You are on page 1of 6
APOSTAR Medical DEDICATED CONTRAST MEDIA INJECTOR FOR CT C € 0123, xcellence Dor Se | @G “Variable Flow Rate” injection technology ‘APOSTAR unique Varisble Flow Rate injection technology allows contrast media tobe uniformly dsbvted throughout the region of Interest ROD This maximizes the value ofthe contrast media, proves image quality and allows 2 reduced volume of contast edi te beinjectd,Compleximeging is more manageable ad the capabilities of new scanners an be ull tized with he repeoducklity of complex seannets. Th tchnelogy is pariculay suitable for peripheral run-off stdies, PE studies and Cardiac CTA stuaies. ‘TEC comparison between linear and Comparison chart of single-phase injection vata Now ate and variable speed Injection © Built in heat maintainer espe contastmadia at convenient temperature No need to ‘cover the syringe with heating dove: Increasing exer: etter visualization of i bubbles Increasing relay QY "Three Phase” Injections entice Septum Pi matey ees eet nents {eter sane Orton bc econ APIO See ee ee See ee etete raaae cman ‘tear mtncesb once ane oe Coronary tery lIntelligent | =, EE QY smart Ancillary injection System [APOSTAR': unique smartinjecton features voi the ned to enter njacton parameters one by ane Select thearea tobe scanned (ON and the APO200 will automaticaly generate the injection parameters STEP : Select Body area STEP 2 Enter patient body weight STEP 3 Inject ‘and contrast media concentration YY) Different injection Modes Single syringe contrastinjectiny = Contrast flowed by saline fsh; “Saline flowed by contrast Simultaneous injection of contrast saline. Muit-phase smeray (YS Clear, Easy To Read Colour User Interface Bright 104"colour LED touch screen easy switches between ferent languages. The bul nterace provides vatous ‘options clear ata glance and is Wendy operated. A time deploy functions provided on thelower ight sie ofthe screen. | Safety @& High sensitivity real-time pressure curve technology |AP0200is equipped with area “Pressure Sensor which s parmanently contlling pressure al along injction-This technology ‘much more accurate, reliable and safe than using traditional “motor current” detection technology. Thisfetureis ficiently Increasing patient safety. ‘once developed pressures reaching set Pressure Limi istay nicl just below that set Lit. Cover protection Clear plastic coveris designed such way that It protects injector RAMS frm fi penetration in injector head and bearings. + leprotects operator safety: “Itdoes not hide the syringe, allowing maximum ait bubble ‘sualstion Check air bubbles with LED lights LED lights allow an easy visual detection or air bubble presence increasing patient safety Moreover syringe cre has drawing allowing operator to detect ud inthe syringe round = fi: oval= i) Anti-Drop cap & Rotating Luer Lock -APOSTAR unique antdrop design ofthe tubing cap provides many beret: Stelly protection: when syringe andtubing ate purged cap protects tubing inte till patient connexion: Emvirenmental protection. Drops are callected inthe cap after the procedure ficient avoiding mess caused by contrast media dropping fn the ground or equipment, = Alour Apollo disposables arerated 350 PSL Rotating Lue Lackis minimizing extravasation rks and knot bigger than aFKLL cen et eee Technical Data ery cry Flow Rate (1-10.05 (0./snerement) 21-100r (0.1/sinerement) Volume 1-20 (1 ml ncrement) 1-200! (1 ml increment) Masi Pressure Lit 350051 Injection Mode ‘Mutt phase Scan Dey 03005 (ierphase) menial 0300s Hest Maintainer Buln Temperature Control Heating (38° +/-39) Rated Voltage 230A S0Ha/T SAV 60H Cansumpton 2s0vn Configurations Pedestaistandard/Celing (Option) Syringes 100ml syringe/200ml syringe NPO2OO irrossbiesaremade up of highly clon mate wth hich pressure resitance Allproduction tps ofAPO200 caposobles arecontralledby Sint Quity Management Tis nt ny incressng Safty, but ato opiiaes hpi operation cots APO200 indeed the bet choice for Contrast Ijetor. 200m! Syringe 100m! Adaptor 100m! Syringe Ceution: Safety & Performance of APO200 cannot be warranted if use with syringes or dsposabes othe than approved by Company. ‘Speetcations Appearance, 2s shown in ths brochure, canbe changed by Company without nonce. APOLLO RT Co., Ltd. Unit 1101, 11/6, Tower 1, Cheung Sha Wan Plaza, $33 Cheung Sha Wan Road, Lai Chi Kok, Kowoon, Hong Kong Te852-2781-3481 emait contacteapollost.com Manactued by APOSTAR Medical (Shanghai) Limited Suit B, 2, Building 3,No.1151, Liana Rd Pudong, Shanghai Ver2019.07

You might also like