You are on page 1of 3

GENERAL NOTES AND

EQUIPMENT
SPECIFICATIONS
(Mechanical)
General Notes:

1. Installation of pipes shall be in accordance with PSME code, National Building Code and the Rules and
Regulation of Local Government.

2. Installation of equipment are in accordance with manufacturer’s commendation.

3. Piping for refrigerant lines is copper type and condensate drain pipe schd 40.

4. Insulation provided on suction lines or as required by equipment insulation is flexible unicellular type
wrapped with insulation tape.

5. all pipes shall be properly supported.

7. pipe sizes as per manufacturer’s recommendation.

8. Aluminum cladding is provided to all pipes exposed to weather.

9. Provide drain pipe, drain pipe to the nearest drain line.

AIR CONDITIONING UNITS SCHEDULE

INDOO TYPE NORMA Norm Nomin Pipe Pipe OUT ELECTRICAL REMAR
R UNIT L al al Air size size DOO CHARACTERISTI KS
CALL COOLIN Rating Flow dia. dia. R CS
OUT G Rate (mm (mm UNIT
CAPACIT (CMH) ) ) CALL
Y (kJ/hr) OUT
FCU-01 CASSETT 40000 3 TR 1200 9.52 15.8 ACCU 3.640 Kw, 230 n/a
E TYPE 8 -01 V, 1 Ph, 60 Hz

HYDRAULIC AUTO LIFTER 2 POST CAR LIFT

LIFTING LIFTINGTYPE LIFTING TOTAL WIDTH TOTAL GROSS MOTOR


CAPACITY HEIGHT HEIGHT BET. WIDTH WEIGHT POWER
COLUMNS
4,500 kgs <= 55S 1920 2824 2850 mm 3410 625 kgs 2.2 Kw
mm mm mm (3 HP)