You are on page 1of 5
GT Engineering Consutting Ip Machinery Sarety Consulting Academy Insights Technical standards > ISO > IEC > ULand NFPA > CSA > ANSIB11 > ATEX Reserved Area Contacts Cerca: Qa ITA ENG EN ISO 13849-1: FUNCTIONAL SAFETY OF MACHINERY CONTACT US ANNEX F: ESTIMATION OF CCF Le misure da adottare per ridurre il rischio di guasti contemporanei CCF (Common Cause Failure) is defined as Failure which is the result of one or more events and which causes simultaneous failures of two or more separate channels in a multi channel system, leading to the failure of a safety related control function. There are several influencing factors: + The technology used + The architecture + The type of application + The environment in which the machine operates The CCF rate represents the frequency at which these faults occur ona channel and this is calculated as B¥Ag. The Standard EN 13849 establishes that the beta-factor () must be below 2%, It provides a series of measures to be taken to reduce 8. Table F.1 lists the measures and their scores, based on engineering judgement, which represent the contribution each measure makes in the reduction of common cause failures. The aim is to achieve a minimum score of 65/100 in order to have Bs2%. Table F.1 - Scoring process and quantification of measures against CCF GT Engineering Consutting Ip Machinery Sarety Consulting Academy Insights Technical standards > Iso > IEC > ULand NFPA > CSA > ANSI B11 > ATEX Reserved Area Contacts Cerca: Qa ITA ENG Ne ‘Measure against OOF 1_[Separation/ Segregation Pcl separation Between signal ath for example |— separation in wirin/ piping: |— detection af short circuits and open circuits in cables by dynamic tet, \— separate silting forthe signal pat ofeach channel |— suc clearances and cropage distances on printed cit boards 6 Different tchnolgies/desgn or physical pansples are used for ample \— test channel electronicor programmable ectronic and second channel eletrome (tania hardwired \— torent ination of stety funtion foreach channel (eg postion, pressue, tem iperatr and/or digital and analog measurement of variables distance, pressure or temperate) and/or {Components of siferent manufactures 20 3 ‘Desiga/aplication/experionce 2 [Components used are welltied 4 [assessmeont/analysis For each par of safety related pars af controlsystem a falre mode avd effet analysis has Inuncsried tant rerls taken im ecounts aoidcommon suse faresinthe sen 5 [Competence/tratning raining of designers to understand the causes and consequences of common cause allure © [Environmental ‘61 [For electrcalelecroni ystems, provention of contamination and elestromagnetic dis [turbance (EMC) to protect agains common case failures i accordance ith aprepeae| [standards EC 61326°31. ii systems fitration ofthe pressure medium, prevention of dirt intake, drsinageot com: Issel ncomplane wh hcompanen antares eee omg 22 [other intvences| consideration ofthe requrementsformmunitytallrelevant environmental nfiuences such as temperature, shock vibration, humidity es speced in relevant standards). wo "Total achievable ‘0 ‘Total score ‘Measures for avoiding COP [esorbeter Meets the requirements Less han 65 Process fled ~ choose ional measures NEW EDITION - 2023 O Index EN ISO 13849-1: Functional Safety of Machinery Annex C: MTTF calculation Annex F: Estimation of CCF New Edition - 2023 Attachments Vienna Agreement 2016 ISO CEN QO GT Engineering Consutting Ip Machinery Sarety Consulting Academy Insights Technical standards > Iso > IEC > ULand NFPA > CSA > ANSI B11 > ATEX Reserved Area Contacts Cerca: Qa ITA ENG SAFETY IN COLLABORATIVE ROBOTICS There is no “Collaborative Robot”. That is one of the first statements you hear. MORE DETAILS Insights Machinery Directive Process Safety Machinery safety Functional Safety UL and CSA Conformity Arc Flash ATEX Risk Gas Fournaces CE Marking, Consulting Conformity of Machinery Eletrical Panels Lockout-Tagout Machinery Directive: CE Marking, ATEX: CE Marking Engineering of UL and CSA Control Panels Academy Advanced Training on Functional Safety For Machinery EN ISO 13849-1 Functional Safety Electrical Hazard 2006/42/CE Machinery Directive 2014/34/UE ATEX Directive + Selectivity Studies, IEC + Risk Assessement and 60947-2 Risk Reduction * Machinery Revamping + Advanced Training on for Safety EN 60204-1 * ATEX 99/92/CE Directive * Machinery Safety: + Process Safety Lockout Tagout * Protection Against Procedure Lighting + ULSO8A, USA and * Electrical shock Risk Canadian Standards Analysis + UL508A: Industrial * Conformity to CSA Control Panels (Canadian) Technical Standards * Conformity to UL (USA) Technical Standards * Arc Flash Risk Analysis GT Engineering via Gutenberg 14 25020 PONCARALE (BS) Tel. 030 3581045 P.tva 03176130981 email info@gt-engineering. Cookie Policy - Privacy Policy - Cookie Preference crediti: Bizonweb srl Subscribe to the newsletter insert your email ) Non sono un robot recaercna, Pecy- Ter © agree with the Privacy Policy O agree to treatment of my personal data for the sending by e-mail of informative and promotional communications, as well as newsletters by the Owner in relation to its own initiatives and / or subsidiaries and / or associated companies, subscribe

You might also like