RUBIN Sonic

Network smart water meter

Application
RUBIN Sonic ultrasonic bulk meter is designed
for cold water networks for the utility market and
smart metering applications. Based on a unique sensor technology, a direct ultrasonic measurement provides
superior stability of the measurement over time for accurate billing and monitoring of the water consumption
at a minimum pressure drop.

FEATURES BENEFITS
› Low pressure drop › Design for robustness to dirt
› Robust housing with flange interface › Very high resistance for harsh environment
› Performances: R 500 / Class 2 › Highly stable ultrasonic measurement
› DN 50 to DN 200 › Reduction of non-revenue water losses
› Battery Powered › Real time data remote reading for easy billing
› Pulse communication/Sigfox and grid monitoring
› IP68 › Powerful data & events logger
› ACS, WRAS, Belgaqua, MID approvals › Leakage detection

V1.0 -04022021
RUBIN Sonic

› Ultrasonic technology
› Measuring range according to OIML R49
› Ratio R500
› Metrololgical class: 2
› Vertical/horizontal installation
› U0D0
› Cast iron body with flange connection
› Nominal pressure 16 bar
› Environmental temperature up to 70°C
› Medium temperature class (EN ISO 4064): T50
› Battery power supply

mm 50 65 80 100 125 150 200


Nominal diameter DN
Inches 2 2 1/2 3 4 5 6 8
Flow on overload Q4 m3/h 50 78,75 78,75 125 200 313 500
Continuous flow Q3 m3/h 40 63 63 100 150 250 400
Transitional flow rate Q2 m3/h 0.13 0.2 0.2 0.32 0.5 0.8 1.28
Min. flow Q1 m3/h 0.08 0.13 0.13 0.2 0.3 0.5 0.8
Starting flow at approx. m3/h 0.04 0.065 0.065 0.1 0.15 0.25 0.4
Max. pressure drop bar 0.16 0.16 0.16 0.16 0.16 0.16 0.16
at Q3
Measuring range R500
ISO ISO ISO ISO ISO
Flange standard ANSI ISO ANSI ANSI ISO ANSI PN16/
BSI BSI BSI BSI 10
Weight without
ca. kg 10 12 13 15 18 25 36
connections
Dimensions Total
length 200 200 225 250 250 300 350
(L)
Height
97 103 108 115 127 134 152
(H1)
Total
Height 182 198,5 215,5 233,5 259,5 275,5 312
(H)
Width
165 185 200 220 240 260 340
(W)
Housing
length 110 110 110 110 110 110 110
(L1)
Displayed values Net or Positive volume, reverse volume, flow rate, events/alarms, firmware
Water detection (dry, wet),reverse flow, leakage,low battery,air bubbles,
Events/alarms overload, frost, heat, over temperature, no consumption, defective meter,
software error
Mode User, test, sleep
Programming, testing,
NFC using ParamAPP (android app)
configuration interface
Data logger 24 hours, 460 days, 48 months, 16 years
Date/time, event flags, net volume, reverse volume,min flow rate, max flow
Recorded data rate,average water temperature, min and max water temp, average ambient
temp, min and max ambient temp
Approvals MID, ACS, WRAS, BELGAQUA, CE

2 V1.0 -04022021
Pressure loss curves

Mesurement error limits and metrological class 2


According to OIML guideline R 49

Reference conditions: Process medium = Water, Temperature = 20 °C

Q1<Q<Q2 lower measuring range

Q2<Q<Q4 upper measuring range

3 V1.0 -04022021
RUBIN Sonic Open Collector
Pulse length 30 up to 500 ms
Pulse weight 1 to 1000 L
Max pulse frequency 25 Hz
Pulse output configuration Single (pulse, direction), double (double positive pulse)
Battery lifetime 16 years (standard configuration)

Catalogue reference

Description Flange standard Part number


ISO PN16 YFMR-050-A1F-OC-INTGXX
RUBIN Sonic DN50 OC ANSI 150 YFMR-050-A1A-OC-INTGXX
BSI 10 YFMR-050-A1B-OC-INTGXX
RUBIN Sonic DN65 OC ISO PN16 YFMR-065-A1F-OC-INTGXX
ISO PN16 YFMR-080-A1F-OC-INTGXX
RUBIN Sonic DN80 OC ANSI 150 YFMR-080-A1A-OC-INTGXX
BSI 10 YFMR-080-A1B-OC-INTGXX
ISO PN16 YFMR-100-A1F-OC-INTGXX
RUBIN Sonic DN100 OC ANSI 150 YFMR-100-A1A-OC-INTGXX
BSI 10 YFMR-100-A1B-OC-INTGXX
RUBIN Sonic DN125 OC ISO PN16 YFMR-125-A1F-OC-INTGXX
ISO PN16 YFMR-150-A1F-OC-INTGXX
RUBIN Sonic DN150 OC ANSI 150 YFMR-150-A1A-OC-INTGXX
BSI 10 YFMR-150-A1B-OC-INTGXX
ISO PN10 YFMR-200-A1L-OC-INTGXX
RUBIN Sonic DN200 OC
ISO PN16 YFMR-200-A1F-OC-INTGXX

Standard configuration

INTG01: Pulse length 30ms / Pulse weight 100L / Net Index / 2 decimal digits on display

INTG02: Pulse length 30ms / Pulse weight 1L up to DN125, 100L for DN125, 150, 200/ Net Index / 3 decimal
digits on display

INTG03: Double positive pulses output: Pulse length 30ms / Pulse weight 100L / Positive Index / 2 decimal
digits on display

4 V1.0 -04022021
RUBIN Sonic Sigfox/Open collector
Frequency 868.95 MHz
Transmissions Two per day: 6:00 a.m. & 6:00 p.m. UTC
Readout interval Permanent
Radio Class U0
Sigfox
ID 8 bits
Positive volume, flow time, battery voltage, ambient
Telegram content
temperature, Events/alarms (Air bubbles,Leak, Frost,Heat,Over
by default
temperature, No consumption, Reverse flow), ID
Pulse length 30 up to 500 ms
Open
Pulse weight 1 to 1000 L
Collector
Max pulse frequency 25 Hz
Battery lifetime 16 years (standard configuration)

Catalogue reference

Description Flange standard Part number


ISO PN16 YFMR-050-A1F-OCS-INTGXX
RUBIN Sonic DN50 OCS ANSI 150 YFMR-050-A1A-OCS-INTGXX
BSI 10 YFMR-050-A1B-OCS-INTGXX
RUBIN Sonic DN65 OCS ISO PN16 YFMR-065-A1F-OCS-INTGXX
ISO PN16 YFMR-080-A1F-OCS-INTGXX
RUBIN Sonic DN80 OCS ANSI 150 YFMR-080-A1A-OCS-INTGXX
BSI 10 YFMR-080-A1B-OCS-INTGXX
ISO PN16 YFMR-100-A1F-OCS-INTGXX
RUBIN Sonic DN100 OCS ANSI 150 YFMR-100-A1A-OCS-INTGXX
BSI 10 YFMR-100-A1B-OCS-INTGXX
RUBIN Sonic DN125 OCS ISO PN16 YFMR-125-A1F-OCS-INTGXX
ISO PN16 YFMR-150-A1F-OCS-INTGXX
RUBIN Sonic DN150 OCS ANSI 150 YFMR-150-A1A-OCS-INTGXX
BSI 10 YFMR-150-A1B-OCS-INTGXX
ISO PN10 YFMR-200-A1L-OCS-INTGXX
RUBIN Sonic DN200 OCS
ISO PN16 YFMR-200-A1F-OCS-INTGXX

Standard configuration

INTG01: Pulse length 30ms / Pulse weight 100L / Positive Index / 2 decimal digits on display

INTG02: Pulse length 30ms / Pulse weight 1L up to DN125, 100L for DN125, 150, 200/ Net Index / 3 decimal
digits on display

INTG03: Double positive pulses output: Pulse length 30ms / Pulse weight 100L / Positive Index / 2 decimal
digits on display

5 V1.0 -04022021
Rubin LoRa 868 MHz
Standard LORAWAN
Connection mode Over-The-Air Activation OTAA/ Activation by Personalization ABP
Frequency 868.95 MHz
Battery lifetime 16 years
Transmission interval Twice a day (6.00 and 18.00 UTC)
Readout interval Permanent
Emitted Power 25 mW (14 dBm)
Radio Range 2 km (depending on the ambient condition)
Address 16 digits
Positive volume, reverse volume, medium temperature,
Telegram content by default
events/alarms, remaining battery lifetime

Catalogue reference

Description Flange standard Part number


ISO PN16 YFMR-050-A1F-LW-INTGXX
RUBIN Sonic DN50 LW8 ANSI 150 YFMR-050-A1A-LW-INTGXX
BSI 10 YFMR-050-A1B-LW-INTGXX
RUBIN Sonic DN65 LW8 ISO PN16 YFMR-065-A1F-LW-INTGXX
ISO PN16 YFMR-080-A1F-LW-INTGXX
RUBIN Sonic DN80 LW8 ANSI 150 YFMR-080-A1A-LW-INTGXX
BSI 10 YFMR-080-A1B-LW-INTGXX
ISO PN16 YFMR-100-A1F-LW-INTGXX
RUBIN Sonic DN100 LW8 ANSI 150 YFMR-100-A1A-LW-INTGXX
BSI 10 YFMR-100-A1B-LW-INTGXX
RUBIN Sonic DN125 LW8 ISO PN16 YFMR-125-A1F-LW-INTGXX
ISO PN16 YFMR-150-A1F-LW-INTGXX
RUBIN Sonic DN150 LW8 ANSI 150 YFMR-150-A1A-LW-INTGXX
BSI 10 YFMR-150-A1B-LW-INTGXX
ISO PN10 YFMR-200-A1L-LW-INTGXX
RUBIN Sonic DN200 LW8
ISO PN16 YFMR-200-A1F-LW-INTGXX

Standard configuration

INTG01: Pulse length 30ms / Pulse weight 100L / Positive Index / 2 decimal digits on display

INTG02: Pulse length 30ms / Pulse weight 1L up to DN125, 100L for DN125, 150, 200/ Net Index / 3 decimal
digits on display

INTG03: Double positive pulses output: Pulse length 30ms / Pulse weight 100L / Positive Index / 2 decimal
digits on display

6 V1.0 -04022021
A closer look to multi-protocol principle

Device can communicate either over OMS V4 (OMS V3 compatibility)/EN13757 or over LoraWAN protocol

In the default configuration, on first water detection, the meter will start broadcasting WMBUS T1 frames
every 96 seconds.

Wireless WMBUS frames can be retrieved by a fixed infrastructure, or via walk or drive by systems. In open
field, this protocol can achieve a communication range of 2km. The WMBUS communication in T1 mode is
unidirectional, messages are broadcasted in the air and captured by a receiver if any with no impact on the
meter behaviour.

In normal WMBUS operations, the meter will try once per day (default setting) to connect to a LoraWAN
network. In that case the protocol used is bi-directional, which means the meter will get a feedback if the
LoraWAN network has accepted the connection, in this time we talk of “join accept”.

A “join accept” can occurs only if the device has been registered by an user into an application attached to
the LoraWAN network. Such a registration can be done only by the owner of the device and is secured by
two 128 bits unique keys.

If such a “join accept” is achieved, the meter will switch into LoraWAN mode: it will stop broadcasting
WMBUS T1 frames and will send Lora uplinks 2 times per day, at 6 AM and 6 PM UTC (default
configuration). LoraWAN modulation and protocol allow ranges up to 20 km, mainly on fixed networks.

If for any reason (device unregister from network, network down…) the communication to the LoraWAN
network is lost by the device, it will automatically switch back to default configuration : broadcast
WMBUST1 frames every 96 seconds and try to re-join a LoraWAN network once per day.

7 V1.0 -04022021
Rubin LoRa WM-Bus 868 MHz
Frequency 868.95 MHz
Battery lifetime 16 years

Default protocol
Mbus Standard OMS V4 (OMS V3 compliant)/ EN13757
Transmission mode T1 (unidirectional)
Transmission interval 96 seconds by default (configurable for drive-by or walk-by)
Readout interval Permanent
Emitted Power 25 mW (14 dBm)
Radio Range 2 km (depending on the ambient condition)
WMBus address 8 digits
Encryption mode Mode 5 (AES 128 bits)
Positive volume, reverse volume, medium temperature, date/time,
Telegram content by default target monthly value, target date, events/alarms, remaining
battery lifetime

Secondary protocol*
Standard LORAWAN
Connection mode Over-The-Air Activation OTAA/ Activation by Personalization ABP
Transmission interval Twice a day (6.00 and 18.00 UTC)
Readout interval Permanent
Emitted Power 25 mW (14 dBm)
Radio Range 2 km (depending on the ambient condition)
Address 16 digits
Positive volume, reverse volume, medium temperature,
Telegram content by default
events/alarms, remaining battery lifetime
*WM-bus communication by default. Switch to LORAWAN communication automatically if the
connection is established

Catalogue reference

Description Flange standard Part number


ISO PN16 YFMR-050-A1F-LW8-INTGXX
RUBIN Sonic DN50 LW8 ANSI 150 YFMR-050-A1A-LW8-INTGXX
BSI 10 YFMR-050-A1B-LW8-INTGXX
RUBIN Sonic DN65 LW8 ISO PN16 YFMR-065-A1F-LW8-INTGXX
ISO PN16 YFMR-080-A1F-LW8-INTGXX
RUBIN Sonic DN80 LW8 ANSI 150 YFMR-080-A1A-LW8-INTGXX
BSI 10 YFMR-080-A1B-LW8-INTGXX
ISO PN16 YFMR-100-A1F-LW8-INTGXX
RUBIN Sonic DN100 LW8 ANSI 150 YFMR-100-A1A-LW8-INTGXX
BSI 10 YFMR-100-A1B-LW8-INTGXX
RUBIN Sonic DN125 LW8 ISO PN16 YFMR-125-A1F-LW8-INTGXX
ISO PN16 YFMR-150-A1F-LW8-INTGXX
RUBIN Sonic DN150 LW8 ANSI 150 YFMR-150-A1A-LW8-INTGXX
BSI 10 YFMR-150-A1B-LW8-INTGXX

8 V1.0 -04022021
ISO PN10 YFMR-200-A1L-LW8-INTGXX
RUBIN Sonic DN200 LW8
ISO PN16 YFMR-200-A1F-LW8-INTGXX

Standard configuration

INTG01: Pulse length 30ms / Pulse weight 100L / Positive Index / 2 decimal digits on display

INTG02: Pulse length 30ms / Pulse weight 1L up to DN125, 100L for DN125, 150, 200/ Net Index / 3 decimal
digits on display

INTG03: Double positive pulses output: Pulse length 30ms / Pulse weight 100L / Positive Index / 2 decimal
digits on display

9 V1.0 -04022021
Rubin Sonic Wired M-Bus
M-Bus Standard OMS V4 (OMS V3 compatibility)/EN13757
Secondary Address 8 digits
Positive volume, reverse volume, medium temperature, date/time,
Telegram content by default target monthly value, target date, events/alarms, remaining
battery lifetime
Baud rate 2400 bps (configurable)
Wiring White/Brown
Battery lifetime 16 years

Description Flange standard Part number


ISO PN16 YFMR-050-A1F-MB-INTGXX
RUBIN Sonic DN50 MB ANSI 150 YFMR-050-A1A-MB-INTGXX
BSI 10 YFMR-050-A1B-MB-INTGXX
RUBIN Sonic DN65 MB ISO PN16 YFMR-065-A1F-MB-INTGXX
ISO PN16 YFMR-080-A1F-MB-INTGXX
RUBIN Sonic DN80 MB ANSI 150 YFMR-080-A1A-MB-INTGXX
BSI 10 YFMR-080-A1B-MB-INTGXX
ISO PN16 YFMR-100-A1F-MB-INTGXX
RUBIN Sonic DN100 MB ANSI 150 YFMR-100-A1A-MB-INTGXX
BSI 10 YFMR-100-A1B-MB-INTGXX
RUBIN Sonic DN125 MB ISO PN16 YFMR-125-A1F-MB-INTGXX
ISO PN16 YFMR-150-A1F-MB-INTGXX
RUBIN Sonic DN150 MB ANSI 150 YFMR-150-A1A-MB-INTGXX
BSI 10 YFMR-150-A1B-MB-INTGXX
ISO PN10 YFMR-200-A1L-MB-INTGXX
RUBIN Sonic DN200 MB
ISO PN16 YFMR-200-A1F-MB-INTGXX

Standard configuration

INTG01: Pulse length 30ms / Pulse weight 100L / Positive Index / 2 decimal digits on display

INTG02: Pulse length 30ms / Pulse weight 1L up to DN125, 100L for DN125, 150, 200/ Net Index / 3 decimal
digits on display

INTG03: Double positive pulses output: Pulse length 30ms / Pulse weight 100L / Positive Index / 2 decimal
digits on display

10 V1.0 -04022021
Accessories

Cable

Description Part number


Female angled M12 length 5m AAC-00-A2

Female angled M12 length 10m AAC-00-A3


Female angled M12 length 25m AAC-00-A4

Configurator
Description Part number
Verified smartphone with installed ACC-PARAMAPP-DEVICE
ParamAPP user licence

ParamAPP user licence ACC-PARAMAPP-LIC

Certificate

Description Part number


Certificate standard Q1, Q2, Q3 CERT_STD
Certificate – Raw data (table) CERT_RAW

Certificate – Additional point CERT_ADD_POINT