Professional Documents
Culture Documents
SURPASS HiT7035 R4 2 Acceptance Test Manual
SURPASS HiT7035 R4 2 Acceptance Test Manual
4.2
Statements of compliance
CE statement
The CE conformity declaration for the product is fulfilled when the system is built and cabled in line with the
information given in the manual and the documentation specified within it, such as installation instructions, cable
lists or the like. Where necessary project-specific documentation should be taken into consideration. Deviations
from the specifications or independent modifications to the layout, such as use of cable types with lower
screening values for example, can lead to violation of the CE protection requirements. In such cases the
conformity declaration is invalidated. The responsibility for any problems which subsequently arise rests with the
party responsible for deviating from the installation specifications.
Project Name:
Country:
Customer:
Station:
Product Version: hiT7035 R4.2L4.xx
Number of Pages:
Remarks:
Contents
1 Preface 8
3 Test result...........................................................................................11
Abbreviations.......................................................................................71
`
Summary of changes
1 Preface
The purpose of this manual is to provide the necessary test steps and their
explanations for an acceptance test of hiT7035 R4.2.
The “System-acceptance” personnel of the customer and/or of the
manufacturer will carry out the acceptance tests after installation and
commissioning.
If the system user wishes to perform the acceptance test procedures,
however, he must meet the following conditions:
• Training as a service engineer or equivalent,
• Sound knowledge of transmission technology,
• Appropriate device-specific training by the device manufacturer
providing him to get the required device and system knowledge for the
planned activity,
• PC operation knowledge,
• Basic knowledge of handling components, which are sensitive to
electrostatic discharges,
• Knowledge of handling optical fibbers and laser light sources.
2 Test Preparation
hiT7035 NE Load
TNMS-M Surpass hiT7035 LCT Load
3 Test result
PC/Laptop computer
MGMT
Port
NE
Note
This test is only done as field acceptance test if the User channel is used.
R
J
4
5
C
o
n
n
e
c
t
o
r
EOW
Product code P42022-A5248-H420 Port
© Nokia Siemens Networks 15 (72)
Issue 2.0 o
o
p
w
h o
r
R t
J
Fehler! Formatvorlage nicht definiert.
4
5
C
o
n
4.1.3.3 Test diagram: n
e
c
t
o Line
r SDH Analyzer
Port
L
o
4.1.3.4 Recommended Test Analyzer:
o
SDH Analyzer p
w
4.1.3.5 Test procedure: i
1. t one line port such as STM-1 port by LCT.
Create OHCC to
h
2. Insert RJ45 loop-connector to EOW port.
R
3. Run overhead BER
J on SDH analyzer for 5 minutes.
4 O at SDH analyzer.
4. Check for error free transmission
5 W
4.1.4 w
Function Test of EOW channels
i
t
h
4.1.4.1 Test Purpose:
This procedure tests Rthat EOW-Channels (E1 and E2) are working correctly.
J
4
5
Note
C field acceptance test if the User channel is used.
This test is only done as
o
n
n
e
c
t
o
16 (72) © Nokia Siemens Networks Product code P42022-A5248-H420
r
Issue 4.0
Fehler! Formatvorlage nicht definiert.
Note
This test is only done, if MDI/MDO is connected to a distributor (external equipment).
L
external fiber;
2. Do a short (few seconds) bit error test with the SDH/PDH analyzer for all
E1 ports;
3. Use PRBS15 for 2 Mbit/s tribs.
i
4.1.6.6 Expected Result:
No bit errors.
L
i
4.1.7.4 Recommended Test Analyzer: n
SDH/PDH Analyzer
L
i
4.1.8.4 Recommended Test Analyzer: n
SDH/PDH Analyzer
L
looped by external fiber;
2. Do a short (few seconds) bit error test with the SDH/PDH analyzer for all
STM-1E ports;
3. Use PRBS23 for STM-1E test.
i
4.1.9.6 Expected Result:
No bit errors.
e
Product code P42022-A5248-H420
Issue 4.0
Fehler! Formatvorlage nicht definiert.
PC/Laptop computer
MGMT Port
L L
i i
n n
e e
STM -1 NE
optical.
ODF
Power Meter
Mean launch
SFP Type ITU Order number
power
1310 nm short haul S4.1 S42025-L5132–A1 -15dBm …. -8dBm
1310 nm long haul L4.1 S42025-L5131–A1 -3dBm …. 2dBm
1550 nm long haul L4.2 S42025-L5130–A1 -3dBm …. 2dBm
1550 nm long haul V4.2 S42025-L5148–A1 0dBm …. 4dBm
Mean launch
SFP Type ITU Order number
power
1310 nm short haul S16.1 S42025-L5129–A1 -5dBm …. 0dBm
1310 nm long haul L16.1 S42025-L5128–A1 -2dBm …. 3dBm
1550 nm long haul L16.2 S42025-L5127–A1 -2dBm …. 3dBm
1550 nm long haul V16.2 S42025-L5141–A1 -2dBm …. 3dBm
1550 nm long haul U16.2 S42025-L5142–A1 -2dBm …. 3dBm
PC/Lapto
SFP Type ITU Order number Receiving power
1310 nm short haul S4.1 S42025-L5132–A1 -28dBm …. -8dBm
1310 nm long haul L4.1 S42025-L5131–A1 -28dBm …. -8dBm
1550 nm long haul L4.2 S42025-L5130–A1 -28dBm …. -8dBm
1550 nm long haul V4.2 S42025-L5148–A1 -34dBm …. -18dBm
M
Fehler! Formatvorlage nicht definiert.
PC/Lapto
SFP Type ITU Order number Receiving power
1310 nm short haul S16.1 S42025-L5129–A1 -18dBm …. 0dBm
1310 nm long haul L16.1 S42025-L5128–A1 -27dBm …. -9dBm
1550 nm long haul L16.2 S42025-L5127–A1 -28dBm …. -9dBm
1550 nm long haul V16.2 S42025-L5141–A1 -28dBm …. -9dBm
1550 nm long haul U16.2 S42025-L5142–A1 -28dBm …. -9dBm
M
Fehler! Formatvorlage nicht definiert.
Attenuator
Line card
Tx
Local station
Attenuator
Line card
Tx
Local station
Back-to-Back:
Latency
Back-to-Back:
Latency
Latency
Throughput:
Latency
Back-to-Back:
Latency
Back-to-Back:
Latency
PC/Laptop computer
Q-F
Remote Station
NE
NE
L L L L
i i i i
Local Station Remote Station
n n n n
e e e e
E1 E1
DDF
DDF
SDH Analyser
PC/Laptop computer
Q-F
Remote Station
NE
NE
L L L L
i i i i
Local Station Remote Station
n n n n
e e e e
E3 E3
DDF
DDF
SDH Analyser
PC/Laptop computer
Q-F
Remote Station
NE
NE
L L L L
i i i i
Local Station Remote Station
n n n n
e e e e
DS 3 DS 3
DDF
DDF
SDH Analyser
PC/Laptop computer
Q-F
Remote Station
NE
NE
L L L L
i i i i
Local Station Remote Station
n n n n
e e e e
STM - 1 STM - 1
DDF
SDH Analyser
PC/Laptop computer
Q-F
Remote Station
NE
NE
L L L L
i i i i
Local Station Remote Station
n n n n
e e e e
STM - 1E STM - 1E
DDF
DDF
SDH Analyser
PC/Laptop computer
Q-F
Remote Station
NE
NE
L L L L
i i i i
Local Station Remote Station
n n n n
e e e e
STM - 4 STM - 4
ODF
SDH Analyser
PC/Laptop computer
Q-F
Remote Station
NE
NE
L L L L
i i i i
Local Station Remote Station
n n n n
e e e e
STM - 16 STM - 16
ODF
SDH Analyser
PC/Laptop computer
MGMT Port
Remote Station
NE
NE
L L L L
i i i i
Local Station Remote Station
n n n n
e e e e
Data Analyzer
PC/Laptop computer
MGMT Port
Remote Station
NE
NE
L L L L
i i i i
Local Station Remote Station
n n n n
e e e e
Data Analyzer
PC/Laptop computer
MGMT Port
NE
NE
L L L L
i i i i
Local Station Remote Station
n n n n
e e e e
GE GE
Data Analyzer
Abbreviations