You are on page 1of 4

Setup

RX
Hierarchy [Rx]

High Rate 2M
Dual OFF

Interface [Rx]

Termination Terminated
Line Code HDB3
Equalization OFF
Balanced OFF

Payload [Rx]

Low Rate 2M
E1 Framing PCM30C

Pattern [Rx]

Out of service ON
PRBS Pattern 2^15-1
Invert ON

TX
Hierarchy [Tx]

High Rate 2M

Interface [Tx]
Line Code HDB3
Clock Src Internal
Balanced OFF

Payload [Tx]

Low Rate 2M
E1 Framing PCM30C

Pattern [Tx]

PRBS Pattern 2^15-1


Invert ON

Measurement
Mode Auto
Start Time Thu Oct 26 14:19:14 2021
Duration 24
Units Hours
Performance Type G.821
Allocation 100.00
Audible Alarm OFF
Results on start ON
Auto Save ON
Save Prompt OFF
Events Blocked

Results
General
Elapsed Time 1 days 0 hours 0 mins 0 secs
Frequency
Min (ppm): 0.00
Max (ppm): 0.00
Clock slip 0.00
Clock slip ref. OK

PDH : [2M]
LOS 0
AIS 0
LOF 0
LOMF 0
RDI 0

2M Errors
CODE 0 0.00
FAS 0 0.00
CRC 0 0.00
REI 0 0.00

BERT Alarms
LSS 0

BERT Errors
BIT 0 0.00
G.821
EFS 86400
Result PASS
ES 0
% 0.000000 %
SES 0
% 0.000000 %
AS (s) 86400
UAS (s) 0

Events
# Type Start Dur/Count
1 Start 26/10/21 14:19:14.0
2 Stop 27/10/21 14:19:13.0

Wed Oct 14:19:14 2021