cr ’ TALBROS AUTOMOTIVE COMPONENTS LTD 14/1, Delhi Mathura Road , Faridabad - 121003 (HARYANA) LAB REPORT INO. 332-4 3. of of 6] 2] 2 SUPPLIER: — MAXWELLINDUSTRIES —_|MRIR NOMW.O.No & DATE LAB REQ. JWF220600407__29-06-2022__|NO. 332 MATERIAL; RC-O1A/NOR Coated 14310001FH [LOT QTY: 569 Kgs SAMPLE QTY: 01 NOS| CHARECTERISTICS ‘SPECIFICATION (As per MTL-026 ) SAMPLE RESULTS PHYSICAL TEST:-( Thickness ) 025X129 mm Base material ickness (mm) (0.2040.015 (0.208 2. Over al hckness mm) 0.2540.020 0.254 3 Thickness of rater One side (um) 2545, 24 [a Thickness of rubber oher side (um) 2585 22 5 Coating Bot side = Both side Both side [g. Pencilhardness = 2H 4 [7 Hardness HV 420 ~ 480 VPN 4357441 VPN 8. Adhesiveness (pa) min 20.0 min 16.35 NOT BREAK CHEMICALTEST 1. Coolant Resistance (soveqes0u0W)..100.°Cx..5irs.) 1.1 % Change in Thickness. 40 max 2143 112 adhesiveness 20.0 min 16.35_NOT BREAK [2Water Resistance (..95.°0x..5ihrs) 111 % Change in Thickness. 12 Adhesveness 20.0 min 16.35_NOT BREAK [30 Resistance (1030) ( .180.°0 x..5ihrs) “11 % Change in Thickness. “40 max 1434 112 Adhesiveness 20.0 min 16.35_NOT BREAK (4Fuel"C Resistance (..RT.°Cx..Shrs.) 1 Change in Apearnc To Appenrance ange | No Appearance Change 12% Changein Tene 50 max 1.449 1.3 Adhesiveness, 20.0 min 16.35 _NOT BREAK JOTHERS :- LAB REMARKS:- [ACCEPTED Cc Jconcessiona. \ Jaccertance =] [ze Stature PREPARED BY REJECTED Oo date Fon 0202