You are on page 1of 2

Analytical Research & Metallurgical

Laboratories Pvt. Ltd.


TEST REPORT
Order. No. /Report No. : 2112008 - 10 Date : 15.12.2021
Total Pages : Two Page : 01 of 02
Customer : Dr. Umme Salma
AECS Maaruti College of Dental Sciences & Research Center
108, Hulimavu Tank Band Road, Off, Bannerghatta Main Rd,
Near Meenakshi Temple, BTM 6th stage, 1st Phase, Kammanahalli, Bengaluru
Requested by : Dr. Umme Salma
Product Tested : Orthodontic Adhesive with CUO Nano Particles
Sample identification : As Below
Reference : Verbal
Date of sample receipt : 11.12.2021
Sampling, if any : N. A.

Shear Bond Strength Test


Test started on : 15.12.2021 Test completed on : 15.12.2021
Specification : N. A.

Instrument Details:
Universal Testing Machine, 50kN/2.5kN, Make : FIE, Model : UNITEK 9450
Test Speed : 0.5mm/min

Sample ID: Group I White Control Group: Length: 3.40mm X Width: 3.00mm
Sample ID: Group II Pink - 0.5% CUO Np's: Length: 3.45mm X Width: 3.05mm
Sample ID: Group III Green - 1% CUO Np's: Length: 3.50mm X Width: 3.00mm

Order No Sample ID Sample No Shear Bond (Load, N) Shear Bond Strength, MPa
1 127.0 12.5
2 122.0 12.0
Group I White
2112008 3 98.0 9.6
Control Group
4 114.0 11.2
5 119.0 11.7
1 197.0 18.7
2 200.0 19.0
Group II Pink - 0.5%
2112009 3 184.0 17.5
CUO Np's
4 194.0 18.4
5 194.0 18.4

ARML/F/008/Issue/02/amend/1

# A101 & A102, KSSIDC Complex, Block II, Electronics City Phase I, Bangalore – 560100
Tel: 080-28528304, E mail: info@arml.in : Website: www.arml.in
Analytical Research & Metallurgical Laboratories Pvt. Ltd.

Order. No. /Report No. : 2112008 - 10 Date : 15.12.2021


Total Pages : Two Page : 02 of 02

Order No Sample ID Sample No Shear Bond (Load, N) Shear Bond Strength, MPa
1 210.0 20.0
2 200.0 19.0
Group III Green - 1%
2112010 3 192.0 18.3
CUO Np's
4 174.0 16.6
5 183.0 17.4

Photodocument:

Authorized Signatory
( Ramesh. B )

­­­­­­­­­­­­­­­­­­­ End Of The Report ­­­­­­­­­­­­­­­­­­­­

Note:
1. The results listed above pertain only to the tested samples and applicable parameters.
2. Sampling is not done by us unless otherwise specified
3. Samples which are degradable will be disposed immediately after testing and others will be disposed one month from the date of
issue of test report unless otherwise specified.
4. Total liability of our lab is limited to the invoice amount
5. This report is not to be reproduced either wholly or in part and cannot be used as evidence in the Court of Law
6. Any discrepancies in the test report to be reported within 30 days.
7. Customer shall be responsible for all the errors, disputes, losses or damages arising out of report(s) made using test procedures
provided by the customer.
ARML/F/008/Issue/02/amend/1

You might also like