You are on page 1of 20

LS Railway

Power
Supply Systems

High voltage gas insulated switchgear

AC switchgear / DC rectifier

Contents
04 High Voltage Products
06 AC Medium Voltage Products
13 AC Low Voltage Products
14 SCADA
16 DC Medium Voltage Products
17 E-House
18 Global Network
LS is a leading company in the railway and power fields and paving the way in order to build
a stable infrastructure and to create a productive business environment.
LS, which has the best experience in the railway system industry, has improved safety
and reliability based on accumulated electrical, electronic, and information technology.
We offer the best railway solution to our customers both at home and abroad.

We provide integrated power solutions by establishing a complete system from ultra-high pressure
to power distribution in the area of railway power transmission.
Based on reliable, integrated power distribution solution technology, it is optimized and safe
to install facilities, adding convenience to railway operation.
AC or DC related power facilities are supplied in batches to substations and tracks
for easy maintenance and electrical facility management and operation.
We also offer services to reduce the possibility of setbacks in railway infrastructure.

High voltage gas insulated switchgear

High voltage power transformer / Scott transformer


High Voltage Products

LS ensures complete performance and improve the economics of transportation and installation.
We supply ultra-high voltage GIS and transformers, which are large power facilities,
with compact and lightweight products. We strive to provide the best quality products for stable
operation of railway power facilities.
The world-class test environment is built within the ultra-high voltage testing room to ensure
product performance and to meet IEC and ANSI standards.

High voltage GIS (Gas Insulated Switchgear)


LS indoor or outdoor GIS are generally selected for various types of power plants and substations to satisfy
customer needs. By opening and closing the circuit breaker under normal and fault condition, customer can
prevent & protect the implemented facilities over the whole system.
LS GIS complies with the latest international standards & requirement by performing global test laboratory
within the range from 25.8kV to 420kV. LS compact size of GIS is comparable with other manufactures
equipment within the same rating and we can provide economical & feasible solutions for the customers
who has only limited space for GIS.

Section Standard specifications

Rated voltage (kV, rms) 72.5 145 170 245 362 420

Rated short-time current (kA, rms) 20 31.5 40 50 40 50 50 63 50

Rated short-time (sec) 1 3 3 1 3 1 1 3

Rated breaking current (kA, rms) 20 31.5 40 50 40 50 50 63 50


1250, 2000
Rated current (A, rms) 2000 ~ 3150 up to 3150 4000 ~ 6300 4000
3150, 4000
Rated frequency (Hz) 60 50/60 50/60 60 50/60 50 60 50

Rated making current (kA, peak) 52 79/82 100/104 130 100/104 125 130 164 125

Rated breaking time (Cycle) 3 3 3 3 3 2

Power Common (kV, rms) 140 275 325 460 520 650
frequency
withstand Across the
voltage (kV, rms) 160 315 375 530 675 815
isolating distance
Lightning Common (kV, peak) 325 650 750 1050 1175 1425
impulse
withstand Across the
voltage (kV, peak) 375 750 860 1200 1175 1425(+240)
isolating distance

Rated operating sequence O - 0.3 sec - CO - 3min - CO

2 Phase 3 Phase 3 Phase 3 Phase Single phase


Busbar 3 Phase encapsulate 3 Phase encapsulate
Phase encapsulate encapsulate encapsulate encapsulate segregated
arrangem
ent 2 Phase 3 Phase 3 Phase 3 Phase Single phase Single phase Single phase
Feeder
encapsulate encapsulate encapsulate encapsulate segregated segregated segregated

CB Hydraulic Motor spring Motor spring Hydraulic Motor spring Hydraulic Hydraulic
Operating
DS Motor Motor Motor Motor Motor Motor
Mechanism
Manual /
ES Manual Motor Motor spring Motor / Motor spring Manual / Motor spring Motor
Motor spring
IEC 62271-102
Applicable standards IEC 62271-100 / IEC 62271-102 / IEC 62271-203
IEC 62271-203

04
High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House

High voltage power transformer / Scott transformer

Power transformer
Winding types and methods that offer minimum loss were selected using magnetic field analysis, and also
used in the LS power transformer to ensure high levels of efficiency. Moreover, by selecting the optimal
insulating structure through the electric field analysis of insulation between turns, sections, windings and
phases, the power transformer electrical stability is achieved. LS fluent analysis technology has enabled
the an optimal cooling system, and 3D structure strength analysis has enabled a structural design that can
withstand internal mechanical power short-circuits caused by system faults, seismic conditions according
to external impacts and any impact during transportation.
LS power transformer factory is equipped with the latest core processor machines, the latest winding
machines, high-capacity vacuum heat drying equipment, state-of-the-art cleaning facilities and testing
room.

Section Standard specifications

Applicable standard IEC 60076 / ANSI(IEEE) C57

Installation location Outdoor / Indoor

Frequency (Hz) 50/60

Insulation (°C) Oil type

Thermal class 105 (A)

Cooling Internal ON / OF / OD
method External AN / AF / WF

Up to 800 for three phase


Capacity (MVA)
Up to 500 for single phase

Oil preservation systems Conservator type / N2 sealing type / Air seal cell type

Base Skid / Roller

Voltage (kV) Up to 500

Application Generation plant (GSU) / Substation / Transmission & distribution

Special purpose Scott connection / Electric furnace / Shunt reactor / HVDC converter transformer

Scott transformer
LS scott transformer is a special transformer that can obtain 2 phase (2 phase, 90° phase difference) output from 3
phase (3 phase, 120° phase difference) power supply.
This transformer is used for special purposes such as when using a large-capacity single-phase load as a three-
phase power supply.
LS scott transformers are mainly used for railway supply line in domestic market and 3 phase power is converted
into 2 phases and divided into upper and lower lines.
In contrast to a conventional scott transformer consisting of two active parts, LS transformer can be configured as
one active part, which has advantages such as compact size, weight and competitive price.

05
AC Medium Voltage Products

LS has the high-pressure product, line up, for economical and innovative operation of the
railway supply system.
To ensure the best quality while ensuring the products are tailored to the various customer
needs.
We are committed to making the high-pressure products highly available for economical
installation and operation.
To increase efficiency, we developed products actively.
Based on various business experiences at home and abroad, it is not only equipped with
elements necessary to operate the railway power system.
We are trying to lead the market trend by developing products to comply with eco-friendly
policies.

C-GIS (Cubicle type Gas Insulated Switchgear)


LS cubicle type gas insulated switchgears meet the electric system requirements of increasing capacity
according to customer needs for large plants. The design and constitution of our GIS offer high reliability,
safety and convenience in such a compact size. LS adopts procedures for production, delivery and technical
service which are fully environment-friendly under control of ISO 14001 for our future generation, which
include minimizing the use of SF6 gas.

Standard specifications
Section
GESG 0332 / 0331-TC GESG 0243-NC GESG 0342-NC

Rated voltage (kV, rms) 36 25.8 36

Rated normal current (A, rms) 1250/2500 1250/3150 1250/2500


Power frequency
(kV, rms) 70 70 70
withstand voltage
Lightning impulse
(kV, peak) 170 150 170
withstand voltage
Single busbar Rated frequency (Hz) 50 50/60 50/60
Rated short-circuit
(kA, rms) 31.5 40 40
breaking current
Rated break time (Cycle) 5 5 5

Operating sequence O-0.3 sec-CO-15 sec-CO O-0.3 sec-CO-3 min-CO O-0.3 sec-CO-3 min-CO

CB Motor spring Motor spring Motor spring


Operating
DS Motor Motor Motor
mechanism
ES Motor Motor Motor

Rated gas pressure (kgf/cm2·G) 0.5 1.0 1.0

Minimum gas pressure (kgf/cm ·G)


2 0.4 0.8 0.7
Double busbar
Busbar system Single Single / Double Single / Double

Applicable standards IEC-62271-1 / IEC-62271-100 / IEC-62271-102 / IEC-62271-200

Size (W×D×H, mm) 600×1550×2400 700×2095×2550 700×2095×2550

06
High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House

Medium voltage MCSG (Metal Clad Switchgear)


LS medium voltage MCSG has the best protection rating out of air insulated switchgears. We can provide the
solutions that customers want by having full line-up to the high capacity models. The installation area of MCSG can
be reduced by up to 64% compared to our existing switchgears to provide room for space.
Each compartment is divided by metal partitions, and this structure can remove damage to peripheral devices in
case of an internal arc accident. Also, various accessories and mechanical interlocks are applied for increasing user
safety. We have demonstrated reliability and safety through certification of international certified testing institutions
based on international standards.

Section Standard specifications

Rated voltage (kV, rms) 7.2 12 17.5 24 36

Model (Solution power series) S7 S12 S17 S24 S36


Power frequency
(kV, rms) 20 28 38 50 70
withstand voltage
Lightning impulse
(kV, peak) 60 75 95 125 170
withstand voltage 1)

Short-time withstand current (kA/s) 25/3 40/3 50/3 25/3 40/3 25, 31.5, 40/3

Degree of protection IP4X IP4X IP4X IP4X IP4X IP4X

Internal arc withstand current (kA/s) 25/1 40/1 50/0.5 25/1 40/0.5 40/1

630 1250/2000 1250 1250


(A, rms) 1250/2000 630/1250
Rated current 1250 2500/3150 2000 2000
3150/4000 2000/2500
2000 4000/5000 2) 3150 3150

1) These can be applied to S7, S12 and S17 model in common.


2) 5000A can be applied to S7,S12 model.

07
AC Medium Voltage Products

APS (Arc Protection System)


LS APS actively protects users and power equipment by detecting an arc within a short time in case of an
internal arc accident inside the switchgear and extinguishing the arc.

Practicality
•APR, AEC and AE are arranged in a panel
•Possible to connect Relay with LS MCSG for having same structure with existing LS MCSG
•Possible to have an economical arc protection performance by installing APM
Arc Protection

(X-GIPAM arc protection module)


•Minimum number of AE operation : Arc quenching - 2 times, mechanocal life - 10 times

Expandability
Slave Unit

•Possible to detect an internal arc flash by installing sensors in other panels as well as APS dedicated panels
•Extra light sensor installation by connecting slave units
- Maximum number of slave units : 3ea
- Maximum number of sensors : Point sensor - 30ea, loop sensor - 12ea
Arc Eliminator

Safety
•Arc extinguishment by bypassing the arc current within 5 ms after an arc fault 
minimize the spread of accident
Arc Eliminator Controller

•CB trip signal output within 15 ms after an arc fault and power system separation
•Prevention of AE manual insertion caused by user's mistake(Electric return possible)
•KERI and KC certification based on KOEMA 0930, 0931, 0932, standards
※ APR : Arc Protection Relay, AEC : Arc Eliminator Controller, AE : Arc Eliminator, APM : Arc Protection Module

Section Standard specifications

Rated voltage (kV, rms) 7.2 / 12

Rated current (A, rms) 3,150


Power frequency
(kV, rms) 28
withstand voltage
Lightning impulse
(kV, peak) 75
withstand voltage
Rated short-time
(kA/s) 40
withstand current
Bypass time of fault current < 5ms

AE attachment method Cradle

Interlock Prevention of cradle insertion / Withdrawal in AE closed position

Standard KOEMA 0932

APS panel 구성

Arc Protection Relay Slave Unit Arc Eliminator Arc Eliminator Controller

08
High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House

C-AIS (Compact Air Insulated Switchgear)


LS C-AIS is a medium voltage product applied to secondary distribution systems up to 24 kV of rated voltage.
It requires less space for installation by reducing dimensions and weights, and this can save customers’
investment.
In addition, the user safety is enhanced by applying internal arc structure and various safety devices.

Section Standard specifications

Rated voltage (kV, rms) 12 17.5 24

Rated frequency (Hz) 50/60 50/60 50/60

Insekation level

Power frequency Insulation (kV, rms) 28 38 50


withstand voltage
Isolation (kV, rms) 32 45 60

Lightning impulse Insulation (kV, peak) 75 95 125


withstand voltage
Isolation (kV, peak) 85 110 145

Breaking capacity

Rated current (A, rms) 630 630 630

Short-time withstand current (kA/s) 16kA/3s, 21kA/3s , 25kA/1s

Making capacity (kA) 40 / 50 / 54.6kA

Internal arc calssification (kA/1s) 21 (A-FLR) : Option 21 (A-FLR) : Option 21 (A-FLR) : Option

09
AC Medium Voltage Products

SIS (Solid Insulated Switchgear)


LS is developing and producing solid isolation devices that realize SF6 free eco - friendly epoxy insulation to
comply with eco - friendly policies.
LS eco-friendly solid insulated switchgear is reliable product by applying the eco-friendly epoxy embedded VI
blocking device and a permanent magnet control device with high-performance switching life.
We applied external surface grounding and built it into a single phase segregated structure, preventing the
source of overhead short circuit accidents

Section Standard specifications

Bus type Single-line Double-line

Rated voltage (kV, rms) 24/25.8 25.8

Rated current (A, rms) Up to 1250 Up to 2000


Power frequency
(kV, rms) Up to 60 Up to 70
withstand voltage
Lightning impulse
(kV, peak) 125 Up to 150
withstand voltage
Rated frequency (Hz) 60 60
Short-time
(kA/s) 25/3 25/3
withstand current
Control voltage (V) AC 220 / DC 110 AC 220 / DC 110

Degree of protection (IP) 4X 4X

Size (W×D×H, mm) 600×1850×1770 600×2050×1850

Insulation material Epoxy Epoxy

Standard IEC 62271-200 IEC 62271-200

Certification KERI KERI

Main(Incoming) MOF PT Feeder Tie (CB) Tie (Riser)

Extensible Extensible Extensible

installable

Detachable Detachable
LA LA

Detachable
LA
Configurable Configurable

Extensible Extensible Extensible


Extensible

Withdrawable(Top & bottom) Withdrawable(Top & bottom)

10
High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House

CRT (Cast Resin Transformer) / Rectifier transformer


LS CRT satisfies both standard consumption efficiency and minimum consumption efficiency as a low-noise
and high-efficiency transformer that can improve use environments via low noises and reduce power costs
according to reduction of loss.
We launched transformers to meet the environmental changes such increases in large earthquake
occurrence frequency, power outages due to lightning or surges, increases in harmonic loads, etc. And the
needs from various customers. The transformer has a high seismic performance and a high impulse voltage
strength, and has various options such as harmonic measurement thermometers, sliding cooling fans, etc.

Section Standard specifications

Installation place Indoor(Enclosure needed for outdoor)

Applicable standard KS C 4311

Frequency 60

Insulation kind F type

Coil temperature rise 100K

1st rated voltage (kV) 22.9kV 6.6 or 3.3kV

F6900-R6600-6300-6000-5700
1st tap voltage (kV) F23900-R22900-21900-20900-19900
F3450-R3300-3150-3000-2850

2nd rated voltage 6.6 or 3.3kV 380-220V 220-110V 380-220V 220-110V

Phase 3P 3P 1P 3P 1P

Angular displacement Dd0 Dyn11 - Dyn11 -


Impulse 95 / 40(20) 95 / - 95 / -
(kV) 1st/ 2nd 40(20) / - 40(20) / -
withstand voltage 125 / 40(20) 125 / - 125 / -
Normal frequency
(kV) 1st/ 2nd 50 / 20(10) 50 / 3 50 / 3 20(10) / 3 20(10) / 3
withstand voltage
- 100 100 100 100
- 200 200 200 200
- 300 300 300 300
- 400 400 400 400
500 500 500 500 500
600 600 600 600 600
750 750 750 750 750
1,000 1,000 1,000 1,000 1,000
1,250 1,250 - 1,250 -
Rated capacity (kVA) 1,500 1,500 - 1,500 -
2,000 2,000 - 2,000 -
2,500 2,500 - 2,500 -
3,000 3,000 - 3,000 -
4,000 - - - -
5,000 - - - -
6,000 - - - -
7,500 - - - -
8,500 - - - -
10,000 - - - -

11
AC Medium Voltage Products

Option components
Digital thermometer/ Controller

P2-100 P2-400 P2-400CH


1 point temperature 3 or 4 point temperature 3 or 4 point temperature
measurement measurement measurement Harmonics
measurement

Cooling fan

Low noise cooling fan Large cooling fan Sliding cooling fan
Uninterrupted replacement

Other accessories

Wheel Enclosure Extension busbar

Causes of harmony  Harmonic countermeasure


•Personal computer •Installing manual filter
•Resistance welding machine •Installing active filter
•Static frequency converter •Transformer multiplexing
•Arc furnace •PWM
•Rectifier •Using insulated transformer
•Inverter •Using zig-zag wire
•Direct current shunt motor •Using NCT
•etc.

Considerations for manufacturing  Effect

•Reducing the magnetic flux density and loss •Heat and noise reduction in the core
•Reducing wind temperature of the conductor •Prevention of loss due to overheating of coils
•Using thin conductor •Eddy loss reduction
•Installing an electro-magnetic shield •Common mode harmonic reduction
•Reinforcement of coil insulation strength •Prevention of spike voltage

12
AC Low Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House

LS Low Voltage Switchgear provides optimized solution to meet various customer's needs.
It is designed and produced to construct high quality power systems in all kinds of industrial
field. It realizes compact size and also secures customer's convenience and safety.

Low voltage switchgear


LS susol low voltage switchgear & MCC is designed based on IEC 61439-1&2, and has achieved high reliability
by applying LS ACB and MCCB. It can prevent accident from spreading and guarantee user safety through
Form 4b structure and the application of multi-function wall.
In addition, it provides user-centered structure. 3-way of manual draw in/out for MCC unit improve usability
and the modularized chamber structure enhances maintenance convenience.
Its size is reduced up to 29% compared to our existing low voltage switchgears and it increases the quantity
of storage by applying 1/2 unit, so it can optimize space utilization in the electrical room.

Section Main Feeder MCC

Rated operating voltage (V) Up to 690 Up to 690 Up to 500

Main (A) Up to 5000 Up to 5000 Up to 5000


Rated current
Feeder (A) Up to 5000 Up to 5000 Up to 1500

Phases 3P4W 3P4W 3P4W

Rated Frequency (Hz) 50/60 50/60 50/60

Rated Short-time withstand current (kA/s) Up to 100 Up to 100 Up to 100

Arc fault containment (IEC TR 61641) (kA/s) Up to 100kA/0.3sec (85kA/0.5sec)

Rated insulated voltage (V) 1000 1000 750

Rated impulse withstand voltage (kV) 12 12 8

Degree of protection Up to IP54 Up to IP54 Up to IP54 *

Fron of Internal separation Form 4b Form 4b Form 4b

Size (W×D×H, mm) 1200×1000×2250 1150×1000×2250 1000×1000×2250

Standard IEC 61439-1 & 2 IEC 61439-1 & 2 IEC 61439-1 & 2
* MCC unit for IP54 is fixed type only.

13
SCADA

SCADA is a system that remotely monitors and controls the power facilities installed in the
power system.
It is a system for stable and highly reliable operation through real-time acquisition of power
data analysis, data trend analysis and operator-oriented control.

User-oriented Standardization
•GUI configuration of familiar Windows technologies •Data access and presentation through the same interface
and environments •Supports industry standards such as 3rd party activeX,
•Support various applications such as power excel, and reports
equipment diagnosis, power quality monitoring, •Operate a unified interface between operator and system
facility protection, and substation automation. •Supports system integration engineering tool

Intuitive analysis and operation Stable power system monitoring


•On-screen Help menu •Rapid recognition of accidents
•Visual system resource management for network, •Reduced recovery time with immediate response
CPU and disk •Peak control, planned power use
•Support for trends by providing a variety of chart styles
and grids
•Analysis of various intuitive information with Chart 3D

Delivery performance
•Outline│ Honam high speed rail integrated SCADA project(2014~)
•Feature │ Gyeongbu high speed railway 1 & 2 stage, Honam metropolitan area high-speed railway section,
substation / category / electric room /
electric power facility monitoring(RTU: 524) and general / wide-area railway substation / category /
monitoring of electric room power facilities(RTU: 941) SCADA construction business

14
High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House

PQMS (Power Quality Monitoring System)


PQMS analyzes the primary causes of power quality decline and suggests solutions for this problem by gathering
power quality information from the PQ meter installed in major power facilities and analyzing the information
in real time. In particular, this is a useful system for production facility systems requiring high quality of power.

•PQ data acquisition and application : PQ data acquisition, real time events, PQ event occurring trend analysis
•PQ analysis : 3D voltage event analysis, sag / swell analysis,
CBEMA and other statistical analysis, on / off line power quality analysis

PDPS (Power equipment Diagnosis & Preventive System)


PDPS monitors the functions and capabilities of major power facilities to prevent breakdown and accident in
advance and supports efficient power facility management through equipment records and DB management.

•On-line monitoring diagnosis : Indication of abnormality for each diagnosis category of TR and GIS for each Bay,
GIS PD measurement and 2D / 3D analysis screen, real time event and information screen indication,
real time communication condition
•Convenience of operator : - Monitoring screen editing - Communication device on-line setting
•Preventive diagnosis analysis : - Precise diagnosis of gas in liquid for specialized DB base

SAS (Substation Automation System)


SAS provides remote control and monitoring functions in real time, promptly acquiring the information of
facilities for all kinds of unmanned substations ranging from distribution to extra high voltage substations,
which may be applied to IEDs(Intelligent Electronic Devices) for protection and control and to the facility security
devices of the unmanned substation.

•Automatic control : Automatic interlocking, synchronous-check, balanced voltage regulation (tap-changer


control), transformer load balance control, automatic power failure /return control, load shedding,
automatic re-closing function, power factor control
•Facility protection : Generator protection, bus protection, bay protection, transformer protection,
power line protection, motor protection
•Data acquisition and application : Remote data acquisition and decision, event alarm report record,
accident waveform capture
•Facility status monitoring : GIS gal malfunction condition, circuit breaker condition, transformer condition

ECMS (Electrical equipment Control & Monitoring System)


ECMS carries out generator operation, management and control by applying multi-functional integrated digital
relay to the power-generating facilities and the power equipment within the power plants.

•Remote monitoring and control : - Operating status of circuit breakers / relays - Circuit breakers remote control
- Multi-level fluctuation control of the power generator
•IED analysis /correction : - Relay / logic operational status - Relay remote setting
•Harmonic / accident waveform analysis
•Protective function(IED) : Power generator / bay and line / transformer / breaker / motor protection

15
DC Medium Voltage Products

LS provides not only AC but also DC systems, which are essential for operating railway
facilities.
DC switchgears and DC rectifiers can be provided to meet customer needs and are committed
to stable railway operation.

DC switchgear
DC switchgear is designed to protect the DC powered railway line and integrated with high speed circuit
breakers for the rectifier, the power feeder and the backup application to prevent safety incidents.

Section Standard specification

Rated voltage (V) DC 900 (750) / 1800 (1500)

Rated current (A) 4000/6000

Rated breaking current (kA) 100

Applicable standard IEC 61992 / EN50123

DC rectifier
The free convention and silicon-based rectifier is designed to convert AC to DC.
Its large capacity and compact design ensures the reduction of space required for railway system installation.

Section Standard Specification

Capacity Up to 1500V, Up to 400kW

Connecting method 3-phase double bridge series/parallel

16
Smart E-House High Voltage Products AC Medium Voltage Products AC Low Voltage Products SCADA DC Medium Voltage Products E-House

E-House is a prefabricated modular enclosure to house a medium and low voltage


switchgear as well as auxiliary equipment in accordance with the customers’ equirements.
E-House allows cost savings, reduced lead time, risk reduction through the modular
design.

Optimized design Easy installation


•Complete LS portfolio of high and low voltage •Reduced installation time, low risk
switchgears •Pre-verification of installation
•Thorough technical analysis of the E-House •Convenient connection
design

Customization Total project management


•Protection from combustion hazard •Supply management for LS and third party
•Application of heat prevention paint equipment
•Heating, ventilating, and air conditioning (EC-Fan) •Cost savings, reduced total lead time
•Fire fighting system
•Interlocking type structure

MV/LV switchgear Metal housing

UPS HVAC
E-House
Transformer Fire Fighting System

SCADA system Fire & gas


Detection system

Section Canada E-House PJT Iraq mobile substation PJT Chile cochrane PJT
132/33kV mobile substation Chile cochrane thermoelectric power plant
Project Canada E-House
(S&P WORLD NETWORKS) (POSCO Construction)

Delivery 2017.09 2015.10 2014.04

Specifications Traction power substation 132/33kV 3P3W 6.9kV 3P3W

Container size 15000×5000×4300 – 9ea 12650×5200×3400 - 1ea


13000×3300×2737 - 10ea
(W×D×H, mm) 16500×5000×4300 – 2ea 14930×4900×3400 - 1ea

Project HVAC(Heating, Ventila- Seismic UBC code zone4


-40 ~ +40℃ -40 ~ +40℃
tion, Air Conditioning) Temperature conditions : 0 ~ +40℃
features
Applied steel plate ASTM A36 & KS SGC340 ASTM A36, ASTM A572 ASTM A36, ASTM A572

etc. 132kV DS, CB, Power TR, 33kV MCSG, RCP Installation of internal pressure-proof equipment

Canada E-House Iraq mobile substation Chile cochrane thermoelectric power plant
17
Global LS is engaged in business all over the world.
LS global network includes 7 overseas corporations,
Network 12 overseas branches, and 224 clients in 77 countries.

▶R&D ▶Factory

R&D campus Power device R&D center Automation R&D Center PT&T (Testing laboratory) Cheongju factory (Korea)
Focuses on gaining competitive Leading technology in electric Serves as the main research institute Internationally-renowned testing Electric products, mold TR, MV/LV
advantages through development industry and continuously developing for LS center that has formed partnerships switchgear, HV GIS
of next generation platforms future-growth dynamic engines with the UL, CE, KEMA and CESI

18
Head office
Domestic business establishment

Anyang Overseas manufacturing plant


R&D center
Head office Cheonan factory
Overseas sales corporation
Cheonan Automation소R&D center
Overseas branch
Cheongju factory 1
Cheongju factory 2 Global service center
Cheongju Power device R&D center
PT&T(Power Testing & Technology Institute) Global R&D center
Presence internationally : 77 countries

Busan
Busan factory

Cheonan factory (Korea) Busan factory (Korea) Wuxi factory (China) Dalian factory (China) Hanoi factory (Vietnam)
PLC, AC drive, HMI, DCS, PV module HV TR, HVDC, FACTS Electric products MV/LV switchgear, MV/LV switchgear,
MV contactor Mold TR

19
www.lselectric.co.kr

■Headquaters ■Overseas Branches


127, LS-ro(hogye-dong) Dongan-gu, Anyang-si, Gyeonggi-Do, 14119, Korea • LS ELECTRIC Tokyo Office (Japan)
Tel: 81-3-6268-8241 E-Mail: jschuna@lselectric.biz
■Seoul Office
LS Yongsan Tower, 92, Hangang-daero, Yongsan-gu, Seoul, 04386, Korea • LS ELECTRIC Beijing Office (China)
Tel: 86-10-5095-1631 E-Mail: chendm@lselectric.com.cn
Tel: 82-2-2034-4916, 4684, 4429
• LS ELECTRIC Shanghai Office (China)
■Overseas Subsidiaries Tel: 86-21-5237-9977 E-Mail: khpaek@lselectric.com.cn
• LS ELECTRIC Japan Co., Ltd. (Tokyo, Japan)
Tel: 81-3-6268-8241 E-Mail: jschuna@lselectric.biz • LS ELECTRIC Guangzhou Office (China)
Tel: 86-20-3818-2883 E-Mail: chenxs@lselectric.com.cn
• LS ELECTRIC (Dalian) Co., Ltd. (Dalian, China)
Tel: 86-411-8730-5872 E-Mail: jiheo@lselectric.com.cn • LS ELECTRIC Chengdu Office (China)
Tel: 86-28-8670-3201 E-Mail: yangcf@lselectric.com.cn
• LS ELECTRIC (Wuxi) Co., Ltd. (Wuxi, China)
Tel: 86-510-6851-6666 E-Mail: jdyim@lselectric.com.cn • LS ELECTRIC Qingdao Office (China)
• LS ELECTRIC Vietnam Co., Ltd. Tel: 86-532-8501-2065 E-Mail: wangzy@lselectric.com.cn
Tel: 84-93-631-4099 E-Mail: jhchoi4@lselectric.biz (Hanoi) • LS ELECTRIC Nanjing Office (China)
Tel: 84-28-3823-7890 E-Mail: sjbaik@lselectric.biz (Hochiminh) Tel:86-25-8467-0005 E-Mail: ylong@lselectric.com.cn
• LS ELECTRIC Middle East FZE (Dubai, U.A.E.)
Tel: 971-4-886-5360 E-Mail: hschoib@lselectric.biz • LS ELECTRIC Bangkok Office (Thailand)
Tel: 66-90-950-9683 E-Mail: sjleet@lselectric.biz
• LS ELECTRIC Europe B.V. (Hoofddorf, Netherlands)
Tel: 31-20-654-1424 E-Mail: europartner@lselectric.biz • LS ELECTRIC Jakarta Office (Indonesia)
Tel: 62-21-2933-7614 E-Mail: yjleee@lselectric.biz
• LS ELECTRIC America Inc. (Chicago, USA)
Tel: 1-800-891-2941 E-Mail: sales.us@lselectricamerica.com • LS ELECTRIC Moscow Office (Russia)
Tel: 7-499-682-6130 E-Mail: jdpark1@lselectric.biz

• LS ELECTRIC America Western Office (Irvine, USA)


Tel: 1-949-333-3140 E-Mail: jwyun@lselectricamerica.com

2020. 04 2019. 03. LS ELECTRIC Co.,Ltd. All rights reserved. / (01) 2020. 04. PACO STORY

You might also like