You are on page 1of 3

1

CAESAR II 2019 Ver.11.00.00.4800, (Build 190424) Date: FEB 13, 2022 Time: 1:39
Job:: 1
Licensed To:: Licensed To:: Edit name in <system>\company.txt

Table of Contents
LISTING OF STATIC LOAD CASES FOR THIS ANALYSIS ................................................................................... 2
HANGER REPORT ((TABLE DATA FROM DESIGN RUNS))...................................................................................... 3
2

CAESAR II 2019 Ver.11.00.00.4800, (Build 190424) Date: FEB 13, 2022 Time: 1:39
Job:: 1
Licensed To:: Licensed To:: Edit name in <system>\company.txt

LISTING OF STATIC LOAD CASES FOR THIS ANALYSIS

1 (HGR) CASE NOT ACTIVE


2 (HGR) CASE NOT ACTIVE
3 (HYD) WW+HP+H
4 (OPE) W+T1+P1+H
5 (Alt-SUS) W+P1+H
6 (SUS) W+P1+H
7 (EXP) L7=L4-L6
3

CAESAR II 2019 Ver.11.00.00.4800, (Build 190424) Date: FEB 13, 2022 Time: 1:39
Job:: 1
Licensed To:: Licensed To:: Edit name in <system>\company.txt

HANGER REPORT
(TABLE DATA FROM DESIGN RUNS)
THEORETICAL ACTUAL
NUM FIG. VERTICAL HOT INSTALLED INSTALLED SPRING HORIZONTAL
NODE RQD NO. SIZE MOVEMENT LOAD LOAD LOAD RATE MOVEMENT

----------+-----+-----+----+---(mm.)--+--( N.)--+---( N.)---+---( N.)---+-(N./cm. )-+--(mm.)---

360 6 2123 28.695 1632. 1871. 0. 83. 18.509


LISEGA LOAD VARIATION = 15%

** VARIABLE SUPPORT SPRING DESIGNED ................... LONG RANGE


MINIMUM ALLOWED SINGLE SPRING LOAD ........... ( N.) 831.818
MAXIMUM ALLOWED SINGLE SPRING LOAD ........... ( N.) 2499.901
RECOMMENDED INSTALLATION CLEARANCE ........... (mm.) 476.250

----------+-----+-----+----+----------+---------+-----------+-----------+-----------+----------