Professional Documents
Culture Documents
BERT
BERT
RX
Hierarchy [Rx]
High Rate 2M
Dual OFF
Interface [Rx]
Termination Terminated
Line Code HDB3
Equalization OFF
Balanced OFF
Payload [Rx]
Low Rate 2M
E1 Framing PCM30C
Pattern [Rx]
Out of service ON
PRBS Pattern 2^15-1
Invert ON
TX
Hierarchy [Tx]
High Rate 2M
Interface [Tx]
Line Code HDB3
Clock Src Internal
Balanced OFF
Payload [Tx]
Low Rate 2M
E1 Framing PCM30C
Pattern [Tx]
Measurement
Mode Auto
Start Time Sun Oct 14:05:47 2021
Duration 24
Units Hours
Performance Type G.821
Allocation 100.00
Audible Alarm OFF
Results on start ON
Auto Save ON
Save Prompt OFF
Events Blocked
Results
General
Elapsed Time 1 days 0 hours 0 mins 0 secs
Frequency
Min (ppm): 0.00
Max (ppm): 0.00
Clock slip 0.00
Clock slip ref. OK
PDH : [2M]
LOS 0
AIS 0
LOF 0
LOMF 0
RDI 0
2M Errors
CODE 0 0.00
FAS 0 0.00
CRC 0 0.00
REI 0 0.00
BERT Alarms
LSS 0
BERT Errors
BIT 0 0.00
G.821
EFS 86400
Result PASS
ES 0
% 0.000000 %
SES 0
% 0.000000 %
AS (s) 86400
UAS (s) 0
Events
# Type Start Dur/Count
1 Start 24/10/21 14:05:47.0
2 Stop 25/10/21 11:05:46.0