Registration Gertificate Number: GARE lT 113312020

CERTIFICATE FOR THE REGISTRATION OF OPERATION OF GAS


TRANSMISSION ACTIVITIES FOR OWN USE

This registration certificate is issued by the National Energy Regulator of South


Africa, hereinafter referred to as "NERSA", in terms section 28 of the Gas Act,
2001 (Act No. 48 of 2001) ("the Gas Act"). This certificate is issued to:

CERAMIC INDUSTRIES PTY LTD


(Company Registration No: 1 982/008520/07)

herein after referred to as "the Registrant", only for the purpose of operating gas
transmission activities for own use in the Babelegi area of Gity of Tshwane
Metropolitan Municipality in the Gauteng province.

The registration under this certificate is subject to the requirements of the Gas
Act as stipulated in the Addendum hereto. The Registrant must comply with
these requirements.

ISSUED at Pretoria on this the day of 2020

NOMALANGA SITHOLE
SEAL
ACTING CHIEF EXECUTIVE OFFICER
rr (EzF
NATIONAL ENERGY REGULATOR
GT
OF SOUTH AFRICA

CONDITIONS FOR THE REGISTRATION OF OPERATION OF GAS


TRANSMISSION AGTIVITIES FOR OWN USE

TABLE OF CONTENTS

DEFINITIONS 3
CHAPTER ONE: REGISTERED ACTIVITY .......... 4
CHAPTER TWO: GENERAL CONDITIONS 7

Page 'l of 14
Annexure A: Map of the proposed piPeline
Annexure B: Block diagram
Annexure C: Mechanical flow diagram PRS
Annexure D: Standards

Page 2 of 14
DEFINITIONS

ln these registration conditions any word or expression to which a meaning has


been assigned in the Act shall have the meaning so assigned, unless the
context i nd icates otherwise.

"authorised person" means any person holding a valid authorisation permit


as defined by Rule.

"the Gas Act" means the Gas Act, 2001 (Act No. 48 of 2001).

"Rules" means Rules made by the NERSA in terms of section 34(3) of the Gas

Act and Rule has a corresponding meaning (Rule 19).

"Regulations" means regulations made in terms of section 34 of the Gas Act

Page 3 of 14
REGISTERED ACTIVITY

,,1. RegisteredOperation

1.1 NERSA has registered Ceramic lndustries (Pty) Ltd's operation of gas
transmission facility for own use in the Babelegi area of City of Tshwane
Metropolitan Municipality in the Gauteng province as indicated in
Annexure A.

1.2 The registered gas transmission facility for own use is located along the
following coordinates:

Table 1: Coordinates of Ceramic lndustries' transmission pipeline


PI COORDINATES LIST
PT Y. x- Latitude Longitude
COORD!NATE COORDINATES
S
SASOL Tie in point
Pt 0 73 002.633 2 804 426.399 250 20',40.60029" s "28'16'29.35510" E

SASOL CMS inlet


Pl14 72 992.8118 2 804 426.399 "25"20',40.60201" S "28"16',29.70629" E
SASOL GMS outlet
Pl 15 72 986.4427 2 804 426.399 "25"20',40.60313" S "28016',29.93404" E
Ceramic lndustries PRS lnlet
Pt 1 72 966.5429 2 804 426.399 "25'20'40.60664" S "28016'30.64564" E
Points along pipeline
Pl2 72 934.445 2 804 426.399 "25'20',40.61235" S "28'16',31.80772" E
Pt 3 72 932.7834 2 804 404.722 "25"20',39.90819" S "28"16',31.85703" E
Pt4 72 859.6165 2 804 405.3034 "25'20',39.93993" S "28016',34.47327" E
Pt 5 72 859.6165 2 804 389.0922 "25'20',39.41316" S "28'16',34.47640" E
Pt 6 72 819.7003 2804 407.655 "25"20',40.02337" S "28016'35.90016" E
P1 7 72 812.4916 2 804 413.3392 "25"20',40.20934" S "28'16'36.15684" E

P1 8 72 813.6275 2804 459.7795 "25"20',41.71823" S "28016'36.10724" E

Page 4 of 14
P1 I 72 775.3575 2 804 460.3476 "25'20',41.74340" S "28"16',37.47584" E
P1 11 72 859.6165 2 804 404.772 "25"20',39.92267" S "28'16',34.47337" E

P1 12 72 775.4112 2 804 464.738 "25"20',41.88605" S "28"16',37.47285" E

Tie-in factory 1

P1 10 72 857.9321 2 804 389.0922 "25"20',39.41345" S "28"16'34.53663" E

Tie-in factory 2
P1 13 72 775.7208 2 804 464.738 "25"20',41.99599" S "28'16',37.46178" E

1.3 This registration is granted to the registrant to operate the gas


transmission facilities, as indicated in Annexure C and Annexure D.

1.4 This registration only applies to gas conforming to the gas combustion
specifications as set out in table 2 below.

Table 2: Gas Combustion Specifications

Element Conditions Value


Energy content MJ/m3 (110,3 kPa (a) OoC 41,3 (t6o/o) MJim3
Gross content MJ/m3n (101,325 kPa (a) 15 oC 39 (t6%) MJ/m3n
Relative density 0,56 - 0,70
Wobbe lndex (Wl) 101,325 kPa (a) 15 oC 48,1 - 52,2
Sulphur (S) 15 mg m3n (max)

1.5 The entire list of the standards that Ceramic lndustries plans to abide by
when constructing the transmission facility is attached in the registration
conditions as Annexure D.

1.6 Table 3 below specifications of the gas transmission facility

Table 3: Specifications of the gas transmission facility


1.7 The Registrant may not transfer ownership of the registered gas
production operation to another party without the approval of NERSA,

1.8 ln addition to the above, the registrant must comply with all the
conditions that are specified in the construction licence of a gas
transmission facility (Gala.t. F11169812019). Furthermore, the
registrant must carry out the gas transmission activities in a manner
consistent with the objectives and provisions of the Act and must comply
with all the safety and maintenance codes and standards used for
operating a gas transmission facility.

2. Duration of the Certificate

2.1 The certificate is valid for an indefinite period from the date of issue, until
such time that the operations are terminated or discontinued for
whatever reasons.

Page 6 of 14
GENERAL REQUIREMENTS

3. Monitoring and Provision of lnformation

3.1 ln terms of regulation 9 of the Piped Gas Regulations, the Registrant


must provide NERSA with the following information within three months
of the end of each calendar year:
a) The actual and planned gas production quantities;
b) The specification details of the gas produced;
c) Gas intended for own exclusive use; and
d) The gas reserves data measured in trillion cubic feet (tcf).

3.2 The Registrant must notify NERSA in writing if during a calendar year
there is a substantial change in the information to be provided under
regulation 9 of the Piped-Gas Regulations.

3.3 ln terms of section 28(2) of the Gas Act, the Registrant must provide
NERSA with such information concerning the activities of the operation
as may be prescribed.

4. Gompliance

4.1 This certificate is granted only in terms of section 28 of the Gas Act and
for the activities specified and described in paragraph 1.1 above. This
certificate does not exempt the Registrant from compliance with any
other legislation.

5. Changes in Registrant's Particulars

5.1 The Registrant must at all times provide NERSA with the details of any
changes in the registered name, operating or trading name, registered
address and other contact details, including but not limited to, the names,
telephone numbers, facsimile numbers and email addresses of contact
persons.

Page 7 of 14
5.2 The notifications contemplated in paragraph 5.1 above must be provided
within fourteen (14) days of the event giving rise to them.

6. Correspondence with NERSA

6.1 All official communication by the Registrant with NERSA must be in

writing, signed and addressed to NERSA.

6.2 The Registrant must in all correspondence with NERSA quote the
registration reference number as it appears on this certificate.

Page I of 14
ANNEXURE A: Map of the proposed pipeline

o)
o)
o)
(tr
(L
Annexure B: Block diagram

\f
o
o
o
c,)
o
o_
Annexure C: Mechanical diagram PRS

o
o,
(5
o_
Annexure D: Standards
List all application:
a. Legislation
i. OHS- act and regulations - construction regulation, Pressure Equipment
Regulations (and Ceramic lndustries /SANS Standards) Major Hazardous,
nstallation Regulation.
I

ii. Gas Act Regulation and Rules


iii. Municipal bylaw and procedures
iv. EIA Regulation

b. Codes and specifications, including those related to safety to be used for


the activities applied for ASME, API EN etc.

i. General - The pipeline facility shall comply with prevailing legislation


applicable to the planning design construction, testing, commissioning and
operation of pipelines in the RSA SANS 347. The latest editions of all codes
and standards, including revisions and addenda, shall be applied.
ii. -
Primary Code The primary codes for the design, construction, testing,
commissioning and operation of operation of the pipeline facilities shall be;
1. ASME 831.8-2014 Gas Transmission and distribution piping system
2. ASME B31.3-2016 Process piping

iii. Supplementary Codes & Standards

1. API 5L: Specification for Line Pipe


2. API 6D: Specification for Pipeline Valves
3. API 6FA: Fire Test for Valves
4. API 1102: Steel Pipelines Crossing Railroads and Highways
5. API 1104: Standards forWelding Pipeline and Related Facilities
6. ASCE 7-98: Minimum Design Loads for Buildings and other structures
7. ASME 816.5: Pipe Flanges and Flanged fittings
8. ASME B{6.4a: Valve-Flanged, Threaded, and Welding End
L NACE RP0169-96: Control of external corrosion and underground or
submerged metallic piping systems.
10. NACE RP0268: Electrical lsolation of cathodically protected pipelines.
11. NACE RP0572: Design, installation, operation, and maintenance of
impressed current deep ground beds.
12. PRCI: lnstallation of pipelines by horizontal directional drilling

Page 12ot 14
General Sasol Gas'Codes and Standards used in qas pipelines

41: Codes
1. ASME B31.8: 2010 - Gas transmission and distribution systems;
2. 831.8S -2012 - Managing System lntegrity of Gas Pipelines;
3. NACE RP 0169 - Control External Corrosion of underground;
4. API RP 2201 - Safe Hot Tapping Practices in the Petroleum and
Petrochemical I ndustries;
5. ASME Vlll Div 1: Required applicable to the design, fabrication,
inspection, testing, and certification of pressure vessels;
6. ASME/ANSI B3{.1 - Requirements for materials and components,
design, fabrication, assembly, erection, examinations, inspection and
testing of piping;
7. API RP 520 - Sizing and selection of pressure relief devices;
8. NFPA 59A - Codes, standards, research, training and education on fire
hazards;

A2: National Standards


1. SANS 10268-2:2004 - Welding of Thermoplastics - Welding Processes
Part2: Electro fusion Welding;
2. SANS 10269:2O09 - Welding of thermoplastics - Testing and approval
of welders;
3. SANS 10270:2011 - Welding of Thermoplastics - Approval of Welding
procedures and welds;
4. -
SANS 347:2010 Categorisation and Conformity Assessment Criteria
for all Pressure Equipment;
5. SANS 10227:2007 - Criteria for the Operation of Inspection Authorities
Performing lnspection in Terms of the Pressure Equipment Regulations;
6. SANS 0121 - Cathodic Protection of buried and submerged structures;
and
7. SANS 12OO
8. SANS 329:2007 Edition 1 - lndustrial Thermo Processing Equipment.

B: Customer Meter Stations (CMS)


81. Codes
1. ASME B31.8:2010 - Gas transmission and distribution systems
2. B31.8S - 2012 - Managing System lntegrity of Gas Pipelines
3. ASME 816.5 - Pipe flanges and flanged Fittings
4. ASME 836.1M - 2004, Welded and Seamless Wrought Steel Pipe
5. ASME 816.9-2007 - Factory Made Wrought Butt welding Fittings
6. ASME 816.25 - Butt welding Ends
7. ASME 816.11 - Forged Fittings, Socket-welding and threaded
Page 13 of 14
8. ASME Vlll - Rules for Construction of Pressure Vessels
9. API 1 104 - Welding of pipelines and related facilities
-
10.APl RP520 Sizing, Selection and installation of pressure relieving
devices in refineries: Part I - Sizing and selection;
11.APl RP521 - Guide for pressure relieving and depressurising systems;
and
12.APl6D - Pipeline valves.

82. National Standards


1. SANS 10089-1 South Africa National Standard, Storage and
distribution of petroleum products in above ground bulk storage
installations;
2. SANS 10108 Classification of hazardous locations and selection of
-
electrical apparatus use in such location;
3. SANS 10142-1- The wiring premises;
-
4- SANS 1019 Standard voltages, currents and insulation level for
electricity supply;
5. SANS 347 Categorisation and conformity assessment criteria for all
-
pressure equipment;
6. SANS 10227:2007 - Criteria for the operation of inspection authorities
performing inspection in terms of the Pressure Equipment Regulations;
7. SANS 1091 - National Colour standards for paint;
8. SANS 10228 ldentification and classification of dangerous goods of
-
transport;
9. SANS 10231-Transport of dangerous goods: Operational requirements
for road vehicles;
10. SANS 10232-2- Transport of dangerous goods: Emergency information
systems;
11.SANS 10232-3 - Emergency response guides;
-
12.SANS29001: 2006 Sector specific quality management system for
petroleum, petrochemical and natural gas industries - requirements for
product and service supply organisations;
13. SANS347 - Pressure vessels and pressurised systems;
14.SANSl0227 lnspection in terms of the pressure equipment
regulations;
-
15.SANS 347 Categorisation and conformity assessment criteria for
pressure equipment and non-pressurised systems;
16.SANS 10227 Criteria for the operation of inspection authorities
-
performing inspection in terms of the pressure equipment regulations;
17. PER R374 dated 1 October 2009 - Pressure equipment regulation.