LABORATORY’S REPORT Nº 3688-18a PG.

1/ 4

LABORATORY’S REPORT

INDÚSTRIAS ARTEB S/A


PHYSICAL LABORATORY ( )
LABORATÓRIO CORPORATIVO CHEMICAL LABORATORY ( )
Av. Piraporinha 1221 – Vila Olga PERFORMANCE LABORATORY ( )
São Bernardo do Campo -SP PHOTOMETRIC LABORATORY (X)
Tel. (11) 4341-9841 Fax (11) 4341-9841
e-mail: laboratorio@arteb.com.br
DENOMINATION: HEADLAMP FORD ECOSPORT H7 CODE / NUMBER: B515 MCA LOW
Note: Commercial name of the models that use this headlamp
design according to: Anexo_3688_Lista de Aplicação.

CUSTOMER: Lumileds Iluminação do Brasil ltda SOLICITED BY: Leonardo Figueiredo


CUSTOMER ADDRESS: Al. Rio Negro, 585 Ed. Jaçari - 4º A Conjunto 44,45 CEP: 06454-000 Barueri - SP – Brazil
SS Nº NUMBER OF SAMPLES: 02 ANALYST: ALEX FONSECA DE OLIVEIRA

BEGIN’S DATE: 22/06/2018 TEMPERATURE: 23,0 ºC HUMIDITY: 60%


EQUIPAMENTOS UTILIZADOS:
PHOTOMETER ILFF 002 - CERTIFICATE: 85.278 / 85.279 /
CALIBRATE: 03/30/2017 - NEXT CALIBRATION: 30/03/2019
POWER SUPPLY ILFF 002/02 - CERTIFICATE: R0674 / 2017
CALIBRATED: 27/03/2017– - NEXT CALIBRATION: 27/03/2019
SPECTRORADIOMETRO EL-10 - CERTIFICATE: L-001-17
CALIBRATE: 09/20/2017 - NEXT CALIBRATION: 20/09/2018
SPECIFICATIONS: ECE R112 / CONTRAN
OBSERVATIONS: Lumileds Ilumination Brasil LTDA are responsible about the control of Anexo_3688_Lista de
Aplicação.
INFORMATION ABOUT LOW BEAM:
VOLTAGE : 13,50 V
PRODUTO: LED-HL [~H7]
PART NUMBER:11972XXX
MARCA: PHILIPS

The results presented in the present Document have restricted significance and they are only applied to the rehearsed sample.
The reproduction of the document for another ends can only be made integrally, without any alteration
Relatório de Ensaio – Rev. C
LABORATORY’S REPORT Nº 3688-18a PG. 2/ 4

COLORIMETRY ECE R112 / CONTRAN 227/07


LOW BEAM / LED COLOUR (WHITE) TEMP: 7400 K
1931 CIE Chromaticity Chart 0,460
0,9

0,8

0,7 0,410

0,6
y coordinate

0,5 0,360

0,4

0,3
0,310

0,2

0,1
0,260
0,0 0,250 0,300 0,350 0,400 0,450 0,500 0,550
0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8
x coordinate

Limit the Green y = 0.150 + 0.640 x X: 0,315


Standardization Limit with the Green-Yellowish y = 0.440 Y: 0,327
Limit with Yellow x = 0.500 Z: 0,358
Limit with Purpura-Reddish y = 0.382
Limit with Purpura-Reddish y = 0.050 + 0.750 x
Limit with Blue x = 0.310

RESULT: APPROVED The point must be within the approved area.

The results presented in the present Document have restricted significance and they are only applied to the rehearsed sample.
The reproduction of the document for another ends can only be made integrally, without any alteration
Relatório de Ensaio – Rev. C
LABORATORY’S REPORT Nº 3688-18a PG. 3/ 4

LOW BEAM
Specification: ECE R112 / CONTRAN 227/07 Measurement Distance:25 m
Photometric Values in Cd
INITIAL SAMPLE VALUES VALUES
POINTS
MIN. MAX. SAMPLE LH SAMPLE RH
LOW BEAM
8L/4U 190 ----- 98,0 118,8
V /4U (sum of this points) ----- 100,0 105,4
8R/4U ----- 113,2 135,0
4R/2U 375 ----- 125,0 151,2
V /2U (sum of this points) ----- 148,0 176,2
4L/2U ----- 138,0 143,4
8L/H 65 ----- 431,6 433,2
4L/ H 125 ----- 505,6 530,1
H/V ----- 625 606,0 608,6
B50L ----- 350 198,8 221,2
BR ----- 1750 130,0 166,1
75R 10100 ----- 10481 10278,1
75L ----- 10600 4643,8 4950,3
50L ----- 13200 11321,0 11172,4
50R 10100 ----- 22695,0 22249,7
50V 5100 ----- 22387,0 22024,9
25L 1700 ----- 12678,0 12453,0
25R 1700 ----- 4370,0 4284,2
ZONE III ----- 625 607,0 606,8
ZONE IV 2500 ----- 7712,10 7607,8
ZONE I ----- (50R*2) 40435,0 39838,0
RESULT: Approved Approved

The results presented in the present Document have restricted significance and they are only applied to the rehearsed sample.
The reproduction of the document for another ends can only be made integrally, without any alteration
Relatório de Ensaio – Rev. C
LABORATORY’S REPORT Nº 3688-18a PG. 4/ 4

Projection LOW BEAM

ISOLUX Wall View Low Beam

EXIT DATE: 11/07/2018


ANALYST: SUPERVISION: COPIES DISTRIBUTION:
ALEX FONSECA DE OLIVEIRA JARBAS ENZENBERG Leonardo Figueiredo
MÁRCIO CLAUDINO

The results presented in the present Document have restricted significance and they are only applied to the rehearsed sample.
The reproduction of the document for another ends can only be made integrally, without any alteration
Relatório de Ensaio – Rev. C
ANEXO - LABORATORY’S REPORT Nº 3688-18

Lista de marca/modelos/versão/ano equipadas com farol utilizado no ensaio Nº 3688-18

Ford EcoSport FreeStyle 1.5 12V câmbio automárico 6 marchas Flex >2018
Ford EcoSport FreeStyle 1.5 12V câmbio manual Flex >2018
Ford EcoSport SE 1.5 16V câmbio automático 6 marchas Flex >2018
Ford EcoSport SE 1.5 16V câmbio manual Flex >2018
Ford EcoSport Titanium 2.0 16V câmbio automático 6 marchas Flex >2018

Versão: 0 Atualização: Ago/2018 Resp: Lumileds Iluminação Brasil ltda