@ ORION ITALIA INSTRUCTION MANUAL 1. DESCRIPTION The Earth Leakage Relay RD is a microprocessor base electronic protection device designed to recognize low level leakage or Unbalanced currents, due to insulation loss on conductors oF equipment to be protected. The fundamental feature ofthe RD is to allow preventive contol ‘of the system's insulation with continuous display of the earth Teakage current value of motors, transformers and power systems. The meas of the leakage currents is obiined by the use of a ringype current transformer. All cireuit conductors to be ‘protected shall go through the CT The RD product family includes: RD-7 panel mounting telay 72X72 RD-9 panel mounting relay 96x96 D-1 modular 35mm DIN rail For more info go to the Technical Features paragraph and read the installation instructions. ‘The RD family relays present the following features: * Dircet digital display ofthe earth leakage current * Digital display of the fault current percentage value of the ‘sipping. ‘+ Indipendent curent adjustments for alarm and tripping from 003A w 10.A, indipendent time adjustments for alarm and tripping from 003 05 Secs ‘Control of two operational relays: alarm relay (Alarm) and ‘ripping relay (Trip). + One digital input for exteral reset (only RD-1 model). “Indication and sorage, in @ nom volatile memory, of the last trip's fault current, “+ Manual test of output slays displays and leds * Local or automatic programmable reset. The aulomatic rest is Tocked out after 3 trips within 9 minutes time. + Continuous control of CT wiring connection ‘Thanks fo the digital HMI itis pombe to easily and precisely st the time and current values. The RD relay, thanks to it intemal filtering, is immune to external disturbances. is function is also guaranteed ‘with altemate sinusoidal and continually pulsating differential curents, abruptly ‘or applied which rise slowly (ype A) 2. INSTALLATION The RD should be installed according the characteristics of Inumidity and temperature tht has been designed to work i. To. minimize noise pickup and interference the relay should be placed away fiom high current conductors or sources of strong magnetic fies The Gieuit conductors shll be placed in the center ofthe ring type ‘eure teaneformer (as showed in the Ge) ‘Should the cables have a wide section and should they carry high levels of curet, avoid to place the single conductors fr from the ‘enter ofthe ring. In this case it wil be necessary that the diameter fof the Current Transformer shall be wider than the minimum necessary diameter. RD Earth leakage Protection Relay (64) ents, OK The RD-1 is design tobe installed over a din sail of 35mm _(go to last page), while the RD-T and the RD Ihave been stndiod for panel mounting 3. ELECTRICAL WIRING CONNECTIONS Fellow the digram on the last page. tention: Do not work on active circuits! The following points wil explain with more details: 3.1 Power Supply ‘Terminals 1 and2:115 Vac + 10%, -15% 50/6042 ‘Terminals I and 3:230 Vac + 10% -15%, S0/6OH note: KD does nt have intemal fas, important: Before doing the diclecric strength test of panel board, where the RD relay is installed, itis necessary to disconnect it from the power line voltage 3.2 CT connection ‘The terminal blocks 10 and 11 should be connected to the measuring windings of the CT by twisted cable. The used wire should not be less than 1 mm: and the distance should be as shor 1s possible (max. 10 mt of pir wire). NOTE: The CT wiring should be placod away from high current conductors or sources of stemg magnetic Fields, o minimize noise pickup and interference on the RD relay. Ifthe wires have only fone route, separate the wires with some metallic element IF shielded cables are used connect shield only to system ground 3.3 Output contacts connections ‘The oupits consist of two mechanical relays with ane changeover ‘contact. The TRIP relay will sctvate when the earth leakage ‘curent overcome the trip threshold for the specified delay time or in caso of problem with CT connection (sce programing) The ALARM relay will activate instantancously when the RD is ‘connected to line power, andi wll be deactivated when ‘= The earth leakage current overcome the alarm threshold for the specified delay time + The auxiliary voltage is out off. + Problem with the CT connection (se programming) NOTE: Using the contacts for control of inductive loads in Vac (cols of relays, contactors, solenoids), is necessary to limit the over current, or place a R/C group in parallel to the Inductor. It works in DC, a diode in anti-parallel should be ‘connected. The Internal relays are isolated 5 kV between ‘contact and eal 3.4 External reset wiring (only RD-1 model) ‘Connect terminals 12 4 13 to dry contact (see wiring diagram RD-I) Earth leakage Protection Relay (64) RD 4, FUNCTIONS AND SIGNALIZATIONS. Each time the RD relay is powered, an intemal check-up is made inside of the relay. The protection function will be available ‘within 300ms and the DISPLAY will start displaying the eurent levels in Ampere (normal functioning condition ater 5s. "Note: Inthe ease there isa wire interruption inthe connection, the message" EO" will appear on the display DISPLAY:in the (3) digit display, the user can abserve all the data of the RD: current levels, settings values and eror codes. “ALARM” LED The "ALARM" Ted timed on shows thatthe current has risen above the alarm setpoint and the programmed time. The respective contact bas activated the alarm, TRIP" LED: The "TRIP" led turned on shows that the cureat has risen above the tip setpoint and the programmed tip time The respective contact has activated the tip. 4.1 Set Mena From the normal functioning mode (spay of the current in ‘Ampete), poss the "W" baton fo exter the mont or fanetions {hom L01 {01.09 Thsallows to verify or modi the stings ach time the above mentioned baton is presse, i is posible fo 0 the next fancen, The RD will continue to aliemale the /—raulization of the function Lex and the coresponding vale Togo back to the normal condition just press the button Reset Test” “TO go back tothe previo function press the “A” baton. The following points vil explain in deta the complete mens: LOL Last trp: Displays the current value of the fs rip. The ‘ali stored in a no-olate men. [a2 ‘Trip Level, Displays the Ampere current value that correspon tthe trp threstold E03 Trip Time: Displays the delay time Gn seconds) related to the Ti Lat Almrm Leva: Displays tho Ampore current valoe tht omesponds to the Alarm threshold 108 Alarm Time: Displays the delay ime in second) relat to the Alarm L0G Auto Reset: Display if the automatic reset is ON or OFF in cane of Tip. Lo? Test made: Allows to visualize if the tet functions ofthe Alan and Trp relays is ON or OFF. If OFF, the TEST bution ‘lalla to test only the display and the ed 1108 CT error mode: Displays which eupt relay will be active in cam of conection peloms wit the toroidal transformer (ALE ‘Alan, TrP~ Trip ALL both, OFF no ray) 9 Trip mode: Dipays in which moe wil be operating the frp rely (LA = Latched

You might also like