You are on page 1of 3

MCFA Document # 000012-12C

Issue Date 7/6/2012


®
Lift
Trucks

TITLE: Code 45 Improvements

MODEL AND SERIAL NUMBER:


E3000, E3500, E4000,EC4000, EX5000, E5000, E5500, E6000, E6500,

A4EC1-10200+, A4EC2-10200+, A4EC3-20200+, A4EC4-10200+

SUBJECT: Code 45 Improvements

CAUSE: May be an open FET on the board.

The information provided on this web site is considered to be confidential information and is intended to assist you in resolving product issues. In addition, the information
on this web site is not to be considered as an authorization for any financial claim against MCFA.
Always follow all Safety, Warning, Caution and Precaution information that is provided in the appropriate Service Manual and Operation and Maintenance Manual(s).

RESOLUTION
Replace the inverter if needed.
MCFA Document # Page ______ of ______
®
Lift
Trucks

We continue to make improvements to correct code 45 issues and this has resulted in a
reduction of code 45.

One of the improvements is in the solder process for the heat sinks of the FET’s and to
X-ray every board today.

We have included some examples of the FET x-rays to identify the voids in the solder
process.

We continue product improvements and our quality processes. The next page provides
a glimpse of the depth of our analyses and quality capabilities where the FET solder
connection voids have been x-rayed.