You are on page 1of 1
1. Safety notes General > The system manufacturer must ensure representation and operation (usability) ofthe selected functions and adjusted values. > The device is classed as “conventional equipment" (closed equipment without protection against the ingress of water) > Before using the device forthe first time, store it at room temperature for 24 hours, > The device is not approved for operation in potentially explosive atmospheres. Use only original W&H accessories and spare parts or accessories approved by W&H! Electrical supply > The operation ofthe device is permitted only on supply units wl (EN 60601-1) and IEC 60601-1-2 (EN IEC 60601-1-2) > The power supply unit forthe dental nit must satisfy the following requirements to be guaranteed by the system manufacturer: > The leakage currents ofthe applied part must be kept. > Double insulation for the highest expected primary voltage must be provided between the primary and secondary power circuits, > Double insulation for the highest expected secondary voltage must be provideg between the secondary voltage and protective earth (PE). > The secondary circuits must be pratected against short circuits and overloading > The power supply voltage must not exceed 42.4 Vpeak or 60 VDC (in SFC condition}! > Maximum 1 kV transient voltage peak onthe secondary ctcuit with a test voltage of 4 KV and 1.2/50 us waveform (IEC 61180] on the primary circuit > Disconnect the dental unit from the power supply before opening. > The system manufacturer must provide the declaration for separation devices. correspond to the standards IEC 60601-1 Installation > The device may only be installed by qualified staff authorized by the system manufacturer. > The system manufacturer is responsible forthe final inspection, measuring and compliance of the leakage currents according ‘0 IEC 60601-1 (USA, Canada CB certificates EN 60601-1, UL GO6O1-1, CAN/CSA 22.2 no. 601.1) and the electromagnetic. ‘compatibility (EMC according to IEC 60601-1-2) after instalation > Comply withthe instructions for electrostatic discharge (ESO) when handling electronic devices. > Wiring ofthe liquid hose and electrical wires in the dental unit have to be carried out by the system manufacturer according to standard IEC 60601-1. > Perform a test run after the installation. In the event of operating malfunctions (e.g, unusual noise, overheating], stop the device immediately and contact an authorized service partner, > The system manufacturer is responsible forthe integration according to standard IEC 60601-1 (EN 60601-1) > Check the device for damage and loose parts each time before using. Mounting area > Do not install the device close to a strang heat source. > Place the device in an adequately ventilated location to prevent overheating. > The device has to be installed ina fire protection housing, Installation of the supply hose (motor) > The devices approved for use only with supply units with category 5 backflow prevention devices as defined in EN 1717. > Do not connect supply hose to the hot water supply. > Install an adequate strain relief for the supply hose. > Do not twist, kink or squeeze the supply hose [risk of damage). Periodic inspection > Regular periodic inspection of the function and safety of the device is necessary and should be carried out at least once every three years, unless shorter intervals are prescribed by law. > The periodic inspection covers the complete device and must only be performed by an authorized service partner,

You might also like