You are on page 1of 2
Subject: Analysis & Design of ‘Technical Engineering College / Mosul Reinforced Concrete Structures (4) wry Department of Building & Class: 4 Construction Tech. Eng. Time: 3 Hours Date: 14/7/2020 Final Examination (2019-2020) Note: Answer only Four questions (Qi: Choose the correct answer for FIVE: 1. According to ACI limitations the minimum reinforcement ratio for column is a. 0.04 6.0.01 ¢.0.08 — d.0.75pb 2. According to ACI limitations the maximum reinforcement ratio for column is: a. 0.04 b.001 008 —d.0.75pb 3. Flat plates are used for: A: small spans and heavy loads _ B: Small spans and small loads C: Large spans and heavy loads _D: Large spans and small loads 4, Ina one way slab 150 mm thick, for f y = 412 MPa, the minimum reinforcement area is: A: No. 10@ 280mm — B: No. 10 @ 320mm —C: No.12 @ 300 mm No, 12@ 250mm, 5. Ina flat slab of panel dimensions 6x8 m, the maximum allowable dimensions of opening at intersection of middle strips are: A:3x3m=—B: 1.5x1.Sm —C:2x4m Ds 3x5m 6. Yield lines must pass through: ‘A: Intersection of rotation axis B: Column locations C: Simple supports D: Allof A, Band C. Q2: For the 180mm thick flat plate interior panel shown below, the applied service live load is 6.0 kN/m? Show that slab thickness is not adequate for punching shear resistance without using shear reinforcement. Also show that slab thickness must be increased even if shear reinforcement is used. Column dimensions are 400x400mm, uniform spacing between columns is 8m in long direction and 6m in short direction. 25 MPa. k-— 8m ——->| (Q3: Using the direct design method, Find the (-ve) and (+ve) beam moments of beam BI shown in figure below, if the ultimate uniform load on slab (Ws) is 15 KN/m?, All columns are of dimensions of 400x400 mm o4m Section A-A ‘G4: Design only the spacing of the spiral ties for a circular column has diameter 350 mm. Assume the concrete cover is 40 mm and the spiral bar is No.10. If, f'=25 MPa & fy=400 MPa. Q5: The square reinforced concrete slab (4.54.5) m as shown in Fig. below. It is simply supported at its left and right edges, fully fixed at its bottom edge, and free of support along the top side. Reinforcement provides design strength Mn = 26 KN.m/m in positive bending and gMn= 39 KN.m/m in negative bending at the right edge. Using the equilibrium method, find the factored load ‘Wu uniformly distributed over the surface that would cause flexural failure. Subject Lecturer Head of Department Dr. Hasan M. Ahmed Dr. Nabeel Kh. Ismael

You might also like