User Manual
FMUSER FU-1000C FM Transmitter 1000 Watt
Remark:
Read this instruction manual carefully before using the product.
After reading it, please take care of this instruction to refer to it
The use of this transmitter, please comply with relevant local laws and regulations and the
relevant provisions of the radio management department, otherwise the resulting legal
responsibility shall be borne by the parties concerned, and has nothing to do with the company
1
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
II. Catalogue
●Product Features
●Product configuration
●Product operation instructions
●Product technical parameters
●General troubleshooting guide
●Contact details
●Disclaimer
● Interface d'entrée d'encodeur externe (un encodeur SCA ou RDS externe peut être connecté.
2
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
3
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
3.Operating instructions
(1) Power on
First, please set up the antenna and link it to the
RFOUT port of the transmitter. If you need to test
the equipment indicators, please connect the
attenuator greater than 1000W, the attenuation value
is greater than 50DB, and then access the utility, the
power switch to the "I" position for power on, "O"
position for power off, as shown in the figure on the
right.
After power on, the device enters the working status display interface. The display interface is
shown as follows.
4
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
Stereo/mono :
Lock status :
VSWR :
5
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
Press the rotary code switch to enter the menu control interface. When you turn the rotary
code switch, a total of 14 menu options are cyclically displayed on the display.
6
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
At this point, turn the code switch to select the desired operating frequency (FREQ:
87.0~108MHZ) in steps of 50.0KHz, and after setting, short press the code switch to confirm
and exit the frequency setting state.
At this point, turn the code switch, you can set the audio source, USB / RCA /
XLR three audio sources to switch at will. When the setting is completed, short
press the code switch to confirm and exit the audio source setting state.
7
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
At this time, turn the coding switch to set the audio volume, and the settable value range is
0~30. After the setting is completed, short press the code switch to confirm and exit the audio
volume setting state.
At this point, turn the code switch to turn off (POWER OFF) and on (POWER
ON) the transmitting power, and observe the current power output. When the setting
is complete, press the code switch to confirm and exit the power setting state.
At this time, turn the code switch to set the USB working status, and pause
(PAUSE) / play (PLAY) can be switched. When the setting is completed, short
press the code switch to confirm and exit the USB working state setting state.
point, you can switch between songs on the USB port, and the following display
appears.
At this point, turn the code switch to switch the USB song at will, turn one
frame counterclockwise to play the previous song, and turn one frame clockwise to
play the next song. After the setting is complete, short press the code switch to
confirm and exit the USB song switching.
Stereo/mono switching
In the menu options screen, select "ST/MO SET" in "MENU SET" by turning
the code switch, and then press the code switch to confirm the selection. At this
point, the audio mode is set, and the following display appears.
At this point, turn the code switch to switch the audio mode setting to
STEREO/MONO at will. When the setting is completed, press the code switch to
confirm and exit the audio mode setting state.
Pre-emphasis switching
In the menu, select "PRE-EMPHAISI SET" in "MENU SET" by rotating the
rotary code switch, and then press the code switch to confirm the selection. At this
point, the pre-emphasis switching mode is set and displayed as follows.
At this time, turn the coding switch to switch the pre-emphasis, 0 US/50 US/75
US at will. When the setting is finished, press the code switch to confirm and exit
9
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
At this point, turn the code switch to set the protection temperature, and the set
temperature range is 50~75℃. When the setting is completed, press the code switch
to confirm and exit the temperature protection setting state.
At this point, you can clearly check the alarm and usage status (alarm time /
alarm number / total number of alarms / alarm type / operating time / temperature /
VSWR / power) of the machine until now. After the query is completed, press the
code switch to confirm and exit the log record query status.
10
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
After a short wait, the machine will automatically scan the full-band VSWR
and give you the three best VSWR values at the end of the scan. Customers can
also select the corresponding low standing wave frequency according to the chart
drawn for their own use. After the scan is completed, press the code switch once
more to exit the interface.
At this time, turn the code switch, you can turn the machine lock screen
password on (ON) or off (OFF), long press the code switch to change the machine
lock screen password, the specific operation: first enter the old password (original
password: 1234), and then enter the new password to be set, set the completion of
the code switch to confirm and exit the machine lock screen password setting state.
At this time, the interface shows: "FMUSER1000W 100% 100%" indicates that
11
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
the 1000W machine power output and the RF signal detection in the primary (RD01)
and secondary (RD15) RF amplifier circuit is 100%; "V1.0.0 2022- 05-11" indicates
that the program version is V1.0.1 and the last modified time of the program is
2022-05-11; "2022-06-26 12:23:35" indicates that the current date is 2022-06-26
and the current time is 12:23:35, the date and time can be modified by long press on
the code switch. When the setting is finished, press the code switch to confirm and
exit the machine working status inquiry and setting status.
the code switch, and then press the code switch to confirm the selection:
12
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
13
FMUSER INTERNATIONAL GROUP INC www.fmradiobroadcast.com
If the above instructions still do not solve your problem, please contact our after-sales
engineer email address: support@fmuser.com