You are on page 1of 4
CENTRAL UNIVERSITY OF KARNATAKA Experiment:3 1. AIM: - To study the operation of single phase full wave rectifier with R and RIL load 2. APPARATUS REQUIRED: - a) SCR-25TTS12~25 A / 1200Volts : 04 1b) Single phase converter firing circuit: 01 ©) Single phase Isolation transformer; 01 d) Rheostat - 150 ohms / 5 Amps: 01 Inductance - 150 mII/5S Amps with tapings :01 DC motor - 0.5 hp/ 220 V /1500 rpm; 01 R-150Q/5A, Switch ON the Mains Supply to the Firing circuit Observe all trigger outputs by varying the firing angle using INC,DEC and ON/OFF keys in the firing circuit Then observe the trigger o/p s and phase sequence. Make sure that all the trigger ofp s are proper before connecting to the power circuit. The trigger o/p pulse width varies as we vary the firing angle. Next make the connections in the power circuit. Connect 30V taping of the isolation transformer secondary to the power circuit Connect the R-load (150 Ohms Rheostat) between load points. Connect trigger pulses from single phase converter firing unit T1,T1” and T2,12° to Corresponding SCR’s(T1,T1’and 72,72’) in the power circuit. ). Switch ON the supply to the isolation transformer. Switch ON the MCB in the power circuit , switch ON the trigger o/ps in the firing unit . Note down the output voltage & output current from Voltmeter and Ammeter provided in the power circuit for different firing angle (0-180 degree). ELECTRICAL ENGINEERING DEPARTMENT CENTRAL UNIVERSITY OF KARNATAKA 13. Draw the waveforms across load and devices for different firing angle. 14, Repeat the same for different input voltage up to maximum voltage(230Volts) as provided in the isolation transformer. 15. Repeat the same for R-L load (connect Inductive load 0-150mH1 in series with Resistive load) with and without freewheeling diode and note down the waveform. 16, Tabulate the parameters. 17. Bring the firing angle to OFF position and switch off the trigger pulses 18. Switch off the MCB and transformer supply. TABULAR COLUMN. :- R-LOAD SLNO | Input | Firingangle | Output ‘Output Current Cateulated ofp Voltage- voltage Voltage (Volts) Vin ve 2Vmin (Cos a) TABULAR COLUMN- :- RL-LOAD SLNO | Input | Firingangle | Output urrent Cateulated ofp Vottage- voltage Voltage (Volts) Vin Vo= 2Vmvie (Cos a) ELECTRICAL ENGINEERING DEPARTMENT CENTRAL UNIVERSITY OF KARNATAKA For RL-load ELECTRICAL ENGINEERING DEPARTMENT CENTRAL UNIVERSITY OF KARNATAKA Vm sin ot RESULT:- Performance of Single phase full controlled converter is studied and drawn the waveforms across R & R-L loads. ELECTRICAL ENGINEERING DEPARTMENT

You might also like