You are on page 1of 8
MAGNETIC LEVEL GAUGE MODEL : MLG ar * Simple, robust and unbreakable design i : = Fully separation between the measurement (wet parts) and the level indicator (dry parts) *Norisk of leakage, clear indication and very good visibility even from far away * Do not require an auxiliary power source and extremely low maintenance cost ¢ Usable in all type of liquids, aggressive, combustible, poisonous, hot etc ‘ * Can be equipped with magnetic switches and level sensor transmitter a, _ + Designs available for pressure ranges from vacuum up to +400 Barg ‘ * Design available for temperature up to 400 °C ri * Design available for density as low as 450 kg/m3 DESCRIPTION Magnetic level gauge, type: MLG is simply constructed and resistant to adverse condition of temperature and pressure. Since there are no glasses or Mica sheets as used in the conventional level gauges which may crack or break is some of the reasons why many industrial users favors this design. MLG Magnetic level gauge have a construction of material 304SS, 3168S, PVC, CPVC, PP, PVDF or PTFE that using for most applications in industries such as ~ Chemical, Petrochemical, Oil & Gas and other corrosive process. - Refrigeration, Retorts and Heat Treatment - Boilers, Evaporators, Condensers & Storage Tanks - Marine and Almost all sector Industries. OPERATION PRINCIPLE Magnetic level gauge MLG consist of some important parts that will be working together as one unit. The Working principle was simple, a vertical measuring chamber (1) is connected to the liquid vessel at each end (side to side, side to bottom, top to bottom) contains a float (2) with a built-in permanent magnet (3) inside that will rises and falls with the liquid level. The chamber is completely sealed so that the only moving part that contacts the liquid is the FLOAT itself. On the "DRY SIDE” of the chamber, a magnetic strip indicator (4), a column of bi-color magnetic tabs (5) that form a vertical strip to provide a visual indication of the fluid level attached. As the float moves up or down, the permanent magnet mounted in its top section of float "PULL" the tabs through a rotation of 180 Deg thus changing their color. As the float rises the tabs are turned from WHITE to RED and as the float falls, they changed back to WHITE again. This means that the liquid level inside the vessel is constantly represented by a RED strips without using any external power supply. The Magnetic level gauge MLG can be also equipped with several choices such as - MAGNETIC SWITCH - LEVEL SENSOR & TRANSMITTER APPLICATION SAMPLE DCS or BAS MAGNETIC LEVEL GAUGE, 304SS or 316SS No| DESCRIPTION MATERIAL & DATA Vent Plug 3048S or 316SS Plug 1/2" NPT (Standardl) Plug 3/4” NPT, Valve or Flange (Optional Guide Pipe 304SS or 316SS, 2" Sch 10 (Standard) 3048S or 316SS, 2° Sch 20 (Optional) Process Conn | 304SS or 316SS, Flange JIS, ANSI, DIN ‘Screw, NPT or BSP Male or Female Level Transmitter | 304SS / 316SS , Sensor Tube (OPTIONAL) | Aluminium IP-88 Housing or Ex-proof Output 4-20 mA, 2 wire system, 24Vdc or 3 Wire Potentiometer Flapper Clamp | 304SS Flapper Rail Aluminium, Max length = 6000mm Flapper Indicator | PA66+30% GF, Red + White & Yellow Magnetic Switch | PA66+30% GF or Ex-Proof Alum. (OPTIONAL) SPDT Reed Contact, 1A, 230 VAC/DC Flapper Cover | PA66+30%GF Flange Bottom |304SS/316SS. Flange, 2" JIS 10K (Standard) Optional 2° ANSI 150RF or 300 RF © 11|Drain Valve/Plug |304SS or 316SS, Plug 1/2" NPT (Standard) Plug 3/4” NPT or Valve (Optional) 12|CM Scale ‘Aluminium + Acrylic OR (OPTIONAL) 3048S Plate with Etching Magnet Float FMS = 316LSS ou FMT = Titanium aoe L= Length (C to C) , Up to 5700 mm (Straight Pipe) S ; Up to 22000 mm (Connecting Pipe) Pressure / Temp Max = 16 Barg / 200 °C (Standard) Higher Pressure and Temperature available on Request FLOATS & DIMENSION L Cs PRESS MAX|TEMP MAX) DENSITY | L. @ LF MODEL |MATERIAL| APPLICATION (Barg) (eC) | _(Ka/m3) | (mm) | (mm) | (mm) Fms-160 | _316LsS 16 200 900 160 50_| £110 | Water Hot Water, Chemical ete FMs-200 | _316LsS 16 200 800 200 50__| #150 | _ Diesel Fuel, Oil ete FMs-250 | _316LsS 16 200 700 250 50__| £200 | Fuel oil, chemical ete Fims-300 | _316LsS 16 200 650 300 50__| #250 | LowDensity Liquids FMS-300/HT| 316185 16 350 800 300 so__| #250 Hot Thermal Oil Fit-400_| TITANIUM 16 200 450 400 50 | £350 {LPG (Liquids) or ther as Liquids 3 MAGNETIC LEVEL GAUGE, PVC or CPVC No| DESCRIPTION MATERIAL & DATA Upper Cover PVC or CPVC 2" Cap (Standard) PVC or CPVC 2" Union (Optional) Tee Connection | PVC or CPVC 2° Sch 80 (Standard) 3|Process Conn | PVC or CPVC, Flange JIS, DIN or ANSI 4 | Level Transmitter | PVC or CPVC 14’ Sch 80, Sensor Tube (OPTIONAL) PP Housing IP-65 (Standard) Output 4-20 mA, 2 wire system, 24Vde or 3 Wire Potentiometer 5 |Flapper Clamp | 304SS 6 | Guide Pipe PVC or CPVC, 2° Sch 80 7 | Flapper Rail ‘Aluminium 8 | Flapper Indicator | PA66+30% GF, Red + White & Yellow 9 | Magnetic Switch | PA66+30% GF or Aluminium Ex-Proof (OPTIONAL) SPDT Reed Contact, 1A, 230 VACIDC 10|Flapper Cover | PA66+30% GF 11|Bottom Cover | PVC or CPVC, Union 2" Sch80(Standard} Flange JIS, ANSI or DIN (Optional) 12)CM Scale ‘Aluminium + Acrylic (OPTIONAL) 13|Magnet Float FMPP = PP (Polypropelene) FMDF = PVDF L= Length (C to C) , Up to 5700 mm (Straight Pipe) , Up to 10000 mm (Connecting Pipe) 10) Pressure / Temp Max = 3 Barg / 50 °C (PVC) Pressure / Temp Max = 3 Barg / 80 Deg C (CPVC) Cp tom v FLOATS & DIMENSION L PRESS MAX|TEMP MAX) DENSITY | L o | LF MopEL |marerIAL| PRESS Mt co) | aid) | (mm) | (rem) | (mm) | APPLICATION Fmpp-160 | __ PP 3 80 900 aso | 45 | +130 | Hcl, NaoH and other Chemicals Fupv-180 | _ PVDF 3 300 900 3so_| 45 | +150 | 2504.8 strong acids For Floats Request not in our standard dimension, please contact and Discuss. 4 TOP MOUNTING MAGNETIC LEVEL GAUGE, 304SS or 316SS No} DESCRIPTION MATERIAL & DATA 1 | Vent Plug 3048S or 3168S, Plug 1/2" NPT (Standardl) Plug 3/4” NPT, Valve or Flange (Optional 2 | Level Transmitter | 304SS or 316SS, Sensor Tube (OPTIONAL) | Aluminium IP-68 Housing or Ex-proof Output 4-20 mA, 2 wire system, 24Vde or 3 Wire Potentiometer 3 | Guide Pipe 3048S or 3168S, 2" Sch 10 (Standard) 3048S or 316SS, 2° Sch 20 (Optional) 4) Cm Scale Aluminium + Acrylic OR (OPTIONAL) | 3048S or 3168S Etching plate Flapper Clamp | 304SS. Flapper Indicator Magnetic Switch (OPTIONAL) Flapper Cover Flange Conn 5 6 | Flapper Rail 5 8 11 /Process Conn Aluminium, Max length = 6000mm_ PAG6+30% GF, Red + White & Yellow. PAG6+30% GF or Ex-Proof Alum SPDT Reed Contact, 1A, 230 VAC/IDC PAG6+30%GF 304SS/316SS Flange, 1" JIS 10K 3048S or 316SS,Flange 4” JIS 10K, 4" ANSI 150RF or DN100/PN16 12) Float Rod 316SS, Rod = 5mm or Tube 13) Float FMSG = 316LSS L= Length , Maximum up to 3000 mm, Pressure / Temp Max = 16 Barg / 200 °C 3 iE FLOATS & DIMENSION PRESS MAX|TEMP MAX) DENSITY | L. MODEL |MATERIAL|PREE ) Cc) | (Kola) | (mm) | (mm) APPLICATION FMsG-250 | _316sS 16 200 600 150 90 _| Water Oi, NaOH and other Chemicals For Floats Request not in our standard dimension, please contact and Discuss. 5 MAGNETIC FLAPPER INDICATOR, FPA Magnetic level gauge will be equipped with magnetic flapper as an standard indicator. ‘The type of flapper flapper plastic type (FPA) with high temp plastic which can withstand temp working up to 250 Deg C. The flapper color are white, red and yellow. DESCRIPTION MATERIAL & DATA HOUSING Aluminium Anodized FLAPPER PA-66 + 30% GF COLORS White, Red & Yellow COVER Polycarbonate or Glass TEMP MAXIMUM 250 Deg C PROTECTION RATING P-65 OPTIONAL SCA = Cm Scale, Acrylic SCS = Cm Scale, SS MAGNETIC SWITCH, MS & MS-Ex Magnetic switch MS is a switch unit that mounted at the side of WINGEL MLG magnetic level gauge. The magnetic switch MS can be used for controlling pumps in emptying or filing processes as well as monitoring high or low alarms. The MS mounted at the aluminum flapper rail and can be adjusted at any position with easy slide movement. Wingel have 2 type of magnetic switch, the general type: MS and with explosion proof housing, MS-Ex, MODEL. MS MS-Ex BODY MATERIAL PA-66 + 30% GF Aluminium Alloy PROTECTION RATING IP-65 CONTACT OUTPUT Eexd IIC T6, ATEX, IP-65 TEMPERATURE MAXIMUM Change Over, SPDT, Bistable, 1A, 230VAC/DC, 40VA) 200 Deg C 125 Deg C TERMINAL HOUSING DIN Plug, Polyamid, IP-65|__ Aluminium Ex-proof. CABLE ENTRY PG-9 with Gland “A” NPT-F MSs MS-EX LEVEL SENSOR & TRANSMITTER, LTS Magnetic level gauge MLG also can be equipped with level sensor model: LTS-MLG. LTS-MLG is a reed type level sensor clamped on the MLG level gauge to provide continous output of 3 wire potentiometer signal connected to digital meter type: WP4 or WPS will be giving a continous digital display reading Itis also can be connected to TU, 2 wire transmitter that provide 4-20 mA ‘output signal to PLC or DCS or others. For hazardous location, the LTS can be use transmitter module of 5343B, that giving signal 4-20 mA ATEX or 5335-A with output of 4-20 mA HART and ATEX, LTS MODEL | DESCRIPTION Reed Type Level sensor RESOLUTION Distance between each sensor 5mm Distance between each sensor 10mm Distance between each sensor 15mm Distance between each sensor 20mm CODE2 | LENGTH L MLG, C to C lenght CODE 3 P OUTPUT 3 Wire Potenti meter or Resistance TU 4-20 mA, 2 wire system-General 5335-4, 5343-8 | 4-20 mA, 2 wire system-Ex-proof 4-20 mA HART, 2 wire system-Ex-proof | CODE 4 ENCLOSURE ‘Aluminium, 1P-68 Aluminium, Ex-proof, IP-651 ‘Ambient Temp Max up to 130 Deg C OPTIONS. ‘Ambient Temp Max up to 200 Deg C LTS |LTS-R10-L1000-TU-0-0 .. Example | LTS-Ex TRANSMITTER MODULE & DIGITAL METER POWER 10 - 30 Vde INPUT, 3 Wire Potentiometer| 2 Wire Resistant 3 Wire Potentiometer 2xRelays" | 2xRelays + 4-20mA 420mAy | Modbus RS-485" OUTPUT 4-20mA_ | 4-20 mAHart| 2x Relays uh RS-485 Modbus* | Modbus output option F Select 4 Output only] onl for Linear Funtion DISPLAY LCD, 0-100% 5 Digits LED, 20mm 5 Digits LED, 14mm 220 Vac or 24 Vde | 220 Vac, 12 Vde or 24 Vdc FUNCTION | Linear Only [ns vi Linear Tank or with nso 20 pont Linearization ORDERING CODE Gee Gere A B c D E F G MODEL | DESCRIPTION MLG__| Magnetic Level Gauge with Red + White + Yellow Indicator CODE 1 | CHAMBER TYPE A B c of _e— —~ fF [ ¢ CODE 2 | PROCESS CONNECTION 412" 3/4" asi 4-112" 2 CODE 3 | PROCESS CONNECTION RATING SB = BSP-Male SN = NPT-Male FJ40K = JIS 10K FISK = JIS 5K Fai50 = ANSI 150RF or FA300__| FD 16=PN16 or FD 40, cope 4 | MATERIAL $1= 3048S _[S2=316SS P=PVC CP = CPVC CODES | LENGTH (C to C} ae ‘Straight Pipe up to 5700mm, Conn Pipe up to 15000 mm. CODE 6 | MAGNETIC FLAPPER INDICATOR. FPA _| PAG6+30% GF Flapper, Alum Rail, T max = 200 °C FLOATS 'SS316L Please refer to page 3 & 5 PP or PVDF, Please refer to page 4 CODE8| OPTIONS 0 No Options Ms |" Magnetic Switch, please refer to page 6 LTS | Level Sensor, please refer to page 7 SCA/SCS|_Cm Scale, please refer to page 6 MLG-A-1FJ10K-S1-L1000-FPA-FMS160-MS. .. Example Measurement ¥ Control PT. WINGEL INSTRUMEN INDONESIA ‘Measurement & Control Citra 8 - Aerolink Blok. LO3 No. 25 - Citra Garden City JAKARTA BARAT Phone : 62-21-56955637, 56955638 Email : info@wingel.id / Webside : www.wingel.id 8

You might also like