Rescue connection (info)

If the user has lost the connection with the equipment because of a wrong configuration of the connection
parameters, the recovery procedure can be used (rescue connection).

At switch-on, the equipment opens a time window of 20 seconds during which it makes itself reachable on
the LAN 2 using the rescue connection address and accepts the user login through the correct username
and password. In this modality, the LAN 2 accepts only frames without VLAN tag.

E
The rescue connection IP address is: 172.20.253.13.

Once logged in, the user can configure the equipment and possible, restore the Factory Default condition.

The detection of the time window during which the rescue connection can be attempted is managed by an

IG
external software application.

RR
CO
TA
RA
ER

98 WEB LCT ALFOplus - Release 1.3 - MN.00281.E - 005