Professional Documents
Culture Documents
Line Tester Loop 2.1
Line Tester Loop 2.1
Topology: 2022-08-02-1144
Device List
L T Pos ID-Nr. Type Ra Rb Messages
LOOP2_1
OP720
1 2B609D3 201Ω n/a
ES:12 SW:12
OP720
2 2B6A044 203Ω 74.9kΩ
ES:12 SW:12
OP720
3 2B55FE6 207Ω n/a
ES:12 SW:12
OP720
4 2B609A5 204Ω n/a
ES:12 SW:12
OP720
5 2B57B04 204Ω 300kΩ
ES:12 SW:12
OP720
6 2B55FEF 203Ω 33.2kΩ
ES:12 SW:12
OP720
7 2B609A1 203Ω 42.8kΩ
ES:12 SW:12
OP720
8 2B609A0 201Ω 29.9kΩ
ES:12 SW:12
OP720
9 2B6099C 201Ω 21.3kΩ
ES:12 SW:12
OP720
10 2B591A1 200Ω 21.3kΩ
ES:12 SW:12
OP720
11 2B592E5 204Ω 99.9kΩ
ES:12 SW:12
OP720
12 2B609A6 205Ω 99.9kΩ
ES:12 SW:12
OP720
13 2B592B7 201Ω 99.9kΩ
ES:12 SW:12
OP720
14 2B5918D 203Ω 99.9kΩ
ES:12 SW:12
OP720
15 2B591AC 199Ω 42.8kΩ
ES:12 SW:12
OP720
16 2B609A8 204Ω 300kΩ
ES:12 SW:12
OP720
17 2B55FFF 201Ω 74.9kΩ
ES:12 SW:12
OP720
18 2B6A04C 202Ω 49.9kΩ
ES:12 SW:12
OP720
19 2B60886 200Ω 49.9kΩ
ES:12 SW:12
Confirmation
=> The yellow/green plug of the linetester was connected to earth.
=> For shielded cables:
• the shield was also connected to the yellow/green plug of the linetester.
• the shielding was continuous and had a resistance of ______ Ω.
Date: ____________________________________________________________
Name: ____________________________________________________________
Signature: ____________________________________________________________
Summary
Date
Customer Text 192.168.200.1, Module 2: PeriBoard 1, Connection: 3
Connection
Number of devices (total) 104
Branches 0
Line type Stub
Line current n/a
Leak current n/a
Errors
• E03: Open loop minus wire
Notes
• Ra and Rb are resistance values. Each represents the total resistance from the connection (a/b)
to the device.
• Resistance values Ra and Rb are only approximations! (ca. 10Ω)
• Each device contributes some resistance to the minus and plus wire. The amount on the minus
wire is larger.
• The leak current sums up a basic current needed by all devices plus any error currents due to
installation errors. It is measured at a reduced line voltage.
• The line current sums up the power requirement by all devices plus any error currents due to
installtion errors.
• Software version used: FXS2017 PC Linetester Tool V2.0.21
Resistance Plot
Visualization of the Ra/Rb values of each device.
Legend:
• horizontal axis: topology number of device
• vertical axis: resistance (sum of Ra + Rb)
• lower/blue: Ra
• upper/green: Rb
610
488
366
244
122
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
610
488
366
244
122
0
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
488
366
244
122
0
97
98
99
100
101
102
103
104