UOP LLC PROJECT SPECIFICATION
25 E. Algonquin Road
Des Plaines, Illinois 60017-5017, USA 974901 — 602-N SHEET 1
Note: The information in this document is confidential and the property of UOP LLC and must not be disclosed to others or reproduced in any manner or used for any purpose whatsoever without its written permission.
REV DATE BY APVD REV DATE BY APVD
0 6NOV13 WPS SM
PRESSURE GAUGES

Notes:

1. Pressure gauges shown without tag numbers on the UOP P&I Diagrams shall be specified by the
Contractor in accordance with the general procedure guidelines shown below.
Pressure Gauge Range Selection Guidelines:
English Units Metric and SI Units
psig kg/cm2 (g) or bar (g) kPa (g) §
Operating Pressure Gauge Operating Pressure Gauge Operating Pressure Gauge
Range Range Range
Vacuum < P < 3 -30"Hg/ 0 /+15 Vacuum < P < 0.2 -1/ 0 / +1.5 Vacuum < P < 20 -100/ 0 / +150
3 < P < 10 0 - 15 0.2 < P < 0.6 0 - 1.0 20 < P < 60 0 - 100
10 < P < 20 0 - 30 0.6 < P < 1.0 0 - 1.6 60 < P < 100 0 - 160
20 < P < 40 0 - 60 1.0 < P < 1.5 0 - 2.5 100 < P < 150 0 - 250
40 < P < 65 0 - 100 1.5 < P < 2.5 0-4 150 < P < 250 0 - 400
65 < P < 90 0 - 160 2.5 < P < 4.0 0-6 250 < P < 400 0 - 600
90 < P < 120 0 - 200 4.0 < P < 6.5 0 - 10 400 < P < 650 0 - 1000
120 < P < 180 0 - 300 6.5 < P < 10 0 - 16 650 < P < 1000 0 - 1600
180 < P < 250 0 - 400 10 < P < 15 0 - 25 1000 < P < 1500 0 - 2500
250 < P < 350 0 - 600 15 < P < 25 0 - 40 1500 < P < 2500 0 - 4000
350 < P < 450 0 - 800 25 < P < 40 0 - 60 2500 < P < 4000 0 - 6000
450 < P < 600 0 - 1000 40 < P < 65 0 - 100 4000 < P < 6500 0 - 10000
600 < P < 900 0 - 1500 65 < P < 100 0 - 160 6500 < P < 10000 0 - 16000
900 < P < 1200 0 - 2000 100 < P < 150 0 - 250 10000 < P < 15000 0 - 25000
1200 < P < 1900 0 - 3000 150 < P < 240 0 - 400 15000 < P < 24000 0 - 40000
1900 < P < 3500 0 - 5000 240 < P < 420 0 - 600 24000 < P < 42000 0 - 60000

§ Pressure gauge selection guidelines for MPa (g) units are obtainable by dividing
the kPa (g) values listed above by 1000.
a. Provide compound gauge with appropriate upper range value on discharge of any pump taking
suction from a vessel operating under a vacuum.
b. Provide compound gauge at any ejector inlet.
c. Provide a pulsation dampener on any gauge associated with a reciprocating compressor or with a
reciprocating or proportioning pump.
d. Provide an excess flow check valve on inlet of any gauge operating above 1000 psig or
70 kg/cm2 (g) or 70 bar (g) or 7000 kPa (g) or 7 MPa (g).

Form QUA-16-3 602-N-3