Professional Documents
Culture Documents
FT Series
SERIES
Temperature,
Small Spot Mid to Low
FT-H10 Temperature, Mid to Low
Mid-Range Mid to Low High Temperature,
Temperature,
Ultra Long-Range
FT-H20 Long-Range Temperature,
FT-H30 Ultra Long-Range High Temperature, FT-H50K
FT-H50 Mid-Range
FT-H40K
New High
Temperature Sensors
View the surface temperature with non-contact technology.
New high-temperature and ultra long-range models have been added
to the lineup of FT Series Digital Infrared Temperature Sensors
Sensor head
Sensor head
Mid to Low Temperature, Mid to Low Temperature, Mid to Low Temperature, Mid to Low Temperature,
Ultra Long-Range Long-Range Mid-Range Small-Spot
FT-H50 FT-H30 FT-H20 FT-H10
2
Amplifier Unit
FT-50AW
(DIN rail mounting type)
2732°F
(1500°C)
Suitable for a wide range of applications
1832°F
(1000°C)
Forging 392 to 2372°F
(200 to 1300°C)
932°F
(500°C)
Glass Forming 842 to 2192°F
(450 to 1200°C)
32°F(0°C)
(50 to 150°C)
3
Temperature Management Applications
ast ser
Fastest in its class*
15-ms high-speed response Laser pointer
KEYENCE has significantly increased the responsiveness of Two laser pointers* clearly indicate the detection range
the thermopile that detects temperatures in the FT Series by: making sensor installation simple.
1. Thinning a far-infrared resonance film to the minimum
thickness.
2. Positioning thermocouples in a geometrically efficient
way and detecting the absorbed heat quickly and
accurately.
Far-infrared
resonance film
Thermocouple
Thermopile chip of
approx. 0.6 mm x 0.6 mm
0.02" x 0.02"
mm
0.6.02"
0
* The typical response speed is 10 ms and the highest response speed is 15 ms. * Class 1 Laser Product
(IEC60825-1, FDA (CDRH) Part1040.10)
6
mall igh stability
Conventional sensor
FT Series
FT Series
The FT Series displays stable temperatures under varying
conditions.
* If the Analog Monitor Output function or the Timing function is used, up to two banks can be used. If both functions are used, only one bank can be used.
7
Step1 Step2 Step3
How to select an Select a sensor head Select an amplifier Select any additional
FT Series sensor based on temperature range
and measuring distance
based on mounting
type
options
1 Select by temperature
FT-H50K/FT-H40K FT-H50/FT-H30/FT-H20/FT-H10
2 Select by distance
FT-H10 FT-H20 FT-H30
Distance between Distance between Distance between
21 0.83" 10.5 0.41" 0 0 10.5 0.41" laser spots (example) 24.5 0.96" 13 0.51" 8 0.31" 17 0.67" laser spots (example) 25.5 1.00" 17 0.67" 22 0.87" 35.5 1.40" laser spots (example)
ø11 ø0.43" ø6.3 ø0.25" ø1.5 ø0.06" ø8 ø0.31" View width (mm inch) ø11 ø0.43" ø8.5 ø0.33" ø6 ø0.24" ø14.5 ø0.57" View width (mm inch) ø11 ø0.43" ø15 ø0.59" ø18 ø0.71" ø33 ø1.30 View width (mm inch)
Laser pointer
Laser pointer
Measurement
area
Object
00 17.5 0.69" 35 1.38" 52.5 2.07" Detecting distance (mm inch) 00 60 2.36" 120 4.72" 180 7.09" Detecting distance (mm inch) 00 200 7.87" 400 15.75" 600 23.62" Detecting distance (mm inch)
View width
Distance between
laser pointers
For the FT-H20 and FT-H30 models, the laser pointers appear to rotate clockwise as they travel farther from the source,
as shown in the drawing above.
FT-H40K FT-H50/FT-H50K
26 1.02" 26 1.02" 26 1.02" 26 1.02" 26 1.02" Distance between laser spots (example) 26 1.02" 26 1.02" 26 1.02" 26 1.02" 26 1.02" 26 1.02" Distance between laser spots (example)
ø11 ø0.43" ø7.5 ø0.30" ø6 ø0.24 ø4 ø0.16" ø11.5 View width (mm inch) ø11 ø0.43" ø18 ø0.71" ø25 ø0.98" ø30 ø1.18" ø45 ø1.77" ø75 ø2.95" View width (mm inch)
ø0.45"
00 100 3.94" 150 5.91" 200 7.87" 300 11.81" Detecting distance (mm inch) 00 500 19.69" 1000 39.37" 1500 59.06" 2000 78.74" 3000 118.11" Detecting distance (mm inch)
Sensor head
Model Shape Type Detectable temperature Measuring distance/ View diameter (example)
FT-H20 Mid to low Mid-range 32 to 932˚F 60/ø8.5mm 2.36"/ø0.33" 120/ø6mm 4.72"/ø0.24" 180/ø14.5mm 7.09"/ø0.57"
FT-H30 temperature Long-range (0 to 500˚C) 200/ø15mm 7.78"/ø0.59" 400/ø18mm 15.75"/ø0.71" 600/ø33mm 23.62"/ø1.30"
8
Step2 Select amplifier based on mounting type
Amplifier units
Model Form Type Output type
FT-50AW NPN
DIN rail mount
FT-50AWP PNP
FT-55AW NPN
Panel mount
FT-55AWP PNP
included with
AR
ED
TH
ER
MO
SE
NSO
R
FT-S1 or FT-S2
OUT1
POWER
OUT2
FT-H50K
Cover
Tube fitting
Cap
Option
Model FT-S1 FT-S2 OP-84289 OP-91147 OP-76877 OP-51476 OP-42367 OP-82488
Robust box with Germanium window DIN amplifier Panel mount Head connection
Item name air purge for robust box Ferrite core Black-body tape mounting bracket bracket set connectors (2 pieces) Power cable
Shape
Weight Approx. 700 g Approx. 32 g Approx. 65 g Approx. 145g Approx. 13 g Approx. 7 g Approx. 3 g Approx. 55 g
9
Specifications
Sensor heads
Mid to low temperature High temperature
Type
Small-spot Mid-range Long-range Ultra long-range Mid-range Ultra long-range
Model FT-H10 FT-H20 FT-H30 FT-H50 FT-H40K FT-H50K
Rated temperature range *1 32 to 932°F (0 to 500°C) 32 to 2462°F (0 to 1350°C)
Displayable temperature range -58 to +968°F (-50 to +520°C) -58 to 2552°F (-50 to +1400°C)°C
Detecting distance Unlimited *2
17.5/ø6.3 mm 0.69"/ø0.25" 60/ø8.5 mm 2.36"/ø0.33" 200/ø15 mm 7.87"/ø0.59" 500/ø18 mm 19.69"/ø0.71" 100/ø7.5 mm 3.94"/ø0.30" 500/ø18 mm 15.69"/ø0.71"
Measuring distance /
35/ø1.5 mm 1.38"/ø0.06" 120/ø6 mm 4.72"/ø0.24" 400/ø18 mm 15.75"/ø0.71" 1500/ø30 mm 59.06"/ø1.18" 150/ø6 mm 5.91"/ø0.24" 1500/ø30 mm 59.06"/ø1.18"
View diameter (example)
52.5/ø8 mm 2.07"/ø0.31" 180/ø14.5 mm 7.09"/ø0.57" 600/ø33 mm 23.62"/ø1.30" 3000/ø75 mm 118.11"/ø2.95" 300/ø11.5 mm 11.81"/ø0.45" 3000/ø75 mm 118.11"/ø2.95"
Sight *3 2-point visible laser beam
Detecting element Thermopile
Detecting wavelength 8 to 14 μm
Repeatability ±0.9°F (±0.5°C) ±5.4°F (±3°C)
Emissivity (ε) correction 0.10 to 1.99 (0.01 step)
Ambient temperature 14 to 131°F (-10 to 55°C), No freezing
Environmental Ambient humidity 35 to 85%, No condensation
resistance
Vibration resistance 10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z axis directions
Shock resistance 500 m/s2, 10 times in each direction of each axis (X, Y, Z), 60 times in total
Case: Reinforced glass plastic, Infrared collector lens: Germanium, Laser transmitter: Polyarylate
Material
Lens tube*4: Aluminum, Cable: Vinyl chloride, Mounting bracket: SUS304, Mounting screw: Stainless steel
Weight Approx. 120g Approx. 150g
Accessory Mounting bracket
*1 Repeatability is guaranteed within the rated temperature range.
*2 Place at a distance so that object appears 1.5 times larger than the view diameter.
*3 Visible semiconductor laser beam wavelength 655 nm, Class 1 Laser Product (IEC60825-1, FDA (CDRH) Part1040.10). The laser classification for FDA (CDRH) is implemented based on IEC 60825-1
in accordance with the requirements of Laser Notice No.50.
*4 No lens tube on models FT-H10, FT-H20, and FT-H30.
Amplifiers
Type DIN-rail mounting type Panel mounting type
NPN FT-50AW FT-55AW
Model
PNP FT-50AWP FT-55AWP
Power voltage 12 to 24 VDC, Ripple (P-P)10% max.
Power Normal 1400 mW (For 12 V), 1600 mW (For 24 V)
consumption Eco mode 1150 mW (For 12 V), 1350 mW (For 24 V)
4 + 1/two-digit 7-segment LED, dual-display (red/green) display (character height in the upper display (red): 8 mm 0.31",
Display method
character height in the lower display (green): 5.7 mm 0.22"), Display updating cycle: 10/s
Operation indicator Red LED x 3 (control output1/control output2/timing input indicator)
Display resolution 0.2°F or 1.8°F (0.1°C or 1°C) (when using H10/H20/H30), 1.8°F (1°C) (when using H50/H40K/H50K)
Hysteresis Variable
Response speed HSP, 30, 100, 200, 500, 1000, or 5000 ms can be selected (In HSP: 15 ms max.)
Bank selection Pink and Purple wires can be configured for Bank Inputs #1,2 respectively for up to 4 total banks.
Bank specifications Emissivity (valid in temperature mode) and limit settings x 2 can be set for each bank.
External Timing input Input time: 2 ms min.
input Bank input Input time: 20 ms min.
Control output NPN (PNP) open collector x 2 channels (N.O./N.C. selectable), 100 mA (50 mA) max. (40 VDC (30 VDC) max.), residual voltage: 1 V max.
Analog output 4 to 20 mA, maximum load resistance: 260 Ω The upper- and lower-limit values of the analog output range can be set optionally.
Ambient temperature -14 to +122°F (-10 to +50°C), No freezing
Environmental
resistance*1 Ambient humidity 35 to 85%, No condensation
Vibration resistance 10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z axis directions
Main unit Main unit, Cover: Polycarbonate, Keycaps: Polyester elastomer, Cable: Vinyl chloride
Material
Mounting bracket SUS304 Panel mounting bracket: Polyacetal, front protection cover: Polycarbonate
Weight Approx. 85g
Accessory DIN anchoring fixture, power cable, unit cover sticker Panel mounting bracket, protection cover, power cable, unit cover sticker
*1 Ambient temperature when using the analog output is 14 to 113°F (-10 to 45°C) .
Robust box with air purge Germanium window for robust box Black-body tape
Model FT-S1 Model FT-S2 Model OP-91147
Recommended Infrared Emissivity 0.95
flow rate 15ℓ/min 85% or more
transmissivity*
Air Allowable
supply 356°F (180°C)
Cap: aluminum, lens: germanium, temperature limit
Withstanding
pressure 1 MPa or less (at inlet) Material
O-ring: NBR Width: 50 mm 1.97",
Size
Conforming tube diameter ø6 mm 0.24" Weight Approx. 32 g length: 10 m 32.81'
Housing: zinc, cap: aluminum, * Infrared transmissivity for wavelength of 8 to 14 µm. Weight Approx. 145 g
Material cable packing and O-ring: NBR,
fitting: Brass nickel-plated
Weight Approx. 700 g
* FT-S1 does not provide cooling.
10
Input / Output Circuits
Black (4 to 20 mA)
circuit
Overcurrent
Main
(Control output 1)
Load 5 to 40 VDC
Main circuit
White Blue
Pink/Purple 0V
(Control output 2)
Main circuit
Load 5 to 40 VDC
Blue
0V Blue
Bank input 1/
Input/output Pink analog output/selectable
circuits 1 (Short circuit current 1 mA max.)
Bank input 2/
Purple timing input/selectable
Input circuits 2
White
Main circuit
(Control output 2) Pink Analog output
Main circuit
circuit
Main
Load Purple
Blue Blue
0V 0V
Input/output Pink Bank input 1/
circuits 1 analog output/selectable
(Short circuit current 2 mA max.)
Purple Bank input 2/
Input circuits 2 timing input/selectable
11
Unit: mm inch
Dimensions
Sensor heads FT-H10/20/30 41.6 1.64"
1.22"
ø0.14" 0.18" 31.1 0.18"
ø3.6 (4-core x 0.18 mm2)
Mounting bracket 4.5 0.52" 4.5
Cable length: 3 m 9.8'
(accessory) 13.1
0.18"
4.5
0.31"
19.6 17.6 0.31" 8 8
0.77" 0.69"
0.31" 7.8 7.8
0.31"
0.35"
8.8 1.14"
56.7 2.23" 0.15" 29
20
0.79" 0.11" 2.7 3.8
°
20 48 1.89"
Center of the
detection zone
ø11 9 0.35" 2 x M3 screw
20°
ø0.43"
29 0.26" 27.6
X 35 6.5 1.09" 6-
1.38" 1.14" 29 R
1.14" 1.
8
R
65.8 0.
.14 07 29
29 14"
2.59" ø03.5 " 1.14"
1.
17 2-ø 35
X=21 0.83" (FT-H10) 0.67" 1.38"
24.5 0.94" (FT-H20) Center of emitted light * Head connection connector OP-42367 is
attached to end of head cable.
25.5 1.00" (FT-H30) 6
0.24" SUS304
10° 25° t=1.5 0.06"
20.8
0.82"
* Includes two M3 screws, length: 30 mm 1.18" (stainless steel)
SUS304
t=2.0 0.08"
Horizontal mounting Vertical mounting When installed at 45 degrees
30.8 30.8
30.8 1.21" 1.21"
1.21" 21.8 21.8 21.8
0.86" 0.86" 0.86"
41.6 1.64"
0.72"
18.3 57 2.24"
0.38"
9.6 5.9 0.23"
10.7
0.42" 6.2 0.24"
65.8
2.59"
76.5 72
42.3 3.01" 2.83"
1.67" 24.8
0.98"
20
0.43" 10.9 0.79" 11.8
0.46"
52.5 2.07"
9.5
0.37"
41.6 1.64"
1.22"
Mounting bracket 31.1
ø0.14"
(accessory) 0.18" 4.5 0.52" 4.5 0.18"
13.1
ø3.6 (4-core x 0.18 mm2) 0.31" 0.31" 0.18"
8 8 4.5
Cable length: 3 m 9.8'
19.6 ø17.6
0.77" ø0.69"
7.8 7.8
0.31" 0.31"
91.7 3.61" 1.14" 20°
0.79" 0.35" 8.8 29
20 0.11" 2.7 48 1.89" 0.35" 3.8 0.15"
Center of the 9
detection zone
ø11 ø0.43" 2 x M3 screw
27.6 20°
35 1.09"
26.2 1.38" ø15 0.26"
1.03" 29 ø0.59" 6.5 29
1.14" 1.14"
65.8 6 x R1.8 29
2.59" R0.07" 1.14"
37.7 17 2xø3.5 29 35
2xø3.2 ø0.13" ø0.14" 1.14" 1.38"
1.48" 0.67"
54.7 2.15"
* Head connection connector OP-42367 is
Center of emitted light attached to end of head cable. 6 0.24"
SUS304
20.8 25° t=1.5 0.06"
0.82" 10°
SUS304
t=2.0 0.08" * Includes two M3 screws, length: 30 mm 1.18" (stainless steel)
41.6 1.64"
0.72"
18.3 77.3 3.04"
5.2 0.20"
111.5 92.3
3.63"
4.39"
45.9 1.81"
87.5 3.44"
11.8 0.46"
20
0.79"
29.8
1.17"
12
Digital amplifier FT-50AW(P) DIN-rail mounting When the mounting bracket is attached
24
0.94"
12.9 10.5 0.41" (41.3)
0.51" (1.63")
5 0.20" 19.5
0.77"
77.1
0.45" Mounting bracket OP-76877(accessory)
SUS304
(R
(R 9")
0
")
15
.5
(R 5)
33.2
59
(38.2)1.31"
1
)
0.
(R
22
(1.50") 0.87"
15.2
0.60" 11.4
0.45" 15
4.2 0.59" 2-(4.4 x 3.4)
0.17" 35.4 1.39" 26.6 1.05" (0.17" x 0.13")
15.7 49.3 1.94" 18.5
0.62" 0.73"
(R
(R ")
")
0.
59
59
15
24
(R 5)
24.7 0.97"
0.
1
)
0.94"
(R
12.9 0.51" 10.5 0.41" 11.3 7.4
0.44 "
0.29"
Panel mounting bracket (Panel mounting bracket, Front protection cover) OP-51476 Power cable OP-82488
(included with FT-55AW(P)) Panel mounting bracket Front protection (included with FT-50AW(P)/FT-55AW(P))
cover (accessory) Panel cutout
23.5
0.93"
7.5
0.30"
49 1.93"
X X=24 x (A-1)+21
When A FT-55AWs are installed
24.3 23.8
0.96" 0.96" close to each other
50 1.97"
When the panel is attached
45 1.77"
73 max. 1.05"
83.1 3.27" 18.1
0.71"
26.6 max.
1.05" 21+0.4 ø0.15"
0 ø3.9 (6-core x 0.13 mm2)
0.83" +0.02
0 0.36" 24.8
9.1 0.98" Cable length: 2 m 6.6'
7.6 0.30"
45 1.77"
Panel thickness : 1 to 6 mm 0.04" to 0.24"
39 ø30
1.54" ø1.18"
34 ø13
1.34" ø0.51"
86
56.5 3.39"
2.22" 45.5
34.5 1.79"
1.36" 20
0.79"
32
1.26"
129
5.08"
13
Related Products
I P 67
CALL T O C O N TA C T Y O U R L O C A L O F F I C E
TOLL
FREE
1-888-KEYENCE
1 - 8 8 8 - 5 3 9 - 3 6 2 3
www.keyence.com SAFETY INFORMATION
Please read the instruction manual carefully in
order to safely operate any KEYENCE product.
The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice. KA1-1017
Company and product names mentioned in this catalog are either trademarks or registered trademarks of their respective companies.
The specifications are expressed in metric units. The English units have been converted from the original metric units.
Copyright © 2009 KEYENCE CORPORATION. All rights reserved. FT-KA-C-GB 1128-9 611170