0% found this document useful (0 votes)
142 views16 pages

One Way - Shear Check

The document contains calculations for the design shear resistance (VR,dc) of concrete strips with different geometries and reinforcement details. It provides values for parameters used in the shear resistance calculation such as the concrete compressive strength (fck), reinforcement ratio (Rho,1), shear span (d), and applied shear force (Vu). The resulting shear resistance capacities (VR,dc) range from 45 kN to 1925 kN for the various strip configurations.

Uploaded by

VAIBHAV
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views16 pages

One Way - Shear Check

The document contains calculations for the design shear resistance (VR,dc) of concrete strips with different geometries and reinforcement details. It provides values for parameters used in the shear resistance calculation such as the concrete compressive strength (fck), reinforcement ratio (Rho,1), shear span (d), and applied shear force (Vu). The resulting shear resistance capacities (VR,dc) range from 45 kN to 1925 kN for the various strip configurations.

Uploaded by

VAIBHAV
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

CRd,c = 0.

12 fck = 30 Mpa

γc = 1.5

d= 350 mm

k= 1.76

Strip Width = 800 mm

Asl = 452 mm2

Rho,1 = 0.0016

N,Ed = 0N

Length of concrete = 800 mm

Ac = 280000 mm2

Vu = 55 kN

Ϭcp = 0.00 Mpa

k1 = 0.15

Vmin = 0.519 N

VR,dc = 145303.984 N

VR,dc = 145 kN
CRd,c = 0.12 fck = 30 Mpa

γc = 1.5

d= 350 mm

k= 1.76

Strip Width = 10600 mm

Asl = 5989 mm2

Rho,1 = 0.0016

N,Ed = 0N

Length of concrete = 10600 mm

Ac = 3710000 mm2

Vu = 191 kN

Ϭcp = 0.00 Mpa

k1 = 0.15

Vmin = 0.519 N

VR,dc = 1925277.79 N

VR,dc = 1925 kN
CRd,c = 0.12 fck = 30 Mpa

γc = 1.5

d= 350 mm

k= 1.76

Strip Width = 800 mm

Asl = 452 mm2

Rho,1 = 0.0016

N,Ed = 0N

Length of concrete = 800 mm

Ac = 280000 mm2

Vu = 45 kN

Ϭcp = 0.00 Mpa

k1 = 0.15

Vmin = 0.519 N

VR,dc = 145303.984 N

VR,dc = 145 kN
CRd,c = 0.12 fck = 30 Mpa

γc = 1.5

d= 350 mm

k= 1.76

Strip Width = 5940 mm

Asl = 3356 mm2

Rho,1 = 0.0016

N,Ed = 0N

Length of concrete = 5940 mm

Ac = 2079000 mm2

Vu = 158 kN

Ϭcp = 0.00 Mpa

k1 = 0.15

Vmin = 0.519 N

VR,dc = 1078882.08 N

VR,dc = 1079 kN
CRd,c = 0.12 fck = 30 Mpa

γc = 1.5

d= 150 mm

k= 2.00

Strip Width = 400 mm

Asl = 226 mm2

Rho,1 = 0.0038

N,Ed = 0N

Length of concrete = 400 mm

Ac = 60000 mm2

Vu = 39 kN

Ϭcp = 0.00 Mpa

k1 = 0.15

Vmin = 0.767 N

VR,dc = 46008.6948 N

VR,dc = 46 kN
CRd,c = 0.12 fck = 30 Mpa

γc = 1.5

d= 150 mm

k= 2.00

Strip Width = 10600 mm

Asl = 5989 mm2

Rho,1 = 0.0038

N,Ed = 0N

Length of concrete = 10600 mm

Ac = 1590000 mm2

Vu = 180 kN

Ϭcp = 0.00 Mpa

k1 = 0.15

Vmin = 0.767 N

VR,dc = 1219230.41 N

VR,dc = 1219 kN
CRd,c = 0.12 fck = 30 Mpa

γc = 1.5

d= 150 mm

k= 2.00

Strip Width = 400 mm

Asl = 226 mm2

Rho,1 = 0.0038

N,Ed = 0N

Length of concrete = 400 mm

Ac = 60000 mm2

Vu = 35 kN

Ϭcp = 0.00 Mpa

k1 = 0.15

Vmin = 0.767 N

VR,dc = 46008.6948 N

VR,dc = 46 kN
CRd,c = 0.12 fck = 30 Mpa

γc = 1.5

d= 150 mm

k= 2.00

Strip Width = 5940 mm

Asl = 3356 mm2

Rho,1 = 0.0038

N,Ed = 0N

Length of concrete = 5940 mm

Ac = 891000 mm2

Vu = 150 kN

Ϭcp = 0.00 Mpa

k1 = 0.15

Vmin = 0.767 N

VR,dc = 683229.118 N

VR,dc = 683 kN