You are on page 1of 1

STRUCTURAL SYSTEMS 25/01/2022

W03_ WIND LOADS

1. WIND LOAD ASSESSMENT

Facade Wind Roughness factor Slenderness Pressure Wind action


pressure coeffcient in facade
(kN/m2) (kN/m2)

Windward 0.5 1.3166666666666667 0,7 0.78 0,5135


facade
Leeward 0.5 1.3166666666666667 0,7 -0.4 -0,26333333
facade

2. STRUCTURAL MODEL

Facade Wind load (kN/m2) Contributory area width Uniform wind load
(m) (kN/m)

Windward facade 0,5135 6 3,081

Leeward facade -0,26333333 6 -1,57999998

You might also like