Professional Documents
Culture Documents
219
219
Electric Drives Linear Motion and
and Controls Hydraulics Assembly Technologies Pneumatics Service
Ordering code
DBD 1X *
Pressure relief valve, direct operated
Type of adjustment Size
6 10 15 20 25 30
Screw adjustment with locknut ● ● ● ● ● ● =S
and protective cap
Handknob ● ● ● ● — — =H
Size =6 = 10 = 15 = 20 = 25 = 30 e.g..
SAE -4; -8; -12; -16; -20; -24;
7/16-20 3/4-16 1 1/16-12 1 5/16-12 1 5/8-12 1 7/8-12 = 10
Type of connection 6 10 15 20 25 30
for block mounting (cartridge) ● ● — ● — ● =K
for threaded connections ● ● ● ● ● ● =G
Series 10 to 19, (10 to 19, externally interchangeable) = 1X
Ordering code for
pressure range PSI
25 bar (365 PSI) ● ● — — — ● = 25
50 bar (725 PSI) ● ● ● ● — ● = 50
100 bar (1450 PSI) ● ● — ● ● ● = 100
200 bar (2900 PSI) ● ● ● ● ● ● = 200
315 bar (4600 PSI) ● ● — ● ● ● = 315
400 bar (5800 PSI) ● ● — ● — — = 400
630 bar (9150 PSI) — — — — — = 630
Thread options – Model “G” only
SAE threaded housing = 12
NBR seals, suitable for petroleum oils (HM, HL, HLP) = no code
Further details to be written in clear text
Technical data
Ordering code
DB 6 D W – 1X / V *
Pressure relief valve = DB = Further information in plain text
Nominal size 6 =6 No code = horizontal adjustment
Directly operated =D W65 = vertical adjustment
Technical data
General
Valve function Pressure relief valve, directly operated
Type of mounting Subplate, mounting hole configuration NG6, ISO 6264
Mounting position Optional
Ambient temperature range °C (°F) –25 to +50 (–13 to +122)
Weight Horizontal kg (lbs.) 1.4 (3.09)
Vertical kg (lbs.) 1.1 (2.42)
Hydraulic
Pressure fluid Mineral oil (HL, HLP) to DIN 51524, rapidly biodegradable pressure
fluids to VDMA 24568 (also see RE 90221), HETG (rapeseed oil),
HEPG (polyglycols), HEES (synthetic ester),
other pressure fluids available on request
Maximum permissible degree Class 20/18/15 1)
of contamination of pressure fluid
Purity class to ISO 4406 (c)
Pressure fluid temperature range °C (°F) –25 to +80 (–13 to +176)
Seals FPM (Viton® Dupont)
2
Viscosity range mm /s (SUS) 10 to 500 (45 to 2320)
Max. setting pressure bar (PSI) 80, 160 or 315 (1160, 2320 or 4500)
Max. working pressure bar (PSI) 315 (4500)
Max. flow rate l/min (GPM) 60 (15.85)
1)
The purity classes stated for the components must be complied with in hydraulic systems.
Effective filtration prevents problems and also extends the service life of components.
For a selection of filters, see catalog sections RE 50070, RE 50076 and RE 50081.
Ordering code
Z DB Y D – 1X / V / *
Modular valve =Z Further information in plain text
With 2 pressure valve =2 No code = mounting hole config.
cartridges (only enter for ISO 4401, without
versions “DC” and “DD”) locating bore
Pressure relief valve = DB 60 = mounting hole config.
ISO 4401 with
Mounting hole configuration =Y locating bore
to ISO 4401
V= FPM seals
Nominal size 6 = 60 (other seals available on request)
Nominal size 10 = 10 Note
Directly operated =D Take compatibility of seals and
Injection pressure fluid into account!
P to T =P max. setting pressure
A to T =A 180 = setting pressure range up to
B to T =B 80 bar (1160 PSI)
A to T and B to T =C 160 = setting pressure range up to
A to B and B to A =D 160 bar (2320 PSI)
Setting element 315 = setting pressure range up to
Sleeve with hexagon socket =2 315 bar (4500 PSI)
Rotary knob, lockable, with scale 1) =3 1X = Unit series 10 to 19
1)
2H key is included in scope of delivery (10 to 19: installation and connection
dimensions unchanged)
Technical data
Size 6 – General
Valve function Pressure reducing valve, directly operated
Type of mounting Intermediate plate NG6, ISO 4401-03-04-0-94
Installation position Optional
Weight Version 2 kg (lbs.) 1.4 (3.09)
Version 3 kg (lbs.) 1.8 (3.97)
Hydraulic
Pressure fluid Mineral oil (HL, HLP) to DIN 51524. Rapidly biodegradable pressure
fluids to VDMA 24568 (see also RE 90221), HETG (rapeseed oil),
HEPG (polyglycols), HEES (synthetic ester),
other pressure fluids available on request
Maximum permissible degree of contamination Class 20/18/15 1)
of pressure fluid. Purity class to ISO 4406 (c)
Pressure fluid temperature range °C (°F) –20 to +80 (–4 to +176)
Seals FPM (Viton® Dupont)
2
Viscosity range mm /s (SUS) 10 to 500 (45 to 2320)
Max. setting pressure bar (PSI) 80, 160 or 315 (1160, 2320 or 4500)
Max. working pressure bar (PSI) 315 (4500)
Max. flow rate l/min (GPM) 60 (15.85)
1)
The purity classes stated for the components must be complied with in hydraulic systems. Effective filtration prevents problems and
also extends the service life of components. For a selection of filters, see catalog sections RE 50070, RE 50076 and RE 50081.
Size 10 – General
Valve function Pressure reducing valve, directly operated
Type of mounting Intermediate plate NG10, ISO 4401-05-04-0-94
Installation position Optional
Weight Version 2 kg (lbs.) 2.9 (6.39)
Version 3 kg (lbs.) 3.5 (7.71)
Hydraulic
Pressure fluid Mineral oil (HL, HLP) to DIN 51524. Rapidly biodegradable pressure
fluids to VDMA 24568 (see also RE 90221), HETG (rapeseed oil),
HEPG (polyglycols), HEES (synthetic ester),
other pressure fluids available on request
Maximum permissible degree of contamination Class 20/18/15 1)
of pressure fluid. Purity class to ISO 4406 (c)
Pressure fluid temperature range °C (°F) –20 to +80 (–4 to +176)
Seals FPM (Viton® Dupont)
Viscosity range mm2/s (SUS) 10 to 500 (45 to 2320)
Max. setting pressure bar (PSI) 80 (1160) 160 or 315 (2320 or 4500)
Max. working pressure bar (PSI) 315 (4500) 315 (4500)
Max. flow rate l/min (GPM) 90 (23.78) 120 (31.70)
1)
The purity classes stated for the components must be complied with in hydraulic systems. Effective filtration prevents problems and
also extends the service life of components. For a selection of filters, see catalog sections RE 50070, RE 50076 and RE 50081.
Ordering code
– – 1X /
Subplate mounting No code = NBR seals
Pressure relief function = DBT (other seals available on request)
Pressure sequence function = DZT Note
Intermediate plate Take compatibility of seals and
Pressure relief function = ZDBT pressure fluid into account!
For installation in instrument panel =G 180 = setting pressure range
Mounting hole configuration to 3 to 80 bar (43 to 1160 PSI)
ISO 4401-03-02-0-94 =X 160 = setting pressure range
Function in A-duct =A 3 to 160 bar (43 to 2320 PSI)
Function in B-duct =B 315 = setting pressure range
Function in P-duct =P 3 to 315 bar (43 to 4500 PSI)
Technical data
General
Installation position Optional
Storage temperature range °C (°F) –20 to +80 (–4 to +176)
Ambient temperature range °C (°F) –20 to +70 (–4 to +158)
Weight kg (lbs.) 2.0 (4.4)
Hydraulic – measured with HLP 46; ϑoil = 40 °C ±5 °C (104 °F ±41 °F), v = 35 mm2/s (162 SUS)
Max. working pressure Port P bar (PSI) 350 (5075)
Max. setting pressure Pressure stage 160 bar (2320 PSI) bar (PSI) 160 (2320)
Pressure stage 315 bar (4500 PSI) bar (PSI) 315 (4500)
Pressure stage 350 bar (5075 PSI) bar (PSI) 350 (5075)
Min. setting pressure bar (PSI) 3 (43)
Return Port T bar (PSI) Separately to tank without pressure
Max. flow rate l/min (GPM) 3 (0.79)
Pressure fluid Mineral oil (HL, HLP) to DIN 51524 other pressure
fluids available on request
Pressure fluid temperature range °C (°F) –20 to +80 (–4 to +176)
Viscosity range mm2/s (SUS) 15 to 380 (70 to 1760)
Maximum permissible degree of contamination of pressure fluid Purity class Class 20/18/15 1)
to ISO 4406 (c)
Hysteresis % < 5 of max. setting pressure
Control oil volume (Vx) (for pressure sequence valves only) cm3 (in3) < 0.5 (0.03)
1)
The purity classes stated for the components must be complied with in hydraulic systems.
Effective filtration prevents problems and also extends the service life of components.
For a selection of filters, see catalog sections RE 50070, RE 50076 and RE 50081.
Model DBV 6 V
Ordering code
DB 6 V P W – 1X / V *
Pressure relief valve = DB Further information in plain text
Nominal size 6 =6 V= FPM seals
Pilot operated =V (other seals available on request)
Note
Pressure relief in P-duct =P Take compatibility of seals and
Mounting hole configuration to ISO 6264 =W pressure fluid into account!
Setting elements 180 = Secondary pressure
Sleeve with hexagon socket =2 160 = 6 to 80 bar (87 to 1160 PSI)
Rotary knob, lockable, with scale 1) =3 Secondary pressure
1)
2H key is included in scope of delivery 6 to 160 bar (87 to 2320 PSI)
1X = Unit series 10 to 19
(10 to 19: installation and connection
dimensions unchanged)
Technical data
General
Valve function Pressure relief valve, pilot operated
Type of mounting Subplate, mounting hole configuration NG6, ISO 6264
Installation position Optional
Ambient temperature range °C (°F) –25 to +50 (–13 to +122)
Weight kg (lbs.) 1.4 (3.09)
Hydraulic
Pressure fluid Mineral oil (HL, HLP) to DIN 51524.
Rapidly biodegradable pressure fluids to VDMA 24568 (see also RE 90221),
HETG (rapeseed oil), HEPG (polyglycols), HEES (synthetic ester),
other pressure fluids available on request
Maximum permissible degree Class 20/18/15 1)
of contamination of pressure fluid
Purity class to ISO 4406 (c)
Pressure fluid temperature range °C (°F) –25 to +80 (–13 to +176)
Seals FPM (Viton® Dupont)
Viscosity range mm2/s (SUS) 10 to 500 (45 to 2320)
Max. setting pressure bar (PSI) 80 or 160 (1160 or 2320)
Max. working pressure bar (PSI) 315 (4500)
Max. flow rate l/min (GPM) 60 (15.85)
1)
The purity classes stated for the components must be complied with in hydraulic systems.
Effective filtration prevents problems and also extends the service life of components.
For a selection of filters, see catalog sections RE 50070, RE 50076 and RE 50081.
Ordering code
Z DBK 6 – 1X / V *
Sandwich plate design =Z Further details to be
written in clear text
V= FPM seals, suitable for
Pressure relief valve = DBK
Petroleum oils (HM, HL, HLP)
Nominal size 6 (D 03) =6 Phosphate ester fluids (HFD-R)
Relief from: Other seal types on request
A→T = VA 50 = Adjustment range up to
P→T = VP 50 bar (725 PSI)
B→T = VB 100 = Adjustment range up to
100 bar (1450 PSI)
210 = Adjustment range up to
210 bar (3050 PSI)
1X = Series 10 to 19
(10 to 19 = externally interchangeable
Adjustment mechanism
2= Screw adjustment with locknut and protective cap
Technical data
Ordering code
Z DBK 10 – 1X V *
Sandwich plate design =Z Further details to be written in clear text
Port or cross port relief, =2 V= FPM seals, suitable for
Omit is single Petroleum oils (HM, HL, HLP)
Pressure relief valve = DBK Phosphate ester fluids (HFD-R)
Other seal types on request
Nominal size 10 (D 05) = 10
50 = Adjustment range up to 50 bar (725 PSI)
Relief from:
100 = Adjustment range up to 100 bar (1450 PSI)
A→T = VA
210 = Adjustment range up to 210 bar (3050 PSI)
P→T = VP
B→T = VB 1X = Series 10 to 19
A → T; B → T (Z2DBK) = VC (10 to 19 = externally interchangeable)
A → B; B → A (Z2DBK) = VD Adjustment mechanism
2= Screw adjustment with locknut
and protective cap
Technical data
Ordering code
Z DB 6 – 4X V *
Sandwich plate design =Z Further details to be written in clear text
Two pressure relief cartridges V= FPM seals, suitable for
(only available with Models 2VC2 Petroleum oils (HM, HL, HLP)
and 2VD2, see below =2 Phosphate ester fluids (HFD-R)
Pressure relief valve = DB Other seal types on request
Technical data
Ordering code
Z DB 10 – 4X V *
Further details to be written in clear text
Sandwich plate design =Z V= FPM seals, suitable for
Two pressure relief cartridges =2 Petroleum oils (HM, HL, HLP)
(only available with Models "VC" Phosphate ester fluids (HFD-R)
and "VD", see below) (other seal types on request)
Pressure relief valve = DB 50 = Adjustment range up to 50 bar (725 PSI)
Size 10 (D 05) = 10 100 = Adjustment range up to 100 bar (1450 PSI)
Relief from: 200 = Adjustment range up to 200 bar (2900 PSI)
P→T = VP 315 = Adjustment range up to 315 bar (4600 PSI)
A → TB and B → TB (Z2DB) = VC 4X = Series 40 to 49
A → B and B → A (Z2DB) = VD (40 to 49: externally interchangeable)
Adjustment mechanism
1= Rotary handwheel
2= Screw adjustment with locknut and protective cap
Technical data
Ordering code
DB 5X
A B
a b
Normally open =B
P T
*
Further details to be written in clear text
Threads for Y Port
12 = SAE (preferred)
No code = NBR seals suitable for petroleum oils (HM, HL, HLP
Attention!
The compatibilty of the seals and pressure
fluid has to be taken into account!
Electrical connections
K4 = Without plug-in connector, but covered
Central solenoid connections
DA = Terminal box with 1/2" NPT conduit conn.
DAL = Terminal box with two 1/2" NPT conduit conn.
ANSI B 93.55 M plug-in type connections
(without female end)
DK23L = Terminal box with 3-pin connector and light (single solenoid)
DK25L = Terminal box with 5-pin connector and light (single solenoid)
N9 = With protected override
Voltage
G 24 = Example DC – 12, 24, 96
W110 = Example AC1) – 110, 230
No code = Without directional valve
6E = With directional spool valve (3WE6…6X/E) settable pressure up to 420 bar (6100 PSI)
No code = Standard version
– = Pilot oil supply and drain line
1)
AC Voltage and Frequency
110 = 110V–50Hz, 110V–60Hz, 120V–60Hz
230 = 220V–50Hz, 220V–60Hz, 240V–60Hz
Technical data
General
Designation pressure relief valve
Mounting style subplate mounting, threaded connections or cartridge valve
Model of connection direct via threads;
indirect via subplate or manifold,
porting pattern to DIN 24 340 form A,
ISO 4401 and CETOP-RP 121 H
Nominal size 10 25 30
Weight DB. 10 DB. 20 DB. 30
Subplate mounting DB… kg (lbs.) 2.6 (5.73) 3.5 (7.71) 4.4 (9.7)
DBW… kg (lbs.) 4.07 (8.98) 4.97 (10.95) 5.87 (12.94)
Threaded connection DB..G… kg (lbs.) 5.3 (11.68) 5.1 (11.24) 4.8 (10.58)
DBW..G… kg (lbs.) 6.87 (14.93) 6.57 (14.49) 6.27 (13.82)
Installation optional
Hydraulic
Nominal pressure bar (PSI) 350 (5100)
Max. operating pressure at ports A, B, X bar (PSI) 350 (5100)
Max. back pressure at port Y
DB… bar (PSI) 315 (4600)
DBW… bar (PSI) 210 (3050) (high performance DC solenoid) (3WE6…6X/E)
bar (PSI) 2320 (high performance AC solenoid) (3WE6…6X/E)
Max. flow DB. 10 DB. 20 DB. 30
Subplate mounting L/min (GPM) 250 (66) 500 (132.1) 650 (171.7)
Threaded connection L/min (GPM) 250 (66) 500 (132.1) 650 (171.7)
Electrical technical data
Voltage DC
Nominal voltage V 12 ,24, 96
Nominal power W 30
Protection IP65
Permissible switching frequency 1/h 15000
Voltage AC
Nominal voltage V 110, 220, 50/60 Hz
Holding power VA 50
Inrush current VA 220
Protection IP65
Permissible switching frequency 1/h 7200
Model DB 20 K1-1X/...XY
Technical data
General
Mounting position Optional
Weight – Subplate mounting kg (lbs.) Size 20: 2.3 (5.1)
– Threaded connections kg (lbs.) DB – 2.95 (6.5), DBW – 4.25 (9.4)
– Manifold mounting kg (lbs.) 0.35 (0.8)
(cartridge)
Directional control valve data See data sheet RA 23 178
Hydraulic
Operating pressure, DB bar (PSI) ... 350 (5100)
ports A, B, X
Back pressure, port Y DB bar (PSI) ... 20 (3625)
Adjustable pressure min. bar (PSI) Flow dependent, see curves page 4
max. bar (PSI) ...50 (725), ...100 (1450), ...200 (2900), ...315 (4600),
...350 (5100) [5100 only Model DB]
Maximum flow Size 20
– Subplate mounting L/min (GPM) ... 400 (105)
– Threaded connections L/min (GPM) ... 300 (80)
Ordering code
DB *
Pilot operated pressure
relief valve = DB Further details to be
Without solenoid written in clear text
venting = no desig. W65 = Upright cartridge
with solenoid venting =W (code not required in manifold
mounted version, Model “K”)
Subplate mounting No code = NBR seals
Ordering NFPA/ANSI Subplates V= FPM seals
code interface available (other seals on request)
standard SAE Attention!
20 R 08 3/4" and 1" The compatibility of the seals and pressure
Threaded in-line connections fluid has to be taken into account!
Ordering SAE K4 = Without angled plug-in
code connector, but covered
20 1" -16; 1-5/16-12 DA = Terminal box with 1/2“ NPT
Cartridge model “K” conduit connection
for manifold mounting = 20 N9 = With protected manual override
Threaded connections for in-line mounting =G Voltage
Manifold mounting (cartridge) =K G 24 = Example DC – 12, 24, 96
W110 = Example AC – 110
Adjustment mechanism
Handknob =1 no desig. = without solenoid venting
Screw adjustment with locknut =2 6E = with removable solenoids
and protective cap no desig. = Minimum vent pressure when
Series 10 to 19 (model “K” only) = 1X valve is open A to B
(10 to 19; externally interchangeable)
Series 40 to 49 = 4X
(40 to 49; externally interchangeable)
Maximum Pressure Setting
... 50 bar (725 PSI) = 50
... 100 bar (1450 PSI) = 100
... 200 bar (2900 PSI) = 200
... 315 bar (4600 PSI) = 315
... 350 bar (5100 PSI) (only Model DB) = 350
Ordering code
DZ 6 D P – 5X *
Multi-function valve, Further details to be written in clear text
direct operated = DZ Gauge port connection
Size 6, NFPA/ANSI P 03 =6 12 = SAE threads
Direct operated =D no code = NBR-seals, suitable for
Petroleum oils (HM, HL, HLP)
Subplate mounted =P
no code = With reverse free-flow check valve
Adjustable handknob =1
Screw adjustment with locknut =2 no code = Internally piloted, internally drained
and protective cap X= Externally piloted, internally drained
Y= Internally piloted, externally drained
Series 50 to 59 = 5X
(50 to 59, externally interchangeable) 25 = Max. adjustable pressure 25 bar (365 PSI)
75 = Max. adjustable pressure 75 bar (1090 PSI)
150 = Max. adjustable pressure 150 (2175 PSI)
210 = Max. adjustable pressure 210 (3050 PSI)
Technical data
Ordering code
DZ 10 D P 2– *
Multi-function valve, Further details to be written in clear text
direct operated = DZ no code = NBR-seals, suitable for
Size 10, P 03 = 10 Petroleum oils (HM, HL, HLP)
V= FPM seals suitable for
Direct operated =D phosphate ester oils (HFD--R)
Subplate mounted =P no code = With reverse free-flow check valve
Screw adjustment with locknut =2 M= Without reverse fee-flow check valve
and protective cap no code = Internally piloted, internally drained
Y= Internally piloted, externally drained
Series 40 to 59 = 4X
XY = Externally piloted, externally drained
(40 to 49, externally interchangeable)
75 = Max. adjustable pressure 1.0 … 75 bar (15…1090 PSI)
210 = Max. adjustable pressure 1.0 … 210 bar (15…3050 PSI)
Technical data (For applications outside these parameters, please consult us!)
Ordering code
Technical data
Ordering details
DA 6 V – 4X / – *
Pressure cut-off valve = DA Further details in clear text
Nominal size 6 =6 No code = Without locating pin hole
/60 1) = With locating pin hole
Pilot operated =V
M= NBR seals
For subplate mounting:
V= FKM seals
• Pump connection in P (standard) =P
(other seals on request)
• Pump connection in A =A
As cartridge valve (without check valve) =K Attention!
Rotary knob =1 The compatibility of the seals and pressure
Sleeve with hexagon and protective cap =2 fluid must be taken into account!
Lockable rotary knob with scale =3 10 = Switching pressure differential 10%
Rotary knob with scale =7 17 = Switching pressure differential 17%
Series 40 to 49 = 4X Settable pressure range
(40 to 49: unchanged installation and connection dimensions) 50 = 30 to 50 bar (435 to 725 PSI)
1) 100 = 50 to 100 bar (725 to 1450 PSI)
Locating pin 3 x 8 DIN EN ISO 8752, Material No. R900005694
200 = 100 to 200 bar (1450 to 2900 PSI)
(separate order)
315 = 200 to 315 bar (2900 to 4500 PSI)
Technical data (for applications outside these parameters, please consult us!)
General
Installation Optional
Ambient temperature range °C (°F) –30 to +80 (–22 to +176) – NBR seals
–20 to +80 (–4 to +176) – FKM seals
Weight Manifold mounting kg (lbs.) 2.4 (5.29)
Cartridge valve kg (lbs.) 0.3 (0.66)
Hydraulic
Maximum operating pressure at ports B (P) bar (PSI) 315 (4500) – after switching P to T, A to T
Maximum flow L/min (GPM) 30 (7.93)
Pressure fluid Mineral oil (HL, HLP) to DIN 51 524 1);
Fast bio-degradable VDMA 24 568 (also see RE 90 221);
HETG (rape seed oil) 1); HEPG (polyglycols) 2);
HEES (synthetic ester) 2);
Other pressure fluids on request
Pressure fluid temperature range °C (°F) – 30 to + 80 (–22 to +176) – NBR seals
– 20 to + 80 (–4 to +176) – FKM seals
2
Viscosity range mm /s (SUS) 10 to 800 (45 to 3720)
Cleanliness class to ISO code Maximum permissible degree of contamination of the pressure
fluid is to ISO 4406 (C) class 20/18/15 3)
Switching differential % 10; 17 (see characteristic curves on page 5)
1)
Suitable for NBR and FKM seals
2)
Only suitable for FKM seals
3)
The cleanliness class stated for the components must be adhered too in hydraulic systems.
Effective filtration prevents faults from occurring and at the same time increases the component service life.
For the selection of filters see catalogue sheets RE 50 070, RE 50 076 and RE 50 081.
Ordering code
Z DRK 6 V P 5 – 1X Y *
Sandwich plate design = Z Further details to be written in clear text
Pressure reducing valve = DRK Gauge port connection
Size 6, D 03 =6 12 = SAE threads
Pilot operated =V V= FPM seals, suitable for
phosphate ester oils (HFD-R)
Pressure reduction in port P1 =P
M= without reverse free-flow check valve
Adjustment mechanism
Screw adjustment with locknut and protective cap =5 Y= Internally piloted, externally drained
Adjustable secondary "reduced" pressure range
Series 10 to 19 = 1X
50 = ... 50 bar (725 PSI)
(10 to 19; externally interchangeable)
100 = ... 100 bar (1450 PSI)
210 = ... 210 bar (3050 PSI)
Technical data
Ordering code
Z DR 6 D – 4X Y *
Sandwich plate design = Z Further details to be written in clear text
Pressure reducing valve = DR Gauge port connection
Size 6, D 03 =6 no code = metric threads
12 = SAE threads
Direct operated =D
no code = NBR seals, suitable for
Pressure reduction in port A2 =A petroleum oils (HM, HL, HLP)
Pressure reduction in port P1 =B
no code = with reverse free-flow check valve
(Pilot control signal from port B)
(Model ZDR 6 "DA" only)
Pressure reduction in port P1 =P
M= without reverse free-flow check valve
Adjustment mechanism Y= Internally piloted, externally drained
Rotary handwheel =1
Adjustable secondary "reduced" pressure range
Screw adjustment with locknut and protective cap =2
25 = ... 25 bar (365 PSI)
Series 40 to 49 (40 to 49; externally interchangeable) = 4X 75 = ... 50 bar (1090 PSI)
150 = ... 150 bar (2175 PSI)
210 = ... 210 bar (3050 PSI)
Technical data
Z DR 10 D – 5X Y 12 *
Further details to be written
Sandwich plate design = Z in clear text
Pressure reducing valve = DR Gauge port connection
12 = SAE threads
Size 10, D 05 = 10
no code = NBR seals, suitable for
Direct operated =D petroleum oils (HM, HL, HLP)
Pressure reduction in port A2 =A no code = with reverse free-flow check valve
Pressure reduction in port P1 =B (Model ZDR 6 "DA" only)
(Pilot control signal from port B) M= without reverse free-flow check valve
Pressure reduction in port P1 =P
Y= Internally piloted, externally drained
Adjustment mechanism Adjustable secondary "reduced" pressure range
Rotary handwheel =1 25 = ... 25 bar (365 PSI)
Screw adjustment with locknut and protective cap =2 75 = ... 75 bar (1090 PSI)
Series 50 to 59 (50 to 59; externally interchangeable) = 5X 150 = ... 150 bar (2175 PSI)
210 = ... 210 bar (3050 PSI)
Technical data (For applications outside these parameters, please consult us!)
Ordering code
DR 6 D P –5X Y *
Pressure reducing valve = DR Further details to be
Size 6, P 03 =6 written in clear text
Direct operated =D Gauge port connection
12 = SAE threads
Subplate mounted =P
no code = NBR seals, suitable for
Adjustment mechanism
petroleum oils (HM, HL, HLP)
Rotary handwheel =1
Screw adjustment with locknut and protective cap =2 no code = With reverse free-flow check valve
M= Without reverse free-flow check valve
Series 50 to 59 = 5X
(50 to 59; externally interchangeable) Y= Internally piloted, externally drained
Adjustable secondary "reduced" pressure range
... 25 bar (365 PSI) = 25
... 75 bar (1090 PSI) = 75
... 150 bar (2175 PSI) = 150
... 210 bar (3050 PSI) = 210
Technical data
Hydraulic fluid Petroleum oils (HM, HL, HLP); Phosphate ester fluids (HFD-R)
Operating pressure Port P bar (PSI) ... 315 (4600)
Reduced pressure Port A bar (PSI) ... 25 (365), ... 75 (1090), ... 150 (2175), ... 210 (3050)
Back pressure Port T (Y) bar (PSI) ... 160 (2320)
Maximum permissible flow L/min (GPM) ... 60 (16)
Weight (approx.) kg (lbs.) 1.2 (2.6)
Ordering code
Z DRK 10 V 5 – 1X Y *
Sandwich plate design = Z Further details to be written in clear text
Pressure reducing valve = DRK Gauge port connection
Size 6, D 03 = 10 12 = SAE threads
Pilot operated =V V= FPM seals, suitable for
phosphate ester oils (HFD-R)
Pressure reduction in port A2 =A
no code = with reverse free-flow check valve
Pressure reduction in port B2 =B
(Models VA and VB)
Pressure reduction in port P1 =P
M= without reverse free-flow check valve
Adjustment mechanism
Y= Internally piloted, externally drained
Screw adjustment with locknut and protective cap =5
Adjustable secondary "reduced" pressure range
Series 10 to 19 = 1X
50 = ... 50 bar (725 PSI)
(10 to 19; externally interchangeable)
100 = ... 100 bar (1450 PSI)
210 = ... 210 bar (3000 PSI)
Technical data
Ordering code
Z DR 10 V – 3X Y *
Further details to be
Sandwich plate des. = Z written in clear text
Pressure reducing valve = DR Gauge port connection
12 = SAE threads
Size 10, D 05 = 10
no code = NBR seals, suitable for
Pilot operated =V
petroleum oils (HM, HL, HLP)
Pressure reduction in port P1 =P
M= without reverse free-flow check valve
Adjustment mechanism
no code = with pressure gauge connection
Rotary handwheel =4
Y= Internally piloted, externally drained
Screw adjustment w/ locknut and protective cap =5
Adjustable secondary "reduced" pressure range
Series 30 to 39 = 3X
50 = ... 50 bar (725 PSI)
(30 to 39; externally interchangeable)
100 = ... 100 bar (1450 PSI)
200 = ... 200 bar (2900 PSI)
315 = ... 315 bar (4600 PSI)
Technical data
Operating pressure (Inlet ports A1, B1 or P2) bar (PSI) ... 315 (4600)
Reduced pressure (Outlet ports A2, B2 or P1) bar (PSI) ...50 (725), ...100 (1450), ...200 (2900), ...315 (4600)
Back pressure (Port TA, TB) bar (PSI) ... 160 (2320)
Maximum permissible flow L/min (GPM) ... 100 (26.4)
Weight (approx.) (Model VP) kg (lbs.) 2.3 (5.1)
Ordering code
Z DR Y 10 V – 1X / Y V *
Modular valve =Z Further information in plain text
Pressure reducing No code = FPM seals
valve = DR (other seals available on request)
3-way pressure reducing Note
valve =Y Take compatibility of seals
and pressure fluid into account!
Nominal size 10 = 10
No code = with check valve
Pilot operated =V
M= without check valve
Pressure reduction in A-duct =A
Y= Internal control oil supply,
Pressure reduction in B-duc =B
external control oil drain
Pressure reduction in P-duct =P
130 = Secondary pressure 4 to 30 bar (58 to 435 PSI)
Setting elements
180 = Secondary pressure 4 to 80 bar (58 to 1160 PSI)
Sleeve with hexagon socket =2
160 = Secondary pressure 8 to 160 bar (116 to 2320 PSI)
Rotary knob, lockable, with scale 1) =6
315 = Secondary pressure 8 to 315 bar (116 to 4500 PSI)
Unit series 10 to 19 = 1X
(10 to 19: installation and connection dimensions unchanged)
1)
2H key is included in scope of delivery
Technical data
General
Valve function Pressure reducing valve, pilot operated
Type of mounting Intermediate plate NG10, ISO 4401-05-04-0-94
Installation position Optional
Weight kg (lbs.) 2.7 (5.95)
Hydraulic
Pressure fluid Mineral oil (HL, HLP) to DIN 51524.
Rapidly biodegradable pressure fluids to VDMA 24568 (see also RE 90221),
HETG (rapeseed oil), HEPG (polyglycols), HEES (synthetic ester),
other pressure fluids available on request
Maximum permissible degree of contamination of Class 20/18/15 1)
pressure fluid Purity class to ISO 4406 (c)
Pressure fluid temperature range °C (°F) –20 to +80 (–4 to +176)
Seals FPM (Viton® Dupont)
Viscosity range mm2/s (SUS) 10 to 500 (46 to 2320)
Max. setting pressure (outlet) bar (PSI) 30 (435) 80 (1160) 160 (2320) 315 (4500)
Max. working pressure (inlet) bar (PSI) Setting pressure +120 (1740) Setting pressure +200 or 315 (2900 to 4500)
Max. flow rate l/min (GPM) 120 (31.7)
1)
The purity classes stated for the components must be complied with in hydraulic systems.
Effective filtration prevents problems and also extends the service life of components.
For a selection of filters, see catalog sections RE 50070, RE 50076 and RE 50081.
Ordering code
DR – 5X Y * Further details to be
Pressure reducing valve = DR written in clear text
Complete valve = no code 12 = SAE threaded housing (standard)
Subplate mounting no code = NBR seals, suitable for
petroleum oils (HM, HL, HLP)
Ordering NFPA/ANSI Subplates
code interface available no code = With reverse free-flow check valve
standard SAE (only for subplate mounted valves)
10 P 06 3/8" and 1/2" M= Without reverse free-flow check valve
20 P 08 3/4" and 1" Y= Internally piloted; externally drained
30 P 10 1-1/4" and 1-1/2" Maximum pressure setting
50 = ... 50 bar (725 PSI)
Subplate mounted = no code
100 = ... 100 bar (1450 PSI)
Adjustment mechanism 200 = ... 200 bar (2900 PSI)
Hand knob =4 315 = ... 315 bar (4600 PSI)
Screw adjustment with locknut and protective cap =5
5X = Series 50 to 59 (50 to 59; externally interchangeable)
Technical data
Ordering code
DR Y 12 * Further details to be
Pressure reducing valve = DR written in clear text
12 = SAE threaded housing (standard)
Threaded in-line connections “G”
no code = NBR seals, suitable for
Ordering petroleum oils (HM, HL, HLP)
code SAE M= Without reverse free-flow check valve
10 -8; 3/4-16 Y= Internally piloted; externally drained
20 -16; 1 5/16-12 Adjustable secondary “reduced” pressure range
50 = 10 … 50 bar (145... 725 PSI)
Threaded connection for in-line mounting =G
100 = 10 … 100 bar (145... 1450 PSI)
Adjustment mechanism 200 = 10 … 200 bar (145... 2900 PSI)
Rotary handknob =4 315 = 10 … 315 bar (145... 4600 PSI)
Screw adjustment with locknut and protective cap =5 4X = Series 40 to 49 (40 to 49; externally interchangeable)
Technical data
Size 10 20
Hydraulic fluid Petroleum oils (HM, HL, HLP); Phosphate ester fluids (HFD-R)
Fluid temperature range °C (°F) NBR seals: –30 to +80 (–22 to 176)
FPM seals: –20 to +80 (–4 to 176)
Viscosity range mm2/s (SUS) 10 to 800 (60 to 3170)
Maximum degree of fluid contamination Class 18/15 according to ISO 4406. Therefore, we recommend a
filter with a retention rate of ß10 ≥ 75.
Operating pressure, port B inlet bar (PSI) ... 315 (4600)
Reduced pressure, port A outlet bar (PSI) ... 50 (725), ... 100 (1450), ... 200 (2900), ... 315 (4600)
Backpressure, port Y bar (PSI) ... 250 (3625)
Flow Threaded housing for in-line mount L/min (GPM) 80 (21.1) 160 (42.3)
Ordering code
DR 10 D P – 4X Y *
Pressure reducing valve = DR Further details to be
Size 10, P 06 = 10 written in clear text
Direct operated =D 12 = SAE threaded
Subplate mounted =P gauge port
Rotary handknob =1 no desig. = NBR seals
Screw adjustment with locknut and protective cap =2 suitable for
Series 4X = 4X petroleum oils (HM, HL, HLP)
(40 to 49, installation and connection dimensions remain unchanged) no desig. = With reverse free-flow
Adjustable secondary “reduced” pressure range check valve
... 25 bar (365 PSI) = 25 M= Without reverse free-flow
... 75 bar (1090 PSI) = 75 check valve
... 150 bar (2175 PSI) = 150 Y= Internally piloted, externally drained
... 210 bar (3050 PSI) = 210
Technical data
Hydraulic fluid Petroleum oils (HM, HL, HLP), Phosphate ester fluids (HFD-R)
Fluid temperature range °C (°F) NBR seals: –30 to +80 (–22 to 176)
FPM seals: –20 to +80 (–4 ... 176)
Viscosity range mm2/s (SUS) 10 ... 800 (60 ... 3710) (dependent on fluid)
Maximum degree of fluid contamination Class 18/15 according to ISO 4406.
Therefore, we recommend a filter with a retention rate of ß10 ≥ 75.
Operating pressure Port B bar (PSI) up to 315 (4600)
Adjustable secondary pressure (output) Port A bar (PSI) ... 25 (365), ... 75 (1090), ... 150 (2175), ... 210 (3050)
Back pressure Port Y bar (PSI) up to 160 (2300)
Maximum flow L/min (GPM) up to 80 (21)
Installation position optional
Weight kg (lbs.) approx. 3 (6.6)
Ordering code
DA – – 5X – *
Without directional valve Further details to be
= No code written in clear text
Nominal size 10 = 10 No code = NBR seals
Nominal size 25 = 20 V= FPM seals
Nominal size 32 = 30 (other seals on request)
Adjustment elements Attention!
Rotary knob =1 The compatibility of the seals
Sleeve with internal hexagon and protective cap = 2 and pressure fluid has to be
Series 50 to 59 = 5X taken into account!
(50 to 59: unchanged installation and connection dimensions) No code = Internal pilot oil drain
Settable pressure range Y= External pilot oil drain
50 to 100 bar (725 to 1450 PSI) = 100 Switching pressure differential (P ➝ A)
100 to 200 bar (1450 to 2900 PSI) = 200 10 = In the mid range 10%
200 to 315 bar (2900 to 4600 PSI) = 315 17 = In the mid range 17%
Technical data
General
Nominal size Size 10 Size 25 Size 32
Weight DA… kg (lbs.) 2.6 (5.7) 13 (28.7) 27 (60)