step llowing step by step procedure may be followed for design of two-way simply 7t slabs
Based on the span/overall
depth ratio for shorter span, the overall depth m2v be found. AllOwing a suitable cover (min of 15 mm.) the effective depth maybe assumed. The minimum practical depth of slab is 90 to 100 mm.
Calculate the design load for the slab adopting suitable safety factor
DetermineL ratios the shorter span) and the moment
(where L, is coefficients from Table 7.4 and calculate the moments M and My
Check for depth from M=Kfek b d
for shear stresses. () Calculate maximum shear and check
in both the directions from the corresponding
Calculate the steel required For slabs allowed 3 d or 450 mm. moments. Check for maximum spacing to 200 mm. Ess than 300 mm, limit spacing
span/depth ratio for deflection is based
n) Check for The deflection control. an L and A_t directions. Vin) Check for minimum steel in both cracking for 0r the edge strips. reinforcement on x) Based o Othe support conditions provide