Service Bulletin

Copier B/W
Issued by Canon Europa N.V.
Hardware

Model: Ref No.:


iR5570 iR6570-026
iR6570 (F1-T01-0M5-10067-01)
Date:
February, 2007

Location:
Hopper Assembly
Subject:
Measure against void or blank image
Detail:
<Symptom>
When outputting an image right after supplying Toner in Service Mode (COPIER > FUNCTION > INSTALL >
TONER-S) at the time of installation, void or a blank image sometimes occurs.
<Cause>
When executing TONER-S in Service Mode, the sufficient amount of Toner is not supplied from the Hopper
Assembly [2] to the Developing Assembly [3].

P-1 Toner Supply Diagram

[1] Toner Bottle

[2] Hopper Assembly

[3] Developing Assembly

Servicing work:
In case that the foregoing symptom occurs, re-execute the following Service Mode: COPIER > FUNCTION >
INSTALL > TONER-S.