Core Loss
Grade

Thickness Assumed
Resistivity
mm
Density
-cm
(in.)
kg/dm 3

Watts per kilogram

Watts per pound

50Hz

50Hz

60Hz

Magnetic Flux Density


T

60Hz

1.0T 1.5T 1.0T 1.5T 1.0T 1.5T 1.0T 1.5T B10 B25 B50 B100
35JN200

7.60

59

0.85 1.98 1.05 2.50 0.39 0.90 0.48 1.13 1.46 1.54 1.64 1.76

35JN210

7.60

59

0.85 2.05 1.05 2.55 0.39 0.93 0.48 1.16 1.47 1.57 1.65 1.77

35JN230

7.60

55

0.89 2.10 1.10 2.60 0.40 0.95 0.50 1.18 1.47 1.57 1.66 1.78

35JN250

7.60

54

0.93 2.25 1.20 2.75 0.42 1.02 0.54 1.25 1.48 1.57 1.66 1.78

7.65

54

1.00 2.40 1.25 2.95 0.45 1.09 0.57 1.34 1.48 1.58 1.67 1.79

35JN300

7.65

51

1.10 2.60 1.40 3.20 0.50 1.18 0.64 1.45 1.50 1.59 1.68 1.80

35JN360

7.65

47

1.25 2.95 1.60 3.60 0.57 1.34 0.73 1.63 1.51 1.61 1.69 1.81

35JN440

7.70

38

1.45 3.40 1.77 4.23 0.66 1.54 0.80 1.92 1.53 1.62 1.71 1.82

50JN230

7.60

59

0.95 2.25 1.22 2.93 0.43 1.02 0.55 1.33 1.48 1.57 1.66 1.78

50JN250

7.60

55

1.00 2.40 1.30 3.05 0.45 1.09 0.59 1.38 1.49 1.57 1.67 1.79

50JN270

7.60

55

1.05 2.50 1.35 3.17 0.48 1.13 0.61 1.44 1.49 1.57 1.67 1.80

50JN290

7.60

54

1.08 2.60 1.40 3.25 0.49 1.18 0.64 1.47 1.49 1.58 1.67 1.79

50JN310

7.65

54

1.15 2.70 1.45 3.35 0.52 1.22 0.66 1.52 1.49 1.59 1.67 1.79

7.65

51

1.30 3.00 1.64 3.75 0.59 1.36 0.74 1.70 1.50 1.59 1.68 1.80

35JN270

50JN350
50JN400

0.35
(0.0138)

0.50
(0.0197)

7.65

47

1.45 3.25 1.85 4.05 0.66 1.47 0.84 1.84 1.52 1.61 1.69 1.81

50JN470

7.70

38

1.65 3.65 2.10 4.65 0.75 1.66 0.95 2.11 1.54 1.63 1.71 1.82

50JN600

7.75

32

2.00 4.50 2.50 5.62 0.91 2.04 1.13 2.55 1.52 1.61 1.70 1.81

50JN700

7.80

28

2.52 5.50 3.30 6.90 1.14 2.49 1.50 3.13 1.55 1.65 1.73 1.84

50JN800

7.80

24

2.95 6.30 3.65 8.00 1.34 2.86 1.66 3.63 1.57 1.66 1.74 1.84

50JN1000

7.85

18

3.25 7.20 4.15 9.15 1.47 3.27 1.88 4.15 1.59 1.69 1.75 1.85

http://www.jfe-steel.co.jp/en/products/electrical/n_core/02.html

6/26/2011

JFE Steel Corporation - Products and Services - ELECTRICAL STEEL SHEETS - JFE N-Core Typical Electrical and Magnetic Properties Page 2 of 3

50JN1300

7.85

15

3.75 8.10 4.75 10.20 1.70 3.67 2.15 4.63 1.58 1.67 1.76 1.87

65JN800

7.80

28

3.25 7.00 4.20 8.90 1.47 3.18 1.91 4.04 1.56 1.64 1.72 1.82

7.85

15

4.90 9.90 6.15 13.00 2.22 4.49 2.79 5.90 1.57 1.67 1.76 1.86

0.65
65JN1600 (0.0256)

Note :1. Values above were measured according to the method JIS C 2550 (2000).
2. Test samples were consisted of half the strips sheared parallel and half sheared transverse to the rolling
direction.
3. W15/50 indicates the core loss at 50Hz and 1.5T. B50 indicates the magnetic flux density at 5000A/m.
4. The specimens were tested as sheared.
5. The values shown above are the typical ones, not for guarantee.

Core Loss
Magnetic Flux Density
T

Grade

Thickness Assumed
Resistivity
mm
Density
-cm
3
(in.)
kg/dm

35JNE230

7.65

55

0.98 2.15 1.20 2.70 0.44 0.97 0.54 1.22 1.51 1.59 1.69 1.82

7.65

47

1.02 2.30 1.27 2.90 0.46 1.04 0.58 1.31 1.53 1.60 1.70 1.83

7.70

41

1.14 2.60 1.42 3.25 0.52 1.18 0.64 1.47 1.54 1.65 1.72 1.85

7.65

47

1.18 2.70 1.51 3.45 0.53 1.22 0.68 1.56 1.53 1.61 1.70 1.83

7.70

41

1.41 3.10 1.80 3.95 0.64 1.41 0.82 1.79 1.55 1.64 1.73 1.85

7.75

36

1.43 3.20 1.81 4.00 0.65 1.45 0.82 1.82 1.56 1.65 1.74 1.86

Watts per kilogram


50Hz

60Hz

Watts per pound


50Hz

60Hz

1.0T 1.5T 1.0T 1.5T 1.0T 1.5T 1.0T 1.5T B10 B25 B50 B100

0.35
35JNE250
(0.0138)
35JNE300
50JNE300
50JNE350
50JNE470

0.50
(0.0197)

Note :1. Values above were measured according to the method JIS C 2550 (2000).
2. Test samples were consisted of half the strips sheared parallel and half sheared transverse to the rolling
direction.
3. W15/50 indicates the core loss at 50Hz and 1.5T. B50 indicates the magnetic flux density at 5000A/m.
4. The specimens were tested as sheared.
5. The values shown above are the typical ones, not for guarantee.

Core Loss
Grade

Resistivity
Thickness Assumed -cm
mm
Density

Watts per kilogram


50Hz

http://www.jfe-steel.co.jp/en/products/electrical/n_core/02.html

60Hz

Magnetic Flux Density


T

Watts per pound


400Hz

50Hz

60Hz

400Hz

6/26/2011

JFE Steel Corporation - Products and Services - ELECTRICAL STEEL SHEETS - JFE N-Core Typical Electrical and Magnetic Properties Page 3 of 3

(in.)
20JNEH1200

0.20
20JNEH1500 (0.0080)

kg/dm3

1.0T 1.5T 1.0T 1.5T

1.0T

1.0T 1.5T 1.0T 1.5T

1.0T

B10 B25 B50 B100

7.65

55

0.92 2.13 1.12 2.62

11.0

0.42 0.97 0.51 1.19

4.85

1.46 1.57 1.67

1.78

7.65

47

1.09 2.55 1.33 3.13

12.5

0.49 1.16 0.60 1.42

5.67

1.48 1.57 1.66

1.79

Note :1. Values above were measured according to the method JIS C 2550 (2000).
2. Test samples were consisted of half the strips sheared parallel and half sheared transverse to the rolling
direction.
3. W15/50 indicates the core loss at 50Hz and 1.5T. B50 indicates the magnetic flux density at 5000A/m.
4. The specimens were tested as sheared.
5. The values shown above are the typical ones, not for guarantee.

Core Loss
Grade

Thickness Assumed
Resistivity
mm
Density
-cm
(in.)
kg/dm 3

Watts per kilogram


50Hz

60Hz

Watts per pound


50Hz

Magnetic Flux Density


T

60Hz

1.0T 1.5T 1.0T 1.5T 1.0T 1.5T 1.0T 1.5T B10 B25 B50 B100
50JNA300

7.75

36

1.21 2.66 1.55 3.44 0.55 1.21 0.70 1.56 1.59 1.66 1.74 1.86

50JNA350

0.50
50JNA500 (0.0197)

7.80

32

1.40 3.10 1.88 4.05 0.64 1.41 0.85 1.84 1.60 1.68 1.75 1.86

7.80

20

2.08 4.60 2.60 6.02 0.94 2.09 1.18 2.73 1.59 1.68 1.74 1.84

50JNA600

7.85

17

2.30 5.10 3.00 6.65 1.04 2.31 1.36 3.02 1.60 1.67 1.75 1.86

Note :1. Values above were measured according to the method JIS C 2550 (2000).
2. Test samples were consisted of half the strips sheared parallel and half sheared transverse to the rolling
direction.
3. W15/50 indicates the core loss at 50Hz and 1.5T. B50 indicates the magnetic flux density at 5000A/m.
4. The specimens were tested after stress relief annealing.
Annealingcondition: 750C (1380F) 2hrs. under neutral atmosphere.
5. The values shown above are the typical ones, not for guarantee.

Copyright 2007 JFE Steel Corporation. All Rights Reserved.

http://www.jfe-steel.co.jp/en/products/electrical/n_core/02.html

6/26/2011

You might also like