You are on page 1of 1

TABEL PERBANDINGAN SPEC TEKNIS

No. Item Spesifikasi UPS Riello MHT 100

1 Jumlah Satu unit Satu unit


Single unit master / An isolation transformer installed on the inverter Master HP/HE UPS feature an output isolation transformer (delta zig/zag type)
2 Jenis/tipe to ensure complete galvanic isolation between DC circuit and load output. on the inverter as part of the inverter circuit inside the UPS cabinet, providing galvanic isolation
between the load and the battery with improved versatility in system configuration

3 Kapasitas Minimum 100 kVA. 100 kVA


4 Daya output Minimum 90 kW. 90 kW
5 Parallel configuration 1+1. 1+1.
6 Input rated voltage 380V 3ph + N. 380 / 400 / 415 V three-phase
7 Input voltage tolerance 342V to 460V. 400 ±20% @ full load
8 Input rate frequency 50/60Hz 45 - 65 Hz
9 Input Power Factor/THDI Minimum 0.99/ maks 2,5% without filter >0.99 / <3%
10 Output rated voltage 3 phase + N : 380V (can be configured 380/480V). 380 / 400 / 415 three-phase + N (selectable)
11 Output voltage tolerance Static load 0,5-1,5% dynamic load in accordance from 0 to 100% static stability ±1%, dynamic stability ±5% in 10 msec
12 Output rated frequency 50/60Hz. 50/60Hz.
13 Output frequency tolerance 0,1 % to 0,3 % 0.05%
14 Total Output Voltage distortion – linear load ThdU< 2% <1%
15 Total Output Voltage Distortion – non linear load ThdU< 4% <3%
16 Overload (mains mode) Up to 150% for 1 minutes, 125% for 10 minutes 150% for 1 min, 125% for 10 min, 110% for 60 min
17 Efficiency online mode @100% of load minimum 93,5% Up to 98%
18 Operating ambient temperatur from 0º C up to 40º C. from 0º C up to 40º C.
19 Relative humidity 0% sd 95%. 5-95% non-condensing
20 Acouctic level at 1 m (ISO 3746) Max 65 dBA. 65 [dBA] (ECO Mode)
21 Dimension W x D x H Maximum 1000 x 8000 x 1930 mm 800 x 850 x 1900
22 Weight 860 kg ±10%. 700kg
23 Degree of protection IP 20. IP 20.
24 Standards safety IEC/EN 62040 -1, AS 62040.1.1,AS62040.1.2 IEC/EN 62040 -1, AS 62040.1.1,AS62040.1.2
25 Standards EMC IEC/EN 62040-2. AS 62040.2 IEC/EN 62040-2. AS 62040.2

26 Comunication Port ModBus Include ModBus Registration Double RS232 + dry contacts + 2 slots for communications interface

27 Backup time 20 Minutes (Load 100KVA) 26,63 Minutes (Load 100KVA)