Xperience The Future - Heartbeat - Technology
Heartbeat Technology
04/04/2017
Slide 1 MVS / schd
What’s Heartbeat TechnologyTM?
Heartbeat Monitoring
Heartbeat Diagnostics
High diagnostic coverage Datas
et/
file
Monitoring parameter
Heartbeat Diagnostics
• Permanent process and device diagnostics with high internal diagnosis
• Standardized diagnostic messages with clear guidelines enable an economical maintenance
• Permanent device diagnostics guarantee a safe plant operation with extended proof test
intervals
• By categorizing device info according to NAMUR NE107 the operator get direct information
Slide 6 04/04/2017
Process Instrumentation Training
04/04/2017
Heartbeat Diagnostics
• Low DUλ
• Safe devices 0.1
• Extended PFD
proof test
cycles SIL 1
0.01
SIL 2
0.001
0.0001 SIL 3
SIL 4
6-7 years 9-10 years
* Device 1 with Heartbeat
Device 2 without Heartbeat
Heartbeat Verification
• Heartbeat Technology verifies the correct function of the measuring device according to the
specifications and generates a protocol without process interruption
• The automatic generated protocol supports the documentation requested by internal and external
formalities, laws and standards
Slide 14 / 39 04/04/2017 EG
Heartbeat Verification
• Current check
• Logical program run control
• Check sum RAM
• Temperature check
• Voltage verification
• Clock verification
• …
• The verification can be performed without process interruption
Sensor integrity check
• Verification of internal diagnostics
• Quartz synchronization
• Sensor integrity check - Check of basic functionalities to verify the correct
• Analog path test (self check)
function of the measuring device according to the specifications
• Installation check (device check)
• An automated protocol is generated via DTM (pdf)
• Reference Pulse HF
Dangerous &
Undetectable
Dangerous &
Detectable Safe &
Detectable
SFF [%]
Safe Failure Fraction
Safe &
Undetectable
The λDU value indicates how likely it is that the Safety Instrumented System has a Dangerous Undetected
(DU) failure, resulting in that it cannot perform its intended safety function on demand
λDU
PFDavg
SIL 2
SIL 3
1000 FIT
PFDavg
SIL 2
SIL 3
Heartbeat Monitoring
• Offers additional parameter for predictive maintenance and/ or process optimization
• In addition two wizards for an easy setting of foam- or build-up detection are offered to optimize
the process without expert device knowledge
Lower Limit
Failure
Our of specification
Function check
Maintenance required
This image cannot currently be display ed.
Area of incoupling
dB Level signal
distance
Amplitude in dB
with build-up
1000 mm distance
e.g.
clean antenna AOI = 1000 mm * 49 dB = 49000 mm*dB
With build-up AOI > 49000 mm*dB
60000
threshold for activating
cleaning process