You are on page 1of 1

NOTES:

01. ALL DIMENSIONS GIVEN ON THIS DRAWING ARE IN MILLIMETERS. DO NOT SCALE THE
DRAWINGS, ANY DISCREPANCIES FOUND SHOULD BE REPORTED TO THE RESPONSIBLE

'45'
ARCHITECT OR ENGINEER IMMEDIATELY.

252°33
02. IT IS THE RESPONSIBILITY OF THE CONTRACTOR OR BUILDERS TO ASCERTAIN AND
CONFIRM THAT ALL DIMENSIONS SHOWN IN THESE DRAWINGS SHALL COMPLY WITH THE
SITE DIMENSIONS AND LEVELS PRIOR TO PREPARING DRAWINGS AND EXECUTING THE

=
°
7° WORKS.

73

H
10

A
03. ALL WORKS ARE TO BE CARRIED OUT TO Q.C.S. AND OTHER RELEVANT CODES OF

F Q IBL
CONSTRUCTIONS.
04. FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS, REFER TO DRAWING NO.

IO N O
A-A0-0001.

REFER TO DRAWING NO.

REFER TO DRAWING NO.


05. FOR SIZES OF MECHANICAL WALL OPENINGS, REFER TO MECHANICAL DRAWINGS.

DIRECT

°
73
06. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH THE OTHER RELEVANT
1 2 3 4 5 6 7 8 9 10

1358-A-A1-00-0106

1358-A-A1-00-0104
ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWING AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.
69920 07. EXACT LOCATION & DETAIL OF ELECTRO-MECHANICAL OPENING SHALL BE COORDINATED
WITH ELECTRO-MECHANICAL ENGINEER.
8515 8085 8025 8425 6500 7800 6500 8150 7920 08. DIMENSION AND LOCATION OF SERVICES COORDINATED WITH RESPECTIVE ARCHITECTURAL
AND SERVICES DRAWINGS PRIOR TO COMMENCEMENT OF ANY WORK. ANY DISCREPANCY
FOUND SHOULD BE BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER.
09. REFER TO SCHEDULE OF FINISHES FOR FLOORS, WALLS AND CEILINGS.
10. ALL MATERIALS FINISHES AND WORKMANSHIP SHOULD BE OF HIGH STANDARD QUALITY OF
SHADED PARKING WORKS.
11. ALL TEXTURES AND COLORS SHOULD BE REFERRED TO SCHEDULE OF FINISHES AND HAVE
E APPROVAL OF ARCHITECT.
12. QND LEVELS ARE INDICATIVE ONLY AND TO BE VERIFIED ON SITE BY THE APPOINTED
5 1
1358-A-A1-00-0900
SHADED PARKING SHADED PARKING SHADED PARKING CONTRACTOR BASED ON SITE CONDITIONS. THE REQUIRED/RELEVANT ADJUSTMENTS ON
1358-A-A1-AA-0703
DRAWINGS FOR ALL DISCIPLINES (ARCH,CIVIL,MEP) TO BE DONE BY APPOINTED
CONTRACTOR WITHOUT ANY TIME AND COST IMPACT.
5755

13. THE PROPOSED BUILDING REFERENCE LEVEL SHALL BE ±0.00m FFL AT GROUND FLOOR
LEVEL IS EQUAL TO EL+4.70m QND LEVEL.
4 14. FOR SPECIFICATION & DETAILED INFORMATION OF SOUND INSULATION PLEASE REFER TO
PAVEMENT 1358-A-A1-AA-0703
2325 2000 1000 2000 1815 2000 1000 2000 5060 2000 1000 2000 1850 2000 975 2000 1720 2000 1000 2000 2850 2000 1000 2000 2900 ACCOUSTIC DRAWINGS & REPORT
SERVICE
W W W W W CYLINDER ROOM STAIRCASE-2 W W W W
05 05 05 05 05 00-0242 00-0123 05 05 05 05
E' D0105A D0105B D0105C
D0121 D0122 D0127C
KEY STAGE AGE ON ENTRY YEAR GROUP

850
D0242
UP UP
2445

D0275
SERVICE 3 YEARS FOUNDATION STAGE 1 (NURSERY)
ELEC 850 ELV

3040

3040

3040
3040
STAIRCASE-1 00-0121 00-0122 EARLY YEARS FOUNDATION
00-0120 STAGE (KG1) 4 YEARS FOUNDATION STAGE 2 (RECEPTION)
F

4760
6050 3300 DN
5910

3300 6000
18645 2405 7000 3250
2575 2000 2000 1200 1225 D0124 5 YEARS YEAR 1
12250
D0118E D0119E
HEATER ROOM D0267 KEY STAGE 1 (KS1)

2600
5500 775 00-0267 6 YEARS YEAR 2

CHANGING AREA FOR


D0127B
4950 4400

FEMALE WET

BEGINNER
D0268
7065

00-0118
D0118D D0119D
JAN RM NOTES:
00-0268

MALE WET CHANGING


FOR LABORATORIES , ATELIERS AND KITCHEN TO BE FINALIZED WITH OPERATOR FINAL REQUIREMENT.

AREA FOR BEGINNER


W D0125S D0125R
2000

05
FHR
D0125Q

00-0119
D0125T
D0118C D0119C CORRIDOR
00-0124
1200

D0125U D0125P HATCH HIGHLIGHTING THE AREA OF BASEMENT.

JAN RM D0273
F' W
D0118B D0119B
D0125N

7740
00-0273
2000
1135

SHADED PARKING 05

G FHR
JAN RM. D0266 D0125M
HEATER
00-0266 ROOM
D0118 D0125
FEMALE DRY
D0119
CHANGING AREA
4
2700

D0105D D0125L

15000
CORRIDOR 00-0125 UP

2200
BEGINNER'S SWIMMING POOL D0117 1358-A-A1-AA-0707
00-0117
D0125E
D0125B D0125K

20740
6625

D0125A

W STORE D0125F
2000

D0125J
05 5 D0115F D0116E 00-0264
D0264
1358-A-A1-AA-0707
D0272

3360
SWIMMING POOL D0125C D0125H
D0265 JAN RM
1200

D0115E D0116D 00-0265


D0125D D0125G

G' FHR
W
2000
1575

D0115D D0116C D0126D D0126G


05

DISCLAIMER: The CAD data is being supplied only to assist in production of the Sub-Consultant/Trade Contractor's work. It may contain some discrepancies and hence it should always be cross-checked with other relevant documents applying due diligence. Users are solely responsible for anything they produce using all or part of
SHADED PARKING
H

3245
50000

D0126C D0126H

11410
4675 4875
D0126F D0126J
2900

UP MULTIPURPOSE HALL

D0115C
D0115B

D0116B
FEMALE WET D0126A 00-0127
CHANGING AREA MALE WET D0126K
00-0115 D0126E EL +0.01 m FFL LINK SCHEDULE
CHANGING AREA
6185

4020

00-0116 D0126B
D0126L BLEACHERS RVT LINK NAME REVISION NUMBER
W MALE DRY
2000

D0126 CHANGING AREA 1358-AEB-ARC-MD3-BD01-AA-001 A


05 D0115A D0116A 00-0126 JAN RM 1358-AEB-ARC-MD3-BD01-AA-002 A
00-0271 D0271 HEATER
D0126M 1358-AEB-ARC-MD3-BD01-AA-003 A
ROOM 1358-AEB-ARC-MD3-BD02-AA-001 A
1200

7655
1358-AEB-ARC-MD3-BD03-AA-001 A
H' FHR D0116
D0126N 1358-AEB-ELE-MD3-BD01-AA-001 A
D0115 1358-AEB-FRS-MD3-BD01-AA-001
W
2000

9750
05 D0126U D0126P 1358-AEB-LSC-MD3-LAAA-AA-001 A
2815

SHADED PARKING D0124


D0105E 1358-AEB-MHV-MD3-BD01-AA-100

3355
CORRIDOR
00-0114 D0126T D0126Q 1358-AEB-PLU-MD3-BD01-AA-001 A
1358-AEB-STR-MD3-BD01-AA-001
J D0126S D0126R 1358-AEB-STR-MD3-BD02-AA-001
2800

8725

1358-AEB-STR-MD3-BD03-AA-001

200
AQUATIC SPORTS
00-0105
KEYPLAN: MAIN BUILDING PART-5
EL +0.00 m FFL
4945

LOBBY D0127A

3810

3810

the provided CAD data. CAD data is not intended to be issued to any third party without AEB's written consent for the same. In providing you with this CAD data, AEB does not assume any liability whatsoever unless expressed otherwise.
W 00-0110
2000

D0105F
05
16320
1200

D0106 D0108

200
J' FIRST-AID
D0113 00-0113 D0112
SHADED PARKING W 3900 3900 5650 3600 4200
2000

05
3255

3550
PE STAFF STORE
00-0106
PE STAFF 00-0112
5000

00-0108

K
7145

SHOWERS

900 6650
UP
D0107 D0109 9
1358-A-A1-AA-0801
UP
FIRESCAPE
5840

2850

3450
SHAFT STAIRCASE-4
4755

D0107A D0109A
00-0111
2200

T&B T&B
BLEACHERS 00-0107 00-0109
SHAFT D0098A D0110
D0111
450

D0105 D0103

K'
2315

2345
SWIMMING POOL D0100 MECH. ROOM
STORE D0099 00-0099 0 JAN 2019 ISSUED FOR CONSTRUCTION DK
UP 11825
00-0103
6125 4000 4400 3600 18400
2935

NO. DATE DESCRIPTION APPROVED


3445

RECYCLED / 1600
FHR AEB STAMP PLANNING APPROVAL

6350
NON-RECYCLED 2080 PE STORE 3800 INDOOR SEATING
5500

5500

GARBAGE ROOM 00-0101 ENTRY/ EXIT


RAMP UP

D0101 00-0098 D0097A


00-0104 00-0100

4005
L
3650
1765

D0104 EL -0.20 m FFL D0098

D0102
ELECTRICAL CABINET UP W W W W W W W24 W24 W24 W24 W24
00-0102 05 05 05 05 05 05
22370 1000 1900 800 1900 800 1900 800 1900 800 1900 800 1900 800 CONSULTANT:

SHADED PARKING
PAVEMENT 7
1358-A-A1-AA-0703
1 Arab Engineering Bureau
1358-A-A1-AA-0704
AEB HEADQUARTERS:
P.O. Box 1148 Doha, Qatar Tel +974 4406 88 88 Fax +974 4447 78 68
Email aeb@aeb-qatar.com Web www.aeb-qatar.com
OTHER BRANCHES:
MANILA * KUALA LUMPUR * MUSCAT

PROJECT :
UNITED SCHOOL INTERNATIONAL
C:\Users\Evelyn\Documents\1358-AEB-ARC-MD2-BD01-AA-100_Evelyn.rvt

(B+G+2)
OWNER :
UNITED DEVELOPMENT COMPANY
SITE :
REFER TO DRAWING NO. REFER TO DRAWING NO. THE PEARL QATAR,DOHA,QATAR
1358-A-A1-00-0106 1358-A-A1-00-0105 TITLE :

GROUND FLOOR PLAN - PART 5


PLOTTED DATE: 1/22/2019 5:08:29 PM

DRAWN BY : DESIGN BY : CHECKED BY : APPROVED BY :


ST4 SJ MS DK
DATE : SCALE @ A0:
JAN 2019 1 : 100M
1 GROUND FLOOR PLAN - PART 5
PROJECT NO : DRAWING NO : REVISION
1358-A-A1-00-0106
SCALE 1 : 100
1358-18 1358-A-A1-00-0106 0