Certified to PLe
Introduction to Fortress:
Fortress designs and manufactures customised safety equipment, protecting lives in hazardous workplaces. Our
reputation is as a global provider of robust safety specifications for manufacturing environments.
Why Interlocks? Interlocking is a method of controlling two or more interdependent operations which must take place
in a predetermined sequence, if necessary remotely controlled or time delayed. The need for this sequence may be
safety to personnel and equipment, or it may be to control processes and productivity.
Over the last 40 years, Fortress has become well known in the industry for innovative design, robust engineering and
reliability. Headquarters are in Wolverhampton (UK), with supporting offices and manufacturing facilities in the USA,
Netherlands, Australia and China, further supported by a global network of trusted distributors and channel partners.
mGard - The only range of mechanical interlocks independently certified to PLe
amGardpro - Heavy duty safety gate switches with connectivity and trapped key integration certified to PLe
amGardS40 - Stainless steel IP69K safety gate switches independently certified to PLe
tGard - Medium duty interlocks with configurable built-in control functionality independently certified to PLd
error
2
Introduction to
Why Interlocks?
Interlocking is a method of controlling two or more interdependent operations which must take place in a predetermined
sequence, if necessary remotely controlled or time delayed. The need for this sequence may be safety to personnel and
equipment, or it may be to control processes and productivity.
For Reference-
- ISO 14119 is the interlocking standard that forms part of the machinery directive.
Why Mechanical?
- One power isolator can be used for multiple doors through the use of a key exchange unit.
- This reduces any fault masking risks and wiring installation required.
- In addition mechanical interlocking is the only method of safeguarding solutions for multiple energy sources.
- Personnel keys can be used to prevent unexpected start up of machinery as per ISO 14118, removing the
necessity for escape functions.
mGard is the only range of trapped key interlocks 3rd party approved as being capable of
meeting PLe and is perfect for heavy duty applications. Fortress’ mGard is suitable for use
up to SIL3 (EN/IEC 62061), Category 4 and PLe
(EN/ISO 13849-1).
3
Robot Welding Cell FlexArc Robot Welding Cell
Fortress Application Example: Power Interlocking
Application Requirement:
icationThis robot welding cell's safety system must only allow operators to enter the cells when power to the cell has been
Requirement:
isolated and the machinery has come to a controlled stop after a defined run-down time. After access, the system
prevents unexpected
containedstart up when multiple operatorsby
are performing maintenance, via Personnel Keys.
ing cells are a self system of robots safeguarded a mechanical interlocking system. FlexArc Robot Welding Cell
The safety system
allow operators to enter the cell only when power to the cell has been isolated and when the machinery has come to
ntrolled stop.
Application Requirement:
*
Welding cells are a self contained system of robots safeguarded by a mechanical interlocking system. The safety system
must allow operators to enter the cell only when power to the cell has been isolated and when the machinery has come to
a controlled stop.
*
Solenoid-controlled switch Access Lock no.1
Key removed, switching elements open (machine off) Access key trapped, Personnel keys removed, Access door open
Request to enter
button pressed *
Solenoid
www.fortressinterlocks.com 4
4
Concrete Mixer
Concrete Mixer
Fortress Application Example: Power Interlocking
Application Requirement:
Industrial concrete mixers have multiple access hatches that are safeguarded by mechanical interlocks. These access
Application
hatches are Requirement:
opened for scheduled cleaning under the protection of the installed safety system. Access is only allowed
Anonce
industrial concrete
the power mixer
switch is mixer
to the used in a cement
has manufacturing
been mechanically plant to mix recently formed cement with other ingredients
isolated.
like aggregates, admixtures, fibres, and water to form a ready-mix concrete. Operators require Concrete Mixer
access into the mixer via
the hatch doors to clean the mixer at regular intervals to make sure the mixer runs at optimal efficiency. However, the
access hatches must be locked to ensure entry can only be achieved once power to the mixer has been isolated.
Application Requirement:
*
An industrial concrete mixer is used in a cement manufacturing plant to mix recently formed cement with other ingredients
like aggregates, admixtures, fibres, and water to form a ready-mix concrete. Operators require access into the mixer via
the hatch doors to clean the mixer at regular intervals to make sure the mixer runs at optimal efficiency. However, the
access hatches must be locked to ensure entry can only be achieved once power to the mixer has been isolated.
Bolt lock Access Lock no.1 Access Lock no.2 Access Lock no.3
Key removed, bolt extended, Key removed, actuator locked Key trapped, actuator removed Key removed, actuator locked
contacts open (machine off)
Concrete mixer is
operational
Concrete mixer is
operational
*
*
Bolt Module
Bolt Module unit unit MechanicalDoor
Mechanical Doorlock
lock
www.fortressinterlocks.com 3
www.fortressinterlocks.com 3
5
Double Backer
Double Backer
Fortress Application Example: Power Interlocking
Application Requirement:
Application Requirement:
The double backer machines enclosed in two cells requires extensive safeguarding. A safety system for the cells should
The double backer machine enclosed in a cell requires extensive safe guarding. A safety system for the cell should ensure
ensure operators and maintenance personnel can only enter the areas once power to all of the Double
operators and maintenance personnel can only enter the area once power to all the machinery has
machinery Backer
has been
been isolated and has
isolated and has come to
come to a controlled stop. a controlled stop.
Application Requirement:
*
The double backer machine enclosed in a cell requires extensive safe guarding. A safety system for the cell should ensure
operators and maintenance personnel can only enter the area once power to all the machinery has been isolated and has
come to a controlled stop.
*
Time delay device Key exchange device Access Lock with Personnel key Access Lock with Personnel key
no.1 no.2
Key removed, Isolation key trapped,
switching elements open (machine off). Access keys removed. Access key trapped, Access key trapped,
Personnel key removed, Personnel key removed,
Access door open. Access door open.
Voltage Sensing Unit Access lock with personnel keys Isolation Key removed Extracted Key function forces
operators to carry a Safety Key
after run-down time
while working in the cell
www.fortressinterlocks.com 6
6
Valves & Specials
Valve Application 2
Key Exchange
Valve Interlock Valve Interlock
B B C
A A C
Valve Application 1 Valve Interlock Key Exchange
Valve Interlock Valve Interlock
TANK 1 A A TANK 2 In this application, at least one pressure release line must be open
at all times. The use of the Valve Interlocks insures at least one line
Valve Interlock will always be open because the independent interlocks A and B
require their corresponding key to be turned to the locked position to
close the valve. The two Key Exchange Interlocks share one key for
the two locks marked C. The key for the two C locks is transferred
In this application, only one of the tanks can feed into the supply at once. The between the units to always trap either the A or B key.
use of Valve Interlocks insures only one of the lines can be open because the
two interlocks share a single key. Each valve can only be opened while a key
is trapped to the locked position in the interlock.
Fortress has also helped customers create completely custom units that were specific to one individual application. These
units were created in collaboration with engineers between both parties to better understand the needs and constraints of
the application. Fortress is pleased to offer advice and assist without obligation; although a more simple solution may be
proposed through standard mGard units or the other ranges Fortress has to offer.
7
Range Card
Power Isolation
Control Interlocking Power Interlocking
Panel Mounted Panel Mounted Weatherproof In Enclosure
Key Switch(es) Knob Operated Switch Control Unit Mechanical Bolt Interlock Bolt Interlock with Limit Switch
Mini Solenoid Controlled Key Switch(es) Key Operated Switch Control Unit Bolt Interlock with Switch Circuit Breakers
Solenoid Controlled Key Switch(es) Electronic Time Delay Unit Valve & Pneumatic Interlocks
ATEX Solenoid Controlled Key Switch ATEX Key Switch Voltage Sensing Unit
Key Exchange Keys & Locks Accessories
Modular Key Exchange Unit Modular Key Unit with Switch(es) Standard Masterable Extension Module
Colours available
for key bow and
dustcovers.
Lockout Hasps (For 3x Padlocks)
Low Profile
Actuators
Fixed Actuator Handle Operated Actuator Spring Released Handle Compressible Actuator Self Aligning
Operated Actuator Actuator
8-9
Power Isolation: Power Interlocking Bolt Module Unit
Blank
1-5 Total Locks for BMS (Stainless Steel) B All Keys Free Bolt Shot (BM2+)
The
The sum Secondary C All Keys Free Bolt Withdrawn (BM2+)
1-10 Total Locks for BM
of Primary and Keys positioning
Secondary keys is dependent of Leave Blank for BM, BMS, BML or BMSL
should equal the the chosen Key
0-10 Number of Primary Keys
total number of Sequencing for
keys the Bolt Module 02022 20Amp 2xNO 2xNC Switch, BMR or BMSR Only
Primary Unit
0-10 Number of Secondary Keys
Keys directly
02040 20Amp 4xNO Switch, BMR or BMSR Only
affect the
positioning of Other switches available upon request
CL Standard Lock
the bolt
ML Master Lock 006-022 Standard, Bolt Length of 6mm (Retracted)
SS Stainless Steel with Dustcover, BMS Body Only 050-066 Bolt Length of 50mm (Retracted)
SL Stainless Steel with Padlockable Dustcover, BMS Body Only 150-166 Bolt Length of 150mm (Retracted)
MP Mounting Plate
Blank
squares
and additional
"-" should be
removed from
the final part
BM - - - - - - - number
10
Power Isolation: Control Interlocking KeyOperatedSwitch
S Unit
CL Standard Lock
ML Master Lock
IN No Dustcover (Standard)
IS Dustcover
IL Padlockable Dustcover
Larger
A02022 20Amp 2xNO 2xNC Switch switches will
be in a larger
A02040 20Amp 4xNO Switch enclosure
Other switches available upon request
EM Metal Enclosure
Blank
squares
and additional
"-" should be
removed from
S - - -
the final part
number
11
Power Isolation: Control Interlocking Solenoid Controlled Key Switch
SS1-B
SS1-WP SS1-F
Add-on lock
modules are fitted to
the solenoid if multiple
keys are released by
the solenoid
The sum
of Primary and
Secondary keys
should equal the
SS Solenoid Controlled Key Switch total number of
keys A Switch Only on Solenoid Lock V Locks Arranged Vertically
1-10 Total Number of Locks
B Switch on Solenoid Lock & First Add-on Lock 01 1 Row
Number of Keys Freed when Solenoid 02022 20Amp 2xNO 2xNC Switch C Cam Sequence
1-10 is Energized (Primary)
02040 20Amp 4xNO Switch B Back of Board Mounting
Number of Keys Trapped when
0-9 Solenoid is Energised (Secondary) Other switches available upon request WP Weather (IP67) Proof Back of Board Mounting
Blank
squares
and additional
"-" should be
removed from
the final part
number
SS - - - - - PU - V 01 C
12
Power Isolation: Control Interlocking Mini Solenoid Controlled Key Switch
MSS Unit MSS-EM Unit
MSS Solenoid Controlled Key Switch
The contact
1 One Key Freed when Solenoid is Energized block in the Mini
Solenoid Controlled
Key Switch are only
0 Zero Keys Trapped when Solenoid is Energized
available as a 3Amp
2xNC Switch
CL Standard Lock
ML Master Lock
MSS-WP Unit
IN No Dustcover (Standard)
IS Dustcover
IL Padlockable Dustcover
A AC
D DC
Blank
squares
and additional
"-" should be
removed from
13
Power Isolation: Control Interlocking Time Delay and Voltage Sensing
VS Unit
CL Standard Lock
ML Master Lock
IN No Dustcover (Standard)
IS Dustcover TD Unit
IL Padlockable Dustcover
PU Power-to-Unlock Solenoid
30-300 30-300 Seconds (5 minutes) Adjustable Timer Delay, 110 / 230v Only
60-600 60-600 Seconds (10 minutes) Adjustable Timer Delay, 24v Only
Blank
squares
and additional
"-" should be
removed from
- - PU -
the final part
number
14
Power Isolation: Control Interlocking Solenoid Controlled Key Switch
SCU1-B Unit LCU4-B Unit
Blank
squares
and additional
"-" should be
removed from
the final part
- - - - - number
15
Intermediate Transfer Key Exchange Units
XM2 Unit
XMR2 Unit XML2 Unit
XMA Unit
Additional
Modules Fitted
when multiple
locks are
selected
On L versions
the switch is 2NC
1NO positive
break
Blank IS Dustcover
R Switch Contact Block Mounted to back of Primary Lock Primary Keys IL Padlockable Dustcover
are inserted
L 24v Limit Switch Mounted to the Bottom of the Unit into an XM unit SS Stainless Steel with Dustcover, XMS Body Only
to release
2-5 Total Locks for XMS (Stainless Steel) Secondary Keys SL Stainless Steel with Padlockable Dustcover, XMS Body Only
Blank
squares
and additional
"-" should be
removed from
XM - - - - -
the final part
number
16
Access Control DoorLocks
DM1 DMS1 DMSK1
DM Door Module
MP Mounting Plate
Blank squares
and additional "-"
should be removed
from the final part
number
DM - - - - - -
17
Keys and Accessories
CLK-SUSS
CLK Standard Key
SU Uni Directional
S Standard Cut
- SU -
18
Keys and Accessories
Part Number Part Number Part Number Part Number Part Number
CLDC PLDC LOS3 LOS3C M-BOB
XMA-CLIS: Mazak Body, Dustcover XMSA-CLSL: Stainless Steel Body, Padlockable Dustcover
19
Mechanical Trapped Key Interlocks
Certified to PLe