Supply Systems
AC switchgear / DC rectifier
Contents
04 High Voltage Products
06 AC Medium Voltage Products
13 AC Low Voltage Products
14 SCADA
16 DC Medium Voltage Products
17 E-House
18 Global Network
LS is a leading company in the railway and power fields and paving the way in order to build
a stable infrastructure and to create a productive business environment.
LS, which has the best experience in the railway system industry, has improved safety
and reliability based on accumulated electrical, electronic, and information technology.
We offer the best railway solution to our customers both at home and abroad.
We provide integrated power solutions by establishing a complete system from ultra-high pressure
to power distribution in the area of railway power transmission.
Based on reliable, integrated power distribution solution technology, it is optimized and safe
to install facilities, adding convenience to railway operation.
AC or DC related power facilities are supplied in batches to substations and tracks
for easy maintenance and electrical facility management and operation.
We also offer services to reduce the possibility of setbacks in railway infrastructure.
LS ensures complete performance and improve the economics of transportation and installation.
We supply ultra-high voltage GIS and transformers, which are large power facilities,
with compact and lightweight products. We strive to provide the best quality products for stable
operation of railway power facilities.
The world-class test environment is built within the ultra-high voltage testing room to ensure
product performance and to meet IEC and ANSI standards.
Rated voltage (kV, rms) 72.5 145 170 245 362 420
Rated making current (kA, peak) 52 79/82 100/104 130 100/104 125 130 164 125
Power Common (kV, rms) 140 275 325 460 520 650
frequency
withstand Across the
voltage (kV, rms) 160 315 375 530 675 815
isolating distance
Lightning Common (kV, peak) 325 650 750 1050 1175 1425
impulse
withstand Across the
voltage (kV, peak) 375 750 860 1200 1175 1425(+240)
isolating distance
CB Hydraulic Motor spring Motor spring Hydraulic Motor spring Hydraulic Hydraulic
Operating
DS Motor Motor Motor Motor Motor Motor
Mechanism
Manual /
ES Manual Motor Motor spring Motor / Motor spring Manual / Motor spring Motor
Motor spring
IEC 62271-102
Applicable standards IEC 62271-100 / IEC 62271-102 / IEC 62271-203
IEC 62271-203
04
High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House
Power transformer
Winding types and methods that offer minimum loss were selected using magnetic field analysis, and also
used in the LS power transformer to ensure high levels of efficiency. Moreover, by selecting the optimal
insulating structure through the electric field analysis of insulation between turns, sections, windings and
phases, the power transformer electrical stability is achieved. LS fluent analysis technology has enabled
the an optimal cooling system, and 3D structure strength analysis has enabled a structural design that can
withstand internal mechanical power short-circuits caused by system faults, seismic conditions according
to external impacts and any impact during transportation.
LS power transformer factory is equipped with the latest core processor machines, the latest winding
machines, high-capacity vacuum heat drying equipment, state-of-the-art cleaning facilities and testing
room.
Cooling Internal ON / OF / OD
method External AN / AF / WF
Oil preservation systems Conservator type / N2 sealing type / Air seal cell type
Special purpose Scott connection / Electric furnace / Shunt reactor / HVDC converter transformer
Scott transformer
LS scott transformer is a special transformer that can obtain 2 phase (2 phase, 90° phase difference) output from 3
phase (3 phase, 120° phase difference) power supply.
This transformer is used for special purposes such as when using a large-capacity single-phase load as a three-
phase power supply.
LS scott transformers are mainly used for railway supply line in domestic market and 3 phase power is converted
into 2 phases and divided into upper and lower lines.
In contrast to a conventional scott transformer consisting of two active parts, LS transformer can be configured as
one active part, which has advantages such as compact size, weight and competitive price.
05
AC Medium Voltage Products
LS has the high-pressure product, line up, for economical and innovative operation of the
railway supply system.
To ensure the best quality while ensuring the products are tailored to the various customer
needs.
We are committed to making the high-pressure products highly available for economical
installation and operation.
To increase efficiency, we developed products actively.
Based on various business experiences at home and abroad, it is not only equipped with
elements necessary to operate the railway power system.
We are trying to lead the market trend by developing products to comply with eco-friendly
policies.
Standard specifications
Section
GESG 0332 / 0331-TC GESG 0243-NC GESG 0342-NC
Operating sequence O-0.3 sec-CO-15 sec-CO O-0.3 sec-CO-3 min-CO O-0.3 sec-CO-3 min-CO
06
High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House
Short-time withstand current (kA/s) 25/3 40/3 50/3 25/3 40/3 25, 31.5, 40/3
Internal arc withstand current (kA/s) 25/1 40/1 50/0.5 25/1 40/0.5 40/1
07
AC Medium Voltage Products
Practicality
•APR, AEC and AE are arranged in a panel
•Possible to connect Relay with LS MCSG for having same structure with existing LS MCSG
•Possible to have an economical arc protection performance by installing APM
Arc Protection
Expandability
Slave Unit
•Possible to detect an internal arc flash by installing sensors in other panels as well as APS dedicated panels
•Extra light sensor installation by connecting slave units
- Maximum number of slave units : 3ea
- Maximum number of sensors : Point sensor - 30ea, loop sensor - 12ea
Arc Eliminator
Safety
•Arc extinguishment by bypassing the arc current within 5 ms after an arc fault
minimize the spread of accident
Arc Eliminator Controller
•CB trip signal output within 15 ms after an arc fault and power system separation
•Prevention of AE manual insertion caused by user's mistake(Electric return possible)
•KERI and KC certification based on KOEMA 0930, 0931, 0932, standards
※ APR : Arc Protection Relay, AEC : Arc Eliminator Controller, AE : Arc Eliminator, APM : Arc Protection Module
APS panel 구성
Arc Protection Relay Slave Unit Arc Eliminator Arc Eliminator Controller
08
High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House
Insekation level
Breaking capacity
Internal arc calssification (kA/1s) 21 (A-FLR) : Option 21 (A-FLR) : Option 21 (A-FLR) : Option
09
AC Medium Voltage Products
installable
Detachable Detachable
LA LA
Detachable
LA
Configurable Configurable
10
High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House
Frequency 60
F6900-R6600-6300-6000-5700
1st tap voltage (kV) F23900-R22900-21900-20900-19900
F3450-R3300-3150-3000-2850
Phase 3P 3P 1P 3P 1P
11
AC Medium Voltage Products
Option components
Digital thermometer/ Controller
Cooling fan
Low noise cooling fan Large cooling fan Sliding cooling fan
Uninterrupted replacement
Other accessories
•Reducing the magnetic flux density and loss •Heat and noise reduction in the core
•Reducing wind temperature of the conductor •Prevention of loss due to overheating of coils
•Using thin conductor •Eddy loss reduction
•Installing an electro-magnetic shield •Common mode harmonic reduction
•Reinforcement of coil insulation strength •Prevention of spike voltage
12
AC Low Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House
LS Low Voltage Switchgear provides optimized solution to meet various customer's needs.
It is designed and produced to construct high quality power systems in all kinds of industrial
field. It realizes compact size and also secures customer's convenience and safety.
Standard IEC 61439-1 & 2 IEC 61439-1 & 2 IEC 61439-1 & 2
* MCC unit for IP54 is fixed type only.
13
SCADA
SCADA is a system that remotely monitors and controls the power facilities installed in the
power system.
It is a system for stable and highly reliable operation through real-time acquisition of power
data analysis, data trend analysis and operator-oriented control.
User-oriented Standardization
•GUI configuration of familiar Windows technologies •Data access and presentation through the same interface
and environments •Supports industry standards such as 3rd party activeX,
•Support various applications such as power excel, and reports
equipment diagnosis, power quality monitoring, •Operate a unified interface between operator and system
facility protection, and substation automation. •Supports system integration engineering tool
Delivery performance
•Outline│ Honam high speed rail integrated SCADA project(2014~)
•Feature │ Gyeongbu high speed railway 1 & 2 stage, Honam metropolitan area high-speed railway section,
substation / category / electric room /
electric power facility monitoring(RTU: 524) and general / wide-area railway substation / category /
monitoring of electric room power facilities(RTU: 941) SCADA construction business
14
High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House
•PQ data acquisition and application : PQ data acquisition, real time events, PQ event occurring trend analysis
•PQ analysis : 3D voltage event analysis, sag / swell analysis,
CBEMA and other statistical analysis, on / off line power quality analysis
•On-line monitoring diagnosis : Indication of abnormality for each diagnosis category of TR and GIS for each Bay,
GIS PD measurement and 2D / 3D analysis screen, real time event and information screen indication,
real time communication condition
•Convenience of operator : - Monitoring screen editing - Communication device on-line setting
•Preventive diagnosis analysis : - Precise diagnosis of gas in liquid for specialized DB base
•Remote monitoring and control : - Operating status of circuit breakers / relays - Circuit breakers remote control
- Multi-level fluctuation control of the power generator
•IED analysis /correction : - Relay / logic operational status - Relay remote setting
•Harmonic / accident waveform analysis
•Protective function(IED) : Power generator / bay and line / transformer / breaker / motor protection
15
DC Medium Voltage Products
LS provides not only AC but also DC systems, which are essential for operating railway
facilities.
DC switchgears and DC rectifiers can be provided to meet customer needs and are committed
to stable railway operation.
DC switchgear
DC switchgear is designed to protect the DC powered railway line and integrated with high speed circuit
breakers for the rectifier, the power feeder and the backup application to prevent safety incidents.
DC rectifier
The free convention and silicon-based rectifier is designed to convert AC to DC.
Its large capacity and compact design ensures the reduction of space required for railway system installation.
16
Smart E-House High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House
UPS HVAC
E-House
Transformer Fire Fighting System
Section Canada E-House PJT Iraq mobile substation PJT Chile cochrane PJT
132/33kV mobile substation Chile cochrane thermoelectric power plant
Project Canada E-House
(S&P WORLD NETWORKS) (POSCO Construction)
etc. 132kV DS, CB, Power TR, 33kV MCSG, RCP Installation of internal pressure-proof equipment
Canada E-House Iraq mobile substation Chile cochrane thermoelectric power plant
17
Global LS is engaged in business all over the world.
LS global network includes 7 overseas corporations,
Network 12 overseas branches, and 224 clients in 77 countries.
▶R&D ▶Factory
R&D campus Power device R&D center Automation R&D Center PT&T (Testing laboratory) Cheongju factory (Korea)
Focuses on gaining competitive Leading technology in electric Serves as the main research institute Internationally-renowned testing Electric products, mold TR, MV/LV
advantages through development industry and continuously developing for LS center that has formed partnerships switchgear, HV GIS
of next generation platforms future-growth dynamic engines with the UL, CE, KEMA and CESI
18
Head office
Domestic business establishment
Busan
Busan factory
Cheonan factory (Korea) Busan factory (Korea) Wuxi factory (China) Dalian factory (China) Hanoi factory (Vietnam)
PLC, AC drive, HMI, DCS, PV module HV TR, HVDC, FACTS Electric products MV/LV switchgear, MV/LV switchgear,
MV contactor Mold TR
19
www.lselectric.co.kr
2020. 04 2019. 03. LS ELECTRIC Co.,Ltd. All rights reserved. / (01) 2020. 04. PACO STORY