You are on page 1of 1

CERTICATE OF ANALYSIS

Batch Detail
Batch No. : 12365 Batch date : 11 -12 – 2021

Cylinder Detail
Container No. : 58125025 Cly 3

Capacity/valve : 58 ltrs. W/C Alumunium Canister/C10

Filling Pressure (g) : +/- 500 PSI

Gas Content : 58 LTRS

Filling Details
Method : Gravimetric Filling method as per ISO 6142

Analysis Details
No Sr Components Contents Units Certification Analytical
Accuracy Method
1 HYDROGEN SULFIDE 25 PPM (V/V) +/- 5% IR Sensors
2 CARBON MONOXIDE 50 PPM (V/V) +/- 5% IR Sensors
3 ISOBUTANE 0.9 %(V/V) +/- 5% Gas Chromotography
4 OXYGEN 12 %(V/V) +/- 5% Gas Chromotography
5 NITROGEN BALANCE %(V/V) +/- 5% Gas Chromotography

Expiry Date : Dec-2023


Traceability : H2S : NIST : SRM 2731 (Expiry Date 26/3/2021) ; CO : NIST : SRIM 1677c (Expiry Date
18/7/2026)/ 1679c (Expiry Date 25/9/2022); Oxygen : NIST ; SRM 2659a (Expiry Date
27/02/2026); To NIST and International SI units via a chain of valid calibrations, through
calibration Certfs : MWS/CC/2020/860-001, 003, 009, 018, 025 valid till 24-01-2022

Precantions
• Observe safety precautions detailed in the MSDS for the cylincer contents.
• For best result use the cylinder up to minimum pressure +/- 10 % filling pressure
• Observe safety precautions for compressed gas cylinders.
• Recommended temperature for storage and use of cylinder content is between 200C to 350C.

This is computer generated report no signature required