Energy Saving
Comparison of cooling seasonal power
consumption based on average
50%
CSPF values
power consumption
Cooling seasonal
Throughout the cooling season, Daikin’s 100 reduction!
Panel (Fresh White) Panel (Black) new inverter models reduce energy
consumption.
Compared with previous non-inverter series, the new
RZF-C series uses about 50% less power 50
consumption for quick and effective cooling that
reduces electricity bills.
Previous non-inverter New inverter RZF-C
series (average) series (average)
(cassette type) (cassette type)
1. Blows horizontally
CSPF values by capacity for cassette models
New inverter RZF-C series R32 <cassette type>
- Fresh White - - Black - *1. Source: Values for 100-year global warming potential (GWP) from IPCC Fourth Assessment Report. Comparative 100-year GWP: HFC410A, 2,090; HFC32, 675.
1 2
NEW Circulation Airflow Evenly Distributes Cool Air *1 *1. Applicable when wired remote controller BRC1E63 is used.
Airflow until now had areas that were either too cool or not cool enough. Comfort to the Entire Room with Even Temperatures and No Cold Air Pockets at Floor Level
30.0
4-way cassette (Swing) 29.0
Comparison Conditions
28.0
Problem 1
Room size:
27.0 Width 7.5m x depth 7.5m
26.0 x height 2.6m
Hot outdoor air entering through 25.0 Indoor unit capacity: 71 class
24.0
4-Way Flow
windows and walls causes these 23.0
Outdoor air temperature: 35°C
areas to become hot. 22.0 Airflow rate and air direction:
21.0 high / swing
20.0
Problem Problem 2
Hot Areas at floor level are
Cool air accumulating directly outdoor cold while areas
underneath causes cold air air around walls are hot.
pockets at floor level.
4 2
temperature. (26°C)
Quick descent of cool air causes
insufficient cooling for corners of Full comfort is
the room. provided with no
cold feet.
Wall surface
temperature is reached, switches from 3-way horizontal flow to 4-way downward flow [swing] to Distance Minimum distance between
normal operation 2-way horizontal flow to 4-way downward flow [swing].) to wall indoor units [Table 2] [Table 2]
[Table 1] Minimum distance between indoor units
(all-round flow) begins. Circulation airflow functions during connection with wired remote controller. 1.8m or more above floor surface
(BRC1E63). However, use is not possible for the following conditions:
Indoor unit
capacity FCF50-71 FCF100-140
Note: - When a sealing material of air discharge outlet and branch ducts are used; Floor surface
Minimum
Results may vary depending on - When individual airflow setting is selected; distance 5m or more 7m or more
Cools areas around Cools entire room Cools areas around Cools entire room
walls using using 4-way walls using using 4-way equipment conditions, room size, - When using group control other than round flow.
2-way horizontal flow swing flow 2-way horizontal flow swing flow and distance from indoor unit to walls.
3 4
NEW Individual Airflow Direction Control *1 *1. Applicable when wired remote controller BRC1E63 is used.
NEW Daikin Sensing Technology *1,2 *1. Applicable when wired remote controller BRC1E63 is used.
*2. Applicable when sensing panel (BYCQ125EEF) is installed.
Comfortable air conditioning for all room layouts and conditions Dual Sensors*2
Dual sensors and individual airflow direction control automatically provide
Airflow direction can be individually
adjusted for each air discharge outlet to
Easy setting is possible with a wired remote controller. optimal control of airflow.
deliver optimal air distribution.
NEW
BRC1E63
Infrared presence sensor
There are
Position 0 identification The sensor detects the presence of people in each of the
(Fixed airflow to marks near 4 areas.
the air outlets.
highest position)
Remote controller Ceiling height 2.7m 3.5m 4.0m
screen
Detection range approx. approx. approx.
(diameter)*3 8.5m 11.5m 13.5m
*3. The infrared presence sensor detects 80cm above the floor.
Detecting the
presence of people
Individual airflow settings in each of the 4 areas Infrared floor sensor
No individual
setting ・No individual setting (Auto airflow)
(Auto airflow) ・Position 0 (Highest point)
C
The sensor detects the floor temperature and
・Position 1 automatically adjusts operation of the indoor unit to
・Position 2 B D reduce the temperature difference between the ceiling
・Position 3
A
and the floor.
Swing Position 4 ・Position 4 (Lowest point)
(Up/down) (Fixed airflow to the ・Swing Ceiling height 2.7m 3.5m 4.0m
lowest position) Detecting the
Individual settings are possible as stated above. average temperature Detection range approx. approx. approx.
of the floor (diameter)*4 11m 14m 16m
When individual airflow is selected, airflow direction can be adjusted to room layout. *4. The infrared floor sensor detects at the floor surface.
Swing
Swing is
selected for
Auto Airflow Function*5 *5.Airflow direction should be set to “Auto”.
areas near
the windows. No individual (Auto)
Direct Airflow (default: OFF) Cooling Dry
Auto is set for people
sitting farthest from
The seats here the entrance.
When human presence is not detected When human presence is detected
Sitting here is hot are comfortable
because of the hot air though…
from outside.
Position 0
For offices The airflow is at the
highest setting (Position 0)
for people who
Swing dislike air blowing
Discussions near Swing is set for directly on them.
a hot window meetings near
quickly heat up.
the windows.
Optimal air direction by “Auto”
5 6
Product Lineup
Cooling only
DUCT CONNECTION
MIDDLE STATIC
PRESSURE TYPE
OUTDOOR UNIT
Outdoor unit RZF50CVM RZF60CVM RZF71CVM RZF71CYM RZF100CVM RZF100CYM RZF125CVM RZF125CYM RZF140CVM RZF140CYM
7 8
Quick Cooling Benefits of Inverters
Faster cooling and dehumidification NEW Quick cooling start function
ew in erter control technology brings uic comfort. uic ly and easily ma e space comfortable before
Why is inverter technology economical?
the arri al of office wor ers or shop customers.
Total cost =
reduction provides greater comfort (within a maximum
New Inverter (RZF-C series) of minutes .
Usual Inverter (RZR-L series) This results in lower total cost.
Inverters save more
Non inverter energy over time
Capacity
Time
Recovery point
INV Max
Non Max Inverter air conditioner can adjust its Rated condition
Better performance
cooling capacity according to the
than non-inverter models! cooling load. This results in less
Reaches maximum capacity faster
power consumption. Non inverter cooling capacity
Capacity
than usual inverter models.
Load
n response to fluctuating cooling load on in erter On/Off operation
air conditioners repeatedly perform ON (full-power)/ Lower efficiency Inverter cooling capacity
Time O ero power operation. n erter air conditioners
Start
howe er operate at optimal cooling capacity according
BRC1E63 wired remote controller to the cooling load. ince in erter air conditioners Cooling load Partial load area
Indoor is used for uic cooling start . provide required minimum cooling capacity with
Reaches the
temp. minimum electrical power total power consumption 0
set temperature faster. 35
can be reduced during cooling period.
Outdoor ambient temperature C
Setting
temp.
Start Time
Indoor Removes Continuous driving without stopping and starting is Constantly stopping and starting consumes energy
humidity humidity faster. more fuel efficient. and is less fuel efficient.
Start
Why is inverter technology more comfortable?
Inverter
When temperature does not
Non inverter
Non inverter
Too cold Too cold
Time
9 10
Durability Convenient Functions
Overvoltage PCB Microchannel heat exchanger Navigation remote controller BRC1E63 includes various
(Outdoor unit option) Microchannel technology utilises superior heat transfer convenient functions
benefits of aluminium to create a more efficient air Automatic return to temperature preset by owner. Owner can preset upper and lower temperatures.
Unstable power supply is a common problem in many conditioner.
regions. It can cause overvoltage which can significantly With a new resistance corrosion aluminium alloy, the Setpoint auto reset Setpoint range set
damage electronic devices. Daikin microchannel heat exchanger becomes highly - Even if the set temperature is - Saves energy by limiting the min.
To prevent voltage fluctuations, it is usually necessary to durable. changed, the new set and max. set temperature.
attach a stabiliser when installing an air conditioner. A salt spray test has been conducted to demonstrate the temperature returns to the - Avoids excessive heating or
The RZF-C series is equipped with a highly-durable corrosion-resistant capability of our products in previous preset value after a cooling.
electronic circuit. preset duration of time. - This function is convenient if the
corrosive environments for a certain period of time.
- Period selectable from 30, 60, remote controller is installed
This circuit eliminates the need for a stabiliser and offer
90, or 120 minutes. where anyone can change the
additional protection for devices in the outdoor unit, Test of durability
settings.
such as its fan motor and compressor. - Testing organization MTEC Thailand
- Testing standard ASTM B117
- Result
Restaurant example
Automatic protection against Before testing After testing
Restaurant opened Full tables at lunchtime After 30 minutes*
low voltage
In AM and PM peak electricity consumption periods, 27 °C 24 °C Returns to
supply may fluctuate. Built-in low-voltage protection will 27 °C
automatically cut operations. When normal voltage is Normal Under automatically
restored, operation will resume as before. observation telescope
No evidence of corrosion was observed
prompt maintenance response - Power consumption is given first priority, and limits maximum power
consumption of unit.
* Required for KRP58M51 (Option)
Limitation
100
consumption
m or An error message appears on the LCD of the remote Maximum power consumption can be set at 40, 60, 70, 80, or 100%.
mo m or m me
Power
re 0 r
100
m 10 mo or
controller and an LED lights up on the unit.
mo m or m When the BRC1E63 is installed, the error code appears
re 0 0m ore
5 m showing contact information and model name. Contact
your Daikin dealer and provide the error code and 8:00 12:00 16:00 20:00 Time
model name.
Capacity (%)
caused by humidity 100
The operating
and airborne dust.
noise bothers 8 hours
It also protects against me at night! 10 hours
50
salt contained in sea
Load (%)
breezes.
0
Both sides of the PCB 48
Sound (dB(A))
in outdoor units are Rated
Operating
coated. Quiet mode
44 Quiet mode
11 12
Design Flexibility Smart Airflow Control
Possible to forced OFF and ON/OFF operation using external command Indoor units can provide 5-step and 3-step fine control of air volume
*Field setting with remote controller 5-step: FCF and FHA series
3-step: FBA and FAA series
Round flow cassette type Duct connection middle static pressure type
Also convenient for high ceilings and spaces with long blow distances
presence detection signal can be output and interlocked
with external equipment such as ventilation and lighting
equipment. *Field setting with remote controller
Cassette type <Round Flow>: Ceiling suspended type:
External equipment also
maximum 4.2 m* maximum 4.3 m
Presence Sensor Sensor automatically turns ON/OFF.
detection Undetected Detected
signal Contact OFF Contact ON Further energy savings
Lighting Ventilation and power conservation
equipment equipment
Infrared presence Note:
sensor information Adaptor for wiring: When the presence detection signal is output to external equipment using the adapter 4.2 4.3
KRP1C11A (Option) for wiring, other functions, such as interlock with the duct booster fan and the output m m
of other signals, become disabled.
Previous indoor unit New indoor unit See page 19 See page 26
*Maximum 4.2 m for FCF100, 125, 140
Maximum 3.5 m for FCF50, 60, 71
Adaptor not
required
Optional
FHQ-BV interface adaptor
is required FHA-B
More Economy or Comfort in Special Situations
VRV
VRV High sensible cooling enables High dehumidification cooling
even greater power savings provides even greater comfort
In locations such as In restaurants and other
simple server rooms, spaces where many people
dehumidification is not gather igh
required and greater dehumidification cooling
power savings are mode reduces humidity and
possible with 'High creates greater comfort.
sensible cooling' mode.
13 14
CEILING MOUNTED CASSETTE TYPE Round Flow
Circulation Airflow
Cassette air conditioner with 360° Cools the entire room to deliver comfort that never feels cold.
NEW
Cooling only BRC7M635F
(Fresh white)
BRC7M635K Selectable Airflow Pattern
(Black)
Because air flows out from corner outlets, comfort spreads more widely.
Signal receiver unit
(Installed type)
L-shaped Opposite
All-round flow 3-way flow
2-way flow 2-way flow
Panel variations
15 16
CEILING MOUNTED CASSETTE TYPE Round Flow
Daikin Sensing Technology*1,2 *1. Applicable when sensing panel (BYCQ125EEF) is installed.
*2. Applicable when wired remote controller BRC1E63 is used.
Comfort and Energy Saving Preventing Overcooling*6 *6.Airflow direction and airflow
rate should be set to “Auto”.
Area around feet gets too cold because the air The floor temperature, Automatic control using
Detecting the
presence of people
Infrared floor sensor conditioner continues until the temperature near the which is lower than the temperature near the
ceiling reaches the set temperature. near the ceiling, is person as the room
in each of the 4 areas detected. temperature.
The sensor detects the floor temperature and
automatically adjusts operation of the indoor unit to
C
reduce the temperature difference between the ceiling Energy The temperature near the person is automatically calculated by detecting the temperature of the
and the floor. savings floor. Energy is saved because the area around the feet does not get too cold.
B D
A
Ceiling height 2.7m 3.5m 4.0m
Detection range approx. approx. approx.
(diameter)*4 11m 14m 16m Sensing Sensor Functions*7,8 *7. These functions are not available when using the group control system.
*8. User can set these functions with remote controller.
Direct Airflow (default: OFF) Cooling Dry Shift temperature and time can be selected from 0.5 to 4°C in 0.5°C increments and 15, 30, 45, 60, 90 or 120 minutes respectively
with remote controller.
When human presence is not detected When human presence is detected *9. On basic screen of remote controller, set temperature does not change.
17 18
CEILING MOUNTED CASSETTE TYPE Round Flow
Auto-swing
Note:
1
Air direction is set to the
standard position when the
Easy height adjustment
5-level unit is shipped from the Each corner of the unit has an
air direction setting factory. The position can be
changed from the remote adjuster pocket that lets you
controller. easily adjust the unit's
The air direction is set automatically to the memorised 2
Closing of the corner
Auto air direction position of the previous air direction. suspended height.
discharge outlets is
control recommended.
Note:
If the wireless remote controller is installed,
Control of airflow rate has been improved from 3-step to 5-step. Indoor unit
Sound pressure level
Auto airflow rate is newly available. H HM M ML L
50-71C 37.0 34.5 32.0 29.5 27.5
100C 45.0 41.5 38.0 35.0 32.5
Suitable for high ceilings 125/140C 46.0 43.0 40.0 36.0 32.5 Temporary placement of control
box lid
Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.
Because the control box lid can be temporarily hung
Ease in temporary hanging
Standard Setting Setting Criteria for ceiling height and number of air discharge outlets
(Ceiling height is reference value) on the unit, there is no need to climb down the of decoration panel
stepladder to retrieve it. In addition to the temporary
Number of air discharge outlets used
50-71C 100–140C hanging fixtures in 2 places
3.6 4.2 All round 4-way 3-way 2-way All round 4-way 3-way 2-way normally used, corner part
3.2 m flow flow flow flow flow flow flow flow mounting fixtures in 4 places
m m
Standard 2.7 m 3.1 m 3.0 m 3.5 m 3.2 m 3.4 m 3.6 m 4.2 m are provided.
Ceiling
High ceiling 3.0 m 3.4 m 3.3 m 3.8 m 3.6 m 3.9 m 4.0 m 4.2 m Corner part mounting
height
High ceiling 3.5 m 4.0 m 3.5 m - 4.2 m 4.5 m 4.2 m - fixtures (in 4 places) Temporary hanging
fixtures (in 2 places)
Note:
Drain pump
When all round flow is selected, ceilings up to 4.2 m in height Factory settings are for standard ceiling height and all-round flow.
High ceiling settings (1) and (2) are set with the remote controller by field setting. The detached lid can
can be accommodated. (100-140C)
High-efficiency filters are not available for high ceiling applications. be hung on a hook.
Equipped as standard
accessory with
Humidity sensor
850 mm
850 mm lift.
Not only temperature but also humidity is
detected, and adjustments are made for
Installed in any direction 175 mm
comfortable air conditioning. Since the orientation of the suction grille can be
adjusted after installing, the direction of the suction
grille lines can be unified when multiple units are Transparent drain socket
Cleanliness installed.
every two to three years.) dust and moisture that adheres to the filters.
19 20
CEILING MOUNTED CASSETTE TYPE Round Flow
Ultra long-life filter unit Fresh air intake kit Note 1.2
Even in dusty environments where the air conditioning Using this kit, a duct can be connected to take in outdoor
is constantly operating, the ultra long-life filter only has air. There are two chamber types that have intake in two
to be cleaned once a year. places: with T-duct joint and without T-duct joint.
Filter chamber Outside
(Can be used with high-efficiency filter)
T-duct joint
Available in two types: 65% and 90% colorimetry. (obtained locally)
Suction
Filter chamber chamber Intake duct
(obtained locally)
(Can be used with ultra long-life filter) (duct length: 4 m max.)
Connection
chamber
KDDP55B160K
Please use if you think the temperature and humidity T-duct joint
inside the ceiling exceeds 30°C and RH 80%, Suction
chamber Intake duct
respectively. (obtained locally)
Connection (duct length: 4 m max.)
Top panel insulation(1) chamber
Top panel insulation(2) Direct installation type Note 6
Top panel insulation(3)
KDDP55X160A
Insulation for decoration panel
Side panel insulation
Suspension bracket insulation
drain water
hinder installation. Contact your
The drain outlet allows Note: 1. Use of options will increase operating sound.
Daikin Dealer before installing your
2. Connecting ducts, fan, insect nets, fire dampers, air filters, and other
Can be checked by removing the suction grille and insertion of a finger or 40mm
unit.
parts should, as required, be obtained locally.
drain plug. dental mirror for inspection Panel spacer 3. When a local-obtained fan is used, an interlock with air conditioner is
of the internal cleanliness necessary.Optional PCB (KRP1C11A) is required for interlocking.
of the drain pan. Removal
Sealing material of air discharge outlet
4. When installing a fresh air intake kit (chamber type), two air outlet
of the suction panel corners are closed.
5. It is recommended that the volume of outdoor air introduced through
enables access. Sealing material block air discharge openings not used the kit is limited to 10% of the maximum airflow rate of the indoor
in 2-way or 3-way blow. unit. Introducing higher quantities will increase the operating sound
and may also influence temperature sensing.
6. The volume of fresh air for direct installation type is approximately
Drain outlet 1% of the indoor unit airflow.
(with rubber plug) Ultra long-life filter (option) Branch duct The chamber type is recommended when more fresh air is
offices for up to four years. A round duct can be attached without the need for a
the chamber.
s t o pen lle! A flanged port for direct connection of a round duct is
Ju ri
ion g
suct
provided. An existing branch duct chamber can also be
Low gas pressure detection fitted (square slit hole).
21 22
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Design and Installation Flexibility
installation flexibility
with narrow ceiling spaces. range of 50 Pa to 150 Pa by using a DC fan motor.
245mm 50 Pa 150 Pa
NEW
One of the industry s most compact
FBA50/60/71/100/125/140BVMA Set to low static Set to high static pressure for
bodies in the mid-static pressure range. pressure when ducts advanced needs such as when
are short. using dampers and long ducts.
Indoor unit 50/60/71B 100/125/140B
Comfort airflow is achieved in accordance with conditions
Height (mm) 245
such as duct length.
Width (mm) 1,000 1,400
Depth (mm) 800
Inspection
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
Clean opening for
drain pan
Drain pan
When air conditioning two rooms
simultaneously, the air discharged into
Door-installed
ventilation grille
Wall-installed
ventilation grille Under-door cutout Silver ion anti-bacterial drain pan maintenance
check window
each room must be circulated back to A built-in antibacterial treatment that uses silver ion in the
the air conditioner. To achieve this, a drain pan prevents the growth of slime, bacteria, and mould
ventilation duct should be installed for Ventilates air through
Comfortable
installation
The unit fits more
snugly into tight
spaces.
30 mm
or more
30 mm
or more
25 26
WALL MOUNTED TYPE
Compact & Sophisticated Design Design and Installation Flexibility
easy installation
Height 360mm 340mm Left pipe
340
greater
mm Width 1,570mm 1,200mm
installation
1,200mm Depth 200mm 240mm
flexibility Back-left pipe
370mm shorter Weight 26kg 17kg Bottom-left pipe
NEW Back-right pipe
Right pipe
FAA100BVMA Bottom-right pipe
Auto swing (up and down) and wide-angle Drain pump kit is available as option
louvers (left and right by hand) Installs onto side of unit.
Refrigerant
piping
Wide-angle louvers (by hand) 1,000 mm
Soft material louver bends airflow over
a wider area
Option Indoor unit
Drain pump kit
Accessory required for indoor unit.
Drain pump kit can be installed on
Navigation Remote Controller either left and right side of the indoor
(Wired Remote Controller) An air discharge Auto-swing 5-level air direction setting
unit.
NEW modes ensure
BRC1E63 comfortable air
Note: Remote controller cable is not
distribution across Interlock control
the entire room
Adjustable to 5
included and must be obtained different levels
locally. As an energy saving feature, the room air
conditioning unit can be interlocked with the key card
system.
Easy Cleaning
Removable and Flat panel, easy to Non-flocking flaps
washable grille wipe dust off Condensation does not easily form
and dirt does not cling to non-flocking
flaps.
It is easy to clean.
27 28
OUTDOOR UNIT
Technology for energy efficiency
Compact Outdoor Unit
The high efficiency compressor to
achieve a high COP 3
RZF50CVM RZF125CVM
RZF71CYM RZF125CYM
RZF60CVM 1 Compressor equiped with reluctance DC motor
RZF100CVM RZF140CVM 2
RZF71CVM
RZF100CYM RZF140CYM Daikin DC Inverter models are equipped with the reluctance DC
motor for compressor.
The reluctance DC motor uses 2 different types of torque, neodymium 4
magnet*1 and reluctance torque*2. 1
This motor can save energy because it generates more power with a
Easy Installation and Maintenance smaller electric power than an AC or previous DC motor.
4-direction piping offers greater layout Facilitates pump down (Refrigerant recovery function) Reluctance
freedom (RZF125-140C) A pump-down switch is provided to make it easier to collect
Reluctance DC Motor
DC motor Swing compressor
Motor efficiency
The outer panel for the piping connection part of the front, refrigerant if the unit is to be moved or layout modified. High efficiency during partial load
right side and backside can be removed and is easier for *Pump-down function is available for pre-charged refrigerant amount.
DC motor
operation.
post-installation piping work. *Although pumping-down operation allows most of the refrigerant to be
More than 20%
recovered in a short period of time, some refrigerant will remain inside the Energy savings is realised,
indoor unit and refrigerant piping.
eliminating the friction and the
Removable part of bottom
Using a refrigerant recovery machine, recover remaining refrigerant from AC motor
the stop al e ser ice port until the pressure falls to . a. gauge leakage of refrigerant gas.
frame makes the piping
pressure . a or less.
Swing bushing
C 44
0
Rated
the printed circuit board and
Operation
2 Quiet mode
Reducing noise will reduce capacity slightly. 2 C 45 44 Quiet mode maintains high cooling capacity
1 C 8:00 12:00 16:00 20:00 0:00 4:00 8:00
even during high outdoor
Note : Anechoic chamber conversion value, measured according to JIS parameters 45
and criteria. Note : ai in date for C
temperatures.
Operating sound about d uieter
During operation these values are somewhat higher owing to ambient conditions.
2
Value when cooling. Value will differ when heating.
3 High efficiency by micro channel heat exchanger Reduced wind resistance
The flattening of the heat exchanger tubes
improves the flow of air and increases heat
Demand Control Function exchange efficiency.
consumption, you can cut electricity bills Limitation The diameter of the The diameter of the
consumption
4 Fan
V-cut Propeller Fan (RZF50-100C)
2 30
REMOTE CONTROLLER Optional accessory
Easy-to-read LCD remote controller allows various system control configurations and can control multiple indoor units.
Remote controller options are shown on the page introducing each indoor unit model.
BRC7M635F
Signal receiver unit
(For ceiling mounted cassette type)
Energy saving
Wireless remote controller for each indoor unit type
Setpoint auto reset Setpoint range set
Cooling only
- Even if the set temperature is changed, the new set temperature returns to the - Saves energy by limiting the
BRC7M635F (Fresh white)
previous preset value after a preset duration of time. min. and max. set temperature. NEW CEILING MOUNTED CASSETTE TYPE
BRC7M635K (Black)
- Period selectable from 30, 60, 90, or 120 min. - Avoids excessive heating or DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE BRC4C66
Restaurant example cooling. BRC7M56
NEW CEILING SUSPENDED TYPE
Restaurant opened Full tables at lunchtime After 30 minutes* - This function is convenient if WALL MOUNTED TYPE BRC7EB519
Temperature is set to 27ºC Then is lowered to 24ºC for Automatically returns to preset the remote controller is installed
crowded room temperature (27ºC) where anyone can change the
Returns to
settings.
27°C 24°C 27 °C
automatically
31 32
REMOTE CONTROLLER Optional accessory
For simultaneous
Group control control of up to 16
indoor units. Automatic address setting function Automatic address setting function
Signal receiver unit installed
on 1 indoor unit
Centralised control of
Centralised remote up to 64 indoor groups
control from remote location
up to 1 km away.
Interface adapter for SkyAir series (option) is Interface adapter for SkyAir series (option) is
required (See note 3) required (See note 3)
Note: 1BRC1E62 can connect to BRC1E62 only. BRC1E63 can connect BRC1E63 only. 2
When a wireless remote controller is used, it is not possible to use 2 wireless remote controllers.
Combination of BRC1E63 (main) and BRC7M (sub) is available.
Centralised control, with setting as Centralised control of on/off by Unified control of weekly schedule With its high functionality, the full
simple as it is with a standard group or all at once for up to 256 for up to 1,024 indoor units. colour “all-in-one” graphic controller
remote controller, of up to 64 groups indoor units. Schedule timer sets on/off time in 1 minute units facilitates management of SkyAir
(1,024 indoor units) is possible. to be executed twice a day for a week at a time. System in a variety of ways.
33 34
FUNCTIONS
CEILING MOUNTED DUCT CONNECTION MIDDLE CEILING SUSPENDED TYPE WALL MOUNTED TYPE
CASSETTE TYPE Round Flow STATIC PRESSURE TYPE
10 Circulation airflow *1 10
11 Setback *1 11
12 Quick start *1 12
13 Individual airflow control *1 13
14 Infrared presence sensor Sensing panel 14
15 Infrared floor sensor Sensing panel 15
16 Humidity sensor 16
17 Auto airflow function *1 Sensing panel 17
Comfort
18 Auto swing 18
19 Swing pattern selection 19
20 Switchable fan speed 5 step 5 step 20 3 step 3 step 5 step 5 step 3 step 3 step
30 Pre-charged for up to 30 m *3 30
31 Long-life filter 31 *6
37 Auto-restart 37
38 Control by 2 remote controllers *7 38 *7
46 High-efficiency filter 46
47 Ultra long-life filter 47
Options
48 Fresh air intake kit 48
49 Overvoltage PCB *3 49
Note: *1: Applicable when BRC1E63 is used *2: Not applicable when group control *3: For outdoor units *4: Adaptor for Wiring (and installation box) is necessary
*5: Wiring adaptor for electrical appendices (and installation box) is necessary *6: Option is requied *7: It is not possible to use 2 wireless remote controllers. Combination of BRC1E63 (main) and BRC7M (sub) is available.
35 36
FUNCTIONS
Cleanliness
Abundance of functions that provide comfortable 26. Anti-bacterial air filter 28. Silver ion anti-bacterial drain pan
air-conditioning in stores and offices The air filter has an anti-bacterial treatment to help prevent the
growth of bacteria and mould on it.
A built-in antibacterial treatment that uses silver ion in the drain pan
prevents the growth of slime, bacteria, and mould that cause odours
Note: Some features are only available on selected models. See overview pages for full list of features applicable to each unit. and clogging.
27. Mould-proof air filter
Energy Saving Sanitary filter has mould-resistant treatment.
Control
temperatures.
11. Setback
Maintains the room temperature in a specific range during 37. Auto-restart 41. External signal forced OFF and ON/OFF operation
unoccupied periods by temporarily starting an air conditioner that
If there is a power outage while the equipment is operating, The air conditioner can be interlocked with the keycard system and
had been turned OFF. 20. Switchable fan speed operations will restart in the same mode as before the power turned ON/OFF by locking and unlocking the room.
High setting provides maximum reach while low setting minimises drafts.
cut when electricity is restored. The air conditioner can be also be turned OFF by the interlock with
12. Quick start the ventilation and lighting OFF signal.
At operation start, capacity priority operation is possible. 21. Auto airflow rate 38. Control by 2 remote controllers *Field setting with remote controller.
Airflow rate is automatically controlled in accordance with the Using 2 remote controllers you can operate the equipment
13. Individual airflow control difference between room temperature and set temperature. locally or from a remote location. 42. External command control
Airflow direction can be individually adjusted for each air *When a wireless remote controller is used, it is not possible to use 2 Operation and monitoring is carried out using the contact signal from
discharge outlet to deliver optimal air distribution. wireless remote controllers. the operation control box in the building monitoring room.
22. High fan speed mode Combination of BRC1E63 (main) and BRC7M (sub) is available.
*Wiring adaptor for electrical appendices (and installation box) is necessary.
You can increase fan speed approximately 10% higher than the
14. Infrared presence sensor "high" setting. 39. Group control by 1 remote controller
The sensor detects the presence of people in each of the 4 areas. You can turn up to 16 indoor units ON/OFF with a single 43. Central remote control
remote controller. (When using connected indoor units, the Optional central remote controller enables centralised control of up to
23. Two selectable temperature-sensors settings must all be the same and on/off will be simultaneous.) 1024 indoor units (64 groups) from up to 1 km away.
15. Infrared floor sensor Temperature-sensors are included in
The sensor detects the floor temperature and automatically the indoor unit and optional wired 40. External equipment interlock 44. Interlock control with Heat Reclaim Ventilator
adjusts operation of the indoor unit to reduce the temperature remote controller. Temperature sensing Human presence is detected by the built-in infrared presence
closer to target area is possible to Enables interlocking control with external equipment such as Heat
difference between the ceiling and the floor. sensor in the sensing panel, and the presence detection
further increase the comfort level. Reclaim Ventilator.
signal can be output and interlocked with external equipment.
Use the temperature-sensor in the indoor unit when
16. Humidity sensor Power conservation is possible though the interlock of
Not only temperature but also humidity is detected, and
controlling air conditioning from another room. external equipment, such as lighting, with the infrared 45. DIII-NET communication standard
Note: Wireless remote controllers have no temperature-sensor. presence sensor. Connection to a centralised control system is available
adjustments are made for comfortable air conditioning.
*Adaptor for Wiring (and installation box) is necessary. without need for an optional adaptor.
37 38
SPECIFICATIONS
CEILING MOUNTED CASSETTE TYPE ( 1 Phase ) DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE ( 1 Phase )
50 60 71 100 125 140 50 60 71 100 125 140
Indoor unit FCF50CVM FCF60CVM FCF71CVM FCF100CVM FCF125CVM FCF140CVM Indoor unit FBA50BVMA FBA60BVMA FBA71BVMA FBA100BVMA FBA125BVMA FBA140BVMA
Model Model
Name Outdoor unit Name Outdoor unit
RZF50CVM RZF60CVM RZF71CVM RZF100CVM RZF125CVM RZF140CVM RZF50CVM RZF60CVM RZF71CVM RZF100CVM RZF125CVM RZF140CVM
Power supply Outdoor unit 1 Phase, 220–240V, 50Hz Power supply Indoor unit 1 Phase, 220–240V, 50Hz
Cooling Capacity 1,2 5.0 6.0 7.1 10.0 12.5 14.0 Outdoor unit 1 Phase, 220–240V, 50Hz
Rated (Min. - Max.) kW (3.2-5.6) (3.2-6.0) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
Cooling Capacity 1,2 5.0 6.0 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-5.6) (3.2-6.0) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
17,100 20,500 24,200 34,100 42,700 47,800
Btu/h (10,900-19,100) (10,900-20,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900) 17,100 20,500 24,200 34,100 42,700 47,800
Btu/h (10,900-19,100) (10,900-20,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Power consumption Cooling kW 1.14 1.53 1.93 2.97 4.18 5.47
COP W/W 4.39 3.92 3.68 3.37 2.99 2.56 Power consumption Cooling kW 1.35 1.64 2.15 3.01 4.44 5.69
CSPF Wh/Wh 6.60 6.31 6.17 5.50 5.15 5.00 COP W/W 3.70 3.66 3.30 3.32 2.82 2.46
Indoor unit Colour Unit ---------- CSPF Wh/Wh 5.51 5.30 5.19 4.88 4.70 4.47
Decoration panel Fresh white Indoor unit Colour ----------
Airflow rate 3
m /min 23.0 / 21.0 / 18.5 / 16.0 / 13.5 34.5 / 31.0 / 27.5 / 24.0 / 20.0 36.5 / 33.0 / 29.0 / 25.0 / 21.0 Fan Airflow rate (H/M/L) m3/min 18.0 / 15.0 / 12.5 23.0 / 19.5 / 16.0 32.0 / 27.0 / 22.5 36.0 / 30.5 / 25.0
(H / HM / M / ML / L) cfm 812 / 741 / 653 / 565 / 477 1,218 / 1,094 / 971 / 847 / 706 1,288 / 1,165 / 1,024 / 883 / 741 cfm 635 / 530 / 441 812 / 688 / 565 1,130 / 953 / 794 1,271 / 1,077 / 883
Sound pressure level 3 (H / HM / M / ML / L) dB(A) 37.0 / 34.5 / 32.0 / 29.5 / 27.5 45.0 / 41.5 / 38.0 / 35.0 / 32.5 46.0 / 43.0 / 40.0 / 36.0 / 32.5 External static pressure 3 Pa Rated 50 (50-150)
Dimensions Unit mm 256X840X840 298X840X840 Sound pressure level 4 (H/M/L) dB(A) 35.0 / 33.0 / 31.0 38.0 / 35.0 / 33.0 40.0 / 37.5 / 35.0
(HXWXD) Decoration panel mm 50X950X950 Air filter 5 ----------
Machine Unit kg 22 24 Dimensions (HXWXD) mm 245X1000X800 245X1400X800
weight Decoration panel kg 5.5 Machine weight kg 37 47
Certified Operation range °CWB 14 to 25 Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white Outdoor Colour Ivory white
unit Coil Type Micro channel unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type Compressor Type Hermetically sealed swing type
Motor output kW 1.30 1.60 2.40 Motor output kW 1.30 16.0 2.40
Refrigerant charge (R32) kg 1.2(Charged for 30 m) 1.3(Charged for 30 m) 1.9(Charged for 30 m) Refrigerant charge (R32) kg 1.2(Charged for 30 m) 1.3(Charged for 30 m) 1.9(Charged for 30 m)
Sound Cooling dB(A) 48 49 52 54 Sound Cooling dB(A) 48 49 52 54
pressure level 3 Night quiet mode pressure level 4
dB(A) 44 45 Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 695X930X350 990X940X320 Dimensions (HXWXD) mm 595X845X300 695X930X350 990X940X320
Machine weight kg 41 48 64 Machine weight kg 41 48 64
Certified Operation range °CDB 21 to 46 Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5 Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9 connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32) Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Outdoor unit mm 26.0 (Hole) 18.0 (Hole) 26.0 (Hole) Outdoor unit mm 26.0 (Hole) 18.0 (Hole) 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70) Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30 Max. installation level difference m 30
Heat insulation Both liquid and gas piping Heat insulation Both liquid and gas piping
39 40
SPECIFICATIONS
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
41 42
OPTIONS OPTIONS
Round flow type: List of optional parts required to achieve different flow patterns
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
43 44
OPTIONS
Indoor unit
CEILING SUSPENDED TYPE
No. Kit name
Name of option Remark
FHA50BVMA FHA60BVMA FHA71BVMA FHA100BVMA FHA125BVMA FHA140BVMA
1 Replacement long-life filter Resin net KAFP501A56 KAFP501A80 KAFP501A160
2 Fresh air intake kit KDDQ50A140
3 Drain pump kit KDUP50Q160
4 L-type piping kit (for upward direction) KHFP5N160
5 Remote controller Wireless type Cooling only BRC7M56
6 Navigation Remote Controller Wired type 1 BRC1E63
7 Central remote controller 2 DCS302CA61
8 Unified ON/OFF controller 2 DCS301BA61
9 Schedule timer 2 DST301BA61
10 intelligent Touch Controller 2 DCS601C51
11 Adaptor for wiring 3 KRP1BA54
12 Wiring adaptor for electrical appendices 3 KRP4AA52
13 Installation box for adaptor PCB KRP1D93A
14 Adaptor box mounting plate KKSAP50A56 ----------
15 Remote sensor (for indoor temperature) KRCS01-4B
16 Electrical box with earth terminal (3 blocks) KJB311AA
17 Electrical box with earth terminal (2 blocks) KJB212AA
Note:
1
Wiring for wired remote controller should be obtained locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP1D93A) is necessary.
Outdoor unit
Kit name
No. Name of option 1 Phase RZF50/60/71CVM RZF100CVM RZF125/140CVM
3 Phase ---------- RZF71/100CYM RZF125/140CYM
1 Central drain plug KKP014A4 KKP937A4 KKPJ5G280
2 Fixture for preventing overturning ---------- ---------- KKTP5B112
3 Wire fixture for preventing overturning ---------- ---------- K-KYZP15C
4 Demand adaptor ---------- KRP58M51 KRP58M51+EKMKSA1
Overvoltage PCB 1 Phase BRV2BPSF BRV2BPSS BRV2BPL
5
3 Phase ---------- BRV2BPSS+BRV2BPSS
45 46