Automatic engine shut-off

The function control engine shut-off when the conditions according to the table have been fulfilled, and informs the
operator that the engine will be shut off within 1 minute. When the engine is shut off the parking brake will also be
applied.

The operator can interrupt engine shut-off by affecting the throttle pedal, hand throttle or the gear selector.

Input signals Conditions for output functions Output functions

Overall conditions for the function


 VCADS Pro 1. Activation of the
parameter FAU function automatic
 VCADS Pro parameter FAU "On"
 VCADS Pro engine shut-off (4–99
parameter FAV min.)
 Directional gear, 2. When 1 minute
SW402  VCADS Pro parameter FAV "4–99
remains of the set time
 Accelerator minutes" WARNING Eng Shutoff
pedal, SE214  Directional gear in position N
APS  Accelerator pedal < 5% in 1 min[T1]
 Hand throttle,  Hand throttle not activated 3. Engine shut-off and
R205  Engine On parking brake applied
 Engine On/Off  Travel speed < 5 km/h (3 mph) (MA501 without
 Travelling speed voltage)

[T1] is shown. Engine shut-off is interrupted in case of activation of throttle pedal, hand throttle or the gear selector is
moved to position F or R.