2-1/2" 3-5/8"

3-3/4"
3-1/8"

3-1/4"
2-1/2"

2-1/4" 1/4"
+/- (4 holes)
3-1/8" 3/8" 1/16" 2-1/2"

leads are 12" long recommended cutout:

Electrical Specifications
RED 120V: Input to BLK and BLK/WHT,
COM BLK 580V CT@120mA the BLK / RED wire is not used
RED/YEL RED-R/Y-RED 240V: Input to BLK and BLK/RED,
RED the BLK/WHT wire is not used

GRN unless otherwise stated, all physical dimensions are in inches


120 BLK/WHT GRN/YEL 6.3V CT @ 3A
50/60
part number: TR-PW-12 version: 1.0
Hz GRN desc: Power Transformer, 18W
YEL 0V 5V application:
Power transformer, "laydown" mounting,
240V BLK/RED OR
YEL/WHT for Marshall style 18W amps.
5.0V 6.3V
WHT 6.3V @ 2A date: 24 June 2013
drawn: Robert Hull
sheet: pg 1 of 1