SURPASS hiT 7025

4.2

Acceptance Test Manual

Product code P42022-A5248-H420

© Nokia Siemens Networks 1 (72)


The information in this document is subject to change without notice and describes only the product
defined in the introduction of this documentation. This documentation is intended for the use of Nokia
Siemens Networks customers only for the purposes of the agreement under which the document is
submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means
without the prior written permission of Nokia Siemens Networks. The documentation has been
prepared to be used by professional and properly trained personnel, and the customer assumes full
responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the
process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or
performance of the mentioned hardware or software products are given “as is” and all liability arising
in connection with such hardware or software products shall be defined conclusively and finally in a
separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens
Networks has made all reasonable efforts to ensure that the instructions contained in the document
are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed
necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT
WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR
FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS
OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT
MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other
intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of
Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and
they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2007. All rights reserved.
Fehler! Formatvorlage nicht definiert.

Statements of compliance

CE statement

The CE conformity declaration for the product is fulfilled when the system is built and cabled in line with the
information given in the manual and the documentation specified within it, such as installation instructions, cable
lists or the like. Where necessary project-specific documentation should be taken into consideration. Deviations
from the specifications or independent modifications to the layout, such as use of cable types with lower
screening values for example, can lead to violation of the CE protection requirements. In such cases the
conformity declaration is invalidated. The responsibility for any problems which subsequently arise rests with the
party responsible for deviating from the installation specifications.

Product code P42022-A5248-H420 © Nokia Siemens Networks 3 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

Certificate of Customer Acceptance

Project Name:

Country:
Customer:
Station:
Product Version: hiT7035 R4.2L4.xx
Number of Pages:
Remarks:

Customer Acceptance Engineer:


NOKIA SIEMENS Networks
Engineer:
Date:
Sign for the customer: Sign for NOKIA SIEMENS Networks:

4 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Summary of changes

Contents

1 Preface 8

2 Test Preparation ..................................................................................9


2.1 Inventory List.......................................................................................9
2.1.1 Circuit Pack List of hiT7035..............................................................9
2.1.2 Load number of hiT7035 and hiT7035 LCT...................................10
2.2 Tools and Test Equipment List..........................................................10

3 Test result...........................................................................................11

4 Acceptance test procedure................................................................13


4.1 Interface Test....................................................................................13
4.1.1 Test of Battery Voltage...................................................................13
4.1.2 Check of the Management port.......................................................14
4.1.3 Function Test of User Channel (F1)................................................15
4.1.4 Function Test of EOW channels.....................................................16
4.1.5 Function Test of MDI/MDO.............................................................17
4.1.6 E1 (75ohm) Cabling Test................................................................18
4.1.7 E1 (120ohm) Cabling Test..............................................................20
4.1.8 E3/DS3 Cabling Test......................................................................22
4.1.9 STM-1E Cabling Test.....................................................................23
4.1.10 STM-1 Optical Mean Launch Power.............................................25
4.1.11 STM-4 Optical Mean Launch Power.............................................26
4.1.12 STM-16 Optical Mean Launch Power...........................................28
4.1.13 STM-1 Optical Receive Power......................................................30
4.1.14 STM-4 Optical Receive Power......................................................32
4.1.15 STM-16 Optical Receive Power....................................................34
4.1.16 BOA Transmit Power....................................................................36
4.1.17 POA Transmit Power....................................................................37
4.1.18 Ethernet Performance Test – RFC2544 test for 8xFE/T...............39
4.1.19 Ethernet Performance Test – RFC2544 test for 8xFE/L2.............44
4.1.20 Ethernet Performance Test – RFC2544 Test for 1xGE/T.............49
4.1.21 IMA Function Test........................................................................54
4.2 Network Test.....................................................................................55
4.2.1 Bit Error Test on E1 (12h)...............................................................55
4.2.2 Bit Error Test on E3 (12h)...............................................................57
4.2.3 Bit Error Test on DS3 (12h)............................................................58
4.2.4 Bit Error Test on Line Side (12h, STM-1 trib)..................................60
4.2.5 Bit Error Test on Line Side (12h, STM-1E trib)...............................61
4.2.6 Bit Error Test on Line Side (12h, STM-4 trib)..................................63
4.2.7 Bit Error Test on Line Side (12h, STM-16 trib)................................64
4.2.8 Packet Loss Test on Ethernet Card (12h, 8xFE/T).........................66
4.2.9 Packet Loss Test on Ethernet Card (12h, 8xFE/L2)........................67
4.2.10 Packet Loss Test on Ethernet Card (12h, 1xGE/T Card)..............69

Product code P42022-A5248-H420 © Nokia Siemens Networks 5 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

Abbreviations.......................................................................................71
`

6 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Summary of changes

Summary of changes

Re-issue date Reason Modified by Version


2007-7-13 Initial this document Wang Xiaowei 01
2007-7-24 Update RFC2544 reference results for 8xFE/T, Yan Junhua 02
8xFE/L2 and 1xGE/T
2007-7-31 Add document part number Yan Junhua 03
2007-8-6 Add IMA test notes Yan Junhua 04

Product code P42022-A5248-H420 © Nokia Siemens Networks 7 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

1 Preface
The purpose of this manual is to provide the necessary test steps and their
explanations for an acceptance test of hiT7035 R4.2.
The “System-acceptance” personnel of the customer and/or of the
manufacturer will carry out the acceptance tests after installation and
commissioning.
If the system user wishes to perform the acceptance test procedures,
however, he must meet the following conditions:
• Training as a service engineer or equivalent,
• Sound knowledge of transmission technology,
• Appropriate device-specific training by the device manufacturer
providing him to get the required device and system knowledge for the
planned activity,
• PC operation knowledge,
• Basic knowledge of handling components, which are sensitive to
electrostatic discharges,
• Knowledge of handling optical fibbers and laser light sources.

8 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

2 Test Preparation

2.1 Inventory List

2.1.1 Circuit Pack List of hiT7035

Slot name CP Type CP Code S/N number


SC
PWR1
PWR2
CC1_LC
CC2_LC
LC1
LC2
LC3
LC4
LC5
LC6
LC7
LC8
LC9
LC10
LC11
IO1

Product code P42022-A5248-H420 © Nokia Siemens Networks 9 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

Slot name CP Type CP Code S/N number


IO2
IO3
IO4
IO5
IO6
IO7
ST-CLK

2.1.2 Load number of hiT7035 and hiT7035 LCT

hiT7035 NE Load
TNMS-M Surpass hiT7035 LCT Load

2.2 Tools and Test Equipment List

Equipment Type Recommendation Actual Type


Bit Error test SDH/PDH Analyzer Agilent Omni718 with STM-16/4/1
set interface
IMA test set ATM Analyzer
Ethernet test IEEE802.3 data SmartBits 600 with FE module and GE
set Analyzer module
Optical Power meter Range –40…+10dBm
Optical test set Cleaning material
Fiber cables According to the delivered cards
Multimeter Range 0-1000V
Accuracy +/- 5%
ESD wristband

10 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

3 Test result

Test Item Test result Memo


Pass Fail
Test of Battery Voltage  

Communication Management Port  

Function Test of EOW  

Function Test of MDI/MDO  

Cabling Test for Connected  


E1(75ohm) port
Cabling Test for Connected
E1(120ohm) port
Cabling Test for Connected E3/DS3
port
Cabling Test for Connected STM-1E
port
STM-1 Optical Mean Launch Power  

STM-4 Optical Mean Launch Power  

STM-16 Optical Mean Launch Power  

STM-1 Optical Receive Power  

Product code P42022-A5248-H420 © Nokia Siemens Networks 11 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

Test Item Test result Memo


Pass Fail
STM-4 Optical Receive Power  

STM-16 Optical Receive Power  

Ethernet Performance Test-FE


 
BOA Transmit Power

POA Transmit Power

RFC2544 Test for 8xFE/T

RFC2544 Test for 8xFE/L2

RFC2544 Test for 1xGE/T

Bit Error Test on E1 (12h)

Bit Error Test on E3 (12h)

Bit Error Test on DS3 (12h)

Bit Error Test on Line Side (12h,


STM-1 trib)  
Bit Error Test on Line Side (12h,
STM-1E trib)
Bit Error Test on Line Side (12h,
STM-4 trib)
Bit Error Test on Line Side (12h,
STM-16 trib)

Packet Loss Test on 8xFE/T (12h,)  


Packet Loss Test on 8xFE/L2 (12h,)

Packet Loss Test on 1xGE/T (12h,)

12 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4 Acceptance test procedure

4.1 Interface Test

4.1.1 Test of Battery Voltage

4.1.1.1 Test Purpose:


To avoid damages caused by the DC voltage outside the specification, the
voltage needs to be checked before the initial power up of the system.

4.1.1.2 Test Setup:


Connect Multimeter with Power Distribution Panel, located on the top of the
rack

4.1.1.3 Test diagram:


NA

4.1.1.4 Recommended Test Analyzer:


Multimeter

4.1.1.5 Test procedure:


Use the Multimeter to check DC voltage at the Power Distribution Panel of the
rack for both power supply feeders.

4.1.1.6 Expected Result:


-40V to –72V

Product code P42022-A5248-H420 © Nokia Siemens Networks 13 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.1.7 Result Record

DC Voltage Comply with table above


Complied Not Complied
Input1

Complied Not Complied


Input2

4.1.1.8 Estimated Time consumption


0.1 hour

4.1.2 Check of the Management port

4.1.2.1 Test Purpose:


This test checks that the Management port is working correctly.

4.1.2.2 Test Setup:


Connect the Management port on the System Controller to a compatible 10 or
100Mbit Ethernet Interface. Use a cross over LAN cable for this connection.

4.1.2.3 Test diagram:

PC/Laptop computer

MGMT
Port

NE

4.1.2.4 Test procedure:


1. Login to the NE with hiT7035 LCT;
2. Do some configurations via hiT7035 LCT.

14 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.2.5 Expected result:


NE can be operated via LCT

4.1.2.6 Result Record:

  C omplied Not Complied

4.1.2.7 Estimated Time consumption


0.5 hour

4.1.3 Function Test of User Channel (F1)

4.1.3.1 Test Purpose:


This procedure tests that User-Channel (F1) is working correctly.

Note
This test is only done as field acceptance test if the User channel is used.

4.1.3.2 Test Setup:


1.
Loop with
Connect a SDH analyzer to one optical interface of NE;
RJ45
2. Loop EOW port with a RJ45 connector.
connetor
3. RJ45 loop-connector should be made as the figure shown:

R
J
4
5

C
o
n
n
e
c
t
o
r
EOW
Product code P42022-A5248-H420 Port
© Nokia Siemens Networks 15 (72)
Issue 2.0 o
o
p

w
h o
r
R t
J
Fehler! Formatvorlage nicht definiert.
4
5

C
o
n
4.1.3.3 Test diagram: n
e
c
t
o Line
r SDH Analyzer
Port

L
o
4.1.3.4 Recommended Test Analyzer:
o
SDH Analyzer p

w
4.1.3.5 Test procedure: i
1. t one line port such as STM-1 port by LCT.
Create OHCC to
h
2. Insert RJ45 loop-connector to EOW port.
R
3. Run overhead BER
J on SDH analyzer for 5 minutes.
4 O at SDH analyzer.
4. Check for error free transmission
5 W

4.1.3.6 Expected Result: C P


o o
The overhead BER should
n run errorr free
n t
4.1.3.7 Result Record: e
c
F1 Byte t Complied Not Complied
o
4.1.3.8 r
Estimated Time consumption
0.5 hour
p

4.1.4 w
Function Test of EOW channels
i
t
h
4.1.4.1 Test Purpose:
This procedure tests Rthat EOW-Channels (E1 and E2) are working correctly.
J
4
5
Note
C field acceptance test if the User channel is used.
This test is only done as
o
n
n
e
c
t
o
16 (72) © Nokia Siemens Networks Product code P42022-A5248-H420
r
Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.4.2 Test Setup:


1. Connect EOW box to EOW port on NE;
2. Connect phone to EOW phone port.

4.1.4.3 Test diagram:

EOW Line Line EOW EOW


EOW
Port Port Port Port BOX
BOX

7035 Local Station 7035 Remote Station

4.1.4.4 Test procedure:


1. Create OHCC to one line port such as STM-1 port by LCT.
2. Set phone number for every site.
3. Call each other.

4.1.4.5 Expected Result:


Communication can be established.

4.1.4.6 Result Record:

E1 byte Complied Not Complied


E2 byte Complied Not Complied

4.1.4.7 Estimated Time consumption


1 hour

4.1.5 Function Test of MDI/MDO

4.1.5.1 Test Purpose:


This procedure tests that MDI/MDO function of NE is working correctly.

Product code P42022-A5248-H420 © Nokia Siemens Networks 17 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

Note
This test is only done, if MDI/MDO is connected to a distributor (external equipment).

4.1.5.2 Test Setup:


Connect hiT7035 MDI/MDO interface with a distributor (external equipment).
For MDI, the active voltage range is -18V ~ -75V.
For MDO, the active activity is shortcut.

4.1.5.3 Test Diagram:


NA

4.1.5.4 Test procedure:


1. Configure MDI/MDO interface as required;
2. Check with test-equipment values on distributor.
For MDI, the active voltage range is -18V ~ -75V.
For MDO, the active activity is shortcut.
3. Additionally check alarms via hiT7035 LCT in MDI/MDO group.

4.1.5.5 Expected Result:


1. Test-equipment values on distributor will be changed according to
specification;
2. Alarms of hiT7035 NE will be changed according to the setting.

4.1.5.6 Result Record

MDO Complied Not Complied


MDI Complied Not Complied

4.1.5.7 Estimated Time consumption


1 hour

4.1.6 E1 (75ohm) Cabling Test

4.1.6.1 Test Purpose:


This test gives the steps required to check the E1 (75ohm) port cabling of the
hiT7035 63xE1 75ohm card.

18 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.6.2 Test Setup:


1. Connect SDH/PDH Analyzer to the E1 port;
2. Loop Line port with external fiber, using a 10dB attenuator if needed.

4.1.6.3 Test diagram:

4.1.6.4 Recommended Test Analyzer:


SDH/PDH Analyzer

4.1.6.5 Test procedure:


1. Create cross-connection from every E1 port to line port looped by

L
external fiber;
2. Do a short (few seconds) bit error test with the SDH/PDH analyzer for all
E1 ports;
3. Use PRBS15 for 2 Mbit/s tribs.

i
4.1.6.6 Expected Result:
No bit errors.

Product code P42022-A5248-H420


Issue 2.0
© Nokia Siemens Networks n 19 (72)
Fehler! Formatvorlage nicht definiert.

4.1.6.7 Result record:

  C omplied Not Complied

4.1.6.8 Estimated Time consumption


1 hour

4.1.7 E1 (120ohm) Cabling Test

4.1.7.1 Test Purpose:


This test gives the steps required to check the E1 (120ohm) port cabling of the
hiT7035 63xE1 120ohm card.

4.1.7.2 Test Setup:


1. Connect SDH/PDH Analyzer to the E1 port;
2. Loop Line port with external fiber, using a 10dB attenuator if needed.

20 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.7.3 Test diagram:

L
i
4.1.7.4 Recommended Test Analyzer: n
SDH/PDH Analyzer

4.1.7.5 Test procedure:


e
1. Create cross-connection from every E1 port to line port looped by
external fiber;
2. Do a short (few seconds) bit error test with the SDH/PDH analyzer for all
E1 ports;
3. Use PRBS15 for 2 Mbit/s tribs.

4.1.7.6 Expected Result:


No bit errors.

4.1.7.7 Result record:

Complied Not Complied

4.1.7.8 Estimated Time consumption


1 hour

Product code P42022-A5248-H420 © Nokia Siemens Networks 21 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.8 E3/DS3 Cabling Test

4.1.8.1 Test Purpose:


This test gives the steps required to check the E3/DS3 port cabling of the
hiT7035 E3/DS3 card.

4.1.8.2 Test Setup:


1. Connect SDH/PDH Analyzer to the E3/DS3 port;
2. Loop Line port with external fiber, using a 10dB attenuator if needed.

4.1.8.3 Test diagram:

L
i
4.1.8.4 Recommended Test Analyzer: n
SDH/PDH Analyzer

4.1.8.5 Test procedure:


e
1. Create cross-connection from every E3/DS3 port to line port looped by
external fiber;
2. Do a short (few seconds) bit error test with the SDH/PDH analyzer for all
E3/DS3 ports;

22 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

3. Use PRBS23 for 34 Mbit/s and PRBS15 for 45 Mbit/s tribs.

4.1.8.6 Expected Result:


No bit errors.

4.1.8.7 Result record:

Complied Not Complied

4.1.8.8 Estimated Time consumption


1 hour

4.1.9 STM-1E Cabling Test

4.1.9.1 Test Purpose:


This test gives the steps required to check the STM-1E port cabling of the
hiT7035 STM-1E card.

4.1.9.2 Test Setup:


1. Connect SDH/PDH Analyzer to the STM-1E port;
2. Loop Line port with external fiber, using a 10dB attenuator if needed.

Product code P42022-A5248-H420 © Nokia Siemens Networks 23 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.9.3 Test diagram:

4.1.9.4 Recommended Test Analyzer:


SDH/PDH Analyzer

4.1.9.5 Test procedure:


1. Create VC4 cross-connection from every STM-1E port to line port

L
looped by external fiber;
2. Do a short (few seconds) bit error test with the SDH/PDH analyzer for all
STM-1E ports;
3. Use PRBS23 for STM-1E test.

i
4.1.9.6 Expected Result:
No bit errors.

4.1.9.7 Result record:

Complied Not Complied

4.1.9.8 Estimated Time consumption


1 hour
n
24 (72) © Nokia Siemens Networks

e
Product code P42022-A5248-H420
Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.10 STM-1 Optical Mean Launch Power

4.1.10.1 Test Purpose:


The test verifies that the optical mean launched power of STM1 port is within
specification. The specification is based on the recommendations ITU-T
G.957.

4.1.10.2 Test setup:


Connect Optical Power Meter to the optical output interface of STM-1.

4.1.10.3 Test diagram:

PC/Laptop computer

MGMT Port

L L
i i
n n
e e

STM -1 NE
optical.

ODF

Power Meter

4.1.10.4 Recommended Test Analyzer:


Optical power meter

4.1.10.5 Test procedure:


1. Disable Auto laser shutdown function of the appropriate STM-1 port;
2. Record value of optical transmit power.

Product code P42022-A5248-H420 © Nokia Siemens Networks 25 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.10.6 Expected Result:

SFP Type ITU Order number Mean launch power


1310 nm short haul S1.1 S42025-L5135–A1 -15dBm …. -8dBm
1310 nm long haul L1.1 S42025-L5134–A1 -5dBm …. 0dBm
1550 nm long haul L1.2 S42025-L5133–A1 -5dBm …. 0dBm
1550 nm long haul V.1.2 S42025-L5149-A1 0dBm …. 4dBm

4.1.10.7 Result Record:

Mean launch Power in dBm Comply with table above


Slot
Port1 Port2 Port3 Port4
Complied Not Complied

Complied Not Complied

4.1.10.8 Estimated Time consumption


0.1 hour

4.1.11 STM-4 Optical Mean Launch Power

4.1.11.1 Test Purpose:


The test verifies that the optical mean launched power of STM-4 port is within
specification. The specification is based on the recommendations ITU-T
G.957.

4.1.11.2 Test setup:


Connect Optical Power Meter to the optical output interface of STM-4.

26 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.11.3 Test diagram:

4.1.11.4 Recommended Test Analyzer:


Optical power meter

4.1.11.5 Test procedure:


1. Disable Auto laser shutdown function of the appropriate STM-4 port;
2. Record value of optical transmit power.

4.1.11.6 Expected Result:

Mean launch
SFP Type ITU Order number
power
1310 nm short haul S4.1 S42025-L5132–A1 -15dBm …. -8dBm
1310 nm long haul L4.1 S42025-L5131–A1 -3dBm …. 2dBm
1550 nm long haul L4.2 S42025-L5130–A1 -3dBm …. 2dBm
1550 nm long haul V4.2 S42025-L5148–A1 0dBm …. 4dBm

Product code P42022-A5248-H420 © Nokia Siemens Networks 27 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.11.7 Result Record:

Mean launch Power in dBm Comply with table above


Slot
Port1 Port2 Port3 Port4
Complied Not Complied

Complied Not Complied

4.1.11.8 Estimated Time consumption


0.1 hour

4.1.12 STM-16 Optical Mean Launch Power

4.1.12.1 Test Purpose:


The test verifies that the optical mean launched power of STM-16 port is within
specification. The specification is based on the recommendations ITU-T
G.957.

4.1.12.2 Test setup:


Connect Optical Power Meter to the optical output interface of STM-16.

28 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.12.3 Test diagram:

4.1.12.4 Recommended Test Analyzer:


Optical power meter

4.1.12.5 Test procedure:


1. Disable Auto laser shutdown function of the appropriate STM-16 port;
2. Record value of optical transmit power.

4.1.12.6 Expected Result:

Mean launch
SFP Type ITU Order number
power
1310 nm short haul S16.1 S42025-L5129–A1 -5dBm …. 0dBm
1310 nm long haul L16.1 S42025-L5128–A1 -2dBm …. 3dBm
1550 nm long haul L16.2 S42025-L5127–A1 -2dBm …. 3dBm
1550 nm long haul V16.2 S42025-L5141–A1 -2dBm …. 3dBm
1550 nm long haul U16.2 S42025-L5142–A1 -2dBm …. 3dBm

Product code P42022-A5248-H420 © Nokia Siemens Networks 29 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.12.7 Result Record:

Mean launch Power in dBm Comply with table above


Slot
Port1 Port2 Port3 Port4
Complied Not Complied

Complied Not Complied

4.1.12.8 Estimated Time consumption


0.1 hour

4.1.13 STM-1 Optical Receive Power

4.1.13.1 Test Purpose:


The test verifies that the optical receive power of STM1 port is within
specification. The specification is based on the recommendations ITU-T
G.957.

4.1.13.2 Test setup:


Connect STM-1 optical input to the optical power meter.

30 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.13.3 Test diagram:

4.1.13.4 Recommended Test Analyzer:


Optical power meter

4.1.13.5 Test procedure:


1. Disable Auto laser shutdown function of the appropriate STM-1 port on
the remote station;
2. Record value of optical receive power in the table below.

4.1.13.6 Expected Result:

SFP Type ITU Order number Receiving power

1310 nm short haul S1.1 S42025-L5135–A1 -28dBm …. -8dBm

1310 nm long haul L1.1 S42025-L5134–A1 -34dBm …. -10dBm

Product code P42022-A5248-H420 © Nokia Siemens Networks 31 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

SFP Type ITU Order number Receiving power


1550 nm long haul L1.2 S42025-L5133–A1 -34dBm …. -10dBm
1550 nm long haul V1.2 S42025-L5149-A1 -34dBm …. -10dBm

4.1.13.7 Expected Result:

Receive Power in dBm Comply with table above


Slot
Port1 Port2 Port3 Port4
 C omplied Not Complied

Complied Not Complied

4.1.13.8 Estimated Time consumption


0.1 hour

4.1.14 STM-4 Optical Receive Power

4.1.14.1 Test Purpose:


The test verifies that the optical receive power of STM-4 port is within
specification. The specification is based on the recommendations ITU-T
G.957.

4.1.14.2 Test setup:


Connect STM-4 optical input to optical power meter.

32 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.14.3 Test diagram:

4.1.14.4 Recommended Test Analyzer:


Optical power meter

4.1.14.5 Test procedure:


1. Disable Auto laser shutdown function of the appropriate STM-4 port on
the remote station;
2. Record value of optical receive power in the table below.

4.1.14.6 Expected Result:

PC/Lapto
SFP Type ITU Order number Receiving power
1310 nm short haul S4.1 S42025-L5132–A1 -28dBm …. -8dBm
1310 nm long haul L4.1 S42025-L5131–A1 -28dBm …. -8dBm
1550 nm long haul L4.2 S42025-L5130–A1 -28dBm …. -8dBm
1550 nm long haul V4.2 S42025-L5148–A1 -34dBm …. -18dBm

Product code P42022-A5248-H420


Issue 2.0
© Nokia Siemens Networks 33 (72)

M
Fehler! Formatvorlage nicht definiert.

4.1.14.7 Result Record:

Receive Power in dBm Comply with table above


Slot
Port1 Port2 Port3 Port4
Complied Not Complied

Complied Not Complied

4.1.14.8 Estimated Time consumption


0.1 hour

4.1.15 STM-16 Optical Receive Power

4.1.15.1 Test Purpose:


The test verifies that the optical receive power of STM-16 port is within
specification. The specification is based on the recommendations ITU-T
G.957.

4.1.15.2 Test setup:


Connect STM-16 optical input to optical power meter.

34 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.15.3 Test diagram:

4.1.15.4 Recommended Test Analyzer:


Optical power meter

4.1.15.5 Test procedure:


1. Disable Auto laser shutdown function of the appropriate STM-16 port on
the remote station;
2. Record value of optical receive power in the table below.

4.1.15.6 Expected Result:

PC/Lapto
SFP Type ITU Order number Receiving power
1310 nm short haul S16.1 S42025-L5129–A1 -18dBm …. 0dBm
1310 nm long haul L16.1 S42025-L5128–A1 -27dBm …. -9dBm
1550 nm long haul L16.2 S42025-L5127–A1 -28dBm …. -9dBm
1550 nm long haul V16.2 S42025-L5141–A1 -28dBm …. -9dBm
1550 nm long haul U16.2 S42025-L5142–A1 -28dBm …. -9dBm

Product code P42022-A5248-H420


Issue 2.0
© Nokia Siemens Networks 35 (72)

M
Fehler! Formatvorlage nicht definiert.

4.1.15.7 Result Record:

Receive Power in dBm Comply with table above


Slot
Port1 Port2 Port3 Port4
Complied Not Complied

Complied Not Complied

4.1.15.8 Estimated Time consumption


0.1 hour

4.1.16 BOA Transmit Power

4.1.16.1 Test Purpose:


The test verifies that the BOA card transmit power.

4.1.16.2 Test setup:


Connect one optical card Tx into BOA Rx. If necessary, add an adjustable
attenuator to make the received optical power of BOA card in the allowed
range.

4.1.16.3 Test diagram:

Optical power meter


Tx
BOA
Rx

Attenuator
Line card
Tx

Local station

4.1.16.4 Recommended Test Analyzer:


Optical power meter

36 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.16.5 Test procedure:


1. Disable Auto laser shutdown function of the appropriate optical port on
the local station;
2. Adjust the attenuator to make the received optical power of BOA is in
range.
About input optical power range, please refer to the table list below:

BOA Type Optical power range


-10dBm …. 3dBm
13dBm BOA
-10dBm …. 3dBm
15dBm BOA
-10dBm …. 3dBm
18dBm BOA

3. Record values of BOA launch power.

4.1.16.6 Expected Result:

BOA Type Order number launch power


13dBm BOA S42024-L5465-A1 13dBm
15dBm BOA S42024-L5466-A1 15dBm
18dBm BOA S42024-L5467-A1 18dBm

4.1.16.7 Result Record:

BOA Type launch power


13dBm BOA
15dBm BOA
18dBm BOA

4.1.16.8 Estimated Time consumption


0.1 hour

4.1.17 POA Transmit Power

4.1.17.1 Test Purpose:


The test verifies that the POA card transmit power.

Product code P42022-A5248-H420 © Nokia Siemens Networks 37 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.17.2 Test setup:


Connect one optical card Tx into POA Rx. If necessary, add an adjustable
attenuator to make the received optical power of POA card in the allowed
range.

4.1.17.3 Test diagram:

Optical power meter


Tx
POA
Rx

Attenuator
Line card
Tx

Local station

4.1.17.4 Recommended Test Analyzer:


Optical power meter

4.1.17.5 Test procedure:


4. Disable Auto laser shutdown function of the appropriate optical port on
the local station;
5. Adjust the attenuator to make the received optical power of BOA is in
range.
About input optical power range, please refer to the table list below:

POA Type Optical power range


20dB POA -35dBm …. -15dBm

6. Record values of POA launch power.

4.1.17.6 Expected Result:

BOA Type Order number launch power


20dB POA S42024-L5468-A1 -15dBm …. 5dBm

38 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.17.7 Result Record:

POA Type launch power


20dB POA

4.1.18 Ethernet Performance Test – RFC2544 test for 8xFE/T

4.1.18.1 Test Purpose:


This test gives the steps required to measure the Ethernet performance of the
8xFE/T card of hiT 7035.

4.1.18.2 Test setup:


Connect the port1 and port2 of Data analyzer to port1 and port2 of FE card on
local station.

4.1.18.3 Test diagram:

4.1.18.4 Recommended Test Analyzer:


Data Analyzer

4.1.18.5 Test procedure:


Set up a 100M Ethernet traffic according to the test diagram, the step is as
followed:
1. Create 46 VC12 cross-connection from Ethernet card FE port1 to
CC_LC1 port.
2. Create 46 VC12 cross-connection from Ethernet card FE port2 to
CC_LC2 port
3. Use fiber to connect CC_LC1 port and CC_LC2 port.

Product code P42022-A5248-H420 © Nokia Siemens Networks 39 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4. Confirm the traffic can transfer along FE1(local)CC_LC1 port(local)


CC_LC2 port(local)FE2(local), and the reverse direction is as well.
5. Run the Data analyzer to measure the RFC2544.

4.1.18.6 Reference Result:


Throughput:

Frame Size Passed Rate (%) P1 to P2(pks /sec) Total


64 100 148810 148810
128 100 84459 84459
256 100 45290 45290
512 100 23496 23496
1024 100 11973 11973
1280 100 9615 9615
1518 100 8127 8127
1522 100 8106 8106
1536 100 8033 8033
Test duration (sec): 10 Number of trials: 1
Initial rate: 100 % Maximum rate: 100 %

Back-to-Back:

Frame Size Passed Rate (%) P1 to P2(Frames) Total


64 100 1488100 1488100
128 100 844590 844590
256 100 452900 452900
512 100 234960 234960
1024 100 119730 119730
1280 100 96150 96150
1518 100 81270 81270
1522 100 81060 81060
1536 100 80330 80330
Test duration (sec): 2 Number of trials: 1
Initial rate: 100 % Maximum rate: 100 %

40 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

Latency

Frame Size Rate Tested (%) P1 to P2(us)-S&F Average


64 100 526.2 526.2
128 100 532.0 532.0
256 100 541.3 541.3
512 100 564.5 564.5
1024 100 606.4 606.4
1280 100 625.0 625.0
1518 100 640.7 640.7
1522 100 641.5 641.5
1536 100 641.9 641.9
Test duration (sec): 10 Number of pairs: 1
Initial rate: 100 % Maximum rate: 100 %

Frame Packet Loss:

Frame Size Rate Tested (%) P1 to P2 (%) Average


64 100 0.000 0.000
128 100 0.000 0.000
256 100 0.000 0.000
512 100 0.000 0.000
1024 100 0.000 0.000
1280 100 0.000 0.000
1518 100 0.000 0.000
1522 100 0.000 0.000
1536 100 0.000 0.000
Test duration (sec): 10 Number of trials: 1
Initial rate:100 % Maximum rate: 100 %

Product code P42022-A5248-H420 © Nokia Siemens Networks 41 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.18.7 Result Record:


Throughput:

Frame Passed P1 to P2 Total Comply with table above


Size Rate(%) (pks/sec)
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 100.00% Maximum rate: 100.00%
Resolution rate: 1.00%

Back-to-Back:

Frame Passed P1 to P2 Total Comply with table above


Size Rate(%) (Frames)
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 100.00% Maximum rate: 100.00%
Resolution rate: 1.00%

42 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

Latency

Frame Rate P1 to P2(us)- Average Comply with table above


Size Tested (%) S&F
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 100 % Maximum rate: 100 %

Frame Packet Loss:

Frame Rate P1 to P2 (%) Average Comply with table above


Size Tested (%)
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 100% Maximum rate: 100%

4.1.18.8 Estimated Time consumption


4 hours

Product code P42022-A5248-H420 © Nokia Siemens Networks 43 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.19 Ethernet Performance Test – RFC2544 test for 8xFE/L2

4.1.19.1 Test Purpose:


This test gives the steps required to measure the Ethernet performance of the
8xFE/L2 card of hiT 7035.

4.1.19.2 Test setup:


Connect the port1 and port2 of Data analyzer to port1 and port2 of FE card on
local station.

4.1.19.3 Test diagram:

4.1.19.4 Recommended Test Analyzer:


Data Analyzer

4.1.19.5 Test procedure:


Set up a 100M Ethernet traffic according to the test diagram, the step is as
followed:
1. Configure both 8FE/L2 cards work on DoubleTag mode.
2. Configure LAN1 and LAN2 work on detag mode.
3. Configure WAN1 and WAN2 work on detag mode.
4. Configure both LAN1 and WAN1 with the same PVID such as 11, and in
the same VLAN list 11.
5. Configure both LAN2 and WAN2 with the same PVID such as 22, and in
the same VLAN list 22.
6. Create 46 VC12 cross-connection from Ethernet card WAN1 to CC_LC1
port.

44 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

7. Create 46 VC12 cross-connection from Ethernet card WAN2 to CC_LC2


port.
8. Use fiber to connect CC_LC1 port and CC_LC2 port
9. Confirm the traffic can transfer along FE1(local)CC_LC1 port(local)
CC_LC2 port(local)FE2(local), and the reverse direction is as well.
10. Run the Data analyzer to measure the RFC2544.

4.1.19.6 Reference Result:


Throughput:

Frame Size Passed Rate (%) P1 to P2(pks /sec) Total


64 100 148810 148810
128 100 84459 84459
256 100 45290 45290
512 100 23496 23496
1024 100 11973 11973
1280 100 9615 9615
1518 100 8127 8127
1522 100 8106 8106
1536 100 8033 8033
Test duration (sec): 10 Number of trials: 1
Initial rate: 100 % Maximum rate: 100 %
Back-to-Back:

Frame Size Passed Rate (%) P1 to P2(Frames) Total


64 100 1488100 1488100
128 100 844590 844590
256 100 452900 452900
512 100 234960 234960
1024 100 119730 119730
1280 100 96150 96150
1518 100 81270 81270
1522 100 81060 81060
1536 100 80330 80330
Test duration (sec): 10 Number of trials: 1
Initial rate: 100 % Maximum rate: 100 %

Product code P42022-A5248-H420 © Nokia Siemens Networks 45 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

Latency

Frame Size Rate Tested (%) P1 to P2(us)-S&F Average


64 100 304.4 304.4
128 100 319.1 319.1
256 100 349.3 349.3
512 100 404.6 404.6
1024 100 528.4 528.4
1280 100 589.5 589.5
1518 100 647.8 647.8
1522 100 649.2 649.2
1536 100 650.4 650.4
Test duration (sec): 10 Number of pairs: 1
Initial rate: 100 % Maximum rate: 100 %

Frame Packet Loss:

Frame Size Rate Tested (%) P1 to P2 (%) Average


64 100 0.000 0.000
128 100 0.000 0.000
256 100 0.000 0.000
512 100 0.000 0.000
1024 100 0.000 0.000
1280 100 0.000 0.000
1518 100 0.000 0.000
1522 100 0.000 0.000
1536 100 0.000 0.000
Test duration (sec): 10 Number of trials: 1
Initial rate:100 % Maximum rate: 100 %

46 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.19.7 Result Record:


Throughput:

Frame Passed P1 to P2 Total Comply with table above


Size Rate(%) (pks/sec)
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 100.00% Maximum rate: 100.00%
Resolution rate: 1.00%

Throughput:

Frame Passed P1 to P2 Total Comply with table above


Size Rate(%) (Frames)
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 100.00% Maximum rate: 100.00%
Resolution rate: 1.00%

Product code P42022-A5248-H420 © Nokia Siemens Networks 47 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

Latency

Frame Rate P1 to P2(us)- Average Comply with table above


Size Tested (%) S&F
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 100 % Maximum rate: 100 %

Frame Packet Loss:

Frame Rate P1 to P2 (%) Average Comply with table above


Size Tested (%)
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 100% Maximum rate: 100%

4.1.19.8 Estimated Time consumption


4 hours

48 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.20 Ethernet Performance Test – RFC2544 Test for 1xGE/T

4.1.20.1 Test Purpose:


This test gives the steps required to measure the Ethernet performance of the
GE card (1xGE/T) of hiT 7035.

4.1.20.2 Test setup:


1. Connect the GE1 port of Data analyzer to GE card1 on local station.
2. Connect the GE2 port of Data analyzer to GE card2 on local station.
3. Use fiber to connect the line card ports. If necessary, use a attenuator.

4.1.20.3 Test diagram:

4.1.20.4 Recommended Test Analyzer:


Data Analyzer

4.1.20.5 Test procedure:


Set up a GE Ethernet traffic according to the test diagram, the step is as
followed:
1. Create 4 VC4 cross-connection from GE card1 port to CC_LC1 port.
2. Create 4 VC4 cross-connection from GE card2 port to CC_LC2 port.
3. Use fiber to connect CC_LC1 port and CC_LC2 port.
4. Configure the local station Ethernet card , then we can confirm the traffic
can transfer along GE(local)CC_LC1 port(local)CC_LC2 port(local)
GE(local).
5. Run the Data analyzer to measure the RFC2544.

Product code P42022-A5248-H420 © Nokia Siemens Networks 49 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.20.6 Reference Result:


Throughput:

Frame Size Passed Rate (%) P1 to P2(pks /sec) Total


64 68.85 1024590 1024590
128 64.91 548246 548246
256 62.44 282805 282805
512 61.29 144009 144009
1024 60.63 72590 72590
1280 59.96 57657 57657
1518 59.98 48752 48752
1522 60.00 48638 48638
1536 59.43 47746 47746
Test duration (sec): 10 Number of trials: 1
Initial rate: 50 % Maximum rate: 70 %

Back-to-Back:

Frame Size Passed Rate (%) P1 to P2(Frames) Total


64 100.00 29061 29061
128 100.00 16493 16493
256 100.00 9946 9946
512 100.00 5161 5161
1024 100.00 2336 2336
1280 100.00 1874 1874
1518 100.00 1583 1583
1522 100.00 1582 1582
1536 100.00 1565 1565
Test duration (sec): 10 Number of trials: 1
Initial rate: 100 % Maximum rate: 100 %

50 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

Latency

Frame Size Rate Tested (%) P1 to P2(us)-S&F Average


64 60 60.7 60.7
128 60 62.7 62.7
256 60 65.7 65.7
512 60 67.5 67.5
1024 60 75.7 75.7
1280 60 80.6 80.6
1518 60 85.4 85.4
1522 60 86.0 86.0
1536 60 89.0 89.0
Test duration (sec): 10 Number of pairs: 1
Initial rate: 60 % Maximum rate: 60 %

Frame Packet Loss:

Frame Size Rate Tested (%) P1 to P2 (%) Average


64 60 0.000 0.000
128 60 0.000 0.000
256 60 0.000 0.000
512 60 0.000 0.000
1024 60 0.000 0.000
1280 60 0.000 0.000
1518 60 0.000 0.000
1522 60 0.000 0.000
1536 60 0.000 0.000
Test duration (sec): 10 Number of trials: 1
Initial rate: 60 % Maximum rate: 60 %

Product code P42022-A5248-H420 © Nokia Siemens Networks 51 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.20.7 Result Record:


Throughput:

Frame Passed P1 to P2 Total Comply with table above


Size Rate(%) (pks/sec)
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 50.00% Maximum rate: 70.00%
Resolution rate: 1.00%

Back-to-Back:

Frame Passed P1 to P2 Total Comply with table above


Size Rate(%) (Frames)
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 100.00% Maximum rate: 100.00%
Resolution rate: 1.00%

52 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

Latency

Frame Rate P1 to P2(us)- Average Comply with table above


Size Tested (%) S&F
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 60 % Maximum rate: 60 %

Frame Packet Loss:

Frame Rate P1 to P2 (%) Average Comply with table above


Size Tested (%)
64 Complied Not Complied
128 Complied Not Complied
256 Complied Not Complied
512 Complied Not Complied
1024 Complied Not Complied
1280 Complied Not Complied
1518 Complied Not Complied
1522 Complied Not Complied
1536 Complied Not Complied
Test duration (sec): 10 Number of trials: 1
Initial rate: 60% Maximum rate: 60%

4.1.20.8 Estimated Time consumption


4 hours

Product code P42022-A5248-H420 © Nokia Siemens Networks 53 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.1.21 IMA Function Test

4.1.21.1 Test Purpose:


The test verifies that the IMA basic function.

4.1.21.2 Test setup:


Connect the ATM analyzer 155M optical port to IMA IO port 1. Use fiber to
loop the line card such as STM-1 port.
Notes: Please restart the correlative IMA group, after the loop is removed.

4.1.21.3 Test diagram:

4.1.21.4 Recommended Test Analyzer:


ATM analyzer

4.1.21.5 Test procedure:


1. Assign an IMA group with 8 links.
2. Create a point to point VP/VC connection between IMA group and IMA
uplink. Such as IMA group related VPI/VCI is 255/300; IMA uplink
related VPI/VCI is 255/400
3. Create VC-12 cross connections between the IMA group related 8 IMA
E1 ports and line card stm-1 port.
4. Set up an ATM stream with VPI/VCI 255/400 on ATM analyzer, and run
with 16M bandwidth.

54 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.1.21.6 Expected Result:


Traffic is error free.

4.1.21.7 Result Record:

Complied Not Complied

4.1.21.8 Estimated Time consumption


30minutes

4.2 Network Test

4.2.1 Bit Error Test on E1 (12h)

4.2.1.1 Test Purpose:


This test gives the steps required to measure the line between two terminal
NE’s. The following item will be tested: Bit error measurement of E1 (12hours)

4.2.1.2 Test Setup:


1. Connect SDH/PDH Analyzer with hiT7035 E1 port on Local station;
2. Loop E1 port with external cable on remote station.

Product code P42022-A5248-H420 © Nokia Siemens Networks 55 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.2.1.3 Test diagram:

PC/Laptop computer

Q-F

Remote Station
NE
NE

L L L L
i i i i
Local Station Remote Station
n n n n
e e e e

E1 E1

DDF
DDF

SDH Analyser

4.2.1.4 Recommended Test Analyzer:


SDH/PDH Analyzer

4.2.1.5 Test procedure:


1. Create a VC12 level cross-connection from an appropriate E1 port to the
Line side on local station and remote station. A chain of more than one
Multiplex-section in line- or ring configuration is possible;
2. Do a bit error-measurement with the SDH/PDH analyzer and perform a
bit error-measurement with an injected payload of 2MBit/s during 12h
(PRBS15).

4.2.1.6 Expected Result


Error free.

4.2.1.7 Result Record

 Complied Not Complied

4.2.1.8 Estimated Time consumption


13 hours

56 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.2.2 Bit Error Test on E3 (12h)

4.2.2.1 Test Purpose:


This test gives the steps required to measure the line between two terminal
NE’s. The following item will be tested: Bit error measurement of E3 (12hours)

4.2.2.2 Test Setup:


1. Connect SDH/PDH Analyzer with hiT7035 E3 port on Local station;
2. Loop E3 port with external cable on remote station.

4.2.2.3 Test diagram:

PC/Laptop computer

Q-F

Remote Station
NE
NE

L L L L
i i i i
Local Station Remote Station
n n n n
e e e e

E3 E3

DDF
DDF

SDH Analyser

4.2.2.4 Recommended Test Analyzer:


SDH/PDH Analyzer

4.2.2.5 Test procedure:


1. Create a VC3 level cross-connection from an appropriate E3 port to the
Line side on local station and remote station. A chain of more than one
Multiplex-section in line- or ring configuration is possible;
2. Do a bit error-measurement with the SDH/PDH analyzer and perform a
bit error-measurement with an injected payload of 34MBit/s during 12h
(PRBS23).

Product code P42022-A5248-H420 © Nokia Siemens Networks 57 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.2.2.6 Expected Result


Error free.

4.2.2.7 Result Record

Complied Not Complied

4.2.2.8 Estimated Time consumption


13 hours

4.2.3 Bit Error Test on DS3 (12h)

4.2.3.1 Test Purpose:


This test gives the steps required to measure the line between two terminal
NE’s. The following item will be tested: Bit error measurement of DS3
(12hours)

4.2.3.2 Test Setup:


1. Connect SDH/PDH Analyzer with hiT7035 DS3 port on Local station;
2. Loop DS3 port with external cable on remote station.

58 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.2.3.3 Test diagram:

PC/Laptop computer

Q-F

Remote Station
NE
NE

L L L L
i i i i
Local Station Remote Station
n n n n
e e e e

DS 3 DS 3

DDF
DDF

SDH Analyser

4.2.3.4 Recommended Test Analyzer:


SDH/PDH Analyzer

4.2.3.5 Test procedure:


1. Create a VC3 level cross-connection from an appropriate DS3 port to
the Line side on local station and remote station. A chain of more than
one Multiplex-section in line- or ring configuration is possible;
2. Do a bit error-measurement with the SDH/PDH analyzer and perform a
bit error-measurement with an injected payload of 45MBit/s during 12h
(PRBS15).

4.2.3.6 Expected Result


Error free.

4.2.3.7 Result Record

 Complied Not Complied

4.2.3.8 Estimated Time consumption


13 hours

Product code P42022-A5248-H420 © Nokia Siemens Networks 59 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.2.4 Bit Error Test on Line Side (12h, STM-1 trib)

4.2.4.1 Test Purpose:


This test gives the steps required to measure the line between two terminal
NE’s. The following item will be tested: Bit error measurement of line side
(12hours, measured via STM-1trib)

4.2.4.2 Test Setup:


1. Connect SDH/PDH Analyzer with hiT7035 STM1 port on Local station;
2. Loop STM1 port with external fiber on remote station.

4.2.4.3 Test diagram:

PC/Laptop computer

Q-F

Remote Station
NE
NE

L L L L
i i i i
Local Station Remote Station
n n n n
e e e e

STM - 1 STM - 1

DDF

SDH Analyser

4.2.4.4 Recommended Test Analyzer:


SDH/PDH Analyzer

4.2.4.5 Test procedure:


1. Create a VC4 level cross-connection from an appropriate STM-1 port to
the Line side on local station and remote station. A chain of more than
one Multiplex-section in line- or ring configuration is possible;
2. Do a bit error-measurement with the SDH/PDH analyzer and perform a
bit error-measurement with an injected payload of 140MBit/s during 12h
(PRBS23).

60 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.2.4.6 Expected Result


Error free.

4.2.4.7 Result Record

Complied Not Complied

4.2.4.8 Estimated Time consumption


13 hours

4.2.5 Bit Error Test on Line Side (12h, STM-1E trib)

4.2.5.1 Test Purpose:


This test gives the steps required to measure the line between two terminal
NE’s. The following item will be tested: Bit error measurement of line side
(12hours, measured via STM-1E trib)

4.2.5.2 Test Setup:


1. Connect SDH/PDH Analyzer with hiT7035 STM1E port on Local station;
2. Loop STM1E port with external cable on remote station.

Product code P42022-A5248-H420 © Nokia Siemens Networks 61 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.2.5.3 Test diagram:

PC/Laptop computer

Q-F

Remote Station
NE
NE

L L L L
i i i i
Local Station Remote Station
n n n n
e e e e

STM - 1E STM - 1E

DDF
DDF

SDH Analyser

4.2.5.4 Recommended Test Analyzer:


SDH/PDH Analyzer

4.2.5.5 Test procedure:


1. Create a VC4 level cross-connection from an appropriate STM-1E port
to the Line side on local station and remote station. A chain of more than
one Multiplex-section in line- or ring configuration is possible;
2. Do a bit error-measurement with the SDH/PDH analyzer and perform a
bit error-measurement with an injected payload of 140MBit/s during 12h
(PRBS23).

4.2.5.6 Expected Result


Error free.

4.2.5.7 Result Record

 Complied Not Complied

4.2.5.8 Estimated Time consumption


13 hours

62 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.2.6 Bit Error Test on Line Side (12h, STM-4 trib)

4.2.6.1 Test Purpose:


This test gives the steps required to measure the line between two terminal
NE’s. The following item will be tested: Bit error measurement of line side
(12hours, measured via STM-4 trib)

4.2.6.2 Test Setup:


1. Connect SDH/PDH Analyzer with hiT7035 STM4 port on Local station;
2. Loop STM4 port with external fiber on remote station.

4.2.6.3 Test diagram:

PC/Laptop computer

Q-F

Remote Station
NE
NE

L L L L
i i i i
Local Station Remote Station
n n n n
e e e e

STM - 4 STM - 4

ODF

SDH Analyser

4.2.6.4 Recommended Test Analyzer:


SDH/PDH Analyzer

4.2.6.5 Test procedure:


1. Create a VC4 level cross-connection from an appropriate STM-4 port to
the Line side on local station and remote station. A chain of more than
one Multiplex-section in line- or ring configuration is possible;

Product code P42022-A5248-H420 © Nokia Siemens Networks 63 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

2. Do a bit error-measurement with the SDH/PDH analyzer and perform a


bit error-measurement with an injected payload of 140MBit/s during 12h
(PRBS23).

4.2.6.6 Expected Result


Error free.

4.2.6.7 Result Record

Complied Not Complied

4.2.6.8 Estimated Time consumption


13 hours

4.2.7 Bit Error Test on Line Side (12h, STM-16 trib)

4.2.7.1 Test Purpose:


This test gives the steps required to measure the line between two terminal
NE’s. The following item will be tested: Bit error measurement of line side
(12hours, measured via STM-16 trib)

4.2.7.2 Test Setup:


1. Connect SDH/PDH Analyzer with hiT7035 STM-16 port on Local station;
2. Loop STM-16 port with external fiber on remote station, if necessary add
a 10dB attenuator when loop the STM-16 port.

64 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.2.7.3 Test diagram:

PC/Laptop computer

Q-F

Remote Station
NE
NE

L L L L
i i i i
Local Station Remote Station
n n n n
e e e e

STM - 16 STM - 16

ODF

SDH Analyser

4.2.7.4 Recommended Test Analyzer:


SDH/PDH Analyzer

4.2.7.5 Test procedure:


1. Create a VC4 level cross-connection from an appropriate STM-16 port to
the Line side on local station and remote station. A chain of more than
one Multiplex-section in line- or ring configuration is possible;
2. Do a bit error-measurement with the SDH/PDH analyzer and perform a
bit error-measurement with an injected payload of 140MBit/s during 12h
(PRBS23).

4.2.7.6 Expected Result


Error free.

4.2.7.7 Result Record

Complied Not Complied

4.2.7.8 Estimated Time consumption


13 hours

Product code P42022-A5248-H420 © Nokia Siemens Networks 65 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.2.8 Packet Loss Test on Ethernet Card (12h, 8xFE/T)

4.2.8.1 Test Purpose:


This test gives the steps required to measure the line between two terminal
NE’s. The following item will be tested: Packet Loss measurement of line side
(12hours, measured via 8xFE/T)

4.2.8.2 Test Setup:


Connect Data Analyzer port1 and port2 with hiT 7035 8xFE/T card FE port1
and port2 on Local station.

4.2.8.3 Test diagram:

PC/Laptop computer

MGMT Port

Remote Station
NE
NE

L L L L
i i i i
Local Station Remote Station
n n n n
e e e e

FE1 FE2 FE1 FE2

Data Analyzer

4.2.8.4 Recommended Test Analyzer:


Data Analyzer

4.2.8.5 Test procedure:


1. Create two VC12-46v cross-connection from an appropriate 8xFE/T card
to the Line side on local station and remote station;
2. Confirm the traffic can transfer along FE1(local)STM-N
port1(local)STM-N port1(remote)FE1(Remote) FE2(Remote)
STM-N port1(remote) STM-N port1(local)  FE2(local).

66 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

3. Do a packet loss measurement on the Data analyzers and perform a


packet loss measurement with 90MBit/s signal during 12h (Packet length
is 64Byte).

4.2.8.6 Expected Result


No Packet Loss

4.2.8.7 Result Record

Complied Not Complied

4.2.8.8 Estimated Time consumption


13 hours

4.2.9 Packet Loss Test on Ethernet Card (12h, 8xFE/L2)

4.2.9.1 Test Purpose:


This test gives the steps required to measure the line between two terminal
NE’s. The following item will be tested: Packet Loss measurement of line side
(12hours, measured via 8xFE/L2)

4.2.9.2 Test Setup:


Connect Data Analyzer port1 and port2 with hiT 7035 8xFE/L2 card FE port1
and port2 on Local station.

Product code P42022-A5248-H420 © Nokia Siemens Networks 67 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.2.9.3 Test diagram:

PC/Laptop computer

MGMT Port

Remote Station
NE
NE

L L L L
i i i i
Local Station Remote Station
n n n n
e e e e

FE1 FE2 FE1 FE2

Data Analyzer

4.2.9.4 Recommended Test Analyzer:


Data Analyzer

4.2.9.5 Test procedure:


1. Configure 8FE/L2 cards work on DoubleTag mode.
2. Configure LAN1 and LAN2 work on detag mode.
3. Configure WAN1 and WAN2 work on detag mode.
4. Configure both LAN1 and WAN1 with the same PVID such as 11, and
both LAN1 and WAN1 are in the same VLAN list such as 11.
5. Configure both LAN2 and WAN2 with the same PVID such as 22, and
both LAN2 and WAN2 are in the same VLAN list such as 22.
6. Create two VC12-46v cross-connection from WAN1 to CC_LC1 and
WAN2 to CC_LC2 on local station and remote station;
7. Confirm the traffic can transfer along FE1(local)CC_LC1 port(local)
CC_LC1 port(remote)FE1(Remote) FE2(Remote)  CC_LC2
port(remote)  CC_LC1 port(local)  FE2(local).
8. Do a packet loss measurement on the Data analyzers and perform a
packet loss measurement with 90MBit/s signal during 12h (Packet length
is 64Byte).

68 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Fehler! Formatvorlage nicht definiert.

4.2.9.6 Expected Result


No Packet Loss

4.2.9.7 Result Record

Complied Not Complied

4.2.9.8 Estimated Time consumption


13 hours

4.2.10 Packet Loss Test on Ethernet Card (12h, 1xGE/T Card)

4.2.10.1 Test Purpose:


This test gives the steps required to measure the line between two terminal
NE’s. The following item will be tested: Packet Loss measurement of line side
(12hours, measured via 1GE/T)

4.2.10.2 Test Setup:


1. Connect Data Analyzer with hiT 7035 GE card GE port on Local station.
2. Use fiber to loop the GE port on remote station. If necessary.

Product code P42022-A5248-H420 © Nokia Siemens Networks 69 (72)


Issue 2.0
Fehler! Formatvorlage nicht definiert.

4.2.10.3 Test diagram:

PC/Laptop computer

MGMT Port

NE
NE

L L L L
i i i i
Local Station Remote Station
n n n n
e e e e

GE GE

Data Analyzer

4.2.10.4 Recommended Test Analyzer:


Data Analyzer

4.2.10.5 Test procedure:


1. Create a VC4-4v cross-connection from an appropriate 1xGE/T card to
the Line side on local station and remote station;
2. Confirm the traffic can transfer along GE(local)STM-N
port1(local)STM-N port1(remote)GE(local)loopback.
3. Do a packet loss measurement on the Data analyzers and perform a
packet loss measurement with 540MBit/s signal during 12h (Packet
length is 64Byte).

4.2.10.6 Expected Result


No Packet Loss

4.2.10.7 Result Record

 Complied Not Complied

4.2.10.8 Estimated Time consumption


13 hours

70 (72) © Nokia Siemens Networks Product code P42022-A5248-H420


Issue 4.0
Abbreviations

Abbreviations

ACO Alarm Cut Off


Bw7R Style 7R
CD-ROM Compact Disc Read Only Memory
DB Data Base
DC Direct Current
DCC Data Communication Channel
EGB Elektrostatisch Gefährdete Bauteile
EMC Electromagnetic Compatibility
EN European Standard
EOW Engineering Order Wire
ESD Electrostatic Sensitive Device
ETS European Telecommunication Standard
ETSI European Telecommunications Standards Institute
F Standardized interface for connection of a local terminal
FAULT Fault Alarm LED
FO Fiber Optic
GMT Greenwich Mean Time
GND Ground
GUI Graphical User Interface
GUIMN Graphical User Interface Manual
HS Handset
HW Hardware
IEC International Electrotechnical Commission
LCAS Link Capacity Adjustment Scheme
LCT Local Craft Terminal
LED Light Emitting Diode
LWL Lichtwellenleiter (optical fiber)
MSP Multiplex Section Protection
NCT Network Craft Terminal
NUBAT Negative Power Supply Voltage
OK Service LED
OSN Optical Service Node

Product code P42022-A5248-H420 © Nokia Siemens Networks 71 (72)


Issue 2.0
Abbreviations

PDF Portable Document Format


PE Protective Earth (Ground)
PPP Point to Point Protocol
PUBAT Positive Power Supply Voltage
RAM Random Access Memory
Rx Received signal
SDI Serial Debug Interface
SEC SDH Equipment Clock
SELV Separate Extra-Low Voltage
SFP Small Form Factor Pluggable (Module)
SNCP Sub-Network Connection Protection
SW Software
T3 Clock input
T4 Clock output
TIF Telemetry Interface
TNMS Telecommunication Network Management System
Tx Transmitted signal
UMN User Manual
VCDB Variable Configuration Data Block

72 (72) © Nokia Siemens Networks Product code P42022-A5248-H420