You are on page 1of 46

Exhibit 4 - Microwave AT Format

Product Name
The responsibilities specified shall apply as from MSP if not o
The ambit of this ATP is to specify ATP for MW Link & Network Performance, or as may be amende
Unless agreed otherwise, all amendments to this ATP must be recorded in writing and imp
Site Details
Planned
Site A
Site ID VISC01
NE -ID VISC01
Site Name ViscoResorts

Site Address Visco Resort-Mangal Dass S/O


Nokhu Ram Vill. Braun Po Dudar
Distt. Mandi Ph-01905-23736
Site Type (Indoor/Outdoor/IBS) OUTDOOR
Locator ID 11202-MOHP-2145065-CWIP-CL
TOCO( Indus,Infratel.GTL, Bharti Owned) INFRATEL

ToCo Site ID INFRATEL


Site Lat/Long 76.95304/31.68232
Azimuth to other site 242.33
Tower Height 40
Antenna Size (0.3, 0.6, 0.9, 1.2, 1.8 Mtrs)
ML15 0.6m HPX
Antenna Height (AGL- meters ) 40
Antenna Polarization (Horizontal / Vertical)
(As per planning guidelines) V+H

No. of Strut Rods installed (0/1/2) for 1.2/


1.8 mtr antennas (1.8M-2 Rods, 1.2M- 1 1
Rod is mandatory)
Path Length (kms) 2.57
FM Engg Name Dharamvir
Zone Mandi
Functional Test/Commissioning and Acceptan
Planned
Site A
Type of Equipment (MLE/MLTN, HC, FHY,
FHO, Ceragon, NEC, Huawei, DragonWave MLTN
Etc.)
TDM Link Capacity (4E1, 16E1,32E1, 75E1
NA
Etc.)
Ethernet Link Capacity (Mbps Etc.) 233
Backplane Software Version(Latest
R18T104
available version)
Software Version IDU
R18T104
(latest available version)
Software Version ODU R2A01
(latest available version)
Licence upto 300 MBPS installed
IDU/Magazine ( New/Existing) NEW
System Configuration ( PDH/ SDH/ Hybrid/
Packet) PACKET

Link configuration ( 1+0 / 1+1 / 2+0/


2+0
XPIC/1G)
Switch card redundancy (Y/N) N
Optical card redundancy (Y/N) N
Power card redundancy (Y/N) N
IDU Model ML6366
Sl. No. of IDU CN33839065
ODU Model ML-6363- 15/12H
Sl. No. of ODU CN33541960/CN33740823
Power Supply to ODU through PoE or
POE
direct
External Power Injector (Y/N) NA
Type of external Power Injector (2/4/8 NA
port, Indoor/outdoor)
Planned
Site A
Number of outdoor weatherproof CAT-6
1
cables
Outdoor weatherproof CAT-6 cables are
Y
armoured (Y/N)
Unused ODU ports are weatherproof
Y
capped (Y/N)
Protection Conduit for Patch
Cords ,Interconnections, OD power cable
Y
and E1 cable routing between 2 shelters or
2 different Cabinets.
Card type in IDU Slot No
MMU6366 1/1

Frequency Tx (MHz) 14935


Frequency Rx (MHz) 14515
Tx Power (dBm) 15

RSL(dBM) (<=2 dB Deviation permitted)*


-35.99
Modulation 28MHZ
Fade Margin 26.01
ATPC Enabled? (Y/N) N
ACM Enabled (Y/N) Y
Hi Lo Violation (Y/N) (No violation N
accepted)
RSL at near End when Far End Tx Power 93.4
Mute (Pl note value)
HOP visible in NMS (Y/N) (NMS Yes
Visibility is Mandatory)
HOP ID (standard nomenclature to be
configured in NMS also) VISC01-DYRI16

IP Address/Subnet Mask 10.64.65.72


Link is Licence alarm free (Y/N) (No Alarm N
accepeted Mandatory)
Link is alarm free (Y/N) (No Alarm
Y
accepeted Mandatory)

External Alarms extended for Outdooor


cabinets

Management IP address (if applicable) NA

Management VLAN ID (for DCN) NA


Conflict in Management & Traffic VLAN
N
(Y/N)

Unused VLAn configured in IDU (Y/N) N

Broadcast Limit configured on all Ethernet


N
Ports (Y/N)

All configured VLANs belongs to only one


Fiber POP (Y/N) N

Management of connecting 3rd party MW


N
equipment

Number of Ethernet ports used for traffic 1

QoS configured (Y/N) (As per planning Y


Instruction)

Loopback (RF, IF, NW) testing done (Y/N) Y

All Ethernet config as pe planning


Y
instruction (Y/N)
All TDM config as pe planning instruction
(Y/N) N.A

Ethernet throughput (in Mbps) 233

Optical receive level at optical IF ports 35

Clock Synchronization define (Y/N) (As


Y
per planning Instruction)

Latency ( End to end path )- Ring/ Chain N.A

Packet Drop ( End to end path )- Ring/ N.A


Chain
BH E1 till HO Point in ring protection((Y/N)) N.A
(Deviation to be captured separately)

Ring testing ( in case of ring) - SNCP/ ERPS


N.A
Switching ( OK/ NOT OK)
Auto Switching of traffic (Incase of TN/SDH
Hop-Ring) (OK/not OK) (forceful switching OK
testing mandatory)
Installation Checklist
Site A
Tx rack is fastened to floor & is clean.(No
Yes No
Shaking & dust free)

MW/ Tx rack DDU/ DCDB / Tx equipments Yes No


supply from critical LVD

Verify all MCBs on DDU/ DCDB/ SMPS are


labelled (Legible labelling) Yes No

Position of IDU magazine (Tx rack, BTS ,


Yes No
wall mount)
IDU & Magazine installaton
(nuts tighten & cards jacked completely in OK Not OK
slots)

Labelling of IF cable at Both End, ODU,


IDU, Power cable , Ethernet cables, PCM OK Not OK
( E1) cable, DDF, MCB etc is verified.
(Legible labelling)

Check All cables are routed inside the Tx


rack (Ethernet cables, E1 cables, power OK Not OK
cable, earthing cable etc) (No loose
hanging)

Protection Conduit for Patch


Cords ,Interconnections, OD power cable
OK Not OK
and E1 cable routing between 2 shelters or
2 different Cabinets.
IF cable/CAT6 routing is secured with IF
OK Not OK
clamps/Ties on cable tray.

Earthing of Tx rack is present & connected Yes No

Earthing of Magazine, DDU, IDU, Fan unit


& any other TX equipment is present & Yes No
connected
IDU Power Cable routing/ Labeling verified
(Legible labeling, crimped Lugs & coloured OK Not OK
PVC tape used)

IDU Grounding cable connection/ Labeling


Yes No
verified (crimped Lugs/Legible Labelling)

Earthing from Equipment bus bar of IDU


OK Not OK
connected (Crimped Lugs)

ODUs are mounted with all nuts & bolt in


Yes No
place and securely tightened

Verify DDF Rack & Krone Module


Yes No
grounded to the equipment earth
Verify IF connectors/RJ45 are locked while Yes No
terminated at IDU and ODU

Down bent given to IF cable/CAT6 at


Yes No
shelter entry
At ODU end the 1 Mtrs extra cable loop Yes No
tightened with tower.
At ODU the IF cable/CAT6 should not hang,
otherwise it will load ODU N type OK Not OK
connector
IF cable/CAT6 length (Mtrs) Yes No
Earthing of IF Cable/CAT6 connected to Yes No
Rack/ EGB
Weather proofing of IF cable/CAT6 at
earthing point done Yes No

Sealing of IF cable entry point to Shelter &


roxtec sealing at entry point to shelter Yes No
done

Antenna Clamps tightened with mounting


Yes No
pole (No loose clamping permitted)

Antenna is tightened with Pole (All nuts &


Yes No
bolts fixing the antenna are tightened)

The aligned positions of antenna, fixing


clamps, fine alignment rods, vertical Yes No
alignment rods and strut marked with thin
paint lines at multiple places

ODU is grounded (Y/N) Yes No


ODU/Antenna is marked with far end Site
Yes No
ID (Y/N)
Weather proofing of IF connector at ODUs
OK Not OK
(Water should not ingress)

MW Coupler/Strut rods fixing for 1.2,1.8


Mtr MW Antenna as per installation Yes No
guidelines (90 degree +- 15 degree)

All Dummies Installed (Y/N) Yes No

Fan units installed & working for magzine


for all types of equipments Yes No

Power Backup Available (Y/N) (pl note no


of hrs of backup) Yes No

Verify IDU Connected with Dual Power


Source Yes No

Grounding of Mast Yes No


Lightening arrestor Installed. Yes No
Grounding of Lightening arrestor Yes No
SACFA ID (Note Online ID)
All Nuts & Bolts used are ar per specification & recommen
All the deviation (if any) must be captured separately in Deviation format and

Stability Test: Statistics During 24 Hrs Test (On Need


Parameters
Result of 24 hrs. BER Test Acceptance Y
(Y/N)
TT ( Total Time)
AT ( Available Time)
ES ( Error Secods )
BBE ( Background BER )
SES ( Severly Error Seconds)
EB ( Error block)
Test to be error free

Site Layout Diagram Enclosed (Y/N)


MW BOQ sheet attached with wiring
(Y/N)
diagram & attached to MW Rack
Planning Design data sheet attached (Y/N)
Site Photograph for MW Ant, Cabling and
(Y/N)
Eqpt Attached

Signoff :

Project Engineer Name & Sign ( MC


Partner)

Engg FM Name & Sign ( MS Partner) Dharamvir

Project Manager Name & Sign (Bharti) Ajay kanwar

Mobile Number 9876049157

* EXCEPTIONAL CASES ONLY


Exhibit 4 - Microwave AT Format

Date:-
The responsibilities specified shall apply as from MSP if not otherwise stated.
cify ATP for MW Link & Network Performance, or as may be amended or added to in accordance with Mutual Agreement.
se, all amendments to this ATP must be recorded in writing and implemented in accordance with the agreement.
Site Details
Actual Planned Actual
Site A Site B Site B
VISC01 DYRI16 DYRI16
VISC01 DYRI16 DYRI16

ViscoResorts Dayari Dayari

Visco Resort-Mangal Dass S/O BSNL BSNL


Nokhu Ram Vill. Braun Po Dudar Sharing(MMZKEHANWAL1),Vill- Sharing(MMZKEHANWAL1),Vill-
Distt. Mandi Ph-01905-23736 Dayari,Tehsil & Mandi,HP Dayari,Tehsil & Mandi,HP
OUTDOOR OUTDOOR OUTDOOR
11202-MOHP-2145065-CWIP-CL 11202-MBLP-1059791-CWIP-CL 11202-MBLP-1059791-CWIP-CL
INFRATEL INFRATEL INFRATEL

INFRATEL INFRATEL INFRATEL


76.95304/31.68232 76.92883/31.67193 76.92883/31.67193
242.33 62.33 62.33
40 40 40

ML15 0.6m HPX ML15 0.6m HPX ML15 0.6m HPX


40 40 40

V+H V+H V+H

1 1 1

2.57 2.57 2.57


Dharamvir Dharamvir Dharamvir
Mandi Mandi
Functional Test/Commissioning and Acceptance
Actual Planned Actual
Site A Site B Site B

MLTN MLTN MLTN

NA NA NA

233 233 233

R18T104 R18T104 R18T104


R18T104 R18T104 R18T104

R2A01 R2A01 R2A01

installed installed installed


NEW New

PACKET PACKET PACKET

2+0 2+0 2+0

N N
N N
N N
ML6366 ML6366
CN33839065 CN33839110
ML-6363- 15/12H ML-6363- 15/12L ML-6363- 15/12L
CN33541960/CN33740823 CN33758797/CN33758757 CN33758797/CN33758757
POE POE POE

NA NA NA

NA NA NA

Actual Planned Actual


Site A Site B Site B

1 1 1

Y Y Y

Y Y Y

Y Y Y

Slot No Slot No
1/1 1/1

14935 14515 14515


14515 14935 14935
15 15 15

35.7/34.7 36.6/36.1
-35.99
28MHZ 28MHZ 28MHZ
26.01 26.01 26.01
N N N
Y Y Y

N N

93.4 94.2 94.2

Yes Yes

VISC01-DYRI16 VISC01-DYRI16 VISC01-DYRI16

10.64.65.72 10.64.65.73

N N N

Y Y

NA NA

NA NA

N N N

N N N

N N N

N N N

N N N

1 1 1

Y Y Y

Y Y Y

Y Y Y

N.A N.A N.A

233 233 233

35 35 35

Y Y Y

N.A N.A N.A

N.A N.A N.A


N.A N.A N.A

N.A N.A N.A

OK OK OK

Installation Checklist
Site A Site B

Yes No Yes No

Yes No Yes No

Yes No Yes No

Yes No Yes No

OK Not OK OK Not OK

OK Not OK OK Not OK

OK Not OK OK Not OK

OK Not OK OK Not OK

OK Not OK OK Not OK

Yes No Yes No

Yes No Yes No

OK Not OK OK Not OK

Yes No Yes No

OK Not OK OK Not OK

Yes No Yes No

Yes No Yes No
Yes No Yes No

Yes No Yes No

Yes No Yes No

OK Not OK OK Not OK

Yes No Yes No

Yes No Yes No

Yes No Yes No

Yes No Yes No

Yes No Yes No

Yes No Yes No

Yes No Yes No

Yes No Yes No

Yes No Yes No

OK Not OK OK Not OK

Yes No Yes No

Yes No Yes No

Yes No Yes No

Yes No Yes No

Yes No Yes No

Yes No Yes No
Yes No Yes No
Yes No Yes No

All Nuts & Bolts used are ar per specification & recommendations only
ation (if any) must be captured separately in Deviation format and to be approved by Circle CTO only

Stability Test: Statistics During 24 Hrs Test (On Need basis)


Site A Site B

Y Y Y

Test to be error free

Dharamvir OPS SPOC Name & Sign (Bharti)

Ajay kanwar Project Manager Name & Sign (SP)

9876049157 Mobile Number 9318516439


13-Sep

MS Remarks ( Ok/ Punch Point Details)


Additional Remarks

Additional Remarks

IP
Additional Remarks

Y
FAN Faulty & Door Open
alarms of O/D Cabinet to
be extended through
MW IDU

If yes to be taken up
with planning

If yes to be removed

As per Planning/OEM
suggestion

No Management/Traffic
VLAN of different Fiber
POP to be configured in
one IDU
Additional Remarks
Additional Remarks

ASHISH MEHRA

318516439
SHML59 SHML59 HPBSM01 31.09986 77.16337 Shimla-59 Shimla-59 Ramnagar
Plan release Date Plan category Project Sub category Plan status
21-Dec-20 XPIC Ops. MW HOP Utilization Pending

11-Jan-21 XPIC Ops. MW HOP Utilization Pending

DYRI16 DYRI16 VISC01 15_GHz_28_MHz_1 V+H


Deployment Date/Month Equipment Make New Site Hop Nomenclature Site-A

Ericsson DYRI16 VISC01


Ericsson DRGI01 LDWH99

VISC01 76.95304 31.68232 985.96


Hop Nomenclature Site-B Link ID Channel Polarization Site ID-A
V+H VISC01
DYRI16 VISC01-DYRI16 15_GHz_28_MHz_2
DRGI01 DRGI01-LDWH99 15_GHz_28_MHz_1 V+H DRGI01

15 14935 -35.99 242.33 40


Site A Lat Site A Long Tx Site Elevation (m) BER10e6 Tx Power (dBm) Tx Frequency (MHz)
76.95304 31.68232 985.96 15 14935

32.698 75.95892 2016.2 13 14935

76.95304/31.68232

ML15 0.6m HPX 36.6 51.6 DYRI16 76.92883


BER10e6 Rx Level (dBm) Tx Ant. Azimuth (°) Tx Ant. Height (m) Tx Antenna Site ID -B
-35.99 242.33 40 ML15 0.6m HPX DYRI16

ML15 0.9m HPX _2


-34.86 102.16 40 LDWH99
R1

31.67193 1216.59 14515 62.33 40


Site B Lat Site B Long Rx Site Elevation (m) Rx Frequency (MHz) Rx Ant. Azimuth (°)
76.92883 31.67193 1216.59 14515 62.33

32.68911 76.00558 1754.3 14515 282.16

76.92883/31.67193

ML15 0.6m HPX 36.6 MLT15_2X 225_1024Av2 H 2.57 28


Rx Ant. Height (m) Rx Antenna Rx Antenna Rx Ant. Gain (dB) Tx Radio
40 ML15 0.6m HPX MLT15_2X 225_1024Av2 H
42.7 MLT15_2X 225_1024Av2 H
ML15 0.9m ML15 0.9m HPX _2
30 41.1 MLT15_2X 225_1024Av2 H
HPX _2 R1 R1

26.01 0 26.01 100


Distance (km) Bandwidth (MHz) BER10e6 Eff. Margin (dB)
2.57 28 26.01

4.48 28 27.14
BER10e6 Rain Interference Thr. Deg. (dB) BER10e6 Total Perf. Year (Unav. %) Availability
0 0 100

0 0 100
ACM Status ACM Min QAM ACM Max QAM ATPC Status
(MODEM(IF Card)/Ethernet Port) Site-A (MW Chasis/CSR (CEN/EPT/NPT/BBU) Site-A
(MODEM(IF Card)/Ethernet Port) Site-B (MW Chasis/CSR (CEN/EPT/NPT/BBU) Site-B
Hop Dismantle Y / N Dismantle Hop ID Dismantle Hop Type Dismantle Hop Modem A
Dismantle Hop Chassis A Antenna Size Site-A Dismantle Hop Modem B
Dismantle Hop Chassis B Antenna Size Site-B Remarks Reason Revised Plan
Site ID R SITE ID (Active) BSC
VISC01 VISC01 HPERE01

Site ID R SITE ID (Active) BSC


DYRI16 DYRI16 HPERE01
LAT LONG
31.68232 76.95304

LAT LONG
31.67193 76.92883
ADDRESS
Visco Resort-Mangal Dass S/O Nokhu Ram Vill. Braun Po Dudar Distt. Mandi Ph-01905-23736

ADDRESS
BSNL Sharing(MMZKEHANWAL1),Vill-Dayari,Tehsil & Mandi,HP
Site Name
ViscoResorBaddi_Nalagarh_HP

Site Name
Dayari Baddi_Nalagarh_HP
Bharti Project Quality checking Form
BADI04 BA
Item 2: MCB installation
Site A Main MCB:

Item 5: IDU Grounding


Site A: @ IDU Part Site A: @ Bar Part Site B: @ IDU Part

Item 6: DDF installation


Site A: Site B:

NA

Item 7: IF cable laying


Site A: Site B:
Item 8: IF cable earthing
Site A: Site B:

NA NA NA

Item 9: ODU&Antenna installation


Site A: Site B:
Item 10: ODU Grounding
Site 1: Site 2:
ality checking Form
BADI89

Site B Main MCB:

Site B: @ IDU Part Site B: @ Bar Part

NA
NA

You might also like