TO : ALL SHIP
ATT’N : ALL STAFF
SUBJECT : CALIBRATION METHOD FOR 15 PPM BILGE ALARM MONITOR
1. Outline
PSC inspector pointed out the abnormal condition which indicator of 15 ppm
monitor was fluctuated hunted and instant alarm was disappeared at alarm point.
Therefore, it is pleased to be noticed calibration method as follows.
3) Calibration method
① Adjust the terminal voltage of “LED +/- test point”of Main Board to D.C
1.17V~1.2V by adjusting RV204 with using of multi-tester.
② Supply fresh water to bilge alarm monitor module
③ Adjust the terminal voltage between “Direct test point”and “0V test
point” by RV102 in Pre. Amp. Board to D.C 9V~ D.C 9.2V.
④ Adjust the terminal voltage between “Scatter test point”and “0V test
point” by RV101 in Pre. Amp. Board to D.C 0.5V~ D.C 0.6V.
⑤ Measure the terminal voltage between “output test point” and 0V test
point” and then it should be same as “X-value”as follows formula
SCATTER ÷ DIRECT × 10 = X
If the value is not same as the measured value, replace Pre. Amp. Board
or Main board.
Nevertheless if the value is not same, submit a repair requisition.
The end.