Professional Documents
Culture Documents
LAND KEY:
NORTH
B
2
B
1 7A 3
B
7B
4 5 6 7
B
G
E
N
E
R
A
L
N
O
T
E
S
:
1. ALL DIMENSIONS ARE IN MILLIMETERS.
2. ALL LEVELS SHOWN ON DRAWINGS ARE FINISHED FLOOR LEVELS UNLESS
SPECIFIED OTHERWISE.
3. THIS DRAWING IS A COPYRIGHT AND PROPERTY OF THE ARCHITECT, IS NOT
TO BE PRODUCED, COPIED, HANDED OVER TO THIRD PARTY OR USED FOR
ANY OTHER PURPOSE OTHER THAN FOR WHICH IT IS INTENDED.
4. ALL DIMENSIONS SHALL BE VERIFIED ON SITE PRIOR TO START OF WORK ANY
DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT.
5. THE CONSTRUCTION MANAGER/CONTRACTOR MUST CHECK ALL DIMENSIONS
-R -Q -P -N -M -L -K -J -H -G -F -E -D -C -B -A Y +A +B +C +D +E +F +G +H +J +K +L +M +N +P +Q +R AND DETAILS AND BE RESPONSIBLE FOR THE SAME. ANY DISCREPANCY
SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT.
6. THIS DRAWING IS TO BE READ AND NOT SCALED.
7. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT
5900 9000 9000 9000 9000 9000 5900 8000 9000 9000 9000 9000 9000 9000 9000 4500 4500 9000 9000 9000 9000 9000 9000 4500 9000 9000 9000 9000 4500 9000 4500 9000 ARCHITECTURAL, STRUCTURAL AND SERVICES DRAWINGS. ANY
DISCREPANCY NOTICED SHALL BE BROUGHT TO THE ATTENTION OF THE
CONSULTANTS WITHIN PROCUREMENT / EXECUTION OF WORKS.
8. ANY DRAWING PREPARED BY THE CONTRACTOR/SUB-CONTRACTOR/ VENDOR
AND APPROVED BY THE ARCHITECT/PROJECT MANAGER IS FOR GENERAL
CONFORMITY WITH THE OUTLINE DESIGN INTENT ONLY. SUCH APPROVALS DO
NOT RELIEVE THE CONTRACTOR TOGETHER WITH THE SUB-
CONTRACTOR/VENDOR FOR FULL RESPONSIBILITY FOR ACCURACY,
INTEGRATION AND FITNESS OF DESIGN (TO THE EXTENT APPLICABLE) AND
LEGEND : FOR MEETING THE PURPOSE OF DESIGN.
CONSTRUCTION
REFER TO DWG No. Booster Cold Water Supply Pipe Line (BCWS)
A101-CEC-MH43-DWG-GF0102 Hot water Supply Pipe Line (HWS)
Hot water Return Pipe Line (HWR)
Water Feature Line
AIR LOCK
Main Incoming Potable Water Line
Tanker Inlet Line
Control Cable
WM WATER METER
ACCESSIBLE TOILET
TOILET (M)
IT ROOM
IDF
STORAGE IDF
CORRIDOR
ELECTRICAL ROOM AIR LOCK
PLUMBING SHAFT
ST-04
IV ISOLATION VALVE
WASTE HOLDING FHC
PLUMBING+ CHWS/R SHAFT
STORAGE
HR WALL MOUNTED HOSE REEL
9000
COMMUNITY OFFICE
BOH CORRIDOR
A101-CEC-MH43-DWG-GF0101
MEETING ROOM 02
MECHANICAL ROOM
SERVER ROOM
BT BIP TAP
COMMUNITY OFFICE
STORAGE A101-CEC-MH43-DWG-GF0103
+5 FIRE ALARM CHECK VALVE
PP POTATO PEELER
VVIP LIFT LOBBY
TOILET
STORAGE
CCTV ROOM
GCO GAS COMBI OVEN
CORRIDOR
ELECTRICAL ROOM
9000
COMMUNITY OFFICE
PL-03 PL-04
UR URINAL
STORAGE ELECTRICAL ROOM IDF
FHC MEP ROOM
BATTERY AND FA ROOM-02
FIRST AID ROOM
? ? STORAGE
FHC
SH SHOWER
ELECTRICAL ROOM
?
SHOE HOUSE ? BOP BOTTOM OF PIPE
CORRIDOR
9000
BOOKSHOP
JS JANITOR SINK
Ve ntusDo ub le Doo r
BOTT L E COOLER
+2
F 76 /2 00
V90
Ve ntusDo ub le Doo r
BOTT L E COOLER
ST STRAINER
F 76 /2 00
V90
TOILET (M)
TOILET (F)
Ve ntusDo ub le Doo r
BOTT L E COOLER
F 76 /2 00
V90
ORIENTATION ROOM
Ve ntusDo ub le Doo r
BOTT L E COOLER
F 76 /2 00
V90
MAJLIS LOBBY
CAFE SHOE HOUSE CV CHECK VALVE
ACCESSIBLE TOILET
?
FOR FUTURE CONNECTION
VESTIBULE
?
ICM ICE CUBE MACHINE
12845
1200x1200x1000
STR STRAINER
? DEVOTEES COURTYARD
STORAGE
0
0
0
7
.
0
4
.
2
2
I
S
S
U
E
D
F
O
R
T
E
N
D
E
R
A
K
A
V
TOURIST COURTYARD
O
W
N
E
R
:
MAINTENANCE CORRIDOR
?
BOH CORRIDOR
REFER TO DWG No. ?
A101-CEC-MH43-DWG-GF0109
-1 MEP ROOM + WATER CABINET PLUMBING SHAFT
E
L
V
S
P
E
C
I
A
L
I
S
T
CORRIDOR WATER PUMP ROOM
6500
CHWS/R SHAFT
TOILET (F)
PLUMBING SHAFT
GSM BOH CORRIDOR VESTIBULE CORRIDOR
CORRIDOR
LOBBY
ST-03
SHRIJIMCO TECHNICAL SYSTEMS FZC
-2 SHOE RACK STORE
P
.
O
.
B
o
x
1
6
1
1
1
SHOE STORE PL-01
ACCESSIBLE TOILET CLASS ROOM-01 CLASS ROOM-02 CLASS ROOM-03 VESTIBULE
FHC FHC
U
.
A
.
E
GSM
LOBBY
T
e
l
:
+
9
7
1
7
2
0
4
2
8
0
3
TOILET (F) MAJLIS (F)
9000
F
a
x
:
+
9
7
1
7
2
0
4
1
0
1
0
STORE
PRE-FUNCTION B
STORE SHOE RACK STORE
SHOE RACK SHOE RACK STORE MECHANICAL ROOM
ELECTRICAL ROOM
LOBBY
CORRIDOR MAJLIS (M)
L
I
G
H
T
I
N
G
C
O
N
S
U
L
T
A
N
T
TOILET (M)
CORRIDOR ELV ROOM
MAKE-UP AIR SHAFT RAMP
SHOE RACK SHOE RACK
ELECTRICAL ROOM IDF ROOM ELECTRICAL ROOM
CONTROL CUPBOARD SERVER ROOM
DIVIDER STORAGE MAKE-UP AIR SHAFT
-3 CORRIDOR
?
Studio Lumen
CLASS ROOM-04 CORRIDOR
? ACCESSIBLE TOILET
SHOE RACK ELECTRICAL ROOM
MEETING ROOM
BOH CORRIDOR
SHOE RACK CORRIDOR
ACCESSIBLE TOILET
9000
TOILET (F)
PUTM
.
OA
.E:b
B
o
x
7
3
8
8
9
,
D
u
b
a
i
,
TOILET (M)
STORAGE STORAGE
IT ROOM
CCC ROOM
eo
l
+0
95
76
19
44
38
34
85
53
86
0
6
MAKE-UP AIR SHAFT TOILET (M) CAFE
ELV ROOM
CONTROL CUPBOARD
:
ELECTRICAL ROOM
? OFFICE
-4
SHOE RACK STORE
? TOILET
LEAD CONSULTANT :
ELECTRICAL ROOM
MAINTANENCE STAFF STAFF DINING
?
ARCHITECTURE, INTERIOR & LANDSCAPE
GSM PROJECTOR MAINTENANCE ACCESS 1100
TOILET (M)
TOILET (F)
MAINTENANCE WORKSHOP HOUSEKEEPING STORAGE
ACTIVITIES OFFICE
320
V90 V90 V90 V90
320
Ve ntus Dou bl e Do or Ve ntus Dou bl e Do or Ve ntus Dou bl e Do or Ve ntus Dou bl e Do or
-5
BOTT L E COOLER BOTT L E COOLER BOTT L E COOLER BOTT L E COOLER
F 76 /2 00 F 76 /2 00 F 76 /2 00 F 76 /2 00
C D C D C D
CG CG CG
OO
MOB
R DP
R
C
E
T
L
1
0 U
E
?
1
SHOE RACK
OO
MOB
R DP
R
C
E
T
L
1
0 U
E
9000
EP1440 G
0
.4
1
9
2
.8
4
M
O
BIL
EP1440 G
E
0
.4
1
EP1440 G
0
.4
1
TROLLEY PARKING AREA
DIVIDER STORAGE
425
DIVIDER STORAGE
A101-CEC-MH43-DWG-GF0107
BOH CORRIDOR (CLEAN)
M
M
M
O
O
O
O
BIL
BIL
BIL
BIL
BIL
BIL
E
E
E
STORE
ARCHITECT OF RECORD :
HEAVY DUTY RACKS
SIZE 2MTRX1.2MTR
4 SHELVES
4 SHELVES
A101-CEC-MH43-DWG-GF0106
MAKE-UP AIR SHAFT CHILLER
MAKE-UP AIR SHAFT HEAVY DUTY RACKS HEAVY DUTY RACKS HEAVY DUTY RACKS HEAVY DUTY RACKS
PRE-FUNCTION B HALL-A1 4 SHELVES 4 SHELVES 4 SHELVES 4 SHELVES
SIZE 2MTRX1.2MTR SIZE 2MTRX1.2MTR SIZE 2MTRX1.2MTR SIZE 2MTRX1.2MTR
EZ
?
SIZE 2MTRX1.2MTR
SIZE 2MTRX1.2MTR
EZ
Front door
4 SHELVES
4 SHELVES
-7
HEAVY DUTY RACKS
SIZE 2MTRX1.2MTR
200
4 SHELVES
4 SHELVES
EP1440 G EP1440 G
?
HEAVY DUTY RACKS
SIZE 2MTRX1.2MTR
9
3
2
1
.5
A101-CEC-MH43-DWG-GF0104
HEAVY DUTY RACKS
PRE-FUNCTION B HEAVY DUTY RACKS
4 SHELVES
4 SHELVES HEAVY DUTY RACKS
4 SHELVES SANITISING AREA
SIZE 2MTRX1.2MTR 0
2
9
5
.7
TO PUMP ROOM
STORAGE
DE-WATERING ROOM
9000
FHC
ST-01
BOH CORRIDOR
P
U
R
P
O
S
E
O
F
I
S
S
U
E
:
SHOE RACK SL-01
TEMPORARY REFUSE HOLDING AREA
SHOE RACK ELV ROOM
1
3
4
. 1
3
7
6
.4
2
LOBBY
ST-02 SL-02
GENERAL GARBAGE ELECTRICAL ROOM
DE-BOXING AREA
SORTING ROOM
TENDER SUBMISSION
-8
9
2
5
1
.4
LV ROOM
PB
RA
OP
JS
E
CH
TI
ND
AU
M
EM
:A
FIRE ALARM CHECK VALVE
ELECTRICAL ROOM BOH CORRIDOR
TOILET ?
FOR FUTURE CONNECTION
N
D
I
R
,
A
B
U
D
H
A
B
I
RECEIVING AREA
GREEN ROOM
9000
STORAGE
FCC ROOM TOILET
A101-CEC-MH43-DWG-GF0105
CLEAN AGENT ROOM STORAGE
ENTRANCE CORRIDOR
P
R
O
J
E
C
T
D
E
S
C
R
I
P
T
I
O
N
:
IDF ROOM
People of the UAE. Through the Universal Values of Love, Peace and
1200x1200x1000 Harmony with Buildings Surround the Temple
VALVE CHAMBER Ø100 TANKER INLET LINE
Ø100 TANKER INLET LINE FOR
D
R
A
W
I
N
G
T
I
T
L
E
:
IRRIGATION WATER TANK
O
V
E
R
A
L
L
G
R
O
U
N
D
F
L
O
O
R
W
A
T
E
R
L
A
Y
O
U
T
Ø150 MAIN INCOMING POTABLE WATER LINE
DN DN DN
DA
R1
A0
W1
I
N-
GC
NC
O
.-
:M
JA
O
B1
N0
O1
:
FINAL LOCATION OF THE WATER METER LOCAL AUTHORITY MAIN SHEET SIZE:
H
2
2
-
D
W
G
-
G
F
0
1
0
1
DOMESTIC WATER TANK REV NO. :
SHALL BE COORDINATED AS PER SITE WATER METER WITH WATER
Ø100 BREACHING INLET CONDITION MANHOLE CHAMBER A0 R0
D
R
A
W
N
B
Y
C
H
E
C
K
E
D
B
Y
A A
P V
P
R
O
V
E
D
B
Y
D
A
T
E
:
S
C
A
L
E
:
FOR IRRIGATION TANK
INCOMING DOMESTIC WATER
CONNECTION FROM ADDC MQS AK 07.04.22 As indicated