You are on page 1of 1

SEPARABLE CONNECTORS

FUSED ELBOWS 200 AMP LOADBREAK 5-15kV Part numbers that contain
DEADFRONT the letters W or X are size
CABLE JOINTS 200 AMP DEADBREAK 25kV PART # sensitive. To complete the
LIVEFRONT part number, refer to the
TERMINATIONS 600 SERIES DEADBREAK 35kV W or X tables indicated.
SURGE ARRESTERS

600 SERIES DEADBREAK


Illustration Description Voltage ELASTIMOLD Notes Illustration Description Voltage ELASTIMOLD Notes
(not to scale) Class Part Number (not to scale) Class Part Number
600 Series Elbow 15/25kV K655LR-W0X N1,2 Deadbreak 15/25kV K650RTP N1,7,8,9
(w/ Insul. Plug, Use Tables W7 and X6 Reducing
Cap, Stud, Lug & 35kV 755LR-W0X N1,2 Tap Plug
Cable Adapter) Use Tables W9 and X6 Reducing Tap 15/25kV K650RTW N1,7,8,9
600 Series Elbow 15/25kV K656LR-W0X N1,2 Well
w/ Test Point Use Tables W7 and X6 Loadbreak 15kV 650ETP N1,7,8,10,13
(w/ Insul. Plug, 35kV 756LR-W0X N1,2 Reducing 25kV K650ETP N1,7,8,10,13
Cap, Stud, Lug & Use Tables W9 and X6 Tap Plug 35kV 750ETP N1,7,8,10,13
Cable Adapter)
Vault Stretcher 15/25kV 650VSA N1
600 Series Elbow 15/25kV K655BLR N1,3 Threaded Stud
Housing only 35kV 755BLR N1,3
(w/ Stud) 600 Series Elbow 15/25kV 650SA N1
Threaded Stud 35kV 750SA N1
600 Series Elbow 15/25kV K656BLR N1,3 Assembly Tool ALL 600AT N10
w/ Test Point 35kV 756BLR N1,3
(Housing only Spanner Wrench ALL 600SW N9
w/ Stud)
600 Series Straight 15/25kV K655SR-W0X N1,2,12 2-Point Junction 15/25kV K650J2 N1,11
Receptacle Use Tables W7 and X6 35kV 750J2 N1,11
(w/Cable Adapter,
Lug & 3-Point Junction 15/25kV K650J3 N1,11
Retaining Ring) 35kV 750J3 N1,11
600 Series Straight 15/25kV K655BSR N1,12
Receptacle
Housing (Lug 4-Point Junction 15/25kV K650J4 N1,11
& Cable Adapter 35kV 750J4 N1,11
not included)
Straight Receptacle 15/25kV K650SRA N1,4
Adapter
N1. For 900 Amp ratings, substitute 675 for 650 and 655; 676 for 656; K675
600 Series 15/25kV K655BVS N1,9
for K650 and K655; K676 for K656; 775 for 750 and 755; 776 for 756
Vault Stretcher
and 2X for 0X in the part number. The 900 Amp rating requires copper
(Housing only
current-carrying connector components and copper conductor cable.
w/ Stud)
N2. Add suffix symbol from page 29 to include cable shield grounding kit
Cable Size 15/25kV 655CA-W
and/or cable jacket sealing kit.
Adapter Use Table W7
35kV 755CA-W N3. Available without the stud by adding “N” to the part number.
Use Table W9 N4. Straight Receptacle Adapter is used to connect Straight Receptacles
Compression ALL 03700X N5 K655YBSR and K655YSR-W0X (Pg.14) to equipment bushings.
Lug Use Table X6 N5. Aluminum lug for use on aluminum or copper conductors. DO NOT
ALL 03702X N6 substitute threaded 03600X lug.
Use Table X6 N6. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT substitute
600 Series Elbow 15/25kV 655CK-W0X N2 threaded 03602X lug.
Size Sensitive Kit Use Tables W7 and X6 N7. Available with the stud factory-assembled by adding “SP” to the part
(Cable Adapter 35kV 755CK-W0X N2 number.
& Lug) Use Tables W9 and X6
N8. Available with a loose stud by adding suffix “S” to the part number.
Adapter ALL 650ARR-X
N9. 600SW spanner wrench is recommended for installation of connecting
Retaining Ring Use Table X6
plugs, deadbreak reducing tap plugs and reducing tap wells..
N10. 600AT assembly tool is required for installation of loadbreak reducing
600 Series Straight 15/25kV 655CK-W0X-ARR N2
tap plugs.
Receptacle Size Use Tables W7 and X6
Sensitive Kit (Cable 35kV 755CK-W0X-ARR N2 N11. Rubber junction with stainless steel mounting plate and back plate.
Adapter, Retaining Use Tables W9 and X6 Add “-U” for rubber junction with stainless steel mounting plate, back
Ring & Lug) plate and adjustable bracket.
Add “-4” for rubber junction only.
Bushing 15/25kV K655BE N1,3
Add “-5” for rubber junction, stainless steel U-straps and back plate.
Extender 35kV 755BE N1,3
(w/ Stud) N12. 600 Series Elbows and Straight Receptacles with IEEE Std. 386
capacitive test points are available by substituting 656 for 655; K656 for
Insulated Cap 15/25kV K656DR N3,7
K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776
w/ Test Point
for 775 in the part number.
(w/ Stud)
N13. See page 17 for Window-Op Connector Kit.
Insulating Plug 15/25kV K650BIP N1,7,8
(w/ Cap) 35kV 750BIP N1,7,8
Grounding Plug 15/25kV 650GP N1,7,8
(Ground Lead 35kV 750GP N1,7,8
2/0 AWG x 30")
Insulated 15/25kV K650SOP N7,8 Refer to the W and X tables on pages 32 and 33 for sizing to cable
Parking Bushing 35kV 750SOP N7,8 insulation diameter and conductor size.
Connecting Plug 15/25kV K650CP N1,7,8,9 For cable shield adapters and jacket seals, see page 28.
35kV 750CP N1,7,8,9

CATALOG 2001 Page 11 ID: 0198

You might also like