Professional Documents
Culture Documents
Certificado IP TE
Certificado IP TE
,�,
Report No.: CNB3121128-0045 Page 1 of 18 Date: 13 December 2020
Table of contents
1. General lnformation 2
1.1 Notes 2
1.2 Tester 3
1. 3 Testing laboratory 4
1.4 Application details 4
1.5 Test item description 5
1.6 Test standards 6
2. Technical test 7
3. Test Results 9
3.4 table 17
Attachments 19
CEN'tRE OF TEStlNG SER\IICE
1 General lnformation
1.1 Notes
The test results of this test report relate exclusively to the item tested as specified in 1.5.
The test report may only be reproduced or published in full.
Reproduction or publication of extracts from the report requires the prior written approval
of the Centre of Testing Service.
CEN'tRE OF TEStlNG SER\IICE
1.3.1 Location
CTS (Ningbo) Testing Service Technology Co., Ud.
FI. 2 South Huoju Building No. 181 . Canghai Rd. Jiangdong High-tech. Park
Ningbo China
Contad :/
Telephone :. +86-577-61778330
CEN'tRE OF TEStlNG SER\IICE
Contact :/
Telephone :. +86-577-61778330
1.4.3 Details of factory
Name :NIUDUN GROUP C ORPORATION LIMITED
Street : XINGUANG INDUSTRIAL ZONE
Town :LIUSHI ,WENZHOU,ZHEJIANG
Country : CHINA
1 .6 Test standards
2 Technical test
2.1 Summary of test results
Temperature: 15 ... 25 ºe
Relative humidity content: 20 ... 75 %
Other parameters:
CEN'tRE OF TEStlNG SER\IICE
General remarks:
"(see remark #)" refers to a remark appended to the report.
The test results presented in this report relate only to the object tested.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
CENtRE OF TEStlNG SER\IICE
4 Designations
4.1 Arrangement of the IP code IP66 p
lll
::::
Degrees of protection against access to hazardous parts and against solid
5 :•::::
foreign objects indicated by the first characteristic numeral ·'·'·'
...
6 Degrees of protection against ingress of water
indicated by the second characteristic numeral 11: +
::::::
8 l supplementary letters N
10 Marking 1 :::::;
:::: :
12
12.1
Tests for protection against access to hazardous parts indicated by the first
characteristic numeral
Ac cess probes, see the table VI
11 p
:;:;:;
.,.,.,
k... ·······
L
Tests for protection against solid foreign objects indicated by the first ••••••
13
characteristic numeral +
13.1 Test means must comply with Table VII. See attached table p
13.2 AII appliances IP6X p
the probe shall not penetrate in the appliance when the
p
orobe is aoolied with the force:
A (sphere diameter 50mm with 50N far IP 1X ) N
B (sphere diameter 12,5mm with 30N far IP 2X) N
e (stick diameter 2,5 mm with 3N far IP 3X) N
o (wire diameter 1,0 mm with 1N far IP 4X) N
Acceptance conditions far the first characteristic
13.3 N
numerals 1,2,3,4
The probe does not pass through any opening N
13.4 Dust test far first numeraIs 5 and 6 IP6X p
-Dust test condition far enclosures category 1: With sup-
atmosphere N
·: -•-•-•
·····
1
Tests for protection against water indicated by the second characteristic
14
numeral •-•-•-•
14.1 Test means, see the Table VIII See attached table p
14.2 Test conditions must comply with Table VIII p
14.2.1 Proof with the drop machine (IP X1) IPX6 N
test far 1O min with a water - volume -stream of 1 mm/min
on a rotating table (1 round/min distance between N
aooliance and the axis of the table is 100mm)
-the ingress of water shall not impair safety or interfere
N
with the correct operation of equipment
-the water shall not cause tracking currents N
CENtRE OF TEStlNG SER\IICE
c1ausé :':'"
........... ..,
. ...,.,..,
. ..
·:· :.:....:
::: ; verdict
. . ..,..................,.,....
-the water shall not reach live parts or winding which are
N
not build far use in wet conditions
-the water shall not reach the end of wires N
-if the case is provided with drainage hales water shall
N
not stav in the case and flow without impairina safetv
-the equipment pass the dielectric strength test N
14.2.2 Proof with the drop machine (IP X2) IPX6 N
test far 1 O min with a water - volume -stream of 3mm/min
on a rotating table (1 round/min distance between N
aPPIiance and the axis of the table is 100mm)
test far 2,5 min at 4 fixed positions with 15 º slope N
-the ingress of water shall not impair safety or interfere
N
with the correct operation of equipment
-the water shall not cause tracking currents N
-the water shall not reach live parts or winding which are
N
not build far use in wet conditions
-the water shall not reach the end of wires N
-the equipment pass the dielectric strength test N
-if the case is provided with drainage hales water shall
N
not stay in the case and flow without impairinq safety
14.2.3 Proof with the sprinkling machine (IP X3) IPX6 N
Testing not less than 5min from - 60 to 60 degree jet
angle at 0,07 l /min per hale with a distance of 200mm a
N
shower at 1 O l /min, and the water pressure range of
50kPa to 150kPa.
The test duration is 1 min/m2 N
-the ingress of water shall not impair safety or interfere
N
with the correct operation of eauipment
-the water shall not cause tracking currents N
-the water shall not reach live parts or winding which are
N
not build far use in wet conditions
-the water shall not reach the end of wires N
-if the case is provided with drainage hales water shall
N
not stay in the case and flow without impairinq safety
-the equipment pass the dielectric strength test N
14.2.4 Proof with the sprinkling machine (IP X4) IPX6 N
Testing not less than 5min from - 180 to 180 degree jet
angle at 0,07 l /min per hale with a distance of 200mm a
N
shower at 1 O l /min, and the water pressure range of
50kPa to 150kPa.
CENtRE OF TEStlNG SER\IICE
c1ausé :':'"
........... ..,
. ...,.,..,
. ..
·:· :.:....:
::: ; verdict
. . ..,..................,.,....
c1ausé :':'"
........... ..,
. ...,.,..,
. ..
·:· :.:....:
::: ; verdict
. . ..,..................,.,....
3.4 Table
Table V -test conditions for degrees of protection indicated by the first characteristic numeral
Table VII- test means for the tests for protection against salid foreign objects
First characteristic Test means(object probes and dust Test force Test conditions see
numeral chamber
o No test required
1 Rigid sphere without handle or guard 50N±10% 13.2
O&
SO +o,
o mm diameter.
2 Rigid sphere without handle or guard 30N±10% 13.2
2
126+0,
, o mm diameter.
3 Rigid steel rod 2-5\' mm diameter 3N±10% 13.2
with ed es free from burrs
4 Rigid steel wire 1.0mm diameter with 1N±10% 13.2
ed es free from burrs
5 Dust chamber figure 2, with or without - 13.4+13.5
under ressure
CENtRE OF TEStlNG SER\IICE
Table VIII- test means and main test conditions for the tests for protection against water
Attachments
D Photo document
□ BOM
D I nstruction manual
D Circuit diagram
D Explosion block
� Other if necessary