.5 cm) 1.0"
(2.5 cm) configured and pressed, can be used to activate a relay to open a hood
3.0" (7.6 cm) 1.25"
3.0" (7.6 cm) damper (not included). Requires cutout in upper right portion of
0.5" (3.2 cm) 0.25" (0.6 cm) Dish
(1.3 cm) 0.5" 2.25" front panel.
1.25" (3.2 cm) 2.25"
2.25" (5.7 cm)
(1.3 cm)
2.25" (5.7 cm)
1.25" (3.2 cm) TOP (5.7 cm)
(5.7 cm)
0.25" (0.6 cm)
Radiused Front Edge Only
9743204 Guardian™ Jr. Airflow Monitor Kit
For use on Protector ClassMate Laboratory Hoods only.
1.25" Monitors and alerts the operator to low airflow condi-
(3.2 cm) 1.25"
(3.2 cm) 0.25" (0.6 cm) Dish tions. Includes face plate with circuit board, electrical
0.25" (0.6 cm) Dish
power pack, vinyl tubing and airflow tube adapter. From
FRONT SIDE the monitor’s face plate, the user can easily select and
0.25" (0.6 cm)
Radiused Front0.25"
Edge(0.6
Onlycm) calibrate a setpoint between 30 and 250 fpm using a
Radiused Front Edge Only
velocity meter and a screwdriver. If the hood’s face
4005200 Oval Polypropylene Cupsink velocity falls below the setpoint for more than 6 sec-
Mounts in work surface with cupsink cutout. onds, an audible alarm sounds and the ALERT indicator glows red. The
3" x 6". 1.5" National Pipe Straight Mechanical thread. TEST RESET switch, when pressed, mutes the alarm. Requires cutout
Shipping weight 4 lbs. (1.8 kg) in upper right portion of front panel. Shipping weight 6 lbs. (2.7 kg)

5
Basic 47 Laboratory Hood with built-in blower S51259MF is shown with Flat
Requires
Ductwork and Solid Epoxy Work Surface S28132 and Protector Acid Storage Cabinet 9901000.
Blower
Inset: Basic 70 Laboratory Hood S28127 is shown with Flat Solid Epoxy Requires
Work Surface S28133 and two Protector Standard Storage Cabinets 9900100. Ductwork
Basic Laboratory Hoods

Features & Benefits

Basic 47 and 70 Laboratory Hoods are designed for modular Constructed of powder-coated steel, Basic Hoods are economi-
laboratories, classrooms and light duty applications where safe cal and have a smaller overall height and depth than traditional
ventilation is required. hoods so they fit in areas with low ceilings or narrow aisles.
Choose from 4' and 6' widths.

Front panel may be removed Versatile blower mounts on CE mark*. Contact Labconco Two-piece baffle is adjustable.
for access to blower and elec- top of the hood liner or in a for specific 230 volt, 50 Hz
trical connections. remote location. Hoods are also models that conform to CE
available without blower. (European Community) require- The right side fixture panel is
ments for electrical safety and factory-prepared for up to three
Durable and attractive electromagnetic compatibility. color-coded service fixtures, one
exterior is glacier white duplex electrical receptacle and
powder-coated steel. an airflow monitor.

Vapor-proof incandescent
lighting illuminates the
interior. Explosion-proof
models include an explosion-
proof incandescent light fixture
(bulb not included).

Top of the hood liner is


factory-prepared to accom-
modate two customer-
supplied apparatus rods.

Vertical-rising tempered
safety glass sash protects
the operator while providing
excellent visibility.

ETL-listed. Hoods carry the


ETL mark signifying that they
are certified to UL 61010-1 and
CAN/CSA C22.2 No. 61010.1.

The curved air foil directs


airflow into the hood to min-
imize turbulence and ensure
fume containment. The foil lifts
off for cleaning.

Unassembled models
available. Components fit into
a carton less than one half its
assembled size. The compact
The right interior wall is Durable powder-coated Pre-wired electrical compo-
container is more economical to
factory-prepared to accom- 16 gauge steel liner resists nents. Incandescent lighting
ship and store than assembled
modate an accessory cupsink chemical degradation. and switches are factory-wired
hood cartons and transports
and turret (sold separately). to the hood’s junction box.
readily to remote locations.
Explosion-proof models are
Assembly is simple and fast.
furnished without switches
Unassembled models are
Compact dimensions accom- and wiring as these must
not pre-wired.
modate tight installations. conform to varying local
The 48" height, 53" with built- codes.
in blower, makes it ideal for
Performance tested to
laboratories with lower ceiling * Contact Labconco for specific models.
ASHRAE 110.
heights. Overall depth of 25"
makes it adaptable to shallow Exclusive Feature
cabinetry.
7
Basic Laboratory Hoods

Explosion-proof models feature:


• Explosion-proof incandescent light
fixture. (Requires installation. Bulb not
included.)
• Furnished without switches and
wiring as these must conform to
varying local codes.

Models with blower


module feature:
• Belt-driven blower with adjustable
sheave.
• Powder-coated steel base and housing.
• Corrosion-resistant coated aluminum
impeller.

Unassembled models feature:


• Basic 47 Hood carton dimensions:
51" w x 39" d x 14.5" h.
• Basic 70 Hood carton dimensions:
74" w x 39" d x 14.5" h.
• Blower carton dimensions
(if applicable): 20" w x 28" d x 16" h.

Required accessories not included:


• Blower.†
• Ductwork.
Requires • Work Surface. See page 24.
Ductwork
• Base Cabinet or Stand.

Optional accessories for on-site


installation include (see page 11):
Basic 47 Laboratory Hood S51259MF is shown with Flat Solid Epoxy Work Surface S28132 and
• Service Fixture Kits.
Protector Acid Storage Cabinet 9901000. Blower module is included. Ductwork, work surface
and base cabinet must be ordered separately. • Electrical Duplex Kits.
• Guardian Airflow Monitor Kits.
All models feature: All models conform to
• Cupsink and Turret Kit.
• By-pass airflow design. the following regulations
and standards: • Sash Stop Kit.
• Curved air foil that lifts off for cleaning.
• CFR 29, Part 1910 • Right Side Finish Panel Kit.
• Glacier white powder-coated, 16 gauge
steel exterior and interior. • SEFA 1-2010
• Two-piece adjustable baffle. • NFPA 45-2011
• ASHRAE 110-1995
• 3/16" thick tempered safety glass.
vertical-rising sash with powder-coated • ANSI Z9.5-2011*
aluminum sash handle. • UL 61010-1 Contact Labconco at 800-821-5525 or
• Removable front panel for access to • CAN/CSA C22.2 No. 61010.1 816-333-8811 for blower sizing assistance
electrical wiring. • UL 1805 and ordering information on accessories not
• Factory-prepared right side fixture • SEFA 8-2010, Cabinet Surface Finish Tests included in this brochure.
panel for up to three service fixtures, • CE Conformity Marking
one duplex electrical receptacle and (220 volt models)**
one airflow monitor (fixtures, receptacle *Does not apply to models with blower module.
and monitor not included). Vapor-proof models feature: **Contact Labconco for specific models.
†Many models include a blower module.
• Factory-prepared right interior wall for • Pre-wired 100-watt vapor-proof incan-
one cupsink and turret (cupsink and descent light, light and blower switches.
turret not included).
• Powder-coated steel 10.3" OD exhaust Heights of switches, electrical receptacles and service
connection. fixtures meet requirements of ADA.

8
Ordering Information & Dimensional Data
Basic™ 47 Laboratory Hoods

Basic 47 Hoods with Blower Module


Capable of overcoming a maximum external static pressure of .25" H2O at 720 CFM (100 fpm).
Overall dimensions: 47.0" wide x 25.0" deep x 53.0" high (with blower module mounted on top of hood).

Nominal Catalog Electrical Incandescent Blower Equivalent Assembly Shipping


Width Number Requirements Lamp Motor Resistance* Configuration Weight lbs./kg
10" dia. 12" dia.
4 Feet S51259MF 115 volts, 60 Hz Vapor-Proof 1/3 hp 100' 250' Fully Assembled 370/168
4 Feet 2247301** 220 volts, 50 Hz Vapor-Proof 1/2 hp 100' 250' Fully Assembled 370/168
4 Feet 2247500 115/230 volts, 60 Hz EP †
1/3 hp, EP 100' 250' Fully Assembled 375/170
4 Feet 2247501** 220 volts, 50 Hz EP † 1/3 hp, EP 100' 250' Fully Assembled 375/170
4 Feet 2246603 115 volts, 60 Hz Vapor-Proof 1/3 hp 100' 250' Unassembled 272/123
29/13††
4 Feet 2246604** 220 volts, 50 Hz Vapor-Proof 1/2 hp 100' 250' Unassembled 272/123
29/13††
4 Feet 2246605 115/230 volts, 60 Hz EP † 1/3 hp, EP 100' 250' Unassembled 272/123
41/19††
4 Feet 2246606** 220 volts, 50 Hz EP † 1/3 hp, EP 100'
Exhaust Duct 250'
10.3" OD Unassembled 272/123
(Hoods without Blower Module) 41/19††
3.25"
(8.3 cm)
10.1"
(25.7 cm)
Basic 47 Hoods for use with remote blower 25.0"
Static pressure loss does not exceed .35" H2O at 100 fpm (720 CFM). Overall dimensions:
(63.547.0"
cm) wide x 25.0" deep x 48.0" high.
Junction
Box
Nominal Catalog Electrical Incandescent 22.1" Assembly
24.9"
Shipping
Width Number Requirements Lamp (56.2 cm) Configuration
(63.2 cm) Weight lbs./kg
TOP
4 Feet S28126 100-115Exhaust
volts, 50/60 Hz
Duct 10.3" OD
Vapor-Proof (Hoods without Fully Assembled
blower module) 275/125
(Hoods without Blower Module)
4 Feet 2247401** 208-230 volts, 50/60 Hz Vapor-Proof
3.25" Fully Assembled
10.4"
275/125
(8.3 cm) Exhaust Duct 10.3" (26.2 cm) OD
(Hoods with Blower Module) Unassembled (26.4 cm)
4 Feet 2246600 100-115
10.1" volts, 50/60 Hz Vapor-Proof 3.25" 272/123
(25.7 cm) (8.3 cm)
4 Feet 2246601** 208-230
25.0"
volts, 50/60 Hz Vapor-Proof Unassembled 272/123
(63.5 cm) 10.1" 5.9" (14.9 cm)
4 Feet 2246602 115/230 volts, 50/60 Hz Junction EP †
(25.7 cm) Unassembled 272/123
Box
25.0"
(63.5 cm) † Junction
††
EP = explosion-proof * Maximum length of straight duct to achieve 100 fpm face velocity 24.9"** International electrical configuration
22.1" Bulb not included Shipping weight of separate blower carton
(56.2 cm) (63.2 cm) Box
TOP 22.1" 24.9"
(Hoods without blower module) (56.2 cm) (63.2 cm)
TOP
Exhaust Duct 10.3" (26.2 cm) OD 10.4" (Hoods with blower module)
Exhaust Duct 10.3" OD (26.4 cm)
(Hoods without Blower Module) (Hoods with Blower Module) 3.25"
3.25" (8.3 cm) Incandescent Light
(8.3 cm) Blower Module (8.75"/22.2 cm high)
10.1" 10.1" 5.9" (14.9 cm)
(25.7 cm) (25.7 cm)
25.0" 25.0"
(63.5 cm) Junction (63.5 cm) 53.0"
Junction
Box Box 48.0" (134.6 cm)
(121.9 cm) 11.9"
26.0" (66.0 cm) Sash (30.3 cm) 36.0"
22.1" 24.9" 22.1" 24.9" Opening/27.1" (68.9 cm) (91.4 cm)
(56.2 cm) (63.2 cm) (56.2 cm) (63.2 cm) Viewing Ht. to Work Surface 18.5" 29.0"
(47.0 cm) (73.7 cm)
TOP
TOP TOP
TOP Sash Frame
(Hoods without blower module) 41.25" (104.8 cm)
(Hoods without blower module) (Hoods
(Hoods with blower
with blower module)
module) Sash Opening To Baffle

10.4" Incandescent Light


Exhaust Duct 10.3" (26.2 cm) OD Blower Module (8.75"/22.2 cm high) 43.2" (104.8 cm) Inside
(Hoods with Blower Module) (26.4 cm)
3.25" 47.0" (119.4 cm)
See page 11 for blower module detail. (8.3 cm) FRONT
FRONT SIDE SIDE
10.1" 5.9" (14.9 cm)
(25.7 cm) 53.0"
48.0" 11.9" (134.6 cm)
25.0" (121.9 cm)
(63.5 cm) 26.0" (66.0 cm) Sash (30.3 cm) 36.0"
Junction Opening/27.1" (68.9 cm)
Box (91.4 cm)
Viewing Ht. to Work Surface 18.5" 29.0"
(47.0 cm) (73.7 cm)
22.1" 24.9" 41.25" (104.8 cm) Sash Frame
(56.2 cm) (63.2 cm) Sash Opening To Baffle
TOP
(Hoods with blower module) 43.2" (104.8 cm) Inside
47.0" (119.4 cm)
Incandescent Light
Blower Module (8.75"/22.2 cm high) FRONT SIDE
9

53.0"
Ordering Information & Dimensional Data
Basic™ 70 Laboratory Hoods

Basic 70 Hoods with Blower Module


Capable of overcoming a maximum external static pressure of .23" H2O at 1120 CFM (100 fpm).
Overall dimensions: 70.0" wide x 25.0" deep x 53.0" high (with blower module mounted on top of hood).

Nominal Catalog Electrical Incandescent Blower Equivalent Assembly Shipping


Width Number Requirements Lamp Motor Resistance* Configuration Weight lbs./kg
10" dia. 12" dia.
6 Feet S28128 115 volts, 60 Hz Vapor-Proof 3/4 hp 45' 100' Fully Assembled 450/204
6 Feet 2246301** 220 volts, 50 Hz Vapor-Proof 3/4 hp 45' 100' Fully Assembled 450/204
6 Feet 2246500 115/230 volts, 60 Hz EP † 3/4 hp, EP 45' 100' Fully Assembled 455/206
6 Feet 2246501** 220 volts, 50 Hz EP † 3/4 Exhaust
hp, EP Duct 10.3"45'
(26.2 cm) OD100' Fully Assembled 455/206
(Hoods without Blower Module)
6 Feet 2246703 115 volts, 60 Hz Vapor-Proof 3/4 hp 45' 100'
3.25" Unassembled 426/193
(8.3 cm) 29/13 ††
10.1"
6 Feet 2246704** 220 volts, 50 Hz (25.7 cm)
Vapor-Proof 3/4 hp 45' 100' Unassembled 426/193
25.0" 41/19 ††
(63.5 cm) Junction
6 Feet 2246705 115/230 volts, 60 Hz EP † 3/4 hp, EP 45' 100' Box Unassembled 426/193
41/19 ††
6 Feet 2246706** 220 volts, 50 Hz EP † 3/433.6"
hp, EP 36.4" 100'
45' (92.4 Unassembled 426/193
(85.4 cm) cm)
41/19 ††
TOP
(Hoods without blower module)

Basic 70 Hoods for use with remote blower


Static pressure loss does not exceed .57" H2O at 100 fpm (1120 CFM). Overall dimensions: 70.0" wide x 25.0" deep x 48.0" high.
Exhaust Duct 10.3" (26.2 cm) OD 21.9"
Nominal Catalog Electrical Incandescent
(Hoods with Blower Module) (55.6 cm) Assembly Shipping
Width Number Requirements Lamp 3.25"Configuration Weight lbs./kg
(8.3 cm)
6 Feet S28127 100-115 volts, 50/60 Hz Vapor-Proof Fully Assembled 430/195
10.1"
6 Feet 2246401** (25.7Hz
208-230 volts, 50/60 cm) Vapor-Proof Fully Assembled 430/195
25.0" 5.9"
6 Feet S28129 100-115 volts,(63.5
50/60
cm) Hz Vapor-Proof Unassembled
(14.9 cm) 426/193
6 Feet 2246701** 208/230 volts, 50/60 Hz Vapor-Proof Junction
Unassembled 426/193
Box
6 Feet 2246702 115/230 volts, 50/60 Hz 33.6" EP

36.4" Unassembled 426/193
(85.4 cm) (92.4 cm)
EP = explosion-proof Exhaust Duct
* Maximum 10.3"
length (26.2 cm)
of straight ODto achieve 100 fpm face velocity
duct TOPconfiguration
** International electrical †
Bulb not included ††
Shipping weight of separate blower carton
(Hoods without Blower Module) (Hoods with blower module)
3.25"
Exhaust Duct 10.3" (26.2 cm)(8.3
OD cm)
10.1" (Hoods without Blower Module) Incandescent Light
(25.7 cm) 3.25" Blower Module (8.75"/22.2 cm high)
(8.3 cm)
25.0" 10.1"
(63.5 cm)
(25.7 cm) Junction
Box
25.0"
(63.5 cm) Junction 53.0"
33.6" 36.4" 48.0" (134.6 cm)
Box (20.3 cm) 11.9" 36.0"
(85.4 cm) (92.4 cm) 26.0" (66.0 cm) Sash Opening/ (30.3 cm) (91.4 cm)
TOP 27.1" (68.9 cm) Viewing Height to
33.6" 36.4" Work Surface 29.0"
(85.4(Hoods
cm) without blower module)(92.4 cm) 18.5" (73.7 cm)
(47.0 cm)
TOP
TOP 64.25" (163.2 cm) Sash Frame
(Hoods without
(Hoods without blower module)
blower module) Sash Opening To Baffle

21.9" 66.2" (168.1 cm) Inside


Exhaust Duct 10.3" (26.2 cm) OD
(Hoods with Blower Module) (55.6 cm) 70.0" (177.8 cm)
3.25"
Exhaust Duct 10.3" (26.2 cm) OD (8.321.9"
cm) FRONT SIDE
(55.6 cm) FRONT SIDE
(Hoods with Blower Module)
10.1" 3.25"
(25.7 cm) (8.3 cm)
25.0" 5.9"
(63.5 cm)10.1" (14.9 cm)
(25.7 cm)
Junction
25.0" Box5.9" See page 11 for blower module detail.
(63.5 cm) (14.9 cm)
33.6" 36.4" Junction
(85.4 cm) (92.4 cm) Box
TOP
TOP
33.6"
(Hoods with
(Hoods blower module) 36.4"
(85.4 cm) with blower module) (92.4 cm)
TOP Incandescent Light
Blower Module (Hoods with blower module) (8.75"/22.2 cm high)
10
Incandescent Light
Blower Module (8.75"/22.2 cm high)
Accessories
Basic™ Laboratory Hoods

Guardian™ Jr. Airflow Monitor Kits Guardian™ Digital Airflow Monitor Kits
Audible/visual alarm alerts user to low face velocity. An LCD displays average face velocity. Audible/visual
For installation in a factory-prepared cutout on upper alarm alerts user to low or high face velocity. For instal-
portion of right side fixture panel. Shipping weight 6 lbs. lation in a factory-prepared cutout on upper portion of
(3 kg) right side fixture panel. Shipping weight 6 lbs. (3 kg)

Catalog # Description Catalog # Description


9743208 Guardian Jr. Airflow Monitor for 115 volt, 60 Hz operation 9743207 Guardian Digital Airflow Monitor for 115 volt, 60 Hz operation
9743210** Guardian Jr. Airflow Monitor for 230 volt, 50 Hz operation 9743209** Guardian Digital Airflow Monitor for 230 volt, 50 Hz operation

Duplex Electrical Receptacle Kits Glass


Each kit includes duplex electrical receptacle, junction Sash
box and receptacle cover plate. For mounting on the 4965901 Sash Stop Kit
lower right side fixture panel. Electrical wiring is not Sash
Stop The Sash Stop restricts how far the sash may
included. be opened. This small plastic device may be
easily installed on the left side of Basic Hoods
Sash
Catalog # Kit Shipping Wt. Handle to restrict sash opening height. Shipping weight
0.5 lb. (0.2 kg)
4844400 115 volts, 20 amps AC 4 lbs. (2 kg)
4844401 115 volts, 20 amps AC, GFCI 4 lbs. (2 kg)

4852500 Cupsink and Turret Kit 4878600 Right Side Finish Panel Kit
Polypropylene cupsink, 3" x 6", and chrome Recommended. Includes a glacier white powder-coated steel panel to
turret mount on right side wall. Plumbing provide a finished appearance to the right side of the hood. The panel
pipe is not included. Shipping weight 0.5 lb. hides the exposed plumbing when service fixtures are installed. Not for
(0.2 kg) use with 4852500 Cupsink and Turret. Shipping weight 20 lbs. (9 kg)

Standard Service Fixture Kits


Each kit includes one remotely-controlled service fixture with 0.25" diameter valve and tubing, color-coded fixture knob and
color-coded hose connector. For mounting on the right side fixture panel. Shipping weight 4 lbs. (2 kg.)
Blower Module Detail
Knob/ Maximum Maximum
Catalog # Kit Tubing Valve Connector Flow Working
Color Rate Pressure*
8.5"
S28139 Cold Water (CW) Copper Brass (21.6 cm) 14.5" (36.8
Green 3.5cm)
GPM (13.2 LPM) 40 psi
S28136 Hot Water (HW) Copper Brass 9.9" Red 3.5 GPM (13.2 LPM) 40 psi
S28138 Deionized/ Stainless (25.1 cm)
Nickel-Plated/ White 3.5 GPM (13.2 LPM)
Blower Outlet 40 psi
Distilled Water (DI) Steel Stainless Steel 10.3"
20.5" (26.2 cm)
S28140 Vacuum (VAC) Copper Brass
(52.1 cm) Yellow 8.6 CFM OD 14.7 psi
4.25"
S28142 Air (AIR) Copper Brass (10.6 cm) Orange 23.7 CFM Blower Inlet 40 psi
10.9"
S28141 Gas (GAS) Brass Brass Blue 29.0 CFM (441 BTU/sec)
(27.6 cm) 40 psi
S28135 Nitrogen (NIT) Copper Brass Brown 24.1 CFM ID 40 psi
1.0" 23.0" (58.4 cm)
S28137 Argon (ARG) Copper Brass (2.5 cm) Gray 26.0" (66.0 cm) 20.2 CFM 40 psi
S28134 Steam (STM) Copper Brass Black 28.25" (71.8 cm) 0.5 LBM/min 40 psi
Blower Module Detail TOP
GPM = gallons per minute LPM = liters per minute CFM = cubic feet per minute BTU/sec = British thermal unit per second LBM/min = pounds mass per minute
* Maximum allowable pressure is 200 psi with a working pressure of 40 psi. ** International electrical configuration

8.5"
Blower Module Detail (21.6 cm) 14.5" (36.8 cm)
7.0"
9.9" (17.8 cm)
(25.1 cm) Blower Outlet 16.0"
10.3" (40.6 cm)
20.5" (26.2 cm)
(52.1 cm) OD
4.25"
(10.6 cm) Blower Inlet
10.9" 3.0" 14.5"
(27.6 cm) (7.6 cm) (36.8 cm)
ID FRONT SIDE
1.0" 23.0" (58.4 cm) FRONT SIDE
(2.5 cm) 26.0" (66.0 cm)
28.25" (71.8 cm)
TOP
TOP
11
Fiberglass 30 Laboratory Hoods

All models feature: Models 3030002 and 3030003:


• By-pass airflow design. • Designed for use with remote blower
• Durable glacier white powder-coated (not included).
steel exterior. • Static pressure loss does not exceed
• One-piece molded fiberglass interior 0.14" H2O at 100 fpm (310 CFM).
and pre-set baffle with flame spread • Pre-wired 100 watt, vapor-proof
index less than 25 per ASTM E-84. incandescent lamp, light and blower
• 3/16" thick tempered safety glass switches.
vertical-rising sash with powder-coated
aluminum handle. Models 3030004 and
• Pivoting air foil. 3030005 feature:
• Right side fixture panel factory-prepared • Built-in corrosion-resistant, explosion-
to accept up to three service fixtures, proof, direct drive exhaust blower
one electrical duplex and one airflow capable of overcoming a maximum
monitor (kits are sold separately). external static pressure of 0.12" H2O at
310 CFM (100 fpm).
• 6.7" ID fiberglass exhaust connection.
• Furnished without light,
All models conform to switches or wiring. Wiring must
the following regulations conform to local codes. (Explosion-
and standards: proof Light Fixture Kit is available.
See page 13.)
• CFR 29, Part 1910
• SEFA 1-2010 Required accessories not included:
• NFPA 45-2011 • Ductwork.
• ASHRAE 110-1995 • Work Surface. See page 24.
• ANSI Z9.5-2011* • Base Cabinet or Stand.
• UL 61010-1
Requires • CAN/CSA C22.2 No. 61010.1 Optional accessories for
Ductwork and
Blower • UL 1805 on-site installation include
• SEFA 8-2010, Cabinet Surface Finish Tests (see page 13):
• CE Conformity Marking (230 volt • Service Fixture Kits.
Fiberglass 30 Laboratory Hood 3030002 models)**
is shown with Flat Solid Epoxy Work • Electrical Duplex Kits.
Surface S28130 and Protector Standard Models 3030000 and • Guardian Airflow Monitor Kits.
Storage Cabinet 9900200. Remote blower,
ductwork, work surface and base cabinet 3030001 feature:
• Explosion-Proof Light Fixture Kit.
must be ordered separately. • Built-in corrosion-resistant, direct drive
Compact Fiberglass 30 Laboratory Hoods exhaust blower capable of overcoming
are designed for research, educational and a maximum external static pressure of Contact Labconco at 800-821-5525 or
0.12" H2O at 310 CFM (100 fpm). 816-333-8811 for blower sizing assistance
clinical applications requiring small work-
• Pre-wired 100 watt, vapor-proof and ordering information on accessories not
ing space and efficient fume removal. Like
incandescent lighting, light and blower included in this brochure.
the Protector Premier line, these hoods switches.
feature a corrosion-resistant, one-piece * Does not apply to models with built-in blowers.
**Contact Labconco for specific models.
molded fiberglass liner.
Ordering Information
Catalog Built-in Equivalent Electrical Vapor-Proof Dimensions Shipping
Number Blower Resistance** Requirements Lamp (w x d x h) Weight lbs./kg
6" dia. 8" dia.
3030000 1/10 HP, Std. 20' 80' 115 volts, 60 Hz 100 watt 30.0" x 30.2" x 48.0" 230/104
3030001† 1/3 HP, Std. 20' 80' 230 volts, 50 Hz 100 watt 30.0" x 30.2" x 52.0" 230/104
3030002 None — — 115 volts, 60 Hz 100 watt 30.0" x 30.2" x 48.0" 210/95
3030003† None — — 230 volts, 50 Hz 100 watt 30.0" x 30.2" x 48.0" 210/95
3030004 1/4 HP, EP 20' 80' 115 volts, 60 Hz None 30.0" x 30.2" x 54.0" 240/109
3030005† 1/3 HP, EP 20' 80' 230 volts, 50 Hz None 30.0" x 30.2" x 54.0" 240/109

EP = Explosion-proof **Maximum length of straight duct to achieve 100 fpm face velocity International electrical configuration

12
Accessories & Dimensional Data
Fiberglass 30 Laboratory Hoods
8.9"
8.9" 13.1"
13.1"
(22.7cm)
(22.7 cm)
Duplex Electrical Receptacle Kits 8.9"
(22.7 cm)
(33.1
(33.1 cm)
cm)
13.1"
(33.1 cm) 11.7"
8.2"
8.2" 11.7"
Each kit includes duplex electrical receptacle, wiring, junction box (20.9cm)
(20.9 cm)
8.2" (29.6
(29.6 cm)
11.7"cm) 3030000
(20.9 cm) (29.6 cm)
and receptacle cover plate. For mounting on the lower right side 6.7"
6.7"
(with Built-in Blower)
(17.0cm)
(17.0 cm)6.7"
IDID Motor
Motor
fixture panel. (17.0 Exhaust
Exhaust
cm) ID Motor
Collar
Collar
Exhaust
Collar
Catalog # Kit Shipping Wt. TOP
TOP
TOP
TOP
2834800 115 volts, 20 amps AC 4 lbs. (2 kg)
2834801 115 volts, 20 amps AC, GFCI 4 lbs. (2 kg)
48.0"
48.0"
(121.9
(121.9 cm)
48.0" cm) 11.6"
36.0" 11.6"
Standard Service Fixture Kits (121.9 cm) 36.0" (29.5
(29.5 cm)
cm)
11.6"
(91.4
(91.4 cm)
cm)
36.0" (29.5 cm)
Interior 2.5°
2.5°
Interior
(91.4 cm) 30.0"
30.0"
Each kit includes one remotely-controlled service fixture with 0.25" 28.0"
28.0"
(71.1
(71.1 cm)
20.0"(50.8
cm) 20.0" (50.8cm)
cm) Height
Height
Interior
Slope
Slope
2.5° (76.2
(76.2 cm)
30.0"cm)
28.0" SashOpening
Sash Opening 29.0"
29.0" Slope
diameter valve and tubing, color-coded fixture knob and color-coded cm) 20.0" (50.8 cm)
Viewing
Viewing
(71.1
Sash Opening
Height
(73.7
(73.7 cm)
29.0"cm)
22.7"
22.7"
(57.6
(57.6 cm)
cm)
(76.2 cm)
Height
Height
Viewing 25.0"(63.5
(63.5cm)
cm) 22.7"
hose connector. For mounting on the right side fixture panel. Shipping Height
25.0"
25.0"Inside
Inside
(63.5 cm)
(73.7 cm) Sash
Sash(57.6 Frame
Frame
cm)
totoBaffle
Sash Baffle
Frame
weight 4 lbs. (2 kg.) Inside
30.0"(76.2
30.0" (76.2cm)
cm) 30.2" to Baffle
30.2"(76.6
(76.6 cm)
cm)
30.0" (76.2 cm)
FRONT
FRONT
FRONT 30.2" (76.6 cm)
SIDE
SIDE
SIDE
FRONT SIDE
8.9"8.9" 13.2"
13.2"
Catalog # Kit Tubing Valve Knob/Connector Color (22.7
(22.7
8.9"
(22.7cm)cm)
cm) 13.2"
(33.5
(33.5
(33.5 cm)cm)
cm)
8.2"8.2"
8.2" 11.2" 3030001
(20.9 11.2"
S28139 Cold Water (CW) Copper Brass Green (20.9
(20.9 cm)cm)
cm) 11.2"
(28.5
(28.5
(28.5 cm)cm)
cm)
(with Built-in Blower)
6.7" 6.7"
S28136 Hot Water (HW) Copper Brass Red (17.0
(17.0
(17.0
6.7"
cm)cm)
cm) IDIDID Motor
Motor
Motor
Exhaust
Exhaust
Exhaust
S28138 Deionized/ Stainless Nickel-Plated/ White Collar
Collar
Collar
Distilled Water (DI) Steel Stainless Steel TOPTOP
TOP
TOP
S28140 Vacuum (VAC) Copper Brass Yellow Motor
Motor
Motor
S28142 Air (AIR) Copper Brass Orange
S28141 Gas (GAS) Brass Brass Blue 52.0"
52.0"
52.0"
(132.1
(132.1 cm)cm)
cm)
S28135 Nitrogen (NIT) Copper Brass Brown (132.1
36.0"
36.0" 11.6"11.6"
11.6"
36.0" (29.5(29.5
(29.5 cm)cm)
cm)
(91.4
(91.4
(91.4 cm)cm)
cm)
S28137 Argon (ARG) Copper Brass Gray 28.0" 48.0"
Interior
Interior
Interior
2.5°
2.5°2.5°
Slope 30.0"
30.0"
30.0"
28.0" 20.0" (50.8 48.0" Slope
28.0"
(71.1 20.0"
20.0" (50.8
(50.8 cm)cm)
cm) 48.0"
(121.9 cm) Height
Height
Height Slope (76.2
(76.2
(76.2 cm)cm)
cm)
S28134 Steam (STM) Copper Brass Black (71.1
(71.1 cm)cm) Sash
cm) Sash
Sash Opening
Opening
Opening
(121.9
(121.9cm)
cm) 29.0"
29.0"
29.0" 22.7"22.7"
Viewing
Viewing
Viewing 25.0" 22.7"
25.0" (57.6
Height
Height 25.0"
(63.5 (57.6
(57.6 cm)cm)
cm)
Height (63.5
(63.5 cm)cm)
cm)
Inside Sash
SashSash Frame
Frame
Frame
Inside
Inside toBaffle
Baffle
totoBaffle
30.0" (76.2cm)cm)
30.0"
30.0" (76.2
(76.2 cm) 30.2" (76.6 cm)cm)
30.2"
30.2" (76.6(76.6cm)
FRONT
FRONT SIDESIDE
FRONT
FRONT SIDE
SIDE
Guardian Digital Airflow Monitor Kits
™ 8.9"8.9"
(22.7(22.7
cm) cm)
8.9"
An LCD displays average face velocity. Audible/visual alarm alerts user (22.7 cm)
8.2"8.2"
(20.9(20.9
cm) cm)
8.2" 3030002 and 3030003
to low or high face velocity. For installation in a factory-prepared cutout on (20.9 cm)
(for use with Remote Blower)
upper portion of right side fixture panel. Shipping weight 6 lbs. (3 kg) 6.7"6.7"
(17.0(17.0
cm) cm)
6.7"
ID(17.0
Exhaust
ID cm)
Exhaust
CollarCollar
ID Exhaust
Collar
Catalog # Description
TOP TOP
TOP
9743201 Guardian Digital Airflow Monitor for 115 volt, 60 Hz operation TOP

9743205* Guardian Digital Airflow Monitor for 230 volt, 50 Hz operation


36.0"36.0"
(91.4(91.4
cm) cm)
36.0" 11.6"11.6"
Interior
(91.4 cm)
Interior (29.5
11.6" cm) cm)
(29.5
Guardian™ 500 Airflow Monitor Field Installation Kits 48.00"
48.00"
Height
Interior
Height (29.5 cm)
2.5°2.5°
28.0"28.0" (121.9
48.00" cm) Height
(121.9 cm) 30.0"30.0"
Slope
Audible/visual alarm alerts user to low face velocity. For installation in cm) cm)20.0"20.0"
(71.1(71.1
28.0" (50.8(50.8
cm) cm) (121.9 cm)
29.0"29.0"
2.5°Slope
Slope
(76.2 cm) cm)
30.0"
(76.2
(76.2 cm)
(71.1 ViewingSash
Viewing
cm) Opening
20.0" (50.8
Sash cm)
Opening (73.7(73.7
cm) cm) 22.7"22.7"
a factory-prepared cutout on upper portion of right side fixture panel. Height
HeightSash Opening
Viewing 25.0"25.0" 29.0"
(73.7 cm) (57.6
22.7" cm) cm)
(57.6
Height (63.5
25.0"cm) cm) Sash Frame
Shipping weight 6 lbs. (3 kg) (63.5
(63.5
Inside
cm)
Inside
(57.6Sashcm)Frame
to Baffle
Sash Frame
to Baffle
Inside to Baffle
30.0"30.0"
(76.2(76.2
cm) cm) 30.2"30.2"
(76.6 cm) cm)
(76.6
30.0" FRONT
(76.2 cm)
FRONT
30.2" SIDE
(76.6 cm)
SIDE
FRONT SIDESIDE
FRONT
Catalog # Description
8.9"
8.9"8.9" 13.2"
13.2"
13.2"
9743213 Guardian 500 Airflow Monitor for 115 volt, 60 Hz operation (22.7
(22.7 cm)
(22.7
cm)cm) (33.5
(33.5 cm)
(33.5
cm)cm)
8.2"
8.2"8.2" 11.2"
11.2"
11.2"
3030004 and 3030005
9743214* Guardian 500 Airflow Monitor for 230 volt, 50/60 Hz operation (20.9
(20.9 cm)
(20.9
cm)cm) (28.5
(28.5 cm)
(28.5
cm)cm) (with Built-in
6.7"
6.7"6.7" Explosion-Proof Blower)
(17.0
(17.0 cm)
(17.0 ID
cm)cm)
ID ID Explosion-Proof
Explosion-Proof
Explosion-Proof
Exhaust
Exhaust
Exhaust Motor
Motor
Motor
Collar
Collar
Collar
4892900 Explosion-Proof Light Fixture Kit
For mounting on Fiberglass 30 Hood 3030004 or 3030005. Includes TOP
TOP TOP
TOP
Explosion-Proof
Explosion-Proof
Explosion-Proof
explosion-proof incandescent light fixture, mounting hardware and Motor
Motor
Motor
instructions. 13" h x 7" diameter. 150 Watt maximum. Suitable for Class I,
Group C & D and Class II, Group E & G room classifications per National
Fire Protection Association (NFPA) 70. Bulb and electrical wiring are
54.0" 11.6"
11.6"
11.6"
not included. Shipping weight 1 1 lbs. (5 kg) 54.0"
54.0"
(137.2 cm)
(137.2
(137.2 cm)cm) (29.5
(29.5 cm)
cm)cm)
(29.5
48.0" 2.5°
2.5°2.5°
48.0"
48.0" 36.0"
36.0"
36.0" Slope
28.0" (121.9 cm)
(121.9
(121.9 cm)cm) Slope
Slope 30.0"
30.0"
30.0"
28.0"
28.0" 20.0"
20.0" (50.8
20.0"
(50.8 cm)
(50.8
cm)cm) (91.4
(91.4 cm)
(91.4
cm)cm) (76.2 cm)
(71.1 cm) (76.2 cm)cm)
(76.2
* International electrical configuration (71.1
(71.1
cm)cm)Sash Opening
SashSash
Opening
Opening Interior
Interior
Interior 22.7"
22.7"
22.7"
Viewing
Viewing
Viewing 25.0" Height (57.6 cm)
Height 25.0"
25.0" Height
Height (57.6
(57.6
cm)cm)
Height
Height (63.5
(63.5 cm)
(63.5
cm)cm) Sash Frame
SashSash
Frame
Frame
Inside
Inside
Inside to
to Baffle
Baffle
to Baffle
30.0"
30.0" (76.2
30.0"
(76.2 cm)
(76.2
cm)cm) 30.2"
30.2" (76.6
30.2"
(76.6 cm)
(76.6
cm)cm) 13
FRONT
FRONT
FRONT SIDE
SIDESIDE
SIDE
FRONT
3' Protector XVS Ventilation Station 4863010 is shown with
FilterMate Portable Exhauster S28149, Solid Epoxy Dished Work Surface S28146 and
Telescoping Base Stand with Casters 3746711.

Inset: 3' Protector XVS Ventilation Station 4863030 is shown with


Requires
Solid Epoxy Dished Work Surface S28146 and Ductwork and
Blower
Telescoping Base Stand 3746701.
Protector XVS Ventilation Stations
® ™

Features & Benefits

Protector XVS Ventilation Stations provide an economical alterna- than traditional hoods. They have no switches, wiring or service
tive to traditional fume hoods. With their low profile and clear fixtures that add incremental costs.
sides, top and sash, Protector XVS Ventilation Stations are well Protector XVS Stations may be connected to a remote blower
suited for classroom and educational laboratory environments and exhausted to the outside. Alternatively, they may be connected
where supervision or demonstrations are required. They may also to the FilterMate Portable Exhauster(s), which uses a carbon filter(s),
be used as weighing stations, light duty fume hoods, solvent clean- a HEPA filter(s) or HEPA/carbon filter combination to remove
ing work bays, and veterinary pathology and cytology enclosures. fumes and vapors and/or hazardous particulates from the exhaust
With smaller working heights and available in widths from 2', XVS air without ducting.
Stations exhaust less tempered room air and conserve more energy

Tempered safety glass front Sturdy glacier white and gray Upper dilution air supply Patented* rear baffle with
sash, sides and top offer powder-coated aluminum introduces room air at the top of zones of perforations promotes
excellent visibility, ambient light frame and steel rear plenum the sash to dilute contaminants horizontal laminar airflow to
and protection. Glass provides and baffle dissipate static in the upper chamber and maximize containment. The
better fire, scratch and chemical charge and provide durability bathes the back of the sash baffle pivots down and is easily
resistance than acrylic and dis- and better chemical resistance with clean air. removable for cleaning.
sipates static charge. compared to acrylic models.
No plastic-to-plastic bonding
is used. Ergonomic angled sash allows
a closer view, reduces glare and
provides a more comfortable
operating position than vertical
sashes.

Patented* upper containment


sash foil bleeds air into the
enclosure to direct concentra-
tions of contaminants away from
the operator’s breathing zone.

Deep interior easily accom-


modates a variety of apparatus
including large balances. Models
are available with a 23.4" interior
depth. Some 5', 6' and 8' models
have 30.0" interior depths.

8", 10" or 12" high sash


opening limits exhaust demand,
conserves costly tempered
room air and requires a smaller
remote blower than most fume
hoods.
Side-entry air foils allow air to Patented* Clean-Sweep™ air Two utility ports allow pas-
sweep across the interior glass foil allows air to sweep the sage of tubing, electrical cords
surfaces to enhance containment. work surface for maximum and interface cables from inside
Flexible exhaust options.
containment. Airflow openings to back exterior for connection
Rectangular exhaust openings
pull inflow air from under the to services.
on the top and bottom allow
air foil so that clean air contin-
the Protector XVS Ventilation
ually flows through the air foil
Modified ASHRAE 110-1995 Station to be connected to
creating a constant barrier of
conformity independently ductwork for exhausting to the
protection from contaminants.
verified by ECT, Inc. outside or to FilterMate™ Portable
Exhauster(s) for filtered removal
of fumes, particulates or pow-
Low profile design requires ders. Using the bottom exhaust
Particulate containment
less space than most ventilated opening keeps ductwork hidden,
independently verified by
Left-side mounted waste enclosures. maximizing room visibility.
SafeBridge Consultants, Inc.**
chute, standard on some 5', 6'
and 8' models, isolates contami-
nated waste in a sealable bag. Exclusive Feature * U.S. Patent No. 6,461,233 **Contact Labconco for more information.

15
Protector XVS Ventilation Stations
® ™

At far left: 8' Protector XVS Ventilation Station 4868060 is


shown with Solid Epoxy Dished Work Surface 3908411 and
Protector Standard Storage Cabinets 9904300 and 9904000.
Blower, ductwork, work surface and supporting base must
be ordered separately. At left: 2' Protector XVS Ventilation
Station 4862030 is shown with Solid Epoxy Dished Work
Surface 3908400 and Telescoping Base Stand 3747000. Blower,
ductwork, work surface and supporting base must be ordered
separately.

Requires
Ductwork and
Blower

All models feature: All models conform to the • Supporting base.


• By-pass airflow design. following regulations and • Ductwork. See pages 26-27 and back
standards: cover.
Deep interior of 23.4" or 30.0" depend-
ing on the model. • SEFA 1-2010 Optional accessories (see pages
Clean-Sweep* air foil. • Modified ASHRAE 110-1995 26-27 and back cover:
Upper dilution air supply. • ANSI Z9.5-2011 • Guardian Airflow Monitors. See back
Upper containment sash foil. • SEFA 8-2010, Cabinet Surface Finish Tests cover.
Zone-perforated, pivoting rear baffle.* 5', 6' and 8' models with 35.5" • Fluorescent Task Lights.
• Side-entry air foils. exterior depth include: • Utility Shelves, Bottle Holder and
• Glacier white and gray powder-coated Tissue Holder.
• Left-side mounted waste chute. Bags
aluminum frame and steel rear plenum not included. Minimum bag size • Exhaust Transition Adapters.
and baffle. No plastic-to-plastic bonding required: 10" x 16". • Waste Chute Stopper.
is used. • Waste Chute Bags. Contact your
Required accessories not included: laboratory supply dealer.
• Clear 3/16" thick top and sides and
1/4" thick sash. • Remote blower or FilterMate
• Ergonomic 20° angled and hinged, Portable Exhauster(s). See pages Contact Labconco at 800-821-5525 or
20-22 and 27. 816-333-8811 for blower sizing assistance
pivoting sash with wiping seal. Sashes
and ordering information on accessories not
on 5', 6' and 8' models incorporate an • Work surface. See page 25.
included in this brochure.
external gas-assist lift.

• Models with 8.0" sash opening height


Nominal Sash Total Exhaust CFM and Static Pressure (w.g.)
have 16.5" locking height and 19.0"
Width Height Opening Ht. 100 fpm S.P. 80 fpm S.P. 60 fpm S.P.
maximum loading height. Models with
10.0" or 12.0" sash opening height have 2 Feet Std. 8" 120 0.05" 95 0.03" 70 0.02"
25.75" locking height and 28.25" maxi- 2 Feet Tall 10" 150 0.08" 120 0.05" 90 0.03"
mum loading height.
3 Feet Std. 8" 185 0.10" 145 0.06" 110 0.04"
• Two utility ports with iris openings and 3 Feet Tall 10" 230 0.15" 185 0.10" 140 0.06"
plastic plugs.
4 Feet Std. 8" 250 0.16" 200 0.10" 150 0.06"
• 2" x 10" rectangular exhaust openings
4 Feet Tall 10" 310 0.24" 250 0.16" 185 0.09"
at the top and bottom. 5', 6' and 8'
5 Feet Std. 8" 315 0.23" 250 0.15"** 190 0.08"
models include three openings on the
top and bottom. Cover(s) provided for 5 Feet Tall 12" 480 0.54" 385 0.35"** 290 0.20"
unused openings. 6 Feet Std. 8" 380 0.32" 305 0.21"** 230 0.12"
• Particulate containment independently 6 Feet Tall 12" 580 0.75" 465 0.48"** 350 0.27"
verified by SafeBridge Consultants, Inc.†† 8 Feet Std. 8" 510 0.18" 410 0.12" 310 0.07"

• Modified ASHRAE 110-1995 conformity 8 Feet Tall 12" 775 0.42" 620 0.27" 465 0.15"

as low as 50 fpm independently verified * * Static pressure when one center exhaust opening is used.
by ECT, Inc.†† †
Static pressure when two outer exhaust openings are used. Requires “T” Connector 3981600, not included. Contact Labconco.
††
Contact Labconco for more information.

Exclusive Feature * U.S. Patent No. 6,461,233


16
Ordering Information & Dimensional Data
Protector® XVS™ Ventilation Stations

Protector XVS Ventilation Stations


® ™

Nominal Catalog Overall Overall (A) (B) (C) (D) (F) (G) (I) (J) (K) Ship. Wt.
Width Number Height (E) Depth (H) in./cm in./cm in./cm in./cm in./cm in./cm in./cm in./cm in./cm lbs./kg
in./cm in./cm
2 Feet 4862010 22.8/57.9 29.0/73.7 24.0/61.0 12.0/30.5 21.6/54.9 28.6/72.6 22.3/56.6 19.0/48.3 23.4/59.4 8.0/20.3 — 105/48
2 Feet 4862030 32.0/81.3 29.0/73.7 24.0/61.0 12.0/30.5 21.6/54.9 37.8/96.0 31.5/80.0 27.7/70.4 23.4/59.4 10.0/25.4 — 135/61
3 Feet 4863010 22.8/57.9 29.0/73.7 36.0/91.4 18.0/45.7 33.6/85.3 28.6/72.6 22.3/56.6 19.0/48.3 23.4/59.4 8.0/20.3 — 135/61
A A
3 Feet 4863030
Enclosure Width Enclosure Width
32.0/81.3 29.0/73.7 36.0/91.4 18.0/45.7 33.6/85.3 37.8/96.0 31.5/80.0 27.7/70.4 23.4/59.4 10.0/25.4 — 160/73
3.2" (8.1 cm) for B 3.2" (8.1 cm) for B
4 Feet
3912401 4864010 22.8/57.9 29.0/73.7 48.0/121.9 24.0/61.0 45.6/115.8 28.6/72.6
3912401 22.3/56.6 19.0/48.3 23.4/59.4 8.0/20.3 — 160/73
4 Feet 4864030 32.0/81.3 29.0/73.7 48.0/121.9 24.0/61.0 45.6/115.8 37.8/96.0 31.5/80.0 27.7/70.4 23.4/59.4 10.0/25.4 — 185/84
5 Feet 4865010 22.8/57.9 29.0/73.7 60.0/152.4 30.0/76.2 57.6/146.3 28.6/72.6 22.3/56.6 19.0/48.3 23.4/59.4 8.0/20.3 10.0/25.4 290/132
5 Feet 4865030 32.0/81.3 29.0/73.7 60.0/152.4 30.0/76.2 57.6/146.3 37.8/96.0 31.5/80.0 27.7/70.4 23.4/59.4 12.0/30.5 10.0/25.4 340/154
5 Feet* 4865060
Accessory Accessory Exhaust Transition
32.0/81.3 35.5/90.2 60.0/152.4 30.0/76.2 57.6/146.3 37.8/96.0
Exhaust Transition 31.5/80.0 27.7/70.4 30.0/76.2 12.0/30.5 10.0/25.4 380/172
6 Feet Adapter4866010
3912401 Centerline Adapter 3912401 Centerline
22.8/57.9 29.0/73.7 72.0/182.9 36.0/91.4 69.6/176.8 28.6/72.6 22.3/56.6 19.0/48.3 23.4/59.4 8.0/20.3 10.0/25.4 340/154
6 Feet 4866030 32.0/81.3 29.0/73.7 72.0/182.9 36.0/91.4 69.6/176.8 37.8/96.0 31.5/80.0 27.7/70.4 23.4/59.4 12.0/30.5 10.0/25.4 395/179
6 Feet* 4866060 32.0/81.3 35.5/90.2 72.0/182.9 36.0/91.4 69.6/176.8 37.8/96.0 31.5/80.0 27.7/70.4 30.0/76.2 12.0/30.5 10.0/25.4 440/220
8 Feet 4868010 22.8/57.9 29.0/73.7 96.0/243.8 48.0/121.9 93.6/237.7 28.6/72.6 22.3/56.6 19.0/48.3 23.4/59.4 8.0/20.3 24.0/61.0 455/206
8 Feet 4868030 32.0/81.3 29.0/73.7 96.0/243.8 48.0/121.9 93.6/237.7 37.8/96.0 31.5/80.0 27.7/70.4 23.4/59.4 12.0/30.5 24.0/61.0 520/236
C C
8 Feet* 4868060
Sash Opening32.0/81.3 35.5/90.2 96.0/243.8 48.0/121.9 93.6/237.7
Sash Opening 37.8/96.0 31.5/80.0 27.7/70.4 30.0/76.2 12.0/30.5 24.0/61.0 580/263
TOP
* Includes waste chute VIEW TOP VIEW

Accessory Exhaust Transition Adapter Accessory Exhaust Transition Adapter


3912400 (4.88"/12.4 cm OD, Hose) or 3912400 (4.88"/12.4 cm OD, Hose) A or
3912401 (6.03"/15.3 cm ID, Duct) 3912401 (6.03"/15.3 cm ID, Enclosure
Duct) Width
3.2" (8.1 cm) for
B B
3912401 2.3" (5.8 cm) for 3912401 B 2.3" (5.8 cm) for 3912401

6.4" (16.3 cm) 6.4" (16.3 cm)


Optional Optional D D
Airflow Gas-Assist Lift Airflow HeightGas-Assist Lift Height
Monitor (on 5', 6' Accessory
and 8' Exhaust Transition Monitor including
(on 5', 6' and 8' F including
F
Adapter 3912401 Centerline
models only) Interior Optional models only) Interior Optional
Airflow Height Airflow
G Height Monitor G Monitor
Loading 3.2"
E (8.1 cm) Exhaust Centerline Loading E
Height Enclosure
for 6.03" (15.3 cm) ID Duct Height Enclosure
J Height J B Height
K Sash Opening K
Sash Opening

Accessory Exhaust C IAccessory Exhaust I 5' and 6' enclosu


Transition Adapter Sash Opening
Interior Depth Adapter Waste
Transition 9.1" (23.1 cm) Interior Depth 9.1" (23.1 cm) include five cover
Chute
3912402 (4.88"/12.4 cm OD, Hose) or TOP VIEW 3912402 (4.88"/12.4 (35.5"
cm OD,deepHose) or on top and three
3912403 (6.03"/15.3 cm ID, Duct) H3912403 (6.03"/15.3 models
cm ID, Duct) H bottom. 8'enclosu
2.3"only)
(5.8 cm) 2.3" (5.8 cm)
Overall Depth for 3912403 Overall Depth for 3912403 include four cover
FRONT
FRONT VIEW Accessory
FRONTExhaustVIEW
Transition
TOP
SIDE VIEW
Adapter
SIDE VIEW
on top and three
(2', 3', 4' MODELS) 3912400 (4.88"/12.4 cm OD, Hose) or on the bottom.
(2',(6.03"/15.3
3912401 3', 4'cm MODELS)
ID, Duct)
10.4" SIDE (ALL MODELS)
(26.4 cm)
B 2.3" (5.8 cm) for 3912401
C
3.2" (8.1 cm) Exhaust Centerline Sash Opening
6.4" (16.3 cm)
for 6.03" (15.3 cm) ID Duct
B Optional
K K D
Airflow Gas-Assist Lift Height
Monitor (on 5', 6' and 8' F including
5' and 6' enclosures
5.2" (13.2 cm) dia. models only) Interior Optional
include five covers, two Airflow
Waste Chute Waste Chute G Height Monitor
on top and three on the (35.5" Depth Loading E
(35.5" deep
bottom. 8'enclosures Models Only) 1.3" (3.3 cm) Height Enclosure
models only) J Height
include four covers, one
on top and three Sash Opening
on the bottom.
10.4" 7.0" (17.8 cm) I
Accessory Exhaust
(26.4 cm) 9.1" (23.1 cm)
Transition Adapter A Interior Depth
C 3912402 (4.88"/12.4 cm OD, Hose) or Enclosure Width
Sash Opening 3912403 (6.03"/15.3 cm ID, Duct) H 2.3" (5.8 cm)
Overall Depth for 3912403
TOP FRONT VIEW FRONTSIDE VIEW
(5', 6', 8' MODELS) (5', 6', 8' MODELS)
5.2" (13.2 cm) dia.
Waste Chute
Contact Labconco at 800-821-5525 or 816-333-8811 or visit www.labconco.com for detailed AutoCAD drawings.
(35.5" Depth
Models Only) 1.3" (3.3 cm)

17
7.0" (17.8 cm)
A
Protector Demonstration Hoods
®

• Tempered safety glass front sash, sides, System Models S28479,


rear baffle and top that offer excellent S79524B, 3945020 & 3545021
360° visibility, ambient light and protec- also include:
tion. Glass provides better fire, scratch • Cart of glacier white powder-coated
and corrosion resistance than acrylic. tubular steel with black 1" thick solid
• 8" high sash opening that limits exhaust epoxy dished work surface, handle bar,
demand, conserves costly tempered room bottom shelf and 4" diameter toe-locking
air and requires a smaller remote blower casters.
than most fume hoods. Tall models, 32.0" • FilterMate Portable Exhauster designed
high, have a 10" high sash opening. for use with two Carbon Filters or one
• Ergonomic angled sash allows a closer Carbon Filter and one HEPA Filter
view, reduces glare and provides a more (Filters are not included. See page 22
comfortable operating position than ver- for ordering information.) Includes 8
tical sashes. Models, 22.8" high, have a feet of 5" ID flexible gray polypropylene
20° angle; models, 32.0" high, have a hose, two clamps, a 4.9" OD Lower
14° angle. The hinged sash pivots Transition Adapter for connection to the
upward and locks to a loading height of bottom of the Protector Demonstration
Protector Demonstration Hood
19.0" or 27.7" depending on the model. Hood, and an IEC 3-wire electrical cord
System S79524B. • Lower exhaust tissue screen. with plug.

Protector Demonstration Hoods are low • Two utility ports with iris openings that Models S28143 & S28144
profile, light-duty fume hoods designed to allow passage of tubing, electrical cords require:
provide 360° of close observation of proce- and interface cables from inside to back • Connection to a remote blower,
dures during educational demonstrations. exterior for connection to services. house exhaust or FilterMate
• Flexible exhaust options. 2" x 10" rectan- Portable Exhauster. See pages 20-21
All models feature: gular exhaust collars on the top and for FilterMate. See pages 26-27 and
• Deep 23" interior that easily accommo- bottom allow the Protector Demonstration back cover for Remote Blowers and
dates a variety of apparatus. Hood to be connected to ductwork for ductwork.

• Patented* Clean-Sweep™ air foil that exhausting to the outside or to a Filter- • Work surface and supporting base.
allows air to sweep the work surface for Mate Portable Exhauster for filtered See page 25 for Cart. See page 25 for
maximum containment. Airflow open- removal of fumes and/or particulates. work surface.
ings pull inflow air from under the air Using the bottom exhaust collar keeps Accessories include (see pages
foil so that clean air continually flows ductwork hidden, maximizing room 25-27 and back cover):
through the air foil creating a constant visibility.
• Fluorescent Task Lights.
barrier of protection from contaminants. All models conform to • Exhaust Transition Adapters.
• Upper containment sash foil that bleeds the following regulations
• Exhaust Dampers.
air into the enclosure to direct concen- and standards:
trations of contaminants away from the • Guardian Airflow Monitors.
• SEFA 1-2010
operator’s breathing zone. • Modified ASHRAE 110-1995 • Cart.
• Upper dilution air supply that introduces • ANSI Z9.5-2011 • Remote Blowers.
room air at the top of the sash to dilute • UL 61010-1 (115 volt models)
concentrations in the upper chamber • CAN/CSA C22.2 No. 61010.1
and bathes the back of the sash with Contact Labconco at 800-821-5525 or
(115 volt models)
clean air. 816-333-8811 for blower sizing assistance
• CE Conformity Marking and ordering information on accessories not
• Clear rear baffle that directs air streams (230 volt models)
included in this brochure.
to the back of the interior for removal • SEFA 8-2010, Cabinet Surface Finish Tests
through the exhaust connection. The
baffle may be pivoted downward for Nominal Overall Sash Opening Total Exhaust CFM and Static Pressure
cleaning. Width Height Height 100 fpm S.P. 80 fpm S.P. 60 fpm S.P.
• Side-entry air foils that allow air to 3 Feet 22.8" 8" 185 0.10" 145 0.06" 110 0.04"
sweep across the interior glass surfaces
3 Feet 32.0" 10" 230** 0.15" 185 0.10" 140 0.06"
to enhance containment.
• Sturdy glacier white and gray powder- Exclusive Feature * U.S. Patent No. 6,461,233
coated aluminum frame. ** FilterMate Portable Exhauster with two filters provides up to 220 CFM and with single filter provides up to 270 CFM.

18
Ordering Information & Dimensional Data
Protector® Demonstration Hoods

Nominal Catalog Electrical Enclosure Shipping


Width Number Requirements Height Weight lbs./kg
rotector Demonstration Hoods
P
3 Feet S28143 not applicable 22.8" 75/34
3 Feet S28144 not applicable 32.0" 85/39

Protector Demonstration Hood Systems – include Cart with Work Surface, Lower Transition Adapter and FilterMate Portable Exhauster for
use with two Carbon Filters or one Carbon Filter and one HEPA Filter in any combination.*
3944300, 3945000
& 3945020
3944301, 3945001
& 3945021
20. 0" 3945000
3944300, 29. 3" 3945001
3944301,
A
3 Feet S28479 115 volts, 60 Hz, 10 amps LOADI NG HEIGHT
& 3945020
22.3"
20.0"
LOADING
& 3945021
31.
29.6"3"
HEIGHT
22.8" 125/57
B
A INTERIOR
LOADING HEIGHT
HEIGHT INTERIOR
LOADING HEIGHT
HEIGHT
3 Feet S79524B 115 volts, 60 Hz, 10 amps BC 22.3"
22.8"
ENCLOSUREHEIGHT
INTERIOR HEIGHT
32.0"6"
31.
ENCLOSURE
INTERIOR
32.0"
HEIGHT
HEIGHT
135/61
3 Feet 3945020** 28.8"
230 volts, 50/60 Hz, 5 amps DC 22. 6"
HEIGHT W/ HEIGHT
ENCLOSURE MONITOR
37.9"
32.0"
22.8"
HEIGHT W/ HEIGHT
ENCLOSURE MONITOR 125/57
8.0"
28.6" 10.
37.9"0"
E
D
3 Feet 3945021** 230 volts, 50/60 Hz, 5 amps SASH OPENING
HEIGHT
58.
8.0" 8"
W/ MONITOR SASH
HEIGHT OPENI
10.
68.0"0"
32.0"
NG
W/ MONITOR
135/61
E
F SASH OPENING
HEIGHT W/ CART SASH OPENI
HEIGHT NG
W /CART
58.6"
64. 8" 73. 9"
68.0"
F
* Filters are required but not included. See page 22 for ordering information. ** International electrical configurationG HEIGHT W/ CART &
MONITOR
HEIGHT
HEIGHT
MONITOR
W/WCART
/CART
&
64.6" 73.9"
G HEIGHT W/ CART & HEIGHT W/ CART &
MONITOR MONITOR

36.0" (91.4 cm) 36.0" (91.4 cm)


18.0"36.0" (91.4 cm) OPTIONAL 18.0" OPTIONAL
AIRFLOW (45.736.0" (91.4 cm) AIRFLOW
(45.7
18.0"cm) OPTIONAL 18.0"cm) OPTIONAL
(45.73.2"
cm)(8.1 cm) MONITOR
AIRFLOW 3.2"
(45.7 cm)(8.1 cm) MONITOR
AIRFLOW
3.2" (8.1 cm) MONITOR 3.2" (8.1 cm) MONITOR

OPTIONAL LOWER
TRANSITION CART
OPTIONAL 29.1" TRANSITION
LOWER HANDLE
ADAPTER
TRANSITION ADAPTER CART
(73.9
29.1"cm) TRANSITION HANDLE
ADAPTER (73.9 cm) ADAPTER

33.6" (85.3 cm) 33.6" (85.3 cm)


SASH (85.3
33.6" OPENING
cm)
SASH (85.3
33.6" OPENING
cm)
SASH OPENING SASH TOP
OPENING
TOP
TOP TOP
(3945000,
(3944300TOP
&&3944301) TOP3945001, OPTIONAL
(S28143 S28144) (S28479,
3945020 S79524B,
(3945000,&3945001,
3945021) AIRFLOW
OPTIONAL
(3944300 & 3944301) OPTIONAL
2.3" (5.8 cm) TRANSITION 3945020
3945020 &&3945021)
3945021) MONITOR
AIRFLOW
OPTIONAL OPTIONAL OPTIONAL MONITOR
2.3" (5.8 cm) ADAPTER
TRANSITION
TRANSITION
OPTIONAL AIRFLOW
OPTIONAL 6.4" OPTIONAL
ADAPTER MONITOR ADAPTER AIRFLOW
TRANSITION AIRFLOW 6.4" OPTIONAL
ADAPTER MONITOR MONITOR
AIRFLOW
OPTIONAL MONITOR
AIRFLOW
OPTIONAL D
MONITOR
AIRFLOW B C B C
A D A
MONITOR B C B C
A A
E E
E E G
23.0" (58.4 cm) F
OPTIONAL 8.1" (20.6 cm) G
WORKING
23.0" (58.4 cm) FILTERMATE F
18.0" TRANSITION
OPTIONAL DEPTH 8.1" (20.6 cm)
(45.7 ADAPTER WORKING PORTABLE
18.0"cm) TRANSITION 29.1"DEPTH
(73.9 cm) 2.3" (5.8 cm) FILTERMATE
EXHAUSTER
(45.7 cm) ADAPTER OVERALL DEPTH
29.1" (73.9 cm) 2.3" (5.8 cm) PORTABLE
OVERALL DEPTH EXHAUSTER
FRONT
FRONT SIDE
(3944300
(3944300 & 3944301)
& 3944301)
FRONT
FRONT (3944300SIDE
& 3944301)
FRONT
(3944300
(3944300 & 3944301)
& 3944301) SIDE
(3944300 & 3944301)
(S28143 & S28144) (S28143 & S28144) 31.9" (81.0 cm)
3944300 3944300 39.0" (99.1 cm)
A
20.0"
3944300
LOADING HEIGHT
29.3"
LOADING 3944300
HEIGHT OVERALL WIDTH
39.0" (99.1 cm) OVERALL
31.9" DEPTH
(81.0 cm)
22.3"
20.0" 31.6"
29.3"
OVERALL WIDTH OVERALL DEPTH
BA
INTERIOR
LOADING HEIGHT
22.8"
22.3"
INTERIOR
LOADING HEIGHT
32.0"
31.6"
FRONT SIDE
BC ENCLOSUREHEIGHT
INTERIOR
28.6"
HEIGHT ENCLOSURE
INTERIOR HEIGHT
HEIGHT
(3945000, 3945001,
FRONT
FRONT (3945000,
SIDE3945001,
SIDE
3945020
(3945000,&3945001,
3945021)
22.8" 37.9"
32.0"
DC HEIGHT W/ HEIGHT
ENCLOSURE MONITOR HEIGHT W/ HEIGHT
ENCLOSURE MONITOR
3945020
(3945000,&3945001,
3945021)
DE
8.0"
28.6"
SASH OPENING
HEIGHT W/ MONITOR
10.0"
37.9"
SASH
HEIGHTOPENING
W/ MONITOR
(S28479, S79524B,
3945020 & 3945021) (S28479, S79524B,
3945020 & 3945021)
E
8.0"
SASH OPENING
10.0"
SASH OPENING 3945020 & 3945021) 3945020 & 3945021)

A B C D E F G

S28143, 19.0" (48.3 cm) 22.3" (56.4 cm) 22.8" (57.9 cm) 28.6" (72.6 cm) 8.0" (20.3 cm) 58.8" (149.4 cm) 64.6" (164.1 cm)
S28479 & loading interior enclosure height w/ sash height height
3945020 height height height monitor opening w/cart w/cart &
monitor
S28144, 27.7" (70.4 cm) 31.5" (80.0 cm) 32.0" (81.3 cm) 37.9" (96.3 cm) 10.0" (25.4 cm) 68.0" (172.7 cm) 73.9" (187.7 cm)
S79524B & loading interior enclosure height w/ sash height height
3945021 height height height monitor opening w/cart w/cart &
monitor

19
FilterMate Portable Exhausters

An accessory for the Protector • Included: 8 feet of 5" ID flexible gray


XVS Ventilation Station, Protector polypropylene hose, two clamps and
Demonstration Hood, Protector Work a 4.9" OD Upper Transition Adapter for
connection to the top of the Protector
Station and XPert ® Balance Enclosure,
XVS Ventilation Station or Protector
the FilterMate uses a HEPA filter, carbon Demonstration Hood. Models 3970004
filter or a combination of both filters to and 3970024 include a 4.9" OD Lower
remove hazardous powders, particulates Transition Adapter instead of the Upper
or vapors from the exhaust air stream and Transition Adapter.
return filtered air to the environment. • 6.5' IEC three-wire electrical cord with
plug (115 volt models).
All models feature:
• 9' IEC three-wire electrical cord.
FilterMate Portable Exhauster S28147. Includes HEPA filter. • Compact, corrosion-resistant housing An electrical plug is required
of glacier white and light gray powder- (230 volt models).
coated steel with rubber feet.
• Variable-speed, non-sparking motorized All models conform to
impeller. the following regulations
and standards:
• Quiet operation. Oversized HEPA filter,
efficient impeller and perforated exhaust • UL 61010-1
cover work together to provide lower • CAN/CSA C22.2 No. 61010.1
system exhaust velocity and noise
• CE Conformity Marking (230 volt models)
pressure levels.
Models S28147, 3970020,
Exhaust CFM Noise Pressure dB(A) S28150, 3970022, S28148 and
100 45-47 3970023 feature:
• HEPA filter, 99.99% efficient on
FilterMate Portable Exhauster S28149. Requires carbon fil- 150 51-54
ter (not included).
particulates 0.3 micron in size.
200 56-61
• True bag-in/bag-out filter disposal sys-
250 63-65 tem for safely removing and replacing
the filter without detaching the hose.
The HEPA filter may be easily accessed
• Inherently safe design. A negative pressure
by removing the exhaust cover for field
plenum surrounds the positive pressure
leak testing by a certified technician.
impeller so that if a leak occurs, the unfil-
tered air is captured and refiltered. Models S28150 and 3970022
• Sized for Protector Demonstration feature:
Hoods, Protector XVS Ventilation • 6.1" ID thimble connection from the
Stations, Protector Work Stations and FilterMate to an existing house exhaust
XPert Balance Enclosures. Capable of system for added safety.
efficiently filtering up to 250 CFM for
HEPA or carbon filtration; up to 200 Models S28149, 3970021,
FilterMate Portable Exhauster S28150. Includes HEPA filter and
thimble connection. Requires ducting to outside. CFM for combination HEPA/carbon S28148 and 3970023 require
filtration (60-100 fpm depending on one each and Models 3970004
enclosure model).
and 3970024 require two each
• Front-mounted rocker switch to control (not included):
power to the blower.
• Carbon Filter. Organic Vapor,
• Rear-mounted, auxiliary electrical Formaldehyde or Ammonia Filters are
outlet that may be connected to an offered. See page 22.
airflow monitor or other user-supplied
accessories. Optional Accessories:
• Only one FilterMate is required for all • Replacement HEPA Filter. See page 22.
2', 3' and 4' wide enclosures. Multiple • Replacement Bag-In/Bag-Out Bag.
FilterMates may be used for 5', 6' and 8' See page 22.
wide enclosures.
• Flexible Hose. See page 26.
• Thimble Connection. See page 26.
FilterMate Portable Exhauster S28148. Includes HEPA filter.
Requires carbon filter (not included). Exclusive Feature

20
Ordering Information & Dimensional Data
FilterMate™ Portable Exhausters

FilterMate™ Portable Exhausters


Catalog Filter Overall Electrical Airflow Exhaust Shipping
Number Usage Dimensions Requirements Potential Connection Weight lbs./kg
S28147 HEPA included 14.0" w x 23.0" d x 22.7" h 115 volts, 60 Hz 250 CFM (60-100 fpm) None. Room exhaust. 50/23
3970020* HEPA included 14.0" w x 23.0" d x 22.7" h 230 volts, 50 Hz 250 CFM (60 100 fpm) None. Room exhaust. 50/23
S28149 Carbon required† 14.0" w x 23.0" d x 22.7" h 115 volts, 60 Hz 250 CFM (60-100 fpm) None. Room exhaust. 48/22
3970021* Carbon required† 14.0" w x 23.0" d x 22.7" h 230 volts, 50 Hz 250 CFM (60-100 fpm) None. Room exhaust. 48/22
S28150 HEPA included 18.6" w x 23.0" d x 24.7" h 115 volts, 60 Hz 250 CFM (60-100 fpm) 6.06" ID Thimble to outside 54/25
3970022* HEPA included 18.6" w x 23.0" d x 24.7" h 230 volts, 50 Hz 250 CFM (60-100 fpm) 6.06" ID Thimble to outside 54/25
S28148 HEPA included†† 14.9" w x 23.0" d x 22.7" h 115 volts, 60 Hz 200 CFM (60-100 fpm)** None. Room Exhaust. 52/24
Carbon required†
3970023* HEPA included†† 14.9" w x 23.0" d x 22.7" h 230 volts, 50 Hz 200 CFM (60-100 fpm)** None. Room Exhaust. 52/24
Carbon required†

3970004 Two Carbon required† 14.9" w x 23.0" d x 22.7" h 115 volts, 60 Hz 200 CFM (60-100 fpm)** None. Room Exhaust. 52/24
3970024 Two Carbon required† 14.9" w x 23.0" d x 22.7" h 230 volts, 50 Hz 200 CFM (60-100 fpm)** None. Room Exhaust. 52/24
† ††
* International electrical configuration Carbon Filter is not included. HEPA filter may be removed and substituted with a second carbon filter. ** 60-80 fpm on 4’ enclosure.

Models S28147, S28149, Models S28150 & 3970021 Models S28148 & 3970023
3970020 & 3970021 12.0" (30.5 cm)
12.1" (30.7 cm) 12.0" (30.5 cm) 12.0" (30.5 cm)
5.4"
5.4" (13.7 cm)
5.4" 5.4"
12.1" (30.7 cm) (13.7 cm) (13.7 cm) 12.0" (30.5 cm) (13.7 cm)
14.2"
cm) 4.88" (12.4 cm)
(36.114.2" 15.2"
14.0" DIA. INLET
(36.1 cm) 4.88" (12.4 cm) (38.6
15.2"cm) 14.9"
(35.6 cm) 5.4" 18.6" 4.88" 5.4"
DIA. INLET (38.6 cm) (37.8 cm) (12.4 cm)
4.88" (12.4 cm) DIA. INLET (13.7 cm) (47.218.6"
cm) (13.7 cm)
DIA. INLET
(47.2 cm)
14.0" 14.9" 4.88"
(35.6 cm) (37.8 cm) (12.4 cm)
4.88" (12.4 cm) DIA. INLET
DIA. INLET
TOP
TOP VIEW
6.06" (15.4 cm) EXHAUST ID 5.0"
TOP
TOP VIEW
THIMBLE CONNECTION
6.06" TO OUTSIDE
(15.4 cm) EXHAUST ID 5.0"
THIMBLE CONNECTION TO TOP OUTSIDEVIEW
TOP VIEW TOP VIEW
2.5" (6.4 cm) TOP
SPEED 3.5" (8.9 cm)
2.5" (6.4 cm) TOP VIEW
CONTROL 3.5" (8.9 cm)
79" (200.7 cm) 4.5"
2.5" (6.4 cm) 12.0" (30.5 cm) 2.5" (6.4 cm) 115V-15A POWER CORD (11.4 cm)
4.5" 2.5" (6.4 cm)
SPEED (11.4 cm) SPEED
2.5" (6.4 cm) (115V
CONTROL MODEL) CONTROL
SPEED
5.4"22.7" 118" (299.7 cm) 250V-10A CONTROL
79" (200.7POWER
250V-10A cm) CORD 79" (200.7 cm) 22.7"
20.2" (13.7
(57.7cm)
cm) 115V-15A POWER CORD 20.2" 115V-15A
79" (200.7POWER
cm) CORD
W/OUT PLUG 12.0" (30.5 cm) (57.7 cm)
2.1" (30.7 cm) (51.3 cm) (115V MODEL)
(230V MODEL) (51.3 cm) (115V MODEL)
115V-15A POWER CORD
14.2" 24.7"
(36.1 cm) 4.88" (12.4 cm) 15.2"
22.7"
118" (299.7 cm) 250V-10A
(62.7
(115V
118" MODEL)
(299.7 cm)
DIA. INLET 250V-10A POWER CORD 24.7"cm)
5.4" 20.2" 250V-10A
118" POWER
(299.7 cm) CORD 22.7"
5.4" 20.2" (38.6cm)
(57.7 cm) 20.2" (62.7 cm)
18.6" W/OUT PLUG (13.7 cm) W/OUT
250V-10APLUG
POWER CORD (57.7 cm)
(13.7 cm)(51.3 cm) (51.3
20.2"cm) (51.3 cm)
(47.2 cm) (230V MODEL) (230V MODEL)
W/OUT PLUG
(51.3 cm) 8A POWER OUTLET
14.9" (115V or 230V 4.88"MODEL) (230V MODEL)
(37.8 cm) (12.4 cm)
23.0" (58.4 cm) 10A FUSE 23.0" (58.4 cm)
DIA. INLET
SIDE VIEW REAR VIEW 8A POWER OUTLET 8A POWER OUTLET R
SIDE VIEW
6.06" (15.4 cm) EXHAUST ID 5.0" (115V or 230V MODEL) (115V
8A or 230V
POWER MODEL)
OUTLET
23.0" (58.4
THIMBLE CONNECTION TO cm)
OUTSIDE 23.0" (58.4 cm)
10A FUSE 10A
(115VFUSE
23.0" (58.4 cm) or 230V MODEL)
REAR VIEW 23.0" (58.4 cm) 10A FUSE
SIDE
SIDE VIEW TOP VIEW SIDE
SIDE VIEW TOP VIEW REAR VIEW
SIDE
SIDE VIEW R
W REAR VIEW
SIDE VIEW
3.5" (8.9 cm)
4.5" 2.5" (6.4 cm)
2.5" (6.4 cm) SPEED (11.4 cm) SPEED
SPEED CONTROL
CONTROL CONTROL
79" (200.7 cm) 79" (200.7 cm)
79" (200.7 cm) 115V-15A POWER CORD
115V-15A POWER CORD 115V-15A POWER CORD
(115V MODEL) (115V MODEL)
(115V MODEL)
118" (299.7 cm) 250V-10A 24.7" 118" (299.7 cm)
22.7" 118" (299.7 cm) 22.7" 250V-10A POWER CORD
250V-10A POWER CORD (62.7 cm) 20.2" 250V-10A POWER CORD (57.7 cm)
(57.7 cm) 20.2" W/OUT PLUG (51.3 cm) W/OUT PLUG
W/OUT PLUG (230V MODEL)
(51.3 cm) (230V MODEL) (230V MODEL)

8A POWER OUTLET 8A POWER OUTLET 8A POWER OUTLET


(115V or 230V MODEL) (115V or 230V MODEL) (115V or 230V MODEL)
m) 23.0"
10A(58.4
FUSEcm) 10A FUSE
23.0" (58.4FUSE
10A cm)
W
REAR
REAR VIEW REAR
REAR VIEW SIDE VIEW REAR
REAR VIEW
SIDE VIEW
21
Carbon and HEPA Filters
FilterMate™ Portable Exhausters

Below is an Application Matrix that pro- and, if so, estimate filter life. To begin the • Organic Filters are suitable for vapors
vides examples of appropriate uses for process, please complete the Chemical from solvents including acetone, ethyl
carbon and/or HEPA filters expended Usage Assessment Form available on acetate, toluene and xylene.
in the FilterMate Portable Exhauster . our website at www.labconco.com or call • Formaldehyde Filters are suitable for
Whether or not any ductless enclosure is us at 800-821-5525 or 816-333-8811. vapors from formaldehyde, formalin
appropriate for your application requires Carbon and HEPA Filters are available and gluteraldehyde.
consideration of factors such as the in a variety of types and, in some cases, • Ammonia Filters are suitable for
time-weighted exposure limits of your may be used in carbon/HEPA filter com- ammonia and low molecular weight
materials. Using Labconco’s exclusive bination. An online Chemical Guide, amines.
chemical assessment program, our tech- available at www.labconco.com, allows
• HEPA Filters, 99.99% efficient, are suit-
nical specialists can help you determine if you to search individual chemicals to
able for removing particulates such as
a Labconco ductless enclosure is the right determine their suitability for use with a
powders and pollen. They should not
ventilation product for your application carbon-filtered enclosure.
be used to capture biohazardous
materials or volatile organic material.
Application Matrix
Filter Type FilterMate & Protector Work Station FilterMate
Configuration Organic Ammonia Formaldehyde Carbon & HEPA* HEPA
Asbestos handling •
Clean room/critical environment •
Combination dry and liquid chemicals •
Drug compounding/research • •
Endoscopy instrument cleaning •
Histology/cytology tissue staining, coverslipping •
Histology/pathology
• •
Hormone research • •
Non-biohazardous microbiological samples with trace chemicals** •
Particulates in conjunction with chemical agents •
Pathology/tissue grossing • •
Photo-engraving •
Plastics production •
Pollen handling • •
Soldering • •
Solvent cleaning •
Solvent welding/gluing •
Weighing chemical powders • •
* Carbon filter type varies based on application
**The FilterMate Portable Exhauster is not designed to accommodate changing and disposing of biohazardous filters and materials and, therefore, should not be used as part of a biosafety enclosure.

Carbon and HEPA Filters and Accessories


for use with FilterMate Portable Exhausters
A HEPA Filter and Bag-In/Bag-Out Bag are included with FilterMate Portable Exhausters
designed for use with HEPA filters. One or two Carbon Filters are required for operation
with FilterMate Portable Exhausters designed for use with carbon filters.

Catalog # Description Shipping Wt. lbs./kg

3923400 Organic Carbon Filter, Type AC. Contains 12 pounds of granular activated carbon media. 14/6
3923401 Formaldehyde Carbon Filter, Type ST-1. Contains a minimum of 14 pounds of impregnated carbon media. 17/8
3923402 Ammonia Carbon Filter, Type AC. Contains a minimum of 16 pounds of impregnated carbon media. 21/10
3707900 Replacement HEPA Filter, 99.99% efficient on particles 0.3 micron in size. 10/5
3776002 Replacement Bag-In/Bag-Out Bag to ensure containment of particulate matter during HEPA filter changing. 1/0.5
1968800 Orange Cinching Strap for Bag-In/Bag-out Bag. 1/0.5
*Labconco strongly recommends ordering and keeping an extra set of filters to have readily available when filters become saturated and require replacement.
Sign up for the Filter Reminder Email Service at www.labconco.com.

22
Canopy Hoods

Nominal Catalog Shipping


Width Number Weight lbs./kg

4 Feet 4799000 140/64

6 Feet 7099000 205/93

4' Canopy Hood 4799000


CFM at Static Pressure – Inches H2O
0.12" 0.19" 0.22" 0.36" 0.39" 0.73" 2.45"
325 450 488 650 675 975 1950

6' Canopy Hood 7099000


CFM at Static Pressure – Inches H2O
0.17" 0.24" 0.31" 0.45" 0.49" 0.89" 2.50"
425 550 638 825 850 1275 2550

Dimensional Data

8.0"
4' MODEL 48.0" (121.9 cm) (20.3 cm)
6' MODEL 72.0" (182.9 cm) 30.0" (76.2 cm)
4' MODEL 10.81"
(27.5 cm) ID
Requires 6' MODEL 12.81" 2.0" (5.1 cm)
Ductwork and (32.5 cm) ID
Blower

18.0" (45.7 cm)

Canopy Hood 4799000. Blower and ductwork must be ordered separately.

The Canopy Hood is specifically designed Features: SIDE


to vent non-toxic materials such as • Glacier white powder-coated steel
heat, steam and odors from large or construction.
4' MODEL 48.0" (121.9 cm)
6' MODEL 72.0" (182.9 cm)
bulky apparatus such as ovens, steam • Integral baffle.
4'
baths and autoclaves. The hood may be • Fully assembled. 6'
installed on a wall or suspended from the • Include mounting hardware for installa-
ceiling for peninsular and corner locations. tion on wall or suspended from ceiling.
For most efficient performance, the Threaded rod is required for
suspension from ceiling.
hood should be installed no more
than 12" above the equipment to be Required accessories
ventilated. Coupled with a blower and not included: FRONT
ductwork, the Canopy Hood can operate at • Remote Blower.
a wide range of exhaust rates. • Ductwork. Contact Labconco at 800-821-5525 or
816-333-8811 for blower sizing assistance
and ordering information on accessories not
included in this brochure.

23
Flat Work Surfaces & Accessories

Flat Solid Epoxy Work Surfaces Catalog # Description Shipping Wt.


For Use with Labconco lbs./kg
Enclosures including S28130 30" w x 30" d x 1.25" thick, no cutouts 86/39
Fiberglass 30 and S28131 36" w x 30" d x 1.25" thick, no cutouts 90/41
Basic Laboratory Hoods* S28132 48" w x 30" d x 1.25" thick, no cutouts 110/50
S28133 72" w x 30" d x 1.25" thick, no cutouts 205/93

Spillstopper ™ &
Flat Work Surface D
Accessories
A
B
E
C

(A) 4005100 Cold Water Faucet with Rigid Gooseneck Factory-drilled 1361100 Sepia Bronze-Coated Cold and Hot Water Mixing Faucet
mounting hole in work surface is required. Shipping weight 4 lbs. (1.8 kg) with Swivel Gooseneck Not shown. Factory-drilled mounting hole in
(A) 4005900 Cold Water Faucet with Rigid Gooseneck and Vacuum work surface is required. Shipping weight 4 lbs. (1.8 kg)
Breaker Factory-drilled mounting hole in work surface is required. 1361200 Chrome-Plated Cold and Hot Water Mixing Faucet with
Shipping weight 4 lbs. (1.8 kg) Swivel Gooseneck Not shown. Factory-drilled mounting hole in work
(B) 4005200 Oval Polypropylene Cupsink Mounts in work surface with surface is required. Shipping weight 4 lbs. (1.8 kg)
cupsink cutout. 3" x 6". 1.5" NPSM** thread. Shipping weight 4 lbs. (1.8 kg) (D) 4005000 Service Fixture Specify air, gas or vacuum. Factory-drilled
4005201 Cupsink Cover Black solid epoxy resin cover for oval cupsink mounting hole in work surface is required. Shipping weight 4 lbs. (1.8 kg)
cutout. Provides a continuous work surface when a cupsink is not in use. (E) 4005800 Electrical Receptacle Pedestal-type, 115 volt, 15 amp
7.4" wide x 4.4" deep x 0.3" thick (19 x 12 x 0.8 cm). Shipping weight 2 lbs. duplex. Factory-drilled mounting hole in work surface is required.
(0.9 kg) Shipping weight 4 lbs. (1.8 kg)
(C) 1432600 Trap, PVC 1.5” diameter drum with coupling nut. For use with
cupsink. Shipping weight 10 lbs. (4.5 kg)

* Basic Hoods are not as wide or as deep as the work surfaces that support them.
** National Pipe Straight Mechanical

24
Accessories
Protector XVS Ventilation Stations & Protector® Demonstration Hoods
®

Solid Epoxy Work Surfaces


Black work surfaces are contoured to fit the dimensions of Protector XVS Ventilation Stations and Protector
Demonstration Hoods and dished to contain spills. One inch thick molded solid epoxy is chemical resistant and fire
proof.

Catalog # Dimensions For use with: Shipping Wt. lbs./kg

3908400 24.0" w x 26.7" d 2' Protector XVS 48/22


S28146 36.0" w x 26.7" d 3' Protector XVS, Protector Demonstration Hoods 72/33
3908402 48.0" w x 26.7" d 4' Protector XVS 96/44
3908406 60.0" w x 26.7" d 5' Protector XVS - 29.0" deep models 120/54
3908407 72.0" w x 26.7" d 6' Protector XVS - 29.0" deep models 144/65
3908408 96.0" w x 26.7" d 8' Protector XVS - 29.0" deep models 192/88
3908409 60.0" w x 35.5" d 5' Protector XVS - 35.5" deep models 160/72
3908410 72.0" w x 35.5" d 6' Protector XVS - 35.5" deep models 192/88
3908411 96.0" w x 35.5" d 8' Protector XVS - 35.5" deep models 255/115

Stainless Steel Work Surfaces


Type 304 stainless steel work surfaces are 0.8" thick, have a one inch deep front spill trough and fit dimensions of the
Protector XVS Ventilation Stations. Available in 5', 6' and 8' widths.

Catalog # Dimensions For use with: Shipping Wt. lbs./kg

3975500 60.0" w x 26.7" d 5' Protector XVS - 29.0" deep models 140/64
3975501 60.0" w x 35.5" d 5' Protector XVS - 35.5" deep models 180/82
3975600 72.0" w x 26.7" d 6' Protector XVS - 29.0" deep models 170/77
3975601 72.0" w x 35.5" d 6' Protector XVS - 35.5" deep models 220/100
3975800 96.0" w x 26.7" d 8' Protector XVS - 29.0" deep models 240/109
3975801 96.0" w x 35.5" d 8' Protector XVS - 35.5" deep models 290/132

S28145 Cart for Protector Demonstration Hoods


Provides mobile support for Protector Demonstration Hoods and 3' Protector XVS Ventilation Stations. Glacier white
powder-coated tubular steel with black 1" thick solid epoxy dished work surface, handle bar, bottom shelf and 4" diam-
eter toe-locking casters. Supports loads up to 400 pounds. Cart is included with Protector Demonstration Hood Systems
S28479, S79524B, 3945020 and 3945021. Dimensions: 39.0" w x 31.9" d x 36.0" h. Shipping weight 50 lbs. (23 kg)

Fluorescent Task Lights


For use with Protector XVS Ventilations Stations and Protector Demonstration Hoods. May be placed atop the enclosure
to enhance illumination of the interior. Include auxiliary electrical receptacle with switch for connection of accessories
such as a printer or airflow monitor.

Catalog # Description Shipping Wt. lbs./kg


S28152 115 volts, 60 Hz, 10 amps. Includes IEC, three-wire cord with plug. 15/7
3909201* 230 volts, 50 Hz, 10 amps. Includes IEC, three-wire cord. Plug is required (not included). 15/7

5248300 Waste Chute Stopper


For use with 5', 6' and 8' Protector XVS Ventilation Stations, 35.5" deep, with waste chute. When waste chute is not
in use, the stopper helps prevents contaminants from escaping from the enclosure through the side wall. Solid rubber.
5" diameter. Shipping weight 1 lb. (0.5 kg)

25
Accessories
Protector XVS Ventilation Stations & Protector® Demonstration Hoods
®

3925000 Utility Shelves


For use with Protector XVS Ventilation Stations. Three shelves attach to the rear baffle perforations to hold items such
as a balance printer, utensils and other miscellaneous supplies. The utensil shelf has a scalloped front edge to support
scalpels, forceps and other items. Powder-coated steel. Shipping weight 5 lbs. (2 kg)

3927700 Bottle Holder


For use with Protector XVS Ventilation Stations. Attaches to the rear baffle perforations to hold a squirt bottle or other
round container. Powder-coated steel. 3" diameter opening. Shipping weight 1 lb. (0.5 kg)

3927800 Tissue Holder


For use with Protector XVS Ventilation Stations. Attaches to the rear baffle perforations to hold tissue wipers in the
upside down position. An opening in the bottom of the holder permits wipers to be dispensed from the bottom. Powder-
coated steel. Shipping weight 1 lb. (0.5 kg)
3912400

3912402

Exhaust Transition Adapters


For use with Protector XVS Ventilation Stations and Protector Demonstration Hoods designed for outside ducting or
3912401 connected to the FilterMate Portable Exhauster.
3912400

Catalog3912402
# Description Shipping Wt. lbs./kg
3912402

3912400 Upper Exhaust Transition Adapter, 2.0" x 10.0" rectangular to 5.0" diameter
3912403 5/2
3912400 3912401
round for connection to 5" ID hose. Included with FilterMate Portable Exhauster.
3912401 Upper Exhaust Transition Adapter, 2.0" x 10.0" rectangular to 6.0" diameter 5/2
3912401
round for connection to 6" OD duct.
3912402 Lower Exhaust Transition Adapter, 2.0" x 10.0" rectangular to 5.0" diameter 5/2
round for connection to 5" ID hose.
3912402

3912403
3912403 Included with Protector Demonstration Hood System.
3912403 Lower Exhaust Transition Adapter, 2.0" x 10.0" rectangular to 6.0" diameter 5/2
round for connection to 6" OD duct.
3912402 3912403

Flexible Hose for FilterMate Portable Exhauster


3912403
For use with the FilterMate Portable Exhauster instead of the flexible polypropylene hose included. 8' length.
Include two clamps.

Catalog # Description Shipping Wt. lbs./kg

3927500 5" ID, clear urethane, smooth bore with white helix, static dissipative, 3/1
suitable for pharmaceutical and clean room applications.
3927600 6" ID, black thermoplastic rubber hose with 6.09" ID cuffs, suitable for 3/1
pharmaceutical and clean room applications. May be used to duct to the outside.
Requires 3927400 Adapter, sold separately. See page 27.

3913600 Thimble Connection Kit


For retrofitting FilterMate Portable Exhausters S28147, 3970020, S28149, 3970004 and 3970024. Included with FilterMate
Portable Exhausters S28150 and 3970022. Shipping weight 10 lbs. (4 kg)

*International electrical configuration.

26
Accessories
Protector XVS Ventilation Stations & Protector® Demonstration Hoods
®

Ductwork
Equivalent Shipping Wt.
Catalog # Description Resistance † lbs./kg

4708600 Thermoplastic Duct, 6.625" OD, 6.25" ID, 10' length 10' 25/11
4708900 Female PVC Duct Coupling, 6" nominal diameter, 0' 4/2
connects two sections of Thermoplastic Duct
4708700 90° PVC Elbow, 6" nominal diameter, has belled end connections 12' 1/0.5
to directly receive Thermoplastic Duct or Male Duct Coupling
3924000 Manual Exhaust Damper, powder-coated steel, 6" nominal diameter 1' 1/0.5
4724200 Manual Exhaust Damper, PVC, 6" nominal diameter 1' 1/0.5
4861800 Flexible Duct Connection, 7" nominal diameter, 1' 8/4
for use with 6" nominal diameter duct
3927400 Adapter, 5" round to 6" round, for use with 3927600 Hose 1' 1/0.5
4861700 Blower Transition Adapter, 4.25" x 7.75" rectangle to 6" diameter round 1' 3/1
4722200 Zero Pressure Weathercap, 6" nominal diameter, fits atop Thermoplastic Duct 5' 20/9

Equivalent resistance is measured in feet of straight duct.

Remote Blowers
A remote blower is required when ducting the Protector XVS Ventilation Station or Protector Demonstration Hood to the
outside. The direct drive blower has a 1/4 hp TEFC-type motor and overcomes external static pressure of 0.5" at 420 CFM.
Housing and impeller are corrosion-resistant, phenolic-coated steel. Blower inlet is 5.94" OD and is sized to accept 6" nominal
diameter PVC duct. Blower outlet is 4.25" x 7.4" OD. Dimensions: 14.6" w x 13.5" d x 13.25" high.

Catalog # Electrical Requirements Shipping Wt. lbs./kg

4863500 115 volts, 60 Hz, 4.4 amps 35/16


4863501* 115/230 volts, 50 Hz, 5.6/2.8 amps 35/16
7053501** 115 volts, 60 Hz 4.4 amps 40/18

CFM @ Static Pressure –Inches of H2O


S.P. 0.0" 0.125" 0.25" 0.50" 0.75" 0.87"
CFM 595 560 515 420 300 167

See Labconco Blower Booklet for more information.

3.1" 10.1" 1.25" 5.0" 6.0"


(8.0 cm) (25.7 cm) (3.2 cm) (12.7 cm) (15.2 cm)
4.0"
(10.2 cm)

5.0"
(12.7 cm)
5.9"
(15.1 cm)
OD

7.4" 7.1"
(18.75 cm) (18.1 cm)
8.25"
(21.0 cm)

4.25" 0.4" (1.0 cm) DIA.


(10.8 cm) 4.25" 4.25" 4 – HOLES
7.0" (10.8 cm) (10.8 cm)
0.5"
(17.8 cm) (1.3 cm) 9.4"
8.0" (23.8 cm)
(20.3 cm)
* International electrical configuration. **Explosion-proof

27
Accessories
Protector XVS Ventilation Stations & Protector ® Demonstration Hoods
®

Zero Pressure Weathercap Zero Pressure Weathercap


4722200 4722200
Remote
Blower Transition Adapter Blower Blower Transition Adapter 4861700
Remote Blower 4863500,
4861700
4863500, 4863501 4863501 or Flexible Duct Connection 4861800
or 7053501 7053501
Flexible Duct Connection 90° PVC Elbow 4708700
4861800
Lower Transition Adapter
90° PVC Elbow 4708700 3912403

Manual Exhaust Damper


Thermoplastic Duct
3924000 or 4724200
4708600
Upper Transition Adapter Thermoplastic Duct
3912401 4708600
Manual Exhaust Damper
Ducting Options 3924000 or 4724200

From Top From Bottom


90° PVC Elbow 4708700

Guardian™ 1000 Digital Airflow Monitors


Mount atop Protector XVS Ventilation Stations and Protector Demonstration Hoods in factory- prepared location. Monitor
and alert the operator to low airflow conditions. Include face plate with circuit board, electrical power pack, airflow hose,
flow hose adapter and glacier white powder-coated steel casing. LCD displays actual airflow in fpm or m/sec from 0 to
999 fpm (0 to 5.0 m/s). Audible/visual alarm alerts user to sustained low velocity condition. Calibration instructions
displayed on LCD. LED lights display red for alarm, yellow for caution, green for normal. Include temperature-compensated
sensor, external alarm, RS-232 port, night setback and alarm mute functions. UL* and CE listed.

Catalog # Electrical Requirements Shipping Wt. lbs./kg


S28151 115 volts, 60 Hz 10/5
3908801** 230 volts, 50 Hz 10/5

Guardian™ 500 Airflow Monitors


Mount atop Protector XVS Ventilation Stations and Protector Demonstration Hoods in factory-prepared location. Include
face plate with circuit board, electrical power pack, tubing, airflow tube adapter and glacier white powder-coated steel
casing. From the monitor’s face plate, the user can easily select and calibrate a setpoint between 30 and 250 fpm using a
velocity meter and a screwdriver. A green LED glows to indicate “safe” when airflow is greater than the low setpoint. A
red LED flashes to indicate “low” when airflow is below the low setpoint. An amber LED flashes when the sash is raised
above the maximum safe working opening. An audible alarm sounds (and can be muted) when under “low” and “sash
high” conditions. Include night setback, external alarm and alarm mute functions.

Catalog # Electrical Requirements Shipping Wt. lbs./kg


3944700 115 volts, 60 Hz 10/5
3944701** 230 volts, 50 Hz 10/5

*UL is a registered trademark of UL, LLC. **International electrical configuration

© 2015 Thermo Fisher Scientific Inc. All rights reserved.


Trademarks used are owned as indicated at www.fishersci.com/trademarks.

In the United States:


For customer service, call 1-800-955-1177
To fax an order, use 1-800-955-0740
To order online: www.fisheredu.com

© 2016 by Labconco Corporation Printed in the U.S.A. Product design subject to change without notice. Rev 040816 BN0630162