This catalog provides a comprehensive overview of our critical care portfolio. The portfolio consists of
tools for monitoring patients of varying clinical complexity. Each product and system employs advanced
technologies to provide optimum insight and maximum efficiency within the clinical workflow.
Edwards also offers educational tools and resources to help advance the care and treatment of the
critically ill. Please visit www.Edwards.com/Education to access these complimentary tools, including
the Quick Guide to Cardiopulmonary Care.
Table of Contents
FloTrac sensor is a less-invasive hemodynamic monitoring device that provides key flow parameters
(CO, SV, SVV, SVR) from an existing arterial catheter using continuous automatic tone adjustments.
The complete system includes the Vigileo monitor that calculates and displays the key flow parameters.
• Requires no additional catheters, boluses or chemical indicators enabling rapid set up.
• Continuously monitors changes in the patient’s vascular tone (compliance and resistance).
• Validated against the clinical gold standard Swan-Ganz pulmonary artery catheter1.
Model Description
1. A Manecke G, Auger W. “Cardiac Output Determination from the Arterial Pressure Wave: Clinical Testing of a Novel Algorithm That Does Not Require
Calibration.” Journal of Cardiothoracic and Vascular Anesthesia 2007; Vol 21 (1): 3-7
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
1
Advanced Minimally Invasive
Hemodynamic Monitoring
PreSep oximetry catheters are triple lumen central venous catheters with the added capability for continuously
monitoring central venous oxygen saturation (ScvO2). It is integral to Early Goal-Directed Therapy (EGDT)
for the management of sepsis. EGDT when used with the PreSep catheter yields significant reductions in
sepsis-related mortality1.
• Continuous ScvO2 monitoring to assess the balance of oxygen delivery and consumption.
Proximal Lumen
Sheath
Distal Lumen
Optical Module
Connector
Suture Ring
Suture Wings
Medial Lumen
Integrated Antimicrobial
Model Description Protection* Size (F) # Lumens Length (cm)
1. Rivers EP et al. Early Goal-Directed Therapy in the Treatment of Severe Sepsis and Septic Shock. New England Journal of Medicine 2001; 345 (19):1368-77
* PreSep Oligon oximetry catheters contain an integrated Oligon antimicrobial material. The activity of the antimicrobial material is localized at the catheter
surfaces and is not intended for treatment of systemic infections. In vitro testing demonstrated that the Oligon material provided broad-spectrum effectiveness
(≥ 3 log reduction from initial concentration within 48 hours) against the organisms tested: Staphylococcus aureus, Staphylococcus epidermidis, Klebsiella
pneumoniae, Enterococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, Acinetobacter calcoaceticus, Corynebacterium diphtheriae,
Enterobacter aerogenes, GMRSa, Pseudomonas aeruginosa, Candida glabrata and VRE (Enterococcus faecium).
** All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
All model numbers with “CDC” contain ChloraPrep retractable safety scalpel, needle locking devices and double sterile barrier with CSR wrap.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
2
Advanced Minimally Invasive
Hemodynamic Monitoring
PediaSat Oximetry Catheters
PediaSat oximetry catheters are pediatric central venous catheters with the added capability for
continuously monitoring central venous oxygen saturation (ScvO2).
• Continuously monitors ScvO2 to assess the balance of oxygen delivery and consumption.
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
3
Advanced Minimally Invasive
Hemodynamic Monitoring
Vigileo Monitor
Vigileo monitor is a single monitor solution for fluid optimization and tissue oxygenation. It allows for
the continuous monitoring of essential hemodynamic information, providing rapid insight on a minimally
invasive, easy-to-use platform.
• The FloTrac sensor to measure and display key flow parameters (CO, SV, SVV, SVR).
TM
ScvO2
74
CO ScvO2
12 100
6 50
?
0 0
TM
Vigileo
Vi gileo
Model Description
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
4
Advanced Hemodynamic Monitoring
Swan-Ganz continuous cardiac output, SvO2 and CEDV catheters are to be used with the Vigilance II monitor
to properly display the specified parameters. Swan-Ganz CCO catheters allow for continuous calculation
of cardiac output.
Thermal Filament
PA Distal
Connector
Lumen
Hemodynamic Monitoring
Model Description Size (F) Unit of Measure Length (cm)
139F75 Continuous cardiac output (CCO) VIP catheter 7.5 CS (5) 110
Advanced
139HF75P Continuous cardiac output (CCO) VIP catheter* 7.5 CS (5) 110
Swan-Ganz CCOmbo catheters are the abbreviated name for Swan-Ganz CCO/SvO2 thermodilution catheters,
which are designed to continuously monitor both cardiac output and mixed venous oxygen saturation (SvO2).
Swan-Ganz CCOmbo V catheters are designed to enable continuous monitoring of hemodynamic pressures,
continuous cardiac output, mixed venous oxygen saturation (SvO2), and continuous end diastolic volume (EDV).
774F75 Continuous cardiac output catheter with SvO2 and EDV 7.5 EA 110
774HF75 Continuous cardiac output catheter with SvO2 and EDV* 7.5 EA 110
777F8 Continuous cardiac output VIP catheter with SvO2 and EDV 8 EA 110
777HF8 Continuous cardiac output VIP catheter with SvO2 and EDV* 8 EA 110
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
5
Swan-Ganz Oximetry Thermodilution Catheters
Swan-Ganz oximetry thermodilution catheters continuously monitor mixed venous oxygen saturation.
• Swan-Ganz VIP oximetry thermodilution catheters provide an additional (VIP) lumen that
allows for continuous infusion.
• Swan-Ganz Paceport oximetry thermodilution catheters are intended for use in patients who
require hemodynamic monitoring when temporary transvenous pacing is anticipated.
Thermistor
Thermistor Connector
Distal Lumen
Distal Lumen RV Port @ 19 cm
Hub
Proximal Injectate
Advanced
Port @ 30 cm
Proximal Injectate
Lumen Hub
RV Paceport
Lumen Hub
(Pacing/Infusion)
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
6
Swan-Ganz Thermodilution Pacing Catheters
Swan-Ganz thermodilution pacing catheters are indicated for atrial, ventricular, or A-V sequential pacing.
• Thermodilution pacing catheters contain three atrial and two ventricular electrodes for atrial
and ventricular pacing and atrioventricular (A-V) sequential pacing.
Swan-Ganz Paceport catheters are intended for use in patients who require hemodynamic monitoring
Hemodynamic Monitoring
when the need for temporary transvenous pacing is anticipated.
Advanced
Thermistor Connector
Balloon Inflation Valve
PA Distal Lumen
Paceport Catheter
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
7
Swan-Ganz Bipolar Pacing Catheters
Swan-Ganz bipolar pacing catheters are designed for temporary right ventricular endocardial pacing.
Balloon
Proximal
Electrode Distal Electrode
Connector
Proximal Electrode
Gate Valve
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
8
Swan-Ganz Thermodilution Catheters
The Swan-Ganz thermodilution catheters are designed for a variety of hemodynamic applications.
Hemodynamic Monitoring
• The Swan-Ganz VIP catheters have an extra lumen in addition to the standard distal and injectate
lumens to provide direct access to the right atrium.
Advanced
• The Swan-Ganz VIP+ catheters are equipped with two right atrium lumens.
PA Distal
Lumen Hub
RV Infusion
Balloon Inflation Port @ 19 cm
Valve (Gate Valve) RA Infusion
RV Infusion Lumen Hub Port @ 31 cm
Thermistor
Connector
Thermistor
Proximal Injectate Proximal Injectate
RA Infusion Lumen Lumen Hub Port @ 30 cm
Balloon
PA Distal
Lumen
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
9
Swan-Ganz No Latex Catheter and Introducer
• Catheter and introducer sheath are packaged together for maximum convenience.
• ControlCath thermodilution catheters are made from a proprietary polymer blend and offer improved
torque control and maneuverability over the standard Swan-Ganz thermodilution catheter.
• The Swan-Ganz ControlCath synthetic thermodilution catheter “C-Tip” allows for both femoral
or SVC approaches.
Thermistor
Balloon Inflation Valve
Proximal Injectate
Proxi
Port
Port @ @ 30 cm
Hemodynamic Monitoring
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
10
Swan-Ganz Femoral Vein Insertion Catheters
• Swan-Ganz Hi-Shore thermodilution catheters are slightly stiffer than the standard Swan-Ganz
catheter, and may be used when more torque control and maneuverability is needed.
• Swan-Ganz CardioCath thermodilution catheters are made of the same material as the Hi-Shore
catheters, but are even stiffer due to the stiffening rod in one lumen.
• Swan-Ganz ControlCath thermodilution catheters are made from a proprietary polymer blend
and offer improved torque control and maneuverability.
Hemodynamic Monitoring
Balloon
Advanced
Balloon Inflation Valve
Proximal Injectate Distal Lumen Port
Port @ 30 cm
“S-Tip”
Thermistor
Proximal Injectate
Port @ 30 cm
Balloon
“C-Tip” Distal Lumen Port
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
11
Swan-Ganz Pulmonary Angiography Catheters
Swan-Ganz pulmonary angiography catheters are indicated for the detection of emboli in the
pulmonary vasculature.
• The distal tip is closed-ended to optimize injection of contrast medium through the
multi-hole side exit ports, which minimizes the occurrence of arrhythmias, intramyocardial
staining, and catheter tip recoil.
Balloon
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
12
Swan-Ganz Monitoring Catheters
Swan-Ganz flow-directed monitoring catheters provide a rapid, simple, and effective method for
monitoring right heart pressures.
• In double lumen catheters, the lumen terminates at the distal tip of the catheter and is
used to monitor pulmonary artery and wedge pressures.
• Triple lumen monitoring catheters have the same capabilities as double lumen catheters
with the additional (proximal) lumen for central venous pressure monitoring.
Hemodynamic Monitoring
Triple Lumen Monitoring Catheter
Advanced
Model Description Size (F) Unit of Measure Length (cm)
110F5 Double lumen catheter 5 CS (5) 110
123F6P Double lumen catheter 6 CS (5) 110
T123F6 Double lumen catheter, “T-Tip” 6 CS (5) 110
111F7P Double lumen catheter 7 CS (5) 110
S111F7 Double lumen catheter, “S-Tip” bend 7 EA 110
T111F7 Double lumen Hi-Shore catheter, “T-Tip” 7 CS (5) 110
114F7P Triple lumen catheter, 30 cm exit proximal lumen 7 CS (5) 110
115F7P Triple lumen catheter, 20 cm exit proximal lumen 7 CS (5) 110
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
13
CO-Set+ Closed Injectate Delivery System
The CO-Set+ closed injectate delivery system works effectively with room temperature or cold injectate.
• Provides simple and convenient delivery of injectate for the measurement of cardiac
output by thermodilution.
Cooling Container
Hemodynamic Monitoring
10 cc Syringe
Advanced
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
14
IntroFlex Percutaneous Sheath Introducers
IntroFlex introducers are the perfect companion for your Swan-Ganz catheters.
• Sheath material resists kinking and sheath collapse, while easing insertion.
Catheter
Sideport
Distal Locking Adapter
Contamination Shield
Hemodynamic Monitoring
5 French Introducers
Advanced
Model Description Unit of Measure Useable Length (cm)
6 French Introducers
7 French Introducers
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
15
8 French Introducers
Model Description Unit of Measure Useable Length (cm)
I550BF8 Kit with 8F sheath and bonded adjustable valve CS (10) 10
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
16
Vigilance II Monitor
• CO, SvO2, EDV, RVEF, SVR and SV parameters are continuously displayed on a single,
easy-to-use unit.
• Service and extended warranties are available for the Vigilance II monitor. For more information
please speak with an Edwards sales representative or call 800-822-9837.
Comprehensive Hemodynamic
TM
Monitoring
min
Model Description
VIG2 Continuous cardiac output computer system with SvO2 and CEDV capabilities
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
17
Pressure Monitoring and Closed Blood Sampling Systems
The pressure monitoring kit with the TruWave disposable pressure transducer is a sterile, single-use
kit that monitors blood pressure when attached to pressure monitoring catheters.
Snap-Tab Device
To
IV Set
Transducer Vent Port
PX600 TruWave disposable pressure transducer, one bonded 1-way shutoff stopcock CS (20)
PX600F TruWave disposable pressure transducer, 3 ml/hr flush device, vent stopcock CS (20)
PX600F30 TruWave disposable pressure transducer, 30 ml/hr flush device, vent stopcock CS (20)
PX600I TruWave disposable pressure transducer, bonded 1-way shutoff stopcock, CS (20)
bonded 3-way vent stopcock
PX601 TruWave disposable pressure transducer, 12” cable CS (20)
PX604 TruWave disposable pressure transducer, 4’ cable CS (20)
PX604I TruWave disposable pressure transducer, 4’ cable, bonded CS (10)
1-way shutoff stopcock, bonded 3-way vent stopcock
Closed Blood Sampling Systems
Pressure Monitoring and
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
18
TruWave Disposable Pressure Transducer Kits
PX212 Model PX600F disposable pressure transducer, flush device, IV set CS (10)
(macrodrip), 12” pressure tubing, one 3-way stopcock
PX260 Model PX600F disposable pressure transducer, flush device, CS (10)
IV set (macrodrip), 48” and 12” pressure tubing, two 3-way stopcocks
PX272 Model PX600F disposable pressure transducer, flush device, IV set CS (10)
(macrodrip), 60” and 12” pressure tubing, two 3-way stopcocks
PX284 Model PX600F disposable pressure transducer, flush device, IV set CS (10)
(macrodrip), 72” and 12” pressure tubing, two 3-way stopcocks
PX1X2 Model PX600F disposable pressure transducer, two flush devices, CS (10)
bifurcated IV set (macrodrip), two sets of 48” and 12” pressure tubing,
three 3-way stopcocks, one 4-way stopcock
PX2X2 Model PX600F disposable pressure transducer, two flush devices, CS (10)
bifurcated IV set (macrodrip), two sets of 48” and 12” pressure
tubing, four 3-way stopcocks
PX2X3 Two model PX600F disposable pressure transducers, three flush CS (10)
devices, trifurcated IV set (macrodrip), three sets of 48” and 12”
pressure tubing, five 3-way stopcocks, one 4-way stopcock
PX3X3 Three model PX600F disposable pressure transducers, three flush devices, CS (10)
trifurcated IV set (macrodrip), three sets of 48” and 12” pressure tubing,
six 3-way stopcocks
PX3X3272 Three model PX600F disposable pressure transducers, three flush devices, CS (10)
trifurcated IV set (macrodrip), three sets of 60” and 12” pressure tubing,
six 3-way stopcocks
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
19
VAMP Closed Blood Sampling System
Venous Arterial blood Management Protection system is a needleless closed blood sampling system.
• When attached to pressure monitoring lines, the VAMP system provides a safe and convenient
method for the withdrawal of blood samples.
• Designed for use with all disposable pressure transducers and for connection to central line
catheters and arterial catheters.
Proximal
Reservoir
(To Patient) Distal
Sampling Shut Off Valve
Site
VMP106 6” sampling kit, sample site, reservoir and two shut-off valves (may CS (20)
be used for venous applications without a flow controlling device)
48VMP120 20” sampling kit, sample site and arm reservoir CS (20)
48VMP160 60” sampling kit, sample site and arm reservoir CS (20)
48VMP172 72” sampling kit, sample site and arm reservoir CS (20)
48VMP184 84” sampling kit, sample site and arm reservoir CS (20)
Closed Blood Sampling Systems
48VMP260 60” sampling kit, sample site and pole-mount reservoir CS (20)
Pressure Monitoring and
48VMP272 72” sampling kit, sample site and pole-mount reservoir CS (20)
48VMP284 84” sampling kit, sample site and pole-mount reservoir CS (20)
48AVMP VAMP system anesthesia kit, 68” sampling kit with male/female connector CS (20)
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
20
VAMP Plus System Kits
Venous Arterial blood Management Protection Plus system allows the withdrawal of blood samples from
pressure monitoring lines.
• Designed for use with disposable pressure transducers and for connection to central line catheters,
venous catheters, and arterial catheters where the system can be flushed clear after sampling.
• Blood sample sites incorporate familiar needleless technology for added safety.
12 cc Reservoir
VP1 VAMP Plus system reservoir with 60” patient tubing and one sample site CS (10)
located 55” from the patient
VP2 VAMP Plus system reservoir with 60” patient tubing and two sample sites CS (10)
located 13” and 55” from the patient
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
21
VAMP Jr. System Kits
The VAMP Jr. closed blood sampling system provides a safe and convenient method for withdrawing
blood samples.
• Designed for connection to umbilical, arterial, and central line catheters and for use with
disposable and reusable pressure transducers, if desired.
• The VAMP Jr. reservoir is used for drawing and retaining diluted blood (or clearing volume)
from an in-line sampling site.
2cc
1cc
Distal
Proximal
(To Patient)
Needle*Less Shut-Off Reservoir Needle*Less Shut-Off
Sampling Site Valve Access/Flush Site Valve
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
22
TruWave Transducers/VAMP System Combination Kits
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
23
TruWave Transducers/VAMP Plus System Combination Kits
PXVP2260 TruWave disposable pressure transducer/VAMP Plus system kit with 60” CS (10)
patient tubing and two sample sites located 13” and 55” from the patient
PXVP2272 TruWave disposable pressure transducer/VAMP Plus system kit with 72” CS (10)
patient tubing and two sample sites located 13” and 55” from the patient
PXVP2284 TruWave disposable pressure transducer/VAMP Plus system kit with 84” CS (10)
patient tubing and two sample sites located 13” and 55” from the patient
PXVP23X3 TruWave disposable pressure transducer/VAMP Plus system kit with three CS (10)
TruWave transducers, 60” patient tubing and two sample sites located 13”
and 55” from the patient
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
24
TruWave Disposable Pressure Transducer Accessories
54IV12 Single line macrodrip IV set with 60” main line CS (10)
54IV22 Bifurcated macrodrip IV set with 36” main line and 9” extension legs CS (10)
IV32 Trifurcated macrodrip IV set with 36” main line and 9” extension legs CS (20)
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
25
TruWave Disposable Pressure Transducer Accessories
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
26
Pediatric Hemodynamic Monitoring
Hemodynamic Monitoring
PediaSat Oximetry Catheters
Pediatric
PediaSat oximetry catheters are pediatric central venous catheters with the added capability for the
continuous monitoring of central venous oxygen saturation (ScvO2).
• Continuous ScvO2 monitoring to assess the balance of oxygen delivery and consumption.
• Compatible with Edwards optical module and Edwards monitors including: Vigileo,
Vigilance II and Explorer monitors and SAT-2 device.
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
27
Hemodynamic Monitoring
Swan-Ganz pediatric catheters serve as diagnostic tools for the physician to continuously monitor
mixed venous oxygen saturation.
Thermistor
Thermistor Connector
Distal Lumen
Distal Lumen RV Port @ 19 cm
Hub
Proximal Injectate
Port @ 30 cm
Proximal Injectate
Lumen Hub
RV Paceport
Lumen Hub
(Pacing/Infusion)
The pressure monitoring kit with the TruWave disposable pressure transducer is a sterile, single-use kit
that monitors blood pressure when attached to pressure monitoring catheters.
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
28
Hemodynamic Monitoring
VAMP Jr. Closed Blood Sampling System
Pediatric
The VAMP Jr. closed blood sampling system provides a safe and convenient method for withdrawing
blood samples.
• Designed for connection to umbilical, arterial, and central line catheters and for use with
disposable and reusable pressure transducers, if desired.
• The VAMP Jr. reservoir is used for drawing and retaining diluted blood (or clearing volume)
from an in-line sampling site.
2cc
1cc
Distal
Proximal
(To Patient)
Needle*Less Shut-Off Reservoir Needle*Less Shut-Off
Sampling Site Valve Access/Flush Site Valve
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
29
Central Venous Access
Vantex catheters with Oligon** material, are the first central venous catheters made of a biocompatible
and antimicrobial** material.
• The Vantex central venous catheters are the only central venous catheters extruded from
polyurethane, combined with the natural elements of silver, carbon and platinum.
• The Oligon material releases silver ions from the device surfaces, which kills colonizing bacteria.
Proximal Lumen
Sheath
Distal Lumen
Suture Ring
Suture Wings
Medial Lumen
• Multiple uses include fluid administration, blood sampling and pressure monitoring.
• Also available with or without AMC Thromboshield* coating, an antimicrobial† heparin coating.
Proximal Lumen
Sheath
Distal Lumen
Suture Ring
Medial Lumen
Suture Wings
Central Venous Access
* All model numbers with an “H” contain AMC THROMBOSHIELD coating (an antimicrobial† heparin coating). Antimicrobial activity associated with
AMC THROMBOSHIELD coating has been demonstrated using in vitro diffusion agar assays against the following organisms: Staphylococcus epidermidis,
Staphylococcus aureus, Streptococcus faecalis, Candida albicans, Escherichia coli, Serratia marcescens, and Acinetobacter calcoaceticus.
† Decreases viable microbe count on surface of product during handling and placement.
For educational materials to supplement this product visit www.Edwards.com/Education or contact your Edwards Lifesciences sales representative.
33
Customer Service and Ordering Information
Ordering Information
Mailing Address
Edwards Lifesciences
One Edwards Way
Irvine, CA 92614
Telephone
General Offices 949-250-2500
Customer Service 800-424-3278 (or 949-250-2500)
Customer Service (fax) 800-422-9329 (or 949-250-3489)
Technical Support 24-Hour Emergency Assistance 800-822-9837 (or 949-250-2222)
Electronic
Edwards Lifesciences is a partner of the Global Healthcare Exchange (GHX). You may also place orders on-line with
My Account, Edwards web ordering system, at www.Edwards.com. For more information about buying our products
using My Account or GHX, please speak with a Customer Service Representative.
Web Site www.Edwards.com/CriticalCare
In Canada
Edwards Lifesciences, Inc. 800-268-3993
Terms and Conditions
Prices subject to change without prior notice. All applicable taxes will be charged.
Payment
Net 30 days except in Canada where payment terms are in accordance with those stated on the invoice.
Freight
FOB shipping point (prepaid and billed). All merchandise should be inspected on arrival. If merchandise has been damaged
in transit, please instruct your receiving department to refuse delivery; then notify Customer Service for further instructions.
For educational materials to supplement any of the products in this catalog visit www.Edwards.com/Education or contact your Edwards Lifesciences
sales representative.
34
Instructions for Returning Used Product
Edwards Lifesciences requests that all products be double-bagged prior to returning them and, if possible, please
follow these instructions prior to bagging:
• Prior to handling used product, put on disposable gloves and gown according to hospital procedures.
• Visually inspect the product and remove all needles.
• Remove all external organic material by carefully wiping the exterior surface with gauze pad or paper towel
saturated with tap water.
• Carefully wipe exterior surface of electrical components and connections.
• Wipe dry with gauze or paper towel.
• Wiping may also be done using one of the following:
-rubbing alcohol
-normal saline
-Cidex
-Omnicide
• Do not use any other cleansing agents other than those listed above; other agents may interfere with
evaluation testing.
• CAUTION:
Do not flush blood products from lumens or pressure tubing.
Do not immerse or submerge product in water.
Do not wrap product in tissue paper or apply adhesive tape directly to product; attachments to the product or
writing on the product may interfere with evaluation testing.
• Double-bag using two self-sealing plastic bags. First, place product in one bag and seal. Then place bagged product
in second bag and seal.
• Wash hands with soap and water.
• Complete Returned Goods Documentation, describing the reason for return, and staple or paper clip it to top of
plastic bag.
NOTE: Documentation must remain on the outside of the plastic bag to avoid contamination. Attach customer
identification label to outside of plastic bag. Place bagged product into shipping container, place mailing label with
Edwards Lifesciences address on the shipping container, and mark the container with the wording “Used Product.”
Return Address
All Products
Edwards Lifesciences Corporation
For educational materials to supplement any of the products in this catalog visit www.Edwards.com/Education or contact your Edwards Lifesciences
sales representative.
35
Notes
A heritage of developing leading solutions
that advance the care and treatment of the critically ill
Critical care clinicians around the world have used Edwards products to clinically
manage more than 30 million patients. Hemodynamic monitoring products such
as Swan-Ganz catheters, the FloTrac system and PreSep and PediaSat oximetry
catheters enable clinicians to make more informed and rapid decisions when
treating patients in surgical and critical care settings.
Edwards Lifesciences LLC · One Edwards Way · Irvine, CA 92614 USA · 949.250.2500 · 800.424.3278 · www.Edwards.com/CriticalCare