Which IO controller support the functions IRT, prioritized startup, MRP, PROFIenergy,

s Shared device, I device, Isochronous mode and System redundancy in STEP 7 V5.x?
Entry-ID: 44383954

Module Article number IRT Min. PROFINET I/O address area Ctrl-Ctrl-DDEB6) Max. data prioritized MRP MRPD PROFIenergy Shared device I device
send clock record length startup
(RT and IRT) (acyclic)

overall per integrated per IO device


IO system
S7-300 CPUs
CPU 314C-2 PN/DP 6ES7314-6EH04-0AB0 from V3.3 250µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V3.3 from V3.3 − from V3.3 from V3.3 ab V3.3
CPU 315-2PN/DP 6ES7315-2EH13-0AB0 − 1ms 2 kByte 2 kByte 1440 Byte − 27 kByte − − − from V2.5 − −
CPU 315-2PN/DP 6ES7315-2EH14-0AB0 from V3.2 250µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.1 from V3.2 from V3.2
CPU 315F-2PN/DP 6ES7315-2FH13-0AB0 − 1ms 2 kByte 2 kByte 1440 Byte − 27 kByte − − − from V2.5 − −
CPU 315F-2PN/DP 6ES7315-2FJ14-0AB0 from V3.2 250µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.1 from V3.2 from V3.2
CPU 315T-3PN/DP 6ES7315-7TJ10-0AB0 from V3.2 250µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2
CPU 317-2PN/DP 6ES7317-2EK13-0AB0 − 1ms 8 kByte 8 kByte 1440 Byte − 27 kByte − − − from V2.5 − −
CPU 317-2PN/DP 6ES7317-2EK14-0AB0 from V3.2 250µs 8 kByte 8 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.1 from V3.2 from V3.2
CPU 317F-2PN/DP 6ES7317-2FK13-0AB0 − 1ms 8 kByte 8 kByte 1440 Byte − 27 kByte − − − from V2.5 − −
CPU 317F-2PN/DP 6ES7317-2FK14-0AB0 from V3.2 250µs 8 kByte 8 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.1 from V3.2 from V3.2
CPU 317T-3PN/DP 6ES7317-7TK10-0AB0 from V3.2 250µs 8 kByte 8 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2
CPU 317TF-3PN/DP 6ES7317-7UL10-0AB0 from V3.2 250µs 8 kByte 8 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2
CPU 319-3PN/DP 6ES7318-3EL00-0AB0 from V2.7 250µs 8 kByte 8 kByte 1440 Byte − 27 kByte from V2.7 − − from V2.5 − −
CPU 319-3PN/DP 6ES7318-3EL01-0AB0 from V3.2 250µs 8 kByte 8 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2
CPU 319F-3PN/DP 6ES7318-3FL00-0AB0 from V2.7 250µs 8 kByte 8 kByte 1440 Byte − 27 kByte from V2.7 − − from V2.5 − −
CPU 319F-3PN/DP 6ES7318-3FL01-0AB0 from V3.2 250µs 8 kByte 8 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2
S7-400 CPUs
CPU 412-2PN 6ES7412-2EK06-0AB0 from V6.0 250 µs 4 kByte 4 kByte 1440 Byte − 32 kByte from V6.0 from V6.0 − from V6.0 from V6.0 from V6.0
CPU 412-2PN 6ES7412-2EK07-0AB0 from V7.0 250 µs 4 kByte 4 kByte 1440 Byte − 32 kByte from V7.0 from V7.0 − from V7.0 from V7.0 from V7.0
CPU 414-3PN/DP 6ES7414-3EM05-0AB0 from V5.2 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V5.2 − − from V5.0 − −
CPU 414-3PN/DP 6ES7414-3EM06-0AB0 from V6.0 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V6.0 from V6.0 − from V6.0 from V6.0 from V6.0
CPU 414-3PN/DP 6ES7414-3EM07-0AB0 from V7.0 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V7.0 from V7.0 − from V7.0 from V7.0 from V7.0
CPU 414F-3PN/DP 6ES7414-3FM06-0AB0 from V6.0 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V6.0 from V6.0 − from V6.0 from V6.0 from V6.0
CPU 414F-3PN/DP 6ES7414-3FM07-0AB0 from V7.0 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V7.0 from V7.0 − from V7.0 from V7.0 from V7.0
CPU 416-3PN/DP 6ES7416-3ER05-0AB0 from V5.2 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V5.2 − − from V5.0 − −
CPU 416-3PN/DP 6ES7416-3ES06-0AB0 from V6.0 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V6.0 from V6.0 − from V6.0 from V6.0 from V6.0
CPU 416-3PN/DP 6ES7416-3ES07-0AB0 from V7.0 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V7.0 from V7.0 − from V7.0 from V7.0 from V7.0
CPU 416F-3PN/DP 6ES7416-3FR05-0AB0 from V5.2 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V5.2 − − from V5.0 − −
CPU 416F-3PN/DP 6ES7416-3FS06-0AB0 from V6.0 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V6.0 from V6.0 − from V6.0 from V6.0 from V6.0
CPU 416F-3PN/DP 6ES7416-3FS07-0AB0 from V7.0 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte from V7.0 from V7.0 − from V7.0 from V7.0 from V7.0
CPU 412-5H PN/DP 6ES7412-5HK06-0AB0 − 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte − from V6.0 − − from V6.05) −
CPU 414-5H PN/DP 6ES7414-5HM06-0AB0 − 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte − from V6.0 − − from V6.05) −
CPU 416-5H PN/DP 6ES7416-5HS06-0AB0 − 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte − from V6.0 − − from V6.05) −
CPU 417-5H PN/DP 6ES7417-5HT06-0AB0 − 250 µs 8 kByte 8 kByte 1440 Byte − 32 kByte − from V6.0 − − from V6.05) −
Industrial Ethernet CPs S7-300 / S7-400
CP 343-1 Standard 6GK7343-1EX30-0XE0 − 250 µs 1 kByte 1 kByte 1433 Byte − 240 Byte from V2.2 from V2.2 − from V3.0 from V2.4 from V2.4
CP 343-1 Advanced 6GK7343-1GX30-0XE0 from V1.0 250 µs 4 kByte 4 kByte 1433 Byte − 240 Byte from V1.0 from V1.0 − − from V1.2 from V1.2
CP 343-1 Advanced 6GK7343-1GX31-0XE0 from V3.0 250 µs 4 kByte 4 kByte 1433 Byte − 240 Byte from V3.0 from V3.0 − from V3.0 from V3.0 from V3.0
CP 443-1 Standard4) 6GK7443-1EX20-0XE0 from V2.0 250 µs 4 kByte 4 kByte 1433 Byte − 240 Byte from V2.0 from V2.0 − from V2.1 from V2.1 −
CP 443-1 Standard 4)
6GK7443-1EX30-0XE0 from V3.0 250 µs 4 kByte 4 kByte 1433 Byte − 240 Byte from V3.0 from V3.0 − from V3.0 from V3.0 −
CP 443-1 Advanced4) 6GK7443-1GX20-0XE0 from V2.0 250 µs 4 kByte 4 kByte 1433 Byte − 240 Byte from V2.0 from V2.0 − from V2.1 from V2.1 −
CP 443-1 Advanced 4)
6GK7443-1GX30-0XE0 from V3.0 250 µs 4 kByte 4 kByte 1433 Byte − 240 Byte from V3.0 from V3.0 − from V3.0 from V3.0 −

This entry is from the Service&Pupport portal of Siemens AG, Siemens Industry Online Support.
Unrestricted Change date: 08/27/2022 Page: 1/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO controller support the functions IRT, prioritized startup, MRP, PROFIenergy,
s Shared device, I device, Isochronous mode and System redundancy in STEP 7 V5.x?
Entry-ID: 44383954

Embedded und PC-based Automation


WinAC RTX 2009 6ES7671-0RC07-0YA0 yes3) 1 ms8) 16 kByte 16 kByte 1440 Byte − 2 kByte yes − − yes − −
250 µs9)
WinAC RTX F 2009 6ES7671-1RC07-0YA0 yes3) 1 ms8) 16 kByte 16 kByte 1440 Byte − 2 kByte yes − − yes − −
250 µs9)
WinAC RTX 2010 6ES7671-0RC08-0YA0 yes3) 1 ms8) 16 kByte 16 kByte 1440 Byte − 2 kByte yes yes3) − yes yes −
250 µs9)
WinAC RTX F 2010 6ES7671-1RC08-0YA0 yes3) 1 ms8) 16 kByte 16 kByte 1440 Byte − 2 kByte yes yes3) − yes yes −
250 µs9)
S7-mEC EC31-RTX 6ES7677-1DD10-0BB0 yes 250 µs 16 kByte 8 kByte 1440 Byte − 2 kByte yes yes − yes yes −
S7-mEC EC31-RTX F 6ES7677-1FD10-0FB0 yes 250 µs 16 kByte 8 kByte 1440 Byte − 2 kByte yes yes − yes yes −
S7-mEC EC31-HMI/RTX 6ES7677-1DD10-0BF0 yes 250 µs 16 kByte 8 kByte 1440 Byte − 2 kByte yes yes − yes yes −
6ES7677-1DD10-0BH0 yes 250 µs 16 kByte 8 kByte 1440 Byte − 2 kByte yes yes − yes yes −
6ES7677-1DD10-0BG0 yes 250 µs 16 kByte 8 kByte 1440 Byte − 2 kByte yes yes − yes yes −
SIMATIC NET PC-Software und PN Treiber
CP 1616 6GK1161-6AA01 from V2.0 250 µs 8 kByte 8 kByte 1430 Byte − 4096 kByte from V2.2.0 from V2.2.0 − from V2.5.2 from V2.5 from V2.5.2
CP 1616 6GK1161-6AA02 from V2.0 250 µs 8 kByte 8 kByte 1430 Byte − 4096 kByte from V2.2.0 from V2.2.0 − from V2.5.2 from V2.5 from V2.5.2
CP 1604 6GK1160-4AA00 from V2.0 250 µs 8 kByte 8 kByte 1430 Byte − 4096 kByte from V2.2.0 from V2.2.0 − from V2.5.2 from V2.5 from V2.5.2
CP 1604 6GK1160-4AA01 from V2.0 250 µs 8 kByte 8 kByte 1430 Byte − 4096 kByte from V2.2.0 from V2.2.0 − from V2.5.2 from V2.5 from V2.5.2
SOFTNET PROFINET IO − − − 4096 Byte 4096 Byte 1433 Byte − 4096 kByte − − − from V8.2 from V8.1 from V8.1
ET 200S
IM 151-8 PN/DP CPU 6ES7151-8AB00-0AB0 from V2.7 250 µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V2.7 − − from V2.7 − −
IM 151-8 PN/DP CPU 6ES7151-8AB01-0AB0 from V3.2 250 µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2
IM 151-8F PN/DP CPU 6ES7151-8FB00-0AB0 from V2.7 250 µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V2.7 − − from V2.7 − −
IM 151-8F PN/DP CPU 6ES7151-8FB01-0AB0 from V3.2 250 µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2
ET 200pro
IM 154-8 CPU 6ES7154-8AB00-0AB0 − 250 µs 2 kByte 2 kByte 1440 Byte − 27 kByte − − − from V2.5 − −
IM 154-8 CPU 6ES7154-8AB01-0AB0 from V3.2 250 µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2
IM 154-8F CPU 6ES7154-8FB01-0AB0 from V3.2 250 µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2
IM 154-8FX CPU 6ES7154-8FX00-0AB0 from V3.2 250 µs 2 kByte 2 kByte 1440 Byte − 27 kByte from V3.2 from V3.2 − from V3.2 from V3.2 from V3.2

1)
f you use a F-CPU as PROFINET IO-Controller, the "Failsafe" function and "Isochronous mode" function should not take place together in one IO device.
2)
The CPU supports the "Isochronous mode" function only as IO controller.
3)
The function is only supported over CP 1616 or CP 1604.
4)
With S7-400 Industrial Ethernet CPs the PROFINET functions don`t only depend on the firmware version of the module, but also on the adopted CPU and their firmware version.
This is described in the manual of the relevant Industrial Ethernet CP.
5)
The function is only supportd in single mode.
6)
DDEB = Direct Data Exchange Broadcast
7)
in redundant mode via both interfaces
8)
via integrated IE interface of SIMATIC PC and S7-mEC
9)
via CP 1616 or CP 1604 (integrated PROFINET interface of SIMATIC PC and S7-mEC)

This entry is from the Service&Pupport portal of Siemens AG, Siemens Industry Online Support.
Unrestricted Change date: 08/27/2022 Page: 2/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO controller support the functions IRT, prioritized startup, MRP, PROFIenergy,
s Shared device, I device, Isochronous mode and System redundancy in STEP 7 V5.x?
Entry-ID: 44383954

Isochronous Min. cycle time of System Max. number


mode isochronous mode redundancy of IO devices
interrupt OB
(Isochronous mode)

from V3.32) 1 ms −
− − − 128
from V3.22) 1 ms − 128
− − − 128
from V3.21)2) 1 ms − 128
from V3.22) 1 ms − 128
− − − 128
from V3.22) 1 ms − 128
− − − 128
from V3.21)2) 1 ms − 128
from V3.22) 1 ms − 128
from V3.21)2) 1 ms − 128
− − − 256
from V3.22) 500 µs − 256
− − − 256
from V3.21)2) 500 µs − 256

from V6.02) 1,5 ms − 256


from V7.02) 1,5 ms − 256
− − − 256
from V6.02) 1 ms − 256
from V7.02) 1 ms − 256
from V6.01)2) 1 ms − 256
from V7.02) 1 ms − 256
− − − 256
from V6.02) 1ms − 256
from V7.02) 1ms − 256
− − − 256
from V6.01)2) 1ms − 256
from V7.02) 1ms − 256
− − from V6.0 2567)
− − from V6.0 2567)
− − from V6.0 2567)
− − from V6.0 2567)

− − − 32
− − − 128
− − − 128
− − − 128
− − − 128
− − − 128
− − − 128

This entry is from the Service&Pupport portal of Siemens AG, Siemens Industry Online Support.
Unrestricted Change date: 08/27/2022 Page: 3/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO controller support the functions IRT, prioritized startup, MRP, PROFIenergy,
s Shared device, I device, Isochronous mode and System redundancy in STEP 7 V5.x?
Entry-ID: 44383954

− − − 1288)
2569)
− − − 1288)
2569)
yes3) 2,2 ms − 1288)
2569)
yes3) 2,2 ms − 1288)
2569)
yes 250 µs − 256
yes 250 µs − 256
yes 250 µs − 256
yes 250 µs − 256
yes 250 µs − 256

yes 250 µs − 128


yes 250 µs − 128
yes 250 µs − 128
yes 250 µs − 128
− − − 64

− − − 128
from V3.22) 1 ms − 128
− − − 128
from V3.21)2) 1 ms − 128

− − − 128
from V3.22) 1 ms − 128
from V3.21)2) 1 ms − 128
from V3.21)2) 1 ms − 128

This entry is from the Service&Pupport portal of Siemens AG, Siemens Industry Online Support.
Unrestricted Change date: 08/27/2022 Page: 4/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO controller support the functions IRT, prioritized startup, MRP, PROFIenergy,
s Shared device, I device, Isochronous mode and System redundancy in STEP 7 V5.5?
Entry-ID: 44383954

Module Order number IRT prioritized MRP PROFIenergy Shared device I device Isochronous mode System
startup redundancy
PC CPs
CP 1616 6GK1161-6AA01 from V2.0 from V2.2.0 from V2.2.0 from V2.5.2 from V2.5 from V2.5.2 yes −
CP 1616 6GK1161-6AA02 from V2.0 from V2.2.0 from V2.2.0 from V2.5.2 from V2.5 from V2.5.2 yes −
CP 1604 6GK1160-4AA00 from V2.0 from V2.2.0 from V2.2.0 from V2.5.2 from V2.5 from V2.5.2 yes −
CP 1604 6GK1160-4AA01 from V2.0 from V2.2.0 from V2.2.0 from V2.5.2 from V2.5 from V2.5.2 yes −
SIMATIC NET PC software
SOFTNET PROFINET IO 6GK1704-1HWxx-3AA0 − − − from V8.2 from V8.1 from V8.1 − −
S7-400 CPUs
CPU 412-2PN 6ES7412-2EK06-0AB0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.02) −
CPU 414-3PN/DP 6ES7414-3EM05-0AB0 from V5.2 from V5.2 − from V5.0 − − − −
CPU 414-3PN/DP 6ES7414-3EM06-0AB0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.02) −
CPU 414F-3PN/DP 6ES7414-3FM06-0AB0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.01)2) −
CPU 416-3PN/DP 6ES7416-3ER05-0AB0 from V5.2 from V5.2 − from V5.0 − − − −
CPU 416-3PN/DP 6ES7416-3ES06-0AB0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.02) −
CPU 416F-3PN/DP 6ES7416-3FR05-0AB0 from V5.2 from V5.2 − from V5.0 − − − −
CPU 416F-3PN/DP 6ES7416-3FS06-0AB0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.0 from V6.01)2) −
CPU 412-5H PN/DP 6ES7412-5HK06-0AB0 − − from V6.0 − from V6.05) − − from V6.0
CPU 414-5H PN/DP 6ES7414-5HM06-0AB0 − − from V6.0 − from V6.05) − − from V6.0
CPU 416-5H PN/DP 6ES7416-5HS06-0AB0 − − from V6.0 − from V6.05) − − from V6.0
CPU 417-5H PN/DP 6ES7417-5HT06-0AB0 − − from V6.0 − from V6.05) − − from V6.0
S7-300 CPUs
CPU 314C-2 PN/DP 6GK7314-6EH04-0AB0 from V3.3 from V3.3 from V3.3 from V3.3 from V3.3 from V3.3 from V3.32) −
CPU 315-2PN/DP 6ES7315-2EH13-0AB0 − − − from V2.5 − − − −
CPU 315-2PN/DP 6ES7315-2EH14-0AB0 from V3.2 from V3.2 from V3.2 from V3.1 from V3.2 from V3.2 from V3.22) −
CPU 315F-2PN/DP 6ES7315-2FH13-0AB0 − − − from V2.5 − − − −
CPU 315F-2PN/DP 6ES7315-2FJ14-0AB0 from V3.2 from V3.2 from V3.2 from V3.1 from V3.2 from V3.2 from V3.21)2) −
CPU 315T-3PN/DP 6ES7315-7TJ10-0AB0 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.22) −
CPU 317-2PN/DP 6ES7317-2EK13-0AB0 − − − from V2.5 − − − −
CPU 317-2PN/DP 6ES7317-2EK14-0AB0 from V3.2 from V3.2 from V3.2 from V3.1 from V3.2 from V3.2 from V3.22) −
CPU 317F-2PN/DP 6ES7317-2FK13-0AB0 − − − from V2.5 − − − −
CPU 317F-2PN/DP 6ES7317-2FK14-0AB0 from V3.2 from V3.2 from V3.2 from V3.1 from V3.2 from V3.2 from V3.21)2) −
CPU 317T-3PN/DP 6ES7317-7TK10-0AB0 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.22) −
CPU 317TF-3PN/DP 6ES7317-7UL10-0AB0 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.21)2) −
CPU 319-3PN/DP 6ES7318-3EL00-0AB0 from V2.7 from V2.7 − from V2.5 − − − −
CPU 319-3PN/DP 6ES7318-3EL01-0AB0 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.22) −
CPU 319F-3PN/DP 6ES7318-3FL00-0AB0 from V2.7 from V2.7 − from V2.5 − − − −
CPU 319F-3PN/DP 6ES7318-3FL01-0AB0 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.21)2) −

This entry is from the Service&Pupport portal of Siemens AG, Siemens Industry Online Support.
Unrestricted Change date: 08/27/2022 Page: 5/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO controller support the functions IRT, prioritized startup, MRP, PROFIenergy,
s Shared device, I device, Isochronous mode and System redundancy in STEP 7 V5.5?
Entry-ID: 44383954

Module Order number IRT prioritized MRP PROFIenergy Shared device I device Isochronous mode System
startup redundancy
Industrial Ethernet CPs
CP 343-1 Standard 6GK7343-1EX30-0XE0 − from V2.2 from V2.2 from V3.0 from V2.4 from V2.4 − −
CP 343-1 Advanced 6GK7343-1GX30-0XE0 from V1.0 from V1.0 from V1.0 − from V1.2 from V1.2 − −
CP 343-1 Advanced 6GK7343-1GX31-0XE0 from V3.0 from V3.0 from V3.0 from V3.0 from V3.0 from V3.0 − −
CP 443-1 Standard4) 6GK7443-1EX20-0XE0 from V2.0 from V2.0 from V2.0 from V2.1 from V2.1 − − −
CP 443-1 Standard4) 6GK7443-1EX30-0XE0 from V3.0 from V3.0 from V3.0 from V3.0 from V3.0 − − −
CP 443-1 Advanced4) 6GK7443-1GX20-0XE0 from V2.0 from V2.0 from V2.0 from V2.1 from V2.1 − − −
CP 443-1 Advanced4) 6GK7443-1GX30-0XE0 from V3.0 from V3.0 from V3.0 from V3.0 from V3.0 − − −
ET 200S
IM151-8 PN/DP CPU 6ES7151-8AB00-0AB0 from V2.7 from V2.7 − from V2.7 − − − −
IM151-8 PN/DP CPU 6ES7151-8AB01-0AB0 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.22) −
IM151-8F PN/DP CPU 6ES7151-8FB00-0AB0 from V2.7 from V2.7 − from V2.7 − − − −
IM151-8F PN/DP CPU 6ES7151-8FB01-0AB0 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.21)2) −
ET 200pro
IM 154-8 CPU 6ES7154-8AB00-0AB0 − − − from V2.5 − − − −
IM 154-8 CPU 6ES7154-8AB01-0AB0 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.22) −
IM 154-8F CPU 6ES7154-8FB01-0AB0 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.21)2) −
IM 154-8FX CPU 6ES7154-8FX00-0AB0 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.2 from V3.21)2) −
Embedded und PC-based Automation
WinAC RTX 2009 6ES7671-0RC07-0YA0 yes yes − yes − − − −
WinAC RTX F 2009 6ES7671-1RC07-0YA0 yes yes − yes − − − −
WinAC RTX 2010 6ES7671-0RC08-0YA0 yes yes yes3) yes yes − yes3) −
WinAC RTX F 2010 6ES7671-1RC08-0YA0 yes yes yes3) yes yes − yes3) −
S7-mEC EC31-RTX 6ES7677-1DD10-0BB0 yes yes yes yes yes − yes −
S7-mEC EC31-RTX F 6ES7677-1FD10-0FB0 yes yes yes yes yes − yes −
S7-mEC EC31-HMI/RTX 6ES7677-1DD10-0BF0 yes yes yes yes yes − yes −
6ES7677-1DD10-0BH0 yes yes yes yes yes − yes −
6ES7677-1DD10-0BG0 yes yes yes yes yes − yes −

1)
If you use a F-CPU as PROFINET IO-Controller, the "Failsafe" function and "Isochronous mode" function should not take place together in one IO device.
2)
The CPU supports the "Isochronous mode" function only as IO controller.
3)
The function is only supported over CP 1616 or CP 1604.
4)
With S7-400 Industrial Ethernet CPs the PROFINET functions don`t only depend on the firmware version of the module, but also on the adopted CPU and their firmware version.
This is described in the manual of the relevant Industrial Ethernet CP.
5)
The function is only supportd in single mode.

This entry is from the Service&Pupport portal of Siemens AG, Siemens Industry Online Support.
Unrestricted Change date: 08/27/2022 Page: 6/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO controller support the functions IRT, prioritized startup, MRP, PROFIenergy,
s Shared device, I device, Isochronous mode and System redundancy in STEP 7 V5.5?
Entry-ID: 44383954

Link to Product information

https://support.industry.siemens.com/cs/ww/en/pv/6GK1161-6AA02

https://support.industry.siemens.com/cs/ww/en/pv/6GK1160-4AA01

https://support.industry.siemens.com/cs/ww/en/pv/6ES7412-2EK06-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7414-3EM05-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7414-3EM06-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7414-3EM06-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7416-3ER05-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7416-3ES06-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7416-3FR05-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7416-3FS06-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7412-5HK06-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7414-5HM06-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7416-5HS06-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7417-5HT06-0AB0

https://support.industry.siemens.com/cs/ww/en/pv/6ES7314-6EH04-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7315-2EH13-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7315-2EH14-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7315-2FH13-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7315-2FJ14-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7315-7TJ10-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-2EK13-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-2EK14-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-2FK13-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-2FK13-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-7TK10-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7317-7UL10-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7318-3EL00-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7318-3EL01-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7318-3FL00-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7318-3FL01-0AB0

This entry is from the Service&Pupport portal of Siemens AG, Siemens Industry Online Support.
Unrestricted Change date: 08/27/2022 Page: 7/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO controller support the functions IRT, prioritized startup, MRP, PROFIenergy,
s Shared device, I device, Isochronous mode and System redundancy in STEP 7 V5.5?
Entry-ID: 44383954

Link to Product information

https://support.industry.siemens.com/cs/ww/en/pv/6GK7343-1EX30-0XE0
https://support.industry.siemens.com/cs/ww/en/pv/6GK7343-1GX30-0XE0
https://support.industry.siemens.com/cs/ww/en/pv/6GK7343-1GX31-0XE0
https://support.industry.siemens.com/cs/ww/en/pv/6GK7443-1EX20-0XE0
https://support.industry.siemens.com/cs/ww/en/pv/6GK7443-1EX30-0XE0
https://support.industry.siemens.com/cs/ww/en/pv/6GK7443-1GX20-0XE0
https://support.industry.siemens.com/cs/ww/en/pv/6GK7443-1GX30-0XE0

https://support.industry.siemens.com/cs/ww/en/pv/6ES7151-8AB00-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7151-8AB01-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7151-8FB00-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7151-8FB01-0AB0

https://support.industry.siemens.com/cs/ww/en/pv/6ES7154-8AB00-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7154-8AB01-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7154-8FB01-0AB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7154-8FX00-0AB0

https://support.industry.siemens.com/cs/ww/en/pv/6ES7671-0RC07-0YA0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7671-1RC07-0YA0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7671-0RC08-0YA0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7671-1RC08-0YA0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7677-1DD10-0BB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7677-1FD10-0FB0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7677-1DD10-0BF0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7677-1DD10-0BH0
https://support.industry.siemens.com/cs/ww/en/pv/6ES7677-1DD10-0BG0

ersion.

This entry is from the Service&Pupport portal of Siemens AG, Siemens Industry Online Support.
Unrestricted Change date: 08/27/2022 Page: 8/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.